• Title/Summary/Keyword: Radiation medicine

Search Result 3,947, Processing Time 0.038 seconds

Investigation on the Perception of Mandatory Clinical Practice in the Department of Radiology Following the Amendment of the Medical Technologists Act (의료기사 등에 관한 법률 개정으로 방사선(학)과 현장실습 의무화에 따른 인식 조사)

  • Jeong-Mu Lee;Yong-Ki Lee;Sung-Min Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.293-300
    • /
    • 2024
  • On October 31, 2023, the revision of the Medical Technologist Act made it mandatory to complete field training courses in order to obtain a license as a radiologic technologist. Therefore, we would like to survey the actual situation of field training in medical institutions to inform the revised Medical Technologist Act and propose improvement measures to increase the effectiveness of field training. A survey was conducted from March to April, 2023, among radiologic technologists working in medical institutions. The questionnaire was sent through a form on a domestic portal site, Company N, and 120 respondents completed it. Eighty-two respondents, or 68.3 percent, had experience in educating on-the-job training students. 58% of the respondents were aware of the fact that the amendment to the Act on Medical Technologist etc. made field training mandatory to obtain a radiologic technologist license. In accordance with Article 9 of the Medical Technologist Act, which prohibits unlicensed persons from practicing, 50% of the respondents were aware that those who are in training to complete an education course equivalent to the license they are seeking to obtain at a university or other institution are allowed to practice as medical Technologists. When asked what is currently taught during fieldwork, 6% of respondents said that they are required to perform radiation-generating activities in addition to observing, guiding patients, and positioning and moving patients. When asked about the future direction of education as fieldwork becomes mandatory for licensure, 77% of respondents said that they will teach more than they currently do. When asked about the appropriate total length of fieldwork, 35% said 12 weeks and 480 hours, 33% said 8 weeks and 320 hours, and 27% said 16 weeks and 640 hours. It can be seen that the current on-the-job training is inadequate according to various regulations, and students' satisfaction is low. However, with the revision of the Act on Medical Technologists, field training has become mandatory to obtain a license as a radiologist, and it is necessary to improve the educational conditions of field training. Therefore, it is necessary to comply with the Nuclear Safety Act and the Rules on the Safety Management of Diagnostic Radiation Generating Devices, introduce standardized training objectives and evaluation systems, designate training hospitals and radiologists in charge of training, and introduce extended training periods and simulation exercises to internalize field training.

Effects of enucleation and chemotherapy in advanced intraocular and intraorbital retinoblastoma with or without radiotherapy (진행된 안구내 및 안와내 망막모세포종에서 안구적출술과 항암화학치료 및 방사선조사 유무에 따른 효과)

  • Lee, Jae Min;Lee, Hyun Dong;Hah, Jeong Ok
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.1
    • /
    • pp.84-88
    • /
    • 2008
  • Purpose : Radiotherapy is effective in local treatment for retinoblastoma. However, asymmetric facial hypoplasia after radiation is a serious late effect. This study was performed to investigate the effects of enucleation and chemotherapy with or without radiotherapy in advanced intraocular and intraorbital retinoblastoma. Methods : Between 1985 October and 2006 December, the records of thirty five patients who were diagnosed as retinoblastoma at Yeungnam University Hospital were reviewed. Advanced intraocular and intraorbital retinoblastoma patients classified as Reese-Ellsworth group III, IV, and V and Grabowski- Abramson class II were selected for the study. Results : Eighteen patients were enrolled in this study. All patients were enucleated and had received chemotherapy. Nine patients received radiotherapy and nine patients didn't receive radiotherapy. Tumor cells were found on resection margin of optic nerve in five of nine patients who received radiotherapy, but none of nine who didn't receive radiotherapy. Chemotherapy included vincristine, adriamycin, cyclophosphamide, VM-26, cisplatin before 2001, and vincristine, etoposide, and carboplatin after 2001. There were no recurrences or metastases in nine patients who didn't receive radiotherapy. But two of nine patients who received radiotherapy had metastases to brain. However, all survivors who received radiotherapy had significant facial asymmetry. Conclusion : In advanced intraocular and intraorbital retinoblastoma without tumor cell on resection margin of optic nerve, enucleation and chemotherapy without local radiotherapy appears to be safe for long-term survival. However, in those with tumor cells on resection margin of optic nerve, enucleation and chemotherapy with local radiotherapy seems to be necessary to improve survival.

