• 제목/요약/키워드: Radiation field Size

검색결과 389건 처리시간 0.025초

방사선치료시 물리학적 반음영의 검토 (Study on Physical Penumbra of Radiation Therapy)

  • 김영범;황웅구;김유현
    • 대한방사선치료학회지
    • /
    • 제6권1호
    • /
    • pp.84-88
    • /
    • 1994
  • Proper evaluation about the penumbra is very important to improve the efficacy of radiation theraphy. There are two kinds of physical penumbra, geometric penumbra and transmission penumbra. In this study, we evaluated the variation of physical penumbra according to the varing enery level, changing the field size and depth. Physical penumbra width was decreased as the source size decreased, and as the SDD increased, but the consideration about the scatter radiation and mechanical stability is an important factor. For the two adjacent beams, upper collimator should be used and especially for Co-60 unit, it is efficient to use the extended collimator.

  • PDF

악성 성상세포종 및 교모세포종의 적정 방사선 조사 영역에 대한 고찰 (Optimal Radiation Therapy Field for Malignant Astrocytoma and Glioblastoma Multiforme)

  • 조홍래;최영민
    • Radiation Oncology Journal
    • /
    • 제20권3호
    • /
    • pp.199-205
    • /
    • 2002
  • 목적 : 본 연구의 목적은 악성 성상세포종 및 교모세포종 환자들의 방사선 치료 시 가장 적절한 조사 영역을 알아 보고자 시행하였다. 대상 및 방법 : 1994년 1월부터 2000년 3월까지 악성 성상세포종 및 교모세포종으로 진단되어 수술 및 방사선 치료를 받은 후 MRI로 추적관찰이 시행된 환자 중 재발이 확인된 21 명을 대상으로 분석하였다. 원발 병소 바깥 경계에서부터 처음 재발이 확인된 병소까지의 거리를 측정하였다. 그 외에 종양의 크기, 부종의 정도, 수술 절제의 범위, 감마나이프를 이용한 정위방사선수술, 다발성 병변 등이 재발 양상에 미치는 영향에 대하여 분석을 하였다. 결과 : 총 21명 중 18명$(86\%)$이 2 cm 이내에서 재발을 하였다. 이들 중 1 cm 이내가 12명, $1\~2\;cm$ 사이의 재발이 6명이었다. 나머지 3명의 재발은 3 cm, 4 cm, 5 cm, 떨어져서 각각 재발을 하였다. 2 cm 이상 떨어져 재발한 3명은 모두 다발성 병변이 있는 환자였다. 종양의 크기, 부종의 범위, 수술 절제의 범위, 감마나이프 시행 유무에 따른 재발의 양상에 차이가 없었다. 다만 다발성 병변일 경우 더 멀리서 재발하는 경향을 보였다. 결론 : 악성 성상세포종 및 교모세포종에서 재발 양상은 원발 병소 준위의 2 cm 이내 재발이 주 재발 양상이었다. 방사선 조사영역의 넓이는 부종의 범위나, 병소의 크기, 감마 나이프 수술 등에 따라 더 넓힐 필요는 없는 것으로 판단된다. 그러나 다발성 병변의 경우에는 단일 병소보다 더 넓은 조사 범위가 필요할 것으로 생각된다.

A X-ray Tube Using Field Emitter Made by Multi-walled Carbon Nanotube Yarns

  • Kim, Hyun-Suk;Castro, Edward Joseph D.;Kwak, Seung-Im;Ju, Jin-Young;Hwang, Yong-Gyoo;Lee, Choong-Hun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.392-392
    • /
    • 2011
  • Carbon nanotubes (CNT) emitter has widely become an attractive mechanism that draws growing interests for cold cathode field emission.$^{1,2}$ CNT yarns have demonstrated its potential as excellent field emitters.$^3$ Extensive simulations were carried out in designing a CNT yarn-based cathode assembly. The focal spot size dependence on the anode surface of the geometric parameters such as axial distance of the electrostatic focus lens from the cathode and the applied bias voltages at the cathode, grid mesh and electrostatic focus lens were studied. The detailed computer simulations using Opera 3D electromagnetic software$^4$ had revealed that a remarkable size of focal spot under a focusing lens triode type set-up design was achieved. The result of this optimization simulation would then be applied for the construction of the CNT yarn based micro-focus x-ray tube with its field emission characteristics evaluated.

