• Title/Summary/Keyword: Radiation information source

Search Result 154, Processing Time 0.023 seconds

Radiation Safety Exploration Using Radio-photoluminescence Dosimeter for Crookes Tubes in Junior and Senior High School in Japan

  • Akiyoshi, Masafumi;Do, Duy Khiem;Yamaguchi, Ichiro;Kakefu, Tomohisa;Miyakawa, Toshiharu
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.3
    • /
    • pp.106-111
    • /
    • 2021
  • Background: Crookes tube is utilized in junior high and high schools in Japan to study the character of electrons and current, and not for radiological education. There is no official guideline or regulation for these radiation source to the public. Therefore, most teachers have no information about the leakage of X-rays from Crookes tube. The peak energy of X-rays is approximately 20 keV, and it is impossible to measure using conventional survey meters. Materials and Methods: Each leakage dose of low energy X-rays from 38 Crookes tube in the education field, such as junior and senior high schools in Japan, was explored by the teachers in the school using radio-photoluminescence (RPL) dosimeters. Before and after the measurements, the dosimeters were sent by postal mails. Results and Discussion: At the exploration in this study, it was estimated that the 70 ㎛ dose equivalent, Hp(0.07) of X-rays from 31 Crookes tubes were smaller than 100 µSv in 10 minutes, at the distance of 1 m, where the Crookes tube was usually observed. However, the highest dose was estimated as 0.69 mSv by an equipment with the full power. Furthermore, one Crookes tube exhibited 0.62 mSv with minimum output power of the induction coil. This relatively large dose was reduced by the shorter distance of discharge electrodes of the induction coil. Conclusion: The leakage dose of low energy X-rays from 38 Crookes tube was explored using RPL dosimeters. It was estimated that the Hp(0.07) of X-rays from 31 Crookes tubes were smaller than 100 µSv in 10 minutes at the distance of 1 m, while some equipment radiated a higher dose. With this study, the provisional guideline for the safety operation of Crookes tube is established.

Investigation of the Acoustic Performance of Music Halls Using Measured Radiation Characteristics of the Korean Traditional Musical Instruments (국악기의 음향방사특성에 따른 국악당의 음향성능조사)

  • Haan Chan-Hoon;Lee Wangu;Jeong Cheol-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.8
    • /
    • pp.469-480
    • /
    • 2005
  • There have been always some difficulties in target setting and conditioning of acoustic performances or the Korean traditional music hall due mainly to the lack of the information on the sound radiation characteristics of Korean musical sources. As the 2nd experiment succeeding the previous study[1], the radiation characteristics of eight typical Korean traditional musical sources were investigated if precision. The selected musical sources were Geomungo, Haegeum (string), Piri, Taepyeongso (woodwind), Buk, Kwaengguari, Jing (drum), and male Pansori Chang (vocal Performance). The results show that the directivity pattern of each instrument is different and has their own directivity characteristics. Measured directional and spectral characteristics of traditional Korean music sources were implemented into the computation of architectural acoustic measures. Significant differences in the acoustic measures at receiver positions were observed between the results in using the omni-directional source and the directional one. In order to investigate the acoustical characteristics of the instruments depending on the spatial variation four different shapes of halls were introduced including rectangular, fan. horse-shoe and geometrical shapes. Room acoustical parameters such as RT, SPL, C80, LF, STI were calculated at each type or hall. As the results, It was found that the rectangular hall has the most high clarity. lateral energy and STI values among low shapes of halls. It is thought that the suggested source data and design method can be used as a basic reference in the future acoustic design of performance halls for the Korean traditional music.

Energy Spectrum Measurement of High Power and High Energy (6 and 9 MeV) Pulsed X-ray Source for Industrial Use

  • Takagi, Hiroyuki;Murata, Isao
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.93-99
    • /
    • 2016
  • Background: Industrial X-ray CT system is normally applied to non-destructive testing (NDT) for industrial product made from metal. Furthermore there are some special CT systems, which have an ability to inspect nuclear fuel assemblies or rocket motors, using high power and high energy (more than 6 MeV) pulsed X-ray source. In these case, pulsed X-ray are produced by the electron linear accelerator, and a huge number of photons with a wide energy spectrum are produced within a very short period. Consequently, it is difficult to measure the X-ray energy spectrum for such accelerator-based X-ray sources using simple spectrometry. Due to this difficulty, unexpected images and artifacts which lead to incorrect density information and dimensions of specimens cannot be avoided in CT images. For getting highly precise CT images, it is important to know the precise energy spectrum of emitted X-rays. Materials and Methods: In order to realize it we investigated a new approach utilizing the Bayesian estimation method combined with an attenuation curve measurement using step shaped attenuation material. This method was validated by precise measurement of energy spectrum from a 1 MeV electron accelerator. In this study, to extend the applicable X-ray energy range we tried to measure energy spectra of X-ray sources from 6 and 9 MeV linear accelerators by using the recently developed method. Results and Discussion: In this study, an attenuation curves are measured by using a step-shaped attenuation materials of aluminum and steel individually, and the each X-ray spectrum is reconstructed from the measured attenuation curve by the spectrum type Bayesian estimation method. Conclusion: The obtained result shows good agreement with simulated spectra, and the presently developed technique is adaptable for high energy X-ray source more than 6 MeV.

