• Title/Summary/Keyword: Radiation exposure dose

Search Result 1,108, Processing Time 0.023 seconds

Radioprotective Effect of Red Ginseng in Irