• Title/Summary/Keyword: Radiation industry

Search Result 709, Processing Time 0.03 seconds

A Study on Protection Performance of Radiation Protective Aprons classified by Manufacturers and Lead Equivalent using Over Tube Type Fluoroscopy (Over Tube Type의 투시촬영장치를 이용한 제조사별, 납당량별 엑스선방어 앞치마의 Protection 성능 평가에 관한 연구)

  • Song, Jong-Nam;Seol, Gwang-Wook;Hong, Seong-Il;Choi, Jeong-Gu
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.135-141
    • /
    • 2011
  • If protective performance of apron cannot be good, radiation exposure of an guardian or a patient, a person engaged in radiation related industry cannot rise. Therefore, It will be evaluated protection performance to radiation protection aprons by manufacturers and lead equivalent more than 0.25mm lead equivalent. And, will show in the direction of application to clinic. The new aprons by manufacturers(H, X, I, J company) and lead equivalent(0.50mmPb, 0.35mmPb, 0.25mmPb) measured transmitted dose rate and shielding rate, uniformity under fluoroscopy and general radiography using to fluoroscopy system and digital radiography system, x-ray multifunction meter. The shielding rate measurement results, 0.5mmPb apron was Shielding rate of apron of a I company(fluoroscopy : 97.96%) was the best under six companies, and shielding rate of apron of a J company(fluoroscopy : 96.25%) was worst. 0.35mmPb Apron was Shielding rate of a I company(fluoroscopy : 96.79%) was the best under the three companies, and shielding rate of an H company(fluoroscopy : 95.81%) was the worst. 0.25mmPb Apron was Shielding rate of X company apron(fluoroscopy : 90.908%) was better than H company apron(fluoroscopy : 88.82%) than two companies. The uniformity measurement results, 0.5mmPb Aprons of X company(fluoroscopy : 0.13) and I company(fluoroscopy : 0.19) was the best under the six companies, and J company apron(fluoroscopy : 0.45) was the worst. 0.35mmPb. Along a manufacturer and lead equivalent performance of apron protection is distinguished certainly. Therefore, a patient, guardian or a person engaged in radiation related industry shall enforce experiment of a lot of ways defined or evaluation so that the maximum reduces radiation exposure. Buy the apron that protective performance is good, It will be performed through experiment and evaluation.

Detection Characteristics of PSL and TL Methods in Spices Irradiated with Different Radiation Sources (조사선원에 따른 향신료의 PSL과 TL 검지 특성)

  • Kim, Kyu-Heon;Kwak, Ji-Young;Kim, Jung-Ki;Hwang, Cho-Rong;Lee, Jae-Hwang;Park, Yong-Chjun;Kim, Jae-I;Jo, Tae-Yong;Lee, Hwa-Jung;Lee, Sang-Jae;Han, Sang-Bae
    • Journal of Radiation Industry
    • /
    • v.7 no.1
    • /
    • pp.15-21
    • /
    • 2013
  • The detection characteristics of irradiated spices were investigated depending on radiation sources and doses by photostimulated luminescence (PSL) and Thermoluminescence (TL). 6 kinds of spices (turmeric, onion powder, red pepper, basil, parsley, black pepper) were irradiated at 0 to 10 kGy under ambient conditions by both a $^{60}Co$ gamma irradiator and an electron beam (EB) accelerator, respectively. The PSL analysis showed negative results for non-irradiated spices, while irradiated spices gave intermediate and positive value, which presented the limited potential of PSL technique. In TL measurement, TL glow curves on non-irradiated samples appeared at about $300^{\circ}C$ with low intensity. All irradiated samples were easily distinguishable through radiation-specific strong TL glow curves with maximum peak in range of $150{\sim}200^{\circ}C$. TL ratio ($TL_1/TL_2$) obtained by a re-irradiation step could verify the detection result of $TL_1$ glow curves, showing ratios lower than 0.1 in the non-irradiated sample and higher than 0.1 in irradiated ones. Therefore, in PSL measurement, the identification of irradiated spices showed more clear results in electron beam irradiated samples. TL analysis showed obvious difference between non-irradiated and irradiated samples in gamma ray and electron beam irradiated samples.