Usefulness of Ultrasonographic Examination by a Pediatrician in Children with Abdominal Pain (소아 복통에서 소아과 의사에 의한 초음파 검사의 유용성)

  • Park, Hyun-Seok;We, Ju-Hee;Park, Jae-Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.14 no.2
    • /
    • pp.141-147
    • /
    • 2011
  • Purpose: Ultrasonography (US) is widely used as a screening test in patients with abdominal pain (AP). We investigated the usefulness of US by a pediatrician in children with AP. Methods: We retrospectively analysed the medical records of children with AP who undertook US from December, 2008 to July, 2010. Results: A total of 628 patients (325 male, 303 female) were enrolled in this study. The mean age of patients was $8.08{\pm}4.61$ years. Duration of AP was acute in 427 and chronic in 201 patients. Localization of AP was diffuse (36.9%), periumbilical (24.4%), epigastric (21.0%), and right lower quadrant (8.1%). On the examination, there were no abnormal findings in 327 patients (52.1%). Abnormal ultrasonographic findings were mesenteric lymphadenitis (27.1%), intestinal mural thickening (10.0%), intussusception (3.0%), appendicitis (2.6%), choledochal cyst (1.6%), and pancreatitis (0.3%). We performed additional imaging studies such as computed tomography (CT) or magnetic resonance imaging (MRI) in 39 patients who showed obscure findings on the US. In 33 patients (84.6%), the same results were obtained from CT or MRI. Two cases of appendicitis, one case of pancreatitis and one case of Henoch-Sh$\ddot{o}$nlein purpura were diagnosed by the CT examination. However, there were two cases of appendicitis diagnosed by US thathad no evidence of appendicitis on the CT. Diagnostic accuracy of initial US in children with abdominal pain was 99.4%. Conclusion: US by a pediatrician as a screening test in children with AP provides a rapid and accurate diagnostic indication and has non-invasive and radiation-free advantages.

The Effect of a Chest CT Scan on the Treatment and Diagnosis of Major Blunt Chest Trauma (흉부 둔상환자에서 흉부전산화단층촬영이 진단과 치료에 미치는 영향)

  • Park, Il-Hwan;Oh, Joong-Hwan;Lee, Chong-Kook
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.226-232
    • /
    • 2009
  • Background: Blunt chest trauma accounts for 90% of all chest traumas in Europe and the United States and this causes 20% of all trauma-related deaths. The major cause of morbidity and mortality after blunt chest trauma is undetected injuries. For this reason, chest computerized tomography has gained popularity for the evaluation of trauma, but it is expensive and it exposes patients to radiation. This study identified the clinical features associated with the diagnosic information obtained on a CT chest scan, as compared with a standard chest X-ray, for patients who sustained blunt trauma to the chest. This study also evaluated the role of a routine computed tomographic (CT) scan for these patients. The patients who had chest computed tomography done after the initial chest x-ray were analyzed separately for the presence of occult injuries. Material and Method: We studied 100 consecutive patients from November 2006 to July 2007: 74 patients after motor vehicle crashes and 26 patients after a fall from a height >2m. Simultaneous with the initial clinical evaluation, an anteroposterior chest radiograph and a helical chest CT scan were obtained for all the patients. The data extracted from the medical record included the vital signs, the interventions and the type and severity of injury (RTS). Result: Among the 100 cases, 79 patients showed at least more than one pathologic sign on their chest radiograph, and 21 patients had a normal chest radiograph. For 17 of the patients who had a normal chest X ray, the CT scan showed multiple injuries, which were pneumothorax, hemothorax, lung contusion, sternal fracture etc. This represents that a CT scan is statistically superior to a chest radiograph to diagnose the pathologic signs. But on the other hand, as for treatment, only 31 patients were diagnosed by CT scan and they were treated with chest tube insertion ect. 42 patients needed ony conservative management without invasive thoracosurgical treatment such as chest tube insertion or open thoracotomy. 27 patients were treated based on the diagnosis made by the chest radiograph and physical examination. Conclusion: Chest computerized tomography was significantly more effective than routine chest X-ray for detecting lung contusion, pneumothorax and mediastinal hematoma, as well as fractured ribs, scapula and, sternum. Although the occult findings increased, the number of patients who needed treatment was small. Therefore, we suggest making selective use of a CT scan to avoid its overuse in ERs.