A Study on Adaptive Pattern Null Synthesis for Active Phased Array Antenna (능동위상배열안테나의 적응형 패턴 널 형성에 관한 연구)

  • Jung, Jin-Woo;Park, Sung-Il
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.3
    • /
    • pp.407-416
    • /
    • 2021
  • An active phased array antennas can not only electrically steer the beam by controlling the weighting of the excitation signal, but can also form a pattern null in the direction of the interference source. The weight of the excitation signal to steer the main beam can be easily calculated based on the position of the radiating element. In addition, the weight of the excited signal for pattern null formation can also be calculated by setting the required radiation pattern and using WLSM(Weighted Least Squares Method). However, in a general wireless communication network environment, the location of the interference source is unknown. Therefore, an adaptive pattern null synthesis is needed. In this paper, it was confirmed that pattern null synthesis according to the required radiation characteristic was possible. And based on this, adaptive pattern null synthesis into the direction of an interference source was studied using a binary search algorithm based on observation area. As a result of conducting a simulation based on the presented technique, it was confirmed that adaptive pattern null forming into the direction of an interference is possible in efficient way.

Radiation characteristics of A Circular Loop antenna In Moving Media (운동매질내에서의 Circular Loop Antenna의 개체특성)

  • 최병하
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.7 no.3
    • /
    • pp.12-18
    • /
    • 1970
  • In this paper, the radiation characteristics of a Circular Loop Antenna is studied in a moving homogeneous, isotropic and linear media with a constant velocity much less than the speed of light. In Stuffing the radiation characteristics, Srst vector potential on the loop antenna is derived in the moving media by appling Maxwell-Minkowaski's theory. Next, using the derived relations, the electric and magnetic Seld is calculated for the spec-i Sed wave length ana velocity of the media. The Seld patterns in the moving media are compared with those of stationary media. We find that the intensity of the field is reduced in the direction of the media velocity and increased in the opposite direction only for the component parallel with the plane of the antenna. The deviation from the stationary media is proportional to the velocity of the media and the frequency of source current.

  • PDF

A Study on the Radioactive Products of Components in Proton Accelerator on Short Term Usage Using Computed Simulation (몬테칼로 시뮬레이션을 활용한 양성자가속기 단기사용 시 구성품의 방사화 평가)

  • Bae, Sang-Il;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.389-395
    • /
    • 2020
  • The evaluation of radioactivated components of heavy-ion accelerator facilities affects the safety of radiation management and the exposure dose for workers. and this is an important issue when predicting the disposal cost of waste during maintenance and dismantling of accelerator facilities. In this study, the FLUKA code was used to simulate the proton treatment device nozzle and classify the radio-nuclides and total radioactivity generated by each component over a short period of time. The source term was evaluated using NIST reference beam data, and the neutron flux generated for each component was calculated using the evaluated beam data. Radioactive isotopes caused by generated neutrons were compared and evaluated using nuclide information from the International Radiation Protection Association and the Korea Radioisotope association. Most of the nuclides produced form of beta rays and electron capture, and short-lived nuclides dominated. However, In the case of 54Mn, which is a radioactive product of iron, the effect of gamma rays should be considered. In the case of tritium generated from a material with a low atomic number, it is considered that handling care should be taken due to its long half-life.

RESULTS OF THE TOTAL DOSE EXPERIMENT ON KITSAT-1 (우리별 1호에서의 총 방사선 측정 실험)

  • 이대희;신영훈;민경욱
    • Journal of Astronomy and Space Sciences
    • /
    • v.14 no.1
    • /
    • pp.80-86
    • /
    • 1997
  • High energy particles in the earth's radiation belts cause transient and long term effects on electronic materials, devices, and integrated circuits on board the satellites. Hence, it is very important to have the information on the space radiation environment and the damage on the electronics caused by the se high energy particles. One of the radiation monitor devices frequently used in space is RADFET, a specially designed MOSFET with a thick gate oxide region. The present study focuses on the calibration of RADFET TOT500 using the $Co^{60}{\gamma}-ray$ source. The result shows that the response of RADFET is very sensitive to the change of temperature. The peculiar behavior observed in the TDE (Total Dose Experiment) on board the KITSAT-1 is identified as the thermal effect due to the change in the eclipse rate of the satellite.