Diagnosis of the Liquid Transportation Pipe in the Petroleum Industry using Sealed Gamma-ray Source(137Cs) (밀봉감마선원(137Cs)을 이용한 석유화학산업의 유체이송배관 내 가동 중 이상 진단기술)

  • Kim, Jin-Seop;Jung, Sung-Hee;Kim, Jong-Bum
    • Applied Chemistry for Engineering
    • /
    • v.16 no.6
    • /
    • pp.794-799
    • /
    • 2005
  • With the quantitative growth of the petroleum industry, the pipe facilities that connect each process increased significantly and the corresponding maintenance and repair costs of the pipe facilities increased as well. The diagnosis techniques to check a pipe efficiency while in operation are few in Korea, but in the advanced countries the pipe diagnosis using gramma-ray source was on-going research since 1960's. In this study, field experiments were performed to analyze the reasons for abnormal operation of the pipe connected to a distillation tower, and the degree of abnormality was estimated using a sealed gamma-ray source ($^{137}Cs$). Gamma radiation counts were measured by a detector (NaI) positioned outside the pipe-wall diametrically opposite to the gamma source. The results showed that a gas zone section's distribution pattern was different from the pattern of nearby fluid in a pipe. Th diagnosis technique using a gamma radiation source was proved to be an effective and reliable method, offering the information on the fluid distribution in pipe.

Performance Evaluation of Aprons according to Lead Equivalent and Form Types (방사선 방어용 앞치마의 납당량, 형태에 따른 성능 평가)

  • Kim, Ki-Won;Choi, Sung-Hyun;Kim, Ki-Yeol;Lee, Ik-Pyo;Hwang, Sun-Gwang;Dong, Kyung-Rae
    • Journal of Radiation Industry
    • /
    • v.10 no.4
    • /
    • pp.219-225
    • /
    • 2016
  • The apron is one of the essential protectors to reduce the exposure dose of radiological technologists. This study is to provide a guideline for purchasing the aprons with excellent performance and to help reducing the exposure dose by measuring the shielding ration and uniformity of aprons according to lead equivalent and form types. The shielding ratio of aprons were measured by using radiation generator and dosimeter. Exposure conditions were 81 kVp, 25 mAs, source to image receptor distance (SID) 100 cm and field of view (FOV) $17^{{\prime}{\prime}}{\times}17^{{\prime}{\prime}}$. Exposure areas for front type and around type aprons were divided into 9 areas and for 2 pieces type aprons were divided into 3 areas of top and 4 areas of skirt. The uniformity of aprons were measured by using fluoroscopy and Image J. The 4 regions of interest (ROI) were set into acquired images and measured uniformity by measuring the standard deviation of pixel intensity in ROIs. In continuous shielding ration measurement of aprons according to exposure area, there was not statistical significance (P>0.05). In ANOVA test of aprons, there was statistical significance (P<0.01). In the results of sheilding ratio, although the aprons had equal lead equivalent, there were difference in shielding ratio from 83.59% to 98.15%. In the results of uniformity, the front type aprons with equal lead equivalent indicated the similar uniformity. However, the around type and 2 pieces type apron with equal lead equivalent indicated the different uniformity each other, from 1.8 to 22.2. If the performance evaluation in this study were conducted regularly before and after purchase the aprons, the exposure does to patients and radiological technologists could be reduced.