The Study on the Reduction of Patient Surface Dose Through the use of Copper Filter in a Digital Chest Radiography (디지털 흉부 촬영에서 구리필터사용에 따른 환자 표면선량 감소효과에 관한 연구)

  • Shin, Soo-In;Kim, Chong-Yeal;Kim, Sung-Chul
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.223-228
    • /
    • 2008
  • The most critical point in the medical use of radiation is to minimize the patient's entrance dose while maintaining the diagnostic function. Low-energy photons (long wave X-ray) among diagnostic X-rays are unnecessary because they are mostly absorbed and contribute the increase of patient's entrance dose. The most effective method to eliminate the low-energy photons is to use the filtering plate. The experiments were performed by observing the image quality. The skin entrance dose was 0.3 mmCu (copper) filter. A total of 80 images were prepared as two sets of 40 cuts. In the first set (of 40 cuts), 20 cuts were prepared for the non-filter set and another 20 cuts for the Cu filter of signal + noise image set. In the second set of 40 cuts, 20 cuts were prepared for the non-filter set and another 20 cuts for the Cu filter of non-signal image (noisy image) with random location of diameter 4 mm and 3 mm thickness of acryl disc for ROC signal at the chest phantom. P(S/s) and P(S/n) were calculated and the ROC curve was described in terms of sensitivity and specificity. Accuracy were evaluated after reading by five radiologists. The number of optically observable lesions was counted through ANSI chest phantom and contrast-detail phantom by recommendation of AAPM when non-filter or Cu filter was used, and the skin entrance dose was also measured for both conditions. As the result of the study, when the Cu filter was applied, favorable outcomes were observed on, the ROC Curve was located on the upper left area, sensitivity, accuracy and the number of CD phantom lesions were reasonable. Furthermore, if skin entrance dose was reduced, the use of additional filtration may be required to be considered in many other cases.

  • PDF

A Study on the Measurement of the Pollution Level of Bacteria and Disinfection of Table and IP Cassette (촬영 테이블과 IP Cassette의 세균 오염도 측정 및 소독에 관한 연구)

  • Bae, Seok-Hwan;Lee, Moo-Sik;Lim, Chang-Seon;Kim, Gha-Jung
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.229-237
    • /
    • 2008
  • Purpose : For the number of microbes and the pollution level of bacteriology of IP Cassette and Table by laboratories, after identifying the bacteria before and after using alcohol and tissue including disinfectant and statistically testing, this research was intended to provide the basic data for the prevention and the right disinfection guideline for infection management of hospitals in diagnostic radiology. Subject and Method : The subject of this research was the general room of diagnostic radiology of a university hospital in Daejeon City. The research was conducted from Apr 5 to Apr 12, 2007. The number of microbes and the pollution level of bacteriology of IP Cassette and Table by laboratories were tested before and after using alcohol and tissue for disinfection including disinfectant. In order to collect specimens exactly, they were collected with the nurse who specialized in infection management of the hospital, and statistical processing was done with SPSS V13.0. To compare the results before and after using alcohol and tissue, T-test was implemented, and post-hoc test was conducted. Results : Bacteria were detected in 19 cases of 24 subjects(79.2%), however, they were not detected in 5 cases(20.8%). 7kinds of bacteria were detected as isolated bacteria, of which Methicillin Resistant coagulase-negative Staphylococci(MRCNS) were detected in 15 cases(62.5%), which was most, Methicillin Resistant Staphylococcus Aureus(MRSA) in 6 cases(16.7%), Enterococcus Faecium(EFM) in 5 cases(20.8%), Acinetobacter baumannii(ABA) in 2 cases(8.3%), and Bacillus sp, Coagulase-negative Staphylococci(CNS), and Enterococcus sp(ENT) in 1 case, respectively(4.2%). In all bacteria except ABA, Gram positive bacillia were detected in 30 cases(97%), and Gram negative bacilli were detected only in 1 case(3%). As for the kinds of bacteria and the number of groups before and after using 70% Alcohol by Groups, when the bacteria were identified after disinfecting IP Cassette and Table with 70% Alcohol, all the bacteria became extinct in both IP Cassette and Table Group(100%). As for the kinds and number of bacteria before and after using Tissue Cleaner by Groups, the bacteria in Tissue Cleaner Group became completely extinct only in 10 Groups(71.2%), and in 4 Groups, there was much decrease in bacteria, however, they were still detected. The extinction rate of all the bacteria was 91.5%. That is, though the other bacteria became extinct(100%), that of MRCNS bacteria was lowest(83.6%), followed by MRSA(95%). Conclusion : As a result of comparing the mean of the bacteria which were detected before and after using 70% Alcohol and Tissue Cleaner, there was statistically significant in the significant level of 5% in both of them.

