• Title/Summary/Keyword: Radiation flux

Search Result 562, Processing Time 0.027 seconds

Target-Moderator-Reflector system for 10-30 MeV proton accelerator-driven compact thermal neutron source: Conceptual design and neutronic characterization

  • Jeon, Byoungil;Kim, Jongyul;Lee, Eunjoong;Moon, Myungkook;Cho, Sangjin;Cho, Gyuseong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.3
    • /
    • pp.633-646
    • /
    • 2020
  • Imaging and scattering techniques using thermal neutrons allow to analyze complex specimens in scientific and industrial researches. Owing to this advantage, there have been a considerable demand for neutron facilities in the industrial sector. Among neutron sources, an accelerator driven compact neutron source is the only one that can satisfy the various requirements-construction budget, facility size, and required neutron flux-of industrial applications. In this paper, a target, moderator, and reflector (TMR) system for low-energy proton-accelerator driven compact thermal neutron source was designed via Monte Carlo simulations. For 10-30 MeV proton beams, the optimal conditions of the beryllium target were determined by considering the neutron yield and the blistering of the target. For a non-borated polyethylene moderator, the neutronic properties were verified based on its thickness. For a reflector, three candidates-light water, beryllium, and graphite-were considered as reflector materials, and the optimal conditions were identified. The results verified that the neutronic intensity varied in the order beryllium > light water > graphite, the compacter size in the order light water < beryllium < graphite and the shorter emission time in the order graphite < light water < beryllium. The performance of the designed TMR system was compared with that of existing facilities and were laid between performance of existing facilities.

THE ADAPTATION METHOD IN THE MONTE CARLO SIMULATION FOR COMPUTED TOMOGRAPHY

  • LEE, HYOUNGGUN;YOON, CHANGYEON;CHO, SEUNGRYONG;PARK, SUNG HO;LEE, WONHO
    • Nuclear Engineering and Technology
    • /
    • v.47 no.4
    • /
    • pp.472-478
    • /
    • 2015
  • The patient dose incurred from diagnostic procedures during advanced radiotherapy has become an important issue. Many researchers in medical physics are using computational simulations to calculate complex parameters in experiments. However, extended computation times make it difficult for personal computers to run the conventional Monte Carlo method to simulate radiological images with high-flux photons such as images produced by computed tomography (CT). To minimize the computation time without degrading imaging quality, we applied a deterministic adaptation to the Monte Carlo calculation and verified its effectiveness by simulating CT image reconstruction for an image evaluation phantom (Catphan; Phantom Laboratory, New York NY, USA) and a human-like voxel phantom (KTMAN-2) (Los Alamos National Laboratory, Los Alamos, NM, USA). For the deterministic adaptation, the relationship between iteration numbers and the simulations was estimated and the option to simulate scattered radiation was evaluated. The processing times of simulations using the adaptive method were at least 500 times faster than those using a conventional statistical process. In addition, compared with the conventional statistical method, the adaptive method provided images that were more similar to the experimental images, which proved that the adaptive method was highly effective for a simulation that requires a large number of iterations-assuming no radiation scattering in the vicinity of detectors minimized artifacts in the reconstructed image.

The Impact of Interaction between Cloud and Longwave Radiation on the Asian Monsoon Circulation (구름-장파복사 상호작용이 아시아 몬순에 미치는 영향)

  • Ryu, Geun-Hyeok;Sohn, Byung-Ju
    • Journal of the Korean earth science society
    • /
    • v.30 no.1
    • /
    • pp.58-68
    • /
    • 2009
  • Three-dimensional distributions of longwave radiation flux for the April-September 1998 period are generated from radiative transfer calculations using the GEWEX Asian Monsoon Experiment (GAME) reanalysis temperature and humidity profiles and International Satellite Cloud Climatology Project (ISCCP) cloudiness as inputs to understand the effect of cloud radiative forcing in the monsoon season. By subtracting the heating of the clear atmosphere from the cloudy radiative heating, cloud-induced atmospheric radiative heating has been obtained. Emphasis is placed on the impact of horizontal gradients of the cloud-generated radiative heating on the Asian monsoon. Cloud-induced heating exhibits its maximum heating areas within the Indian Ocean and minimum heating over the Tibetan Plateau, which establishes the north-south oriented differential heating gradient. Considering that the differential heating is a ultimate source generating the atmospheric circulation, the cloud-induced heating gradient established between the Indian Ocean and the Plateau can enhance the strength of the north-south Hadley-type monsoon circulation. Cooling at cloud top and warming at cloud bottom, which are the vertical distributions of cloud-induced heating, can exert on the monsoon circulation by altering the atmospheric stability.