Usability Evaluation through Gonad Shielding Production of Pediatric Patients by Gender and Age Rating (소아 환자의 성별과 연령별 생식선 차폐체 제작을 통한 유용성 평가)

  • CHOI, Sung-Hyun;PARK, Jung-Eun;Dong, Kyung-Rae;Chung, Woon-Kwan;Ju, Yong-Jin;Yang, Nam-Hee
    • Journal of Radiation Industry
    • /
    • v.9 no.2
    • /
    • pp.69-75
    • /
    • 2015
  • Purpose: The gonad shielding is used to minimize the impact of the exposure to gonads when Abdomen, Pevis and Hip X-ray inspections are conducted on radiation impressionable pediatric patients. By the way, the gonad is palpable difficult and impossible to check visually because it's a sensitive area, so tests are conducted with the approximate location of shielding, thereby appearing problems of not shielding gonads accurately. Accordingly, this study produced shields by age and gender of pediatric patients and studied the method of positioning shields with ASIS as a reference point without palpable sensitive areas, and tried to evaluate its usability. Materials and methods: The study surveyed 30 pediatric patients by gender and age, who came and got inspected in Department of Radiology, our hospital from February 2012 to January 2014 and obtained the value of tolerance by measuring the average size of the pelvis using the distance measurement function of Infinitt Piview with the images stored in the PACS and producing shields by age and gender of pediatric patients and specifying the areas at random for the comparative analysis of pre- and post-using. It calculated the technology statistics($mean{\pm}SD$) with the value of tolerance measured the length using SPSS 12.0 statistical program. Results: As for boys, differences in the tolerance range of pre- and post-using shields were 2.69 mm in case of 1 year old, 2.58 mm in 2 years, 2.37 mm in 3 years, 2.815 mm in 4~5 years, 2.043 mm in 7~10 years, and as for girls, 1.92 mm in 1~2 years, 1.75 mm in 3~4 years, 2.52 mm in 5~6 years and 1.93 mm in 7~10. After analyzing the pre- and post-using shields for all of boys and girls, there were statistically significant differences(P<0.050). Conclusions: It is considered that we can minimize the exposure to gonads and get a better video for diagnosis in testing high biological impressionable pediatric, if we use shields correctly with ASIS as a reference point considering its shape and size by age and gender in Abdomen, Pevis and Hip X-ray inspections.

Characteristics of Mutant Lines through M6 to M7 Generation Induced by Radiation in Rapeseed (Brassica napus L.) (방사선 조사에 의한 유채 M6~M7세대 변이계통의 특성)

  • Kim, Jun-Su;Eun, Jong-Seon
    • Journal of Radiation Industry
    • /
    • v.7 no.2_3
    • /
    • pp.101-108
    • /
    • 2013
  • To develop new varieties of rapeseed (Brassica napus L.), the seeds of three varieties, 'Naehan', 'Tammi', and 'Halla' were irradiated with proton ion beams and gamma rays with 0 to 2,000 Gy. We had selected 9 lines in $M_5$ generation, and their useful characteristics were investigated by progressing from $M_6$ to $M_7$ generation for checking uniformity and stability. The 9 lines selected in $M_5$ generation were maintained their characteristics in terms of flowering date, maturing date, and plant height through $M_6$ to $M_7$ generations. Especially, 2 lines of NP600-1-1-198-2-1 and NP1000-13-2-362-4-1 selected in $M_5$ generation derived from 'Naehan' had characteristics of early maturity and shorter stem than original variety, and they also were maintained characteristic of early maturity such as 10~11 days earlier flowering date and 6~9 days earlier maturing date through $M_6$ to $M_7$ generations. For stem length, they showed characteristics of shorter stem in 2 lines of NP600-1-1-198-2-1 line and NP1000-13-2-362-4-1 line about 16%, 25% shorter stem than original variety respectively through $M_6$ to $M_7$ generations. Furthermore, some characteristics of 2 lines compared to the original variety were similar or higher in weight of 1,000 seeds, number of branches per plant, number of siliqua per panicle, number of seeds per silique, oil contents, and oleic acid contents. The line with large and plump flowers selected in $M_5$ generation also showed large and dark yellow flowers through $M_6$ to $M_7$ generations. The lines with High oleic acid and low saturated fatty acid contents selected in $M_5$ generation were maintained characteristics through $M_6$ to $M_7$ generation and these useful characteristics were expected for developing a new variety for bio diesel uses.