  • PDF

공동에 의한 6MV X선의 재선량증가 현상에 관한 연구 (A Study on Rebuildup of 6MV X-ray by the Cavity)

  • 조문준;최은경;정웅기;강위생;박찬일
    • Radiation Oncology Journal
    • /
    • 제7권1호
    • /
    • pp.113-121
    • /
    • 1989
  • The inclusion of air filled cavities in treatment fields creates a potential dosimetric problem due to the rebuildup phenomenon near the air-tissue interface using a simulated phantom, such as air gap, air cylinder, and air cavity, the amount of rebuldup along the various field sizes and air cavity dimensions was measured. The results are as follows. 1. As the field size becomes larger in comparison with the cavity size, or as the cavity size gets bigger when the field size is equal to the cavity size, rebuildup decreases. 2. When the distance between the phantom surface and the air cavity is less than 1.5cm, there is prominent rebuildup. And when the distance is more than 1.5cm, rebuildup is relatively constant, 3. The change according to the depth of the cavity is affected by the field size and the cavity size, rebuildup usually increases when the depth of the cavity increases. 4. It is suggested that tissue equivalent material should be applied on the skin to make tissue thickness over the air cavity more than 1.5cm and that the field size should include the air cavity with at least 1cm margin.

  • PDF

A Study on Effective Source-Skin Distance using Phantom in Electron Beam Therapy

  • Kim, Min-Tae;Lee, Hae-Kag;Heo, Yeong-Cheol;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • 제19권1호
    • /
    • pp.15-19
    • /
    • 2014
  • In this study, for 6-20 MeV electron beam energy occurring in a linear accelerator, the authors attempted to investigate the relation between the effective source-skin distance and the relation between the radiation field and the effective source-skin distance. The equipment used included a 6-20 MeV electron beam from a linear accelerator, and the distance was measured by a ionization chamber targeting the solid phantom. The measurement method for the effective source-skin distance according to the size of the radiation field changes the source-skin distance (100, 105, 110, 115 cm) for the electron beam energy (6, 9, 12, 16, 20 MeV). The effective source-skin distance was measured using the method proposed by Faiz Khan, measuring the dose according to each radiation field ($6{\times}6$, $10{\times}10$, $15{\times}150$, $20{\times}20cm^2$) at the maximum dose depth (1.3, 2.05, 2.7, 2.45, 1.8 cm, respectively) of each energy. In addition, the effective source-skin distance when cut-out blocks ($6{\times}6$, $10{\times}10$, $15{\times}15cm^2$) were used and the effective source-skin distance when they were not used, was measured and compared. The research results showed that the effective source-skin distance was increased according to the increase of the radiation field at the same amount of energy. In addition, the minimum distance was 60.4 cm when the 6 MeV electron beams were used with $6{\times}6$ cut-out blocks and the maximum distance was 87.2 cm when the 6 MeV electron beams were used with $20{\times}20$ cut-out blocks; thus, the largest difference between both of these was 26.8 cm. When comparing the before and after the using the $6{\times}6$ cut-out block, the difference between both was 8.2 cm in 6 MeV electron beam energy and was 2.1 cm in 20 MeV. Thus, the results showed that the difference was reduced according to an increase in the energy. In addition, in the comparative experiments performed by changing the size of the cut-out block at 6 MeV, the results showed that the source-skin distance was 8.2 cm when the size of the cut-out block was $6{\times}6$, 2.5 cm when the size of the cut-out block was $10{\times}10$, and 21.4 cm when the size of the cut-out block $15{\times}15$. In conclusion, it is recommended that the actual measurement is used for each energy and radiation field in the clinical dose measurement and for the measurement of the effective source-skin distance using cut-out blocks.

