THE ADAPTATION METHOD IN THE MONTE CARLO SIMULATION FOR COMPUTED TOMOGRAPHY |
LEE, HYOUNGGUN
(Department of Bio-convergence Engineering, Korea University)
YOON, CHANGYEON (Department of Bio-convergence Engineering, Korea University) CHO, SEUNGRYONG (Department of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology) PARK, SUNG HO (Department of Neurosurgery, Ulsan University Hospital) LEE, WONHO (Department of Bio-convergence Engineering, Korea University) |
1 | American Association of Physicists in Medicine (AAPM), Medical physics: the management of imaging dose during image-guided radiotherapy: report Task Group 75, AAPM Task Group 75, Med. Phys. 34 (2007) 4041. DOI |
2 | E.J. Hall, C.S. Wuu, Radiation-induced second cancers: the impact of 3D-CRT and IMRT, Int. J. Radiat. Oncol. Biol. Phys. 56 (2003) 83-88. DOI |
3 |
A.D. Lazarine, Medical Physics Calculations with MCNP: |
4 | C.R. Harrell, I.G. Zubal, Effect of Variance Reduction Techniques on Monte Carlo Simulated Energy Spectra. Bioengineering Conference, Proceedings of the 1991 IEEE Seventeenth Annual Northeast (Hartford, Connecticut), IEEE, New York, NY, 1991, pp. 97-98. |
5 | D. Sarrut, L.L. Gulgues, Region-oriented CT image representation for reducing computing time of Monte Carlo simulations, Med. Phys. 35 (2008) 1452-1463. DOI |
6 | D.E. Peplow, K. Verghese, Digital mammography image simulation using Monte Carlo, Med. Phys. 27 (2000) 568-579. DOI |
7 | J. Allison, K. Amako, J. Apostolakis, H. Araujo, P. Arce Dubois, M. Asai, G. Barrand, R. Capra, S. Chauvie, R. Chytracek, G.A.P. Cirrone, G.D. Cooperman, G. Cosmo, G. Cuttone, G.G. Daquino, M. Donszelmann, M. Dressel, G. Folger, F. Foppiano, J. Generowicz, V. Grichine, S. Guatelli, P. Gumplinger, A. Heikkinen, I. Hrivnacova, A. Howard, S. Incerti, V. Ivanchenko, T. Johnson, F. Jones, T. Koi, R. Kokoulin, M. Kossov, H. Kurashige, V. Lara, S. Larsson, F. Lei, O. Link, F. Longo, M. Maire, A. Mantero, B. Mascialino, I. McLaren, P. Mendez Lorenzo, K. Minamimoto, K. Murakami, P. Nieminen, L. Pandola, S. Parlati, L. Peralta, J. Perl, A. Pfeiffer, M.G. Pia, A. Ribon, P. Rodrigues, G. Russo, S. Sadilov, G. Santin, T. Sasaki, D. Smith, N. Starkov, S. Tanaka, E. Tcherniaev, B. Tome, A. Trindade, P. Truscott, L. Urban, M. Verderi, A. Walkden, J.P. Wellisch, D.C. Williams, D. Wright, H. Yoshida, Geant4 developments and applications, IEEE Trans. Nucl. Sci. 53 (2006) 270-278. DOI |
8 | J.K. Shultis, R.E. Faw, Radiation Shielding, Chapter 11, American Nuclear Society, Inc., La Grange Park, IL, 2000, pp. 415-420. |
9 | J.K. Shultis, R.E. Faw, Radiation Shielding, Chapter 11, American Nuclear Society, Inc., La Grange Park, IL, 2000, pp. 420-426. |
10 | X-5 Monte Carlo Team, MCNP-A General Monte Carlo N-particle Transport Code, Version 5, Los Alamos National Laboratory, Los Alamos, NM, 2003. |
11 | K. Cranley, B.J. Gilmore, G.W.A. Fogarty, L. Deponds, Catalogue of Diagnostic X-ray Spectra and Other Data (IPEM Report 78), Institute of Physics and Engineering in Medicine, York, UK, 1997. |
12 |
Phantom Laboratory Inc, Catphan |
13 | C. Lee, C. Lee, S.H. Park, J.K. Lee, Development of the two Korean adult tomographic computational phantoms for organ dosimetry, Med. Phys. 33 (2006) 380-390. DOI |
14 | N. Keat, D. Platten, M. Lewis, S. Edyvean, ImPACT Scan Report 05071: Siemens Somatom Sensation Open CT Scanner Technical Evaluation. Imaging Performance Assessment of CT Scanners, Center for Evidence-based Purchasing, London, England, 2005. |
15 | A.M. Wysocka-Rabin, S. Qamhiyeh, O. Jakel, Simulation of computed tomography (CT) images using a Monte Carlo approach, Nukleonika 56 (2011) 299-304. |
16 | L.K. Wagner, P.J. Eifel, R.A. Geise, Potential biological effects following high X-ray dose interventional procedures, J. Vasc. Interv. Radiol. 5 (1994) 71-81. DOI |
![]() |