A Study of Wind Characteristics around Nuclear Power Plants Based on the Joint Distribution of the Wind Direction and Wind Speed

  • Yunjong Lee
    • Journal of Radiation Industry
    • /
    • v.17 no.3
    • /
    • pp.299-307
    • /
    • 2023
  • Given that toxic substances are diffused by the various movements of the atmosphere, it is very important to evaluate the risks associated with this phenomenon. When analyzing the behavioral characteristics of these atmospheric diffusion models, the main input data are the wind speed and wind direction among the meteorological data. In particular, it is known that a certain wind direction occurs in summer and winter in Korea under the influence of westerlies and monsoons. In this study, synoptic meteorological observation data provided by the Korea Meteorological Administration were analyzed from January 1, 2012 to the end of August of 2022 to understand the regional wind characteristics of nuclear power plants and surrounding areas. The selected target areas consisted of 16 weather stations around the Hanbit, Kori, Wolsong, Hanul, and Saeul nuclear power plants that are currently in operation. The analysis was based on the temperature, wind direction, and wind speed data at those locations. Average, maximum, minimum, median, and mode values were analyzed using long-term annual temperature, wind speed, and wind direction data. Correlation coefficient values were also analyzed to determine the linear relationships among the temperature, wind direction, and wind speed. Among the 16 districts, Uljin had the highest wind speed. The median wind speed values for each region were lower than the average wind speed values. For regions where the average wind speed exceeds the median wind speed, Yeongju, Gochang, Gyeongju, Yeonggwang, and Gimhae were calculated as 0.69 m s-1, 0.54m s-1, 0.45m s-1, 0.4m s-1, and 0.36m s-1, respectively. The average temperature in the 16 regions was 13.52 degrees Celsius; the median temperature was 14.31 degrees and the mode temperature was 20.69 degrees. The average regional temperature standard deviation was calculated and found to be 9.83 degrees. The maximum summer temperatures were 39.7, 39.5, and 39.3 in Yeongdeok, Pohang, and Yeongcheon, respectively. The wind directions and speeds in the 16 regions were plotted as a wind rose graph, and the characteristics of the wind direction and speed of each region were investigated. It was found that there is a dominant wind direction correlated with the topographical characteristics in each region. However, the linear relationship between the wind speed and direction by region varied from 0.53 to 0.07. Through this study, by evaluating meteorological observation data on a long-term synoptic scale of ten years, regional characteristics were found.

In-Situ Gamma Spectrometry Research Analysis and Radiation Efficiency Sensitivity Evaluation (감마핵종 In-Situ 측정 연구 동향 분석 및 방사능 측정 효율 민감도 평가)

  • Hyun Jun Na;Hyeok Jae Kim;Seong Yeon Lee;Min Woo Kwak;Kwang Pyo Kim
    • Journal of Radiation Industry
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • Since a large amount of radioactive waste is expected to be generated due to permanent shutdown of many nuclear power plants, it is necessary to prepare efficient management methods for radioactive waste. Therefore, there is a need for a based study to apply the In-Situ gamma spectrometry, which can simplify the measurement procedure. The purpose of this study is to analyze research cases of In-Situ gamma spectrometry and to analyze the sensitivity of measurement according to influencing factors on In-Situ gamma spectrometry. Research cases of five institutions, including the CERN and the Imperial College Reactor Centre (ICRC), were selected as the institutions to be investigated. Research on the In-Situ gamma spectrometry was conducted on the satisfaction of the acceptance criteria for radioactive waste and the analysis of residual radioactivity in the site. In-Situ Objective Counting System (ISOCS) was used as a major measuring device. Sampling and computer code were used to verify the analysis results. For evaluation of measuring sensitivity according to influencing factors on In-Situ gamma spectrometry, the thickness of the measurement target, the distance between the detector and the target, the angle of the collimator, and the contamination location were performed using ISOCS's Geometry Composer. In every case, based on 122 keV, the efficiency decreased as the energy increased in the high energy region, and the efficiency decreased as the energy decreased in the low energy region. As the target thickness increased, the efficiency decreased, and as the distance between target and detector increased, the efficiency decreased. As the distance between contamination and detector increased, the efficiency decreased, and as the angle of the collimator increased, the measurement efficiency increased. However, when simulating the measurement situation using Geometry Composer, the background is not considered, and the probability of incident in the background increases as the angle increases, so further research needs to be conducted in consideration of these. This study can be utilized when applying the In-Situ gamma spectrometry of radioactive waste clearance in the future.