방사선치료 위치 실시간 검증시스템에 관한 연구 (A Study of Real Time Verification System or Radiation Therapy)

  • 김윤종;지영훈;이동한;이동훈;홍승홍
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.164-167
    • /
    • 1997
  • The treatment setup of patients during irradiation is an important aspect in relation to the success of radiotherapy. Imaging with the treatment beam is a widely used method or verification of the radiation field position relative to the target area, prior to or during irradiation. In this paper, Real time digital radiography system was implemented or verification of local error between simulation plan and radiation therapy machine. Portal image can be acquired by CCD camera, image board and pentium PC after therapy Radiation was converted into light by a metal/fluorescent Screen. The resulting image quality is comparable to film, so the imaging system represents a promising alternative to film as a method of verifying patient positioning in radiotherapy. Edge detection and field size measurement were also implemented and detected automatically for verification of treatment position. Field edge was added to the original image or checking the anatomical treatment verification by therapy technicians. By means of therapy efficiency improvement and decrease of Radiation side effects with these techniques, Exact Radiation treatments are expected.

  • PDF

Clinical Implications of High Definition Multileaf Collimator (HDMLC) Dosimetric Leaf Gap (DLG) Variations

  • Chang, Kyung Hwan;Ji, Yunseo;Kwak, Jungwon;Kim, Sung Woo;Jeong, Chiyoung;Cho, Byungchul;Park, Jin-hong;Yoon, Sang Min;Ahn, Seung Do;Lee, Sang-wook
    • 한국의학물리학회지:의학물리
    • /
    • 제27권3호
    • /
    • pp.111-116
    • /
    • 2016
  • This study is to evaluate the dosimetric impact of dosimetric leaf gap (DLG) and transmission factor (TF) at different measurement depths and field sizes for high definition multileaf collimator (HD MLC). Consequently, its clinical implication on dose calculation of treatment planning system was also investigated for pancreas stereotactic body radiation therapy (SBRT). The TF and DLG were measured at various depths (5, 8, 10, 12, and 15 cm) and field sizes ($6{\times}6$, $8{\times}8$, and $10{\times}10cm^2$) for various energies (6 MV, 6 MV FFF, 10 MV, 10 MV flattening filter free [FFF], and 15 MV). Fifteen pancreatic SBRT cases were enrolled in the study. For each case, the dose distribution was recomputed using a reconfigured beam model of which TF and DLG was the closest to the patient geometry, and then compared to the original plan using the results of dose-volume histograms (DVH). For 10 MV FFF photon beam, its maximum difference between 2 cm and 15 cm was within 0.9% and it is increased by 0.05% from $6{\times}6cm^2$ to $10{\times}10cm^2$ for depth of 15 cm. For 10 MV FFF photon beam, the difference in DLG between the depth of 5 cm and 15 cm is within 0.005 cm for all field sizes and its maximum difference between field size of $6{\times}6cm^2$ and $10{\times}10cm^2$ is 0.0025 cm at depth of 8 cm. TF and DLG values were dependent on the depth and field size. However, the dosimetric difference between the original and recomputed doses were found to be within an acceptable range (<0.5%). In conclusion, current beam modeling using single TF and DLG values is enough for accurate dose calculation.

Clinical significance of lymph node size in locally advanced cervical cancer treated with concurrent chemoradiotherapy