Development Treatment Planning System Based on Monte-Carlo Simulation for Boron Neutron Capture Therapy

  • Kim, Moo-Sub;Kubo, Kazuki;Monzen, Hajime;Yoon, Do-Kun;Shin, Han-Back;Kim, Sunmi;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.232-235
    • /
    • 2016
  • The purpose of this study is to develop the treatment planning system (TPS) based on Monte-Carlo simulation for BNCT. In this paper, we will propose a method for dose estimation by Monte-Carlo simulation using the CT image, and will evaluate the accuracy of dose estimation of this TPS. The complicated geometry like a human body allows defining using the lattice function in MCNPX. The results of simulation such as flux or energy deposition averaged over a cell, can be obtained using the features of the tally provided by MCNPX. To assess the dose distribution and therapeutic effect, dose distribution was displayed on the CT image, and dose volume histogram (DVH) was employed in our developed system. The therapeutic effect can be efficiently evaluated by these evaluation tool. Our developed TPS could be effectively performed creating the voxel model from CT image, the estimation of each dose component, and evaluation of the BNCT plan.

Optimization of Energy Modulation Filter for Dual Energy CBCT Using Geant4 Monte-Carlo Simulation

  • Ju, Eun Bin;Ahn, So Hyun;Choi, Sang Gyu;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.3
    • /
    • pp.125-130
    • /
    • 2016
  • Dual energy computed tomography (DECT) is used to classify two materials and quantify the mass density of each material in the human body. An energy modulation filter based DECT could acquire two images, which are generated by the low- and high-energy photon spectra, in one scan, with one tube and detector. In the case of DECT using the energy modulation filter, the filter should perform the optimization process for the type of materials and thicknesses for generating two photon spectra. In this study, Geant4 Monte-Carlo simulation toolkit was used to execute the optimization process for determining the property of the energy modulation filter. In the process, various materials used for the energy modulation filter are copper (Cu, $8.96g/cm^3$), niobium (Nb, $8.57g/cm^3$), stannum (Sn, $7.31g/cm^3$), gold (Au, $19.32g/cm^3$), and lead (Pb, $11.34g/cm^3$). The thickness of the modulation filter varied from 0.1 mm to 1.0 mm. To evaluate the overlap region of the low- and high-energy spectrum, Geant4 Monte-Carlo simulation is used. The variation of the photon flux and the mean energy of photon spectrum that passes through the energy modulation filter are evaluated. In the primary photon spectrum of 80 kVp, the optimal modulation filter is a 0.1 mm lead filter that can acquire the same mean energy of 140 kVp photon spectrum. The lead filter of 0.1 mm based dual energy CBCT is required to increase the tube current 4.37 times than the original tube current owing to the 77.1% attenuation in the filter.

Studies on Preparation of Dysprosium-165 Metallic Macroaggregates for the Treatment of Rheumatoid Arthritis (류마티스 관절염 치료용 디스프로슘-165금속 응집입자($^{165}Dy-MA$)의 제조에 관한 연구)

  • Park, Kyung-Bae;Kim, Jae-Rok
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.227-233
    • /
    • 1994
  • Irradiation of 20mg of natural $Dy(NO_3)_3$ in a neutron flux of $2{\times}10^{13}n/cm^2$ sec for 4 hours gave 5.76 Ci of $^{165}Dy$(specific activity, 610mCi/mg Dy) with high radionuclidic purity (>99.9 %). $^{165}Dy-MA$ was prepared in a quantitative yield by reacting the aqueous solution of $^{165}Dy(NO_3)_3$ with sodium borohydride solution in 0.2N NaOH. Coulter particle analyzer exhibited mean particle size of $2.6{\mu}m$ (range $1{\sim}6{\mu}m$), Even though the $^{165}Dy-MA$ suspension in saline was stored at $37^{\circ}C$ for 24 hours or autoclaved at $121^{\circ}C$ for 30minutes, there was no significant change in particle size and leakage problem indicating the prepared $^{165}Dy-MA$ is sufficiently stable. In-vivo retention studies were carried out by administering $^{165}Dy-MA$ into the knee joint space of normal rabbits. Gamma camera analysis showed high retention in joint space of normal rabbits. Gamma camera analysis showed high retention in joint space even at 24 hours after administration (> 99.9%). The ease with which the $^{165}Dy-MA$ can be made in the narrow size range and their high invitro and vivo stability make them attractive agents for radiation synovectomy.

  • PDF

Field Intercomparison and Calibration of Net Radiometers (순복사계의 야외 상호 비교 및 보정)

  • Byung-Kwan Moon;Sang-Boom Ryoo;Yong-Hoon Youn;Jonghwan Lim;Joon Kim
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.5 no.2
    • /
    • pp.128-137
    • /
    • 2003
  • Net radiation (Rn) is one of the most fundamental components in surface energy budget. For an accurate measurement of Rn, periodic and consistent calibrations of net radiometers are required. With a 4-month time interval, two field experiments were conducted to inter-compare and calibrate two types of net radiometers (the Q-7.1 and the CNR1), widely used in flux measurements. Differences between the Q-7.1 and the CNR1 net radiometers were within 7.7%, and the errors after calibration against the standard net radiometer were <3.2%. Radiometric responses and calibration factors appeared to have changed with sky renditions, especially temperature difference with season's progress. We concluded that the periodically calibrated Q-7.1 can replace more expensive, more accurate CNR1 net radiometer for long-term field measurements, providing that field calibrations of net radiometers are performed every 4-6 months interval.