  • PDF

A novel method for determining dose distribution on panoramic reconstruction computed tomography images from radiotherapy computed tomography

  • Hiroyuki Okamoto;Madoka Sakuramachi;Wakako Yatsuoka;Takao Ueno;Kouji Katsura;Naoya Murakami;Satoshi Nakamura;Kotaro Iijima;Takahito Chiba;Hiroki Nakayama;Yasunori Shuto;Yuki Takano;Yuta Kobayashi;Hironori Kishida;Yuka Urago;Masato Nishitani;Shuka Nishina;Koushin Arai;Hiroshi Igaki
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.129-137
    • /
    • 2024
  • Purpose: Patients with head and neck cancer (HNC) who undergo dental procedures during radiotherapy (RT) face an increased risk of developing osteoradionecrosis (ORN). Accordingly, new tools must be developed to extract critical information regarding the dose delivered to the teeth and mandible. This article proposes a novel approach for visualizing 3-dimensional planned dose distributions on panoramic reconstruction computed tomography (pCT) images. Materials and Methods: Four patients with HNC who underwent volumetric modulated arc therapy were included. One patient experienced ORN and required the extraction of teeth after RT. In the study approach, the dental arch curve (DAC) was defined using an open-source platform. Subsequently, pCT images and dose distributions were generated based on the new coordinate system. All teeth and mandibles were delineated on both the original CT and pCT images. To evaluate the consistency of dose metrics, the Mann-Whitney U test and Student t-test were employed. Results: A total of 61 teeth and 4 mandibles were evaluated. The correlation coefficient between the 2 methods was 0.999, and no statistically significant difference was observed (P>0.05). This method facilitated a straightforward and intuitive understanding of the delivered dose. In 1 patient, ORN corresponded to the region of the root and the gum receiving a high dosage (approximately 70 Gy). Conclusion: The proposed method particularly benefits dentists involved in the management of patients with HNC. It enables the visualization of a 3-dimensional dose distribution in the teeth and mandible on pCT, enhancing the understanding of the dose delivered during RT.

The study of collimator and radiation shield for the detection of the gamma-ray distribution (감마선 분포탐지를 위한 조사구 및 차폐체에 관한 연구)

  • Hwang, Young-gwan;Lee, Nam-ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.944-945
    • /
    • 2016
  • Gamma-ray Detector for gamma-ray imaging device is composed of a shielding body for shielding gamma-rays incident from the radiation source. Distribution of the gamma ray can be represented by the distribution information on the direction in which the detecting section and the signal through the incident hole of collimator. The role of the shield is important because all signals should be treated as noise except for the signal from the incident hole.In this paper In this paper, we have produced a compact, lightweight and Collimator shield by changing the structure and physical properties with respect to the collimator and shielding of lead-based gamma-ray detectors. And we analyzed the shielding effectiveness relative to the incident gamma ray sphere measured signal value through the gamma irradiation test facility. The results confirmed that the production and Collimator shielding the imaging device Implementing more efficient to implement.

  • PDF

In-Service Identification of the Heterogeneous Zone in Petrochemical Pipelines by Using Sealed Gamma-Ray Sources $(^{60}Co,\;^{137}Cs)$

  • Kim, Jin-Seop;Jung, Sung-Hee;Kim, Jong-Bum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.3
    • /
    • pp.169-173
    • /
    • 2006
  • In-service diagnoses of pipeline facilities are important for a systematic maintenance of them. Field applications by using sealed gamma-ray sources $(^{60}Co,\;^{137}Cs)$ were performed to identify the heterogeneous zone in the pipelines of a distillation tower and a flare stack respectively. From the results, the heterogeneous zones in the pipelines were successfully identified. In the case of the pipeline connected to the distillation tower, a vapor pocket was detected in the fluid under hydrodynamic conditions, which could explain the reason for a decrease of the flow rate. In another case, an area with some amount of catalyst deposits was found at the bottom of the gas pipeline which was connected to the flare stack. And these findings provided important information for the process operators. Diagnosis technique by using gamma radiation sources has been proven to be an effective and reliable method for providing information on a media distribution in a facility.