  • Oh, Jinju;Seol, Ki Ho;Choi, Youn Seok;Lee, Jeong Won;Bae, Jin Young
    • Journal of Yeungnam Medical Science
    • /
    • 제36권2호
    • /
    • pp.115-123
    • /
    • 2019
  • Background: This study aimed to assess the in-field lymph node (LN) failure rate according to LN size and to investigate effect of LN size on the survival outcome of patients with locally advanced cervical carcinoma treated with concurrent chemoradiotherapy (CCRT). Methods: A total of 310 patients with locally advanced cervical carcinoma treated with CCRT were enrolled in retrospective study. LN status was evaluated by magnetic resonance imaging. All patients received conventional external beam irradiation and high-dose rate brachytherapy, and concurrent cisplatin-based chemotherapy. In-field LN failure rate according to LN size was analyzed. Results: The median follow-up period was 83 months (range, 3-201 months). In-field LN failure rate in patients with pelvic LN size more than 10 mm was significantly higher than that in patients with pelvic LN size less than 10 mm (p<0.001). A similar finding was observed in the infield para-aortic LN (PALN) failure rate (p=0.024). The pelvic and PALN size (${\geq}10mm$) was a significant prognostic factor of overall-survival (OS) and disease-free survival rate in univariate and multivariate analyses. The OS rate was significantly different between groups according to LN size (<10 mm vs. ${\geq}10mm$). Conclusion: A LN of less than 10 mm in size in an imaging study is controlled by CCRT. On the other hand, in LN of more than 10 mm in size, the in-field LN failure rate increase and the prognosis deteriorate. Therefore, a more aggressive treatment strategy is needed.

Consideration of fractionation or field size prior to radiation therapy in patients with breast cancer and psoriasis: a case report

  • Jin Yi Hyun;So Hyun Park;Dae-Hyun Kim;Jinhyun Choi
    • Journal of Medicine and Life Science
    • /
    • 제20권2호
    • /
    • pp.89-93
    • /
    • 2023
  • We present three cases of patients with breast cancer and psoriasis who received radiotherapy following breast-conserving surgery. One patient developed an extensive flare-up of psoriasis during chemotherapy. After discontinuing chemotherapy, she received conventional radiotherapy to the ipsilateral whole breast, axillary, and supraclavicular lymph nodes with 50.4 Gy in 28 fractions and boosted with 10 Gy in five fractions to the tumor bed. Two patients received hypofractionated whole-breast radiotherapy at a total dose of 40.05-42.4 Gy in 15-16 fractions. In all three cases, there was no flare-up of psoriatic events at least 6 months after the completion of radiotherapy. We hypothesized that there is a close relationship between psoriatic events and the extent of trauma rather than the daily dose of the fraction. Therefore, we confirmed that the effect of radiotherapy on psoriatic events is minimal if the radiation field size does not exceed that of the whole breast.

Stereotactic Radiosurgery를 위한 소형 조사면의 선량측정 (Treatment Planning and Dosimetry of Small Radiation Fields for Stereotactic Radiosurgery)

  • 추성실;서창옥;노준규;정상섭
    • Radiation Oncology Journal
    • /
    • 제7권1호
    • /
    • pp.101-112
    • /
    • 1989
  • The treatment planning and dosimetry of small fields for stereotactic radiosurgery with 10 MV x-ray isocentrically mounted linear accelerator is presented. Special consideration in this study was given to the variation of absorbed dose with field size, the central axis percent depth doses and the combined moving beam dose distribution. The collimator scatter correction factors of small fields $(1\times1\~3\times3cm^2)$ were measured with ion chamber at a target chamber distance of 300cm where the projected fields were larger than the polystyrene buildup caps and it was calibrated with the tissue equivalent solid state detectors of small size (TLD, PLD, ESR and semiconductors). The central axis percent depth doses for $1\timesl\;and\;3\times3cm^2$ fields could be derived with the same acuracy by interpolating between measured values for larger fields and calculated zero area data, and it was also calibrated with semiconductor detectors. The agreement between experimental and calculated data was found to be under $2\%$ within the fields. The three dimensional dose planning of stereotactic focusing irradiation on small size tumor regions was performed with dose planning computer system (Therac 2300) and was verified with film dosimetry. The more the number of strips and the wider the angle of arc rotation, the larger were the dose delivered on tumor and the less the dose to surrounding the normal tissues. The circular cone, we designed, improves the alignment, minimizes the penumbra of the beam and formats ball shape of treatment area without stellate patterns. These dosimetric techniques can provide adequate physics background for stereotactic radiosurgery with small radiation fields and 10MV x-ray beam.

  • PDF