Combination of red ginseng and velvet antler extracts prevents skin damage by enhancing the antioxidant defense system and inhibiting MAPK/AP-1/NF-κB and caspase signaling pathways in UVB-irradiated HaCaT keratinocytes and SKH-1 hairless mice

  • Van-Long Truong;Yeon-Ji Bae;Ji-Hong Bang;Woo-Sik Jeong
    • Journal of Ginseng Research
    • /
    • v.48 no.3
    • /
    • pp.323-332
    • /
    • 2024
  • Background: Studies have reported that the combination of two or more therapeutic compounds at certain ratios has more noticeable pharmaceutical properties than single compounds and requires reduced dosage of each agent. Red ginseng and velvet antler have been extensively used in boosting immunity and physical strength and preventing diseases. Thus, this study was conducted to elucidate the skin-protective potentials of red ginseng extract (RGE) and velvet antler extract (VAE) alone or in combination on ultraviolet (UVB)-irradiated human keratinocytes and SKH-1 hairless mice. Methods: HaCaT cells were preincubated with RGE/VAE alone or in combination for 2 h before UVB (30 mJ/cm2) irradiation. SKH-1 mice were orally given RGE/VAE alone or in combination for 15 days before exposure to single dose of UVB (600 mJ/cm2). Treated cells and treated skin tissues were collected and subjected to subsequent experiments. Results: RGE/VAE pretreatment alone or in combination significantly prevented UVB-induced cell death, apoptosis, reactive oxygen species production, and DNA damage in keratinocytes and SKH-1 mouse skins by downregulating mitogen-activated protein kinases/activator protein 1/nuclear factor kappa B and caspase signaling pathways. These extracts also strengthened the antioxidant defense systems and skin barriers in UVB-irradiated HaCaT cells and SKH-1 mouse skins. Furthermore, RGE/VAE co-administration appeared to be more effective in preventing UVB-caused skin injury than these extracts used alone. Conclusion: Overall, these findings suggest that the consumption of RGE/VAE, especially in combination, offers a protective ability against UVB-caused skin injury by preventing inflammation and apoptosis and enhancing antioxidant capacity.

Effects of drying methods on quality characteristics and antioxidative effects of Omija (Schizandra chinesis bailon) (건조방법을 달리한 오미자의 품질특성 및 항산화 효과)

  • Lee, Seul;Moon, Hey-Kyung;Lee, Su-Won;Moon, Jae-Nam;Kim, Jong-Kuk
    • Food Science and Preservation
    • /
    • v.21 no.3
    • /
    • pp.341-349
    • /
    • 2014
  • The antioxidative effect and quality characteristics of different drying methods (hot air drying, far-infrared radiation drying, vacuum freeze drying) from Schizandra Chinensis Baillon were investigated. The moisture contents and water activity(Aw) contents each 4.46% and 0.38 values of the vacuum freeze drying were lower than those of other samples. A significant not difference in pH values occurred in all samples (p<0.05). The highest content $^{\circ}brix$ vacuum freeze drying was $6.60^{\circ}Brix$ respectively. The turbidity values of the samples were hot air drying 8.24 T%, far infrared radiation drying 0.32 T%, vacuum freeze drying 71.85 T%. The Hunter's L, a and b values of vacuum freeze drying were higher than those of other samples. The order of the free sugar content was glucose>fructose>sucrose, and that of the total free sugar contents were vacuum freeze drying (6.33 g/100 g) > far infrared drying (5.01 g/100 g) > hot air drying (3.73 g/100g). Antioxidant acitivy (DPPH radical scavenging, ABTS radical scavenging) and total phenol, total flavonoid, and total tannin content was highest in vaccum freeze drying than other different drying methods except nitrite scavenging ability.