  • PDF

The Caspase-3 and c-myc Expressions in Completely Resected Non-small Cell Lung Cancer and Its Prognostic Significance (완전 절제된 원발성 비소세포 폐암에서 Caspase-3와 c-myc 단백의 발현과 임상 예후)

  • Cho, Deog-Gon;Cho, Kyu-Do;Kang, Chul-Ung;Jo, Min-Seop;Yoo, Jin-Young;Ahn, Myeong-Im;Kim, Chi-Hong;Shim, Byoung-Yong;Kim, Sung-Whan;Kim, Hoon-Kyo
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.447-456
    • /
    • 2008
  • Background: Caspase-3 is a cysteine protease that plays a major role in the process of apoptotic cell death. The dysregulated expression of c-myc contributes to the tumorigenesis in a variety of human cancers. The aim of this study was to investigate the expressions of caspase-3 and c-myc and their significances as prognosis markers in patients with completely resected non-small cell lung cancer (NSCLC). Material and Method: A total 130 consecutive patients who had undergone complete resection without pre-operative radio-therapy or chemotherapy between May 1996 and December 2003 for NSCLC were retrospectively reviewed. The median follow-up period of the patients was 50 months (range: $3{\sim}128$ months). The expressions of caspase-3 and c-myc were immuno-histochemically examined, and these were correlated with the clinico-pathologic data. Result: The prevalence of caspase-3 and c-myc expressions in the patients was 68% (88/130) and 59% (77/130), respectively. Significant association was found between the frequency of the expressions of caspase-3 and c-myc (p=0.025). The caspase-3 and c-myc expressions were not significantly associated with the prognosis in all the patients. However, according to stages, a positive caspase-3 expression was significantly correlated with a favorable prognosis for patients with stage IIIa disease (median survival period: 35 months vs. 10 months, p=0.021). Multivariate analysis showed the pathologic stage to be significantly correlated with a good prognosis in all the patients (p=0.024), and with a positive caspase-3 expression, well differentiated tumor and negative neuronal invasion in the patients with stage llla disease (p=0.005, p=0.003, p=0.004, respectively). Conclusion: Caspase-3 and c-myc were frequently expressed in NSCLC, suggesting its possible involvement in tumor development. The caspase-3 expression, as determined with performing immunohistochemical staining, may be a favorable prognostic indicator in patients with completely resected NSCLC an advanced stage (IIIa).

3-Dimensional Verification Technique for Target Point Error (자기공명영상기반 겔 선량측정법을 이용한 3차원적 목표 중심점 점검기술)

  • Lee, Kyung-Nam;Lee, Dong-Joon;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.35-41
    • /
    • 2011
  • For overall system test, hidden-target test have been used using film which leads to inherent analysis error. The purpose of our study is to quantify this error and to propose gel dosimeter based verification technique for 3-dimensional target point error. The phantom was made for simulation of human head and this has ability to equip 10 gel-dosimeter. $BANGkit^{TM}$ which we are able to manufacture whenever it is needed as well as to easily change the container with different shapes was used as a gel dosimeter. The 10 targets were divided into two groups based on shapes of areas with a planned 50% isodose line. All treatment and analysis was performed three times using Novalis and $BrainSCAN^{TM}$. The target point error is $0.77{\pm}0.15mm$ for 10 targets and directional target point error in each direction is $0.54{\pm}0.23mm$, $0.37{\pm}0.08mm$, $0.33{\pm}0.10mm$ in AP (anterior-posterior), LAT (lateral), and VERT (vertical) direction, respectively. The result of less than 1 mm shows that the treatment was performed through each precise step in treatment procedure. In conclusion, the 3-dimensional target point verification technique can be one of the techniques for overall system test.