RADIO EMISSION FROM WEAK SPHERICAL SHOCKS IN THE OUTSKIRTS OF GALAXY CLUSTERS

  • Kang, Hyesung
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.2
    • /
    • pp.155-164
    • /
    • 2015
  • In Kang (2015) we calculated the acceleration of cosmic-ray electrons at weak spherical shocks that are expected to form in the cluster outskirts, and estimated the diffuse synchrotron radiation emitted by those electrons. There we demonstrated that, at decelerating spherical shocks, the volume integrated spectra of both electrons and radiation deviate significantly from the test-particle power-laws predicted for constant planar shocks, because the shock compression ratio and the flux of inject electrons decrease in time. In this study, we consider spherical blast waves propagating through a constant density core surrounded by an isothermal halo with ρ ∝ r−n in order to explore how the deceleration of the shock affects the radio emission from accelerated electrons. The surface brightness profile and the volumeintegrated radio spectrum of the model shocks are calculated by assuming a ribbon-like shock surface on a spherical shell and the associated downstream region of relativistic electrons. If the postshock magnetic field strength is about 0.7 or 7 µG, at the shock age of ∼ 50 Myr, the volume-integrated radio spectrum steepens gradually with the spectral index from αinj to αinj + 0.5 over 0.1–10 GHz, where αinj is the injection index at the shock position expected from the diffusive shock acceleration theory. Such gradual steepening could explain the curved radio spectrum of the radio relic in cluster A2266, which was interpreted as a broken power-law by Trasatti et al. (2015), if the relic shock is young enough so that the break frequency is around 1 GHz.

Influence of Surrounding Gas and Coal Characteristics on Flame Propagation in Oxy-Fuel Combustion of Pulverized Coal (미분탄 순산소 연소에서 주위 기체와 석탄 특성이 화염전파에 미치는 영향)

  • Kang, Young-Min;Shim, Young-Sam;Moon, Cheor-Eon;Sung, Yon-Mo;Seo, Sang-Il;Kim, Tae-Hyung;Choi, Gyung-Min;Kim, Duck-Jool
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.1
    • /
    • pp.38-45
    • /
    • 2009
  • Oxy-fuel combustion of pulverized coal is one of the promising new technologies to reduce $CO_2$ and NOx from coal combustion. However, the stability of pulverized coal flame is reduced in the oxy-fuel combustion. This flame stability is concerned with the flame propagation that is affected by surrounding gas and coal characteristics, such as gas temperature, gas composition, coal volatile, coal activation energy and coal size. In this paper, a study on the influence of surrounding gas and coal characteristics on the flame propagation velocity in oxy-fuel combustion of pulverized coal was preformed. One dimensional model was used to calculate the flame propagation velocity of pulverized coal clouds. In this model, the radiation is considered to be the main source of heat exchange, and Monte Carlo method was adopted for accurate calculation of radiation heat flux. It was found that the flame propagation velocity become higher with the decrease of coal activation energy and the increase of coal volatile. Also, according to the increase of gas temperature and $O_2$ concentration, flame propagation velocity increased.

Capture of Metal Ions by Cross-linked Sulfonic Acid Type Ion Exchange Membranes (가교제를 도입시킨 술폰산형 이온교환막의 금속이온 포집)

  • Kim, Min;Kim, Ye-Jin;Park, Sang-Jin
    • Membrane Journal
    • /
    • v.19 no.4
    • /
    • pp.333-340
    • /
    • 2009
  • This paper is designed with the purpose of improving the efficiency of the sulfonic acid ion exchange membranes by radiation induced graft polymerization. It has been shown that the porous hollow fiber membranes could cause permeability blocking between pores and ion exchanged graft chains. Addition of crosslinker such as N-ethylene glycol dimethacrylate will permit to increase the permeation flux. In this research, the ethylene glycol dimethacrylate (EDMA) and diethylene glycol dimethacrylate (DDMA) with different length are used as crosslinkers. The ion exchanged cross-linked membrane (EDMA, DDMA) containing sulfonic acid group by radiation induced grafted polymerization are sn died for adsorb metal ions (Pb). It has been shown that adsorbed metal ions ($Pb^{2+}$) for the EDMA and DDMA membranes with the density of sulfonic acid groups, 1.40 mmol/g and 2.14 mmol/g, respectively are 13.82 mg/g, 17.37 mg/g, accordingly.