Clinical Utility of Turbo Contrase-Enhanced MR Angiography for the Major Branches of the Aortic Arch (대동맥궁 주요 분지들의 고속 조영증강 자기공명혈관조영술의 임상적 유용성)

  • Su Ok Seong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.96-103
    • /
    • 1998
  • Purpose : To assess the clinical utility of turbo contrast-enhanced magnetic resonance angiography(CE MRA) in the evaluation of the aortic arch and its major branches and to compare the image quality of CE MRA among different coils used. Materials and Methods : Turbo three-phase dynamic CE MRA encompassing aortic arch and its major branches was prospectively performed after manual bolus IV injection of contrast material in 29 patients with suspected cerebrovascular diseases at 1.0T MR unit. the raw data were obtained with 3-D FISH sequence (TR 5.4ms, TE 2.3ms, flip angle 30, slab thickness 80nm, effective slice thickness 4.0mm, matrix size $100{\times}256$, FOV 280mm). Total data acquisition time was 4. to 60 seconds. We subjectively evaluated the imge quality with three-rating scheme : "good" for unequivocal normal finding, "fair" for relatively satisfactory quality to diagnose 'normal' despite intravascular low signal, and "poor" for equivocal diagnosis or non-visualization of the origin or segment of the vessels due to low signal or artifacts which needs catheter angiography. At the level of the carotid bifurcation, it was compared with conventional 2D-TOF MRA image. Overall image quality was also compared visually and quantitatively by measuring signal-to-noise ratios (SNRs) of the ascending aorta, the innominate artery and both common carotid arteries among the three different coils used(CP body array(n=12), CP neck array(n=9), and head-and-neck(n=8). Results : Demonstration of the aortic arch and its major branches was rated as "good" in 55% (16/29) and "fair" in 34%(10/29). At the level of the carotid bifurcation, image quality of turbo CE MRA was same as or better than conventional 2D-TOF MRA in 65% (17/26). Overall image quality and SNR were significantlygreater with CP body array coil than with CP neck array or head-and-neck coil. Conclusions : Turbo CE MRA can be used as a screening exam in the evaluation of the major branches of the aortic arch from their origin to the skull base. Overall imagequality appears to be better with CP body array coil than with CP neck array coil or head-and-neck coil.

  • PDF

Atorvastatin and Fluvastatin Can Reduce IL-1β-induced Inflammatory Responses in Human Keratinocytes (Atorvastatin 그리고 fluvastatin 약물의 IL-1β-유도 염증반응 억제 효과)

  • Choe, Yeong-In;Moon, Kyoung Mi;Yoo, Jae Cheal;Byun, June-Ho;Hwang, Sun-Chul;Moon, Dong Kyu;Woo, Dong Kyun
    • Journal of Life Science
    • /
    • v.31 no.4
    • /
    • pp.418-424
    • /
    • 2021
  • Skin inflammation (dermatitis) is caused by varying skin damage due to ultraviolet radiation and microbial infection. Currently prescribed drugs for dermatitis include anti-histamine and steroid drug classes that soothe inflammation. However, incorrect or prolonged use of steroids can cause weakening of skin barriers as well as osteoporosis. Therefore, treating dermatitis with a drug that has minimal side effects is important. Statins, also known as 3-hydroxy-3-methylglutaryl-coenzyme A reductase inhibitors, are cholesterol-lowering drugs that have been widely treated for hyperlipidemia and cardiovascular diseases. Interestingly, recent studies have shown the anti-inflammatory effects of statins in both experimental and clinical models for of osteoarthritis. This study investigated the possible anti-inflammatory effects of atorvastatin and fluvastatin in human keratinocytes (HaCaT cells), which are crucial components of skin barriers. Stimulation of HaCaT cells with IL-1β increased the expression of the COX2 protein, a major player of inflammatory responses. However, this induction of the COX2 protein was downregulated by pretreatments with atorvastatin and fluvastatin. Treatment with IL-1ß-induced the upregulation of other inflammatory genes (such as iNOS and MMP-1) and these expressions were similarly lowered by these two statin drug treatments. Taken together, these results indicated that atorvastatin and fluvastatin can reduce IL-1β-induced inflammatory responses in HaCaT cells. In conclusion, the findings suggest that atorvastatin and fluvastatin can be potential modulators for ameliorating skin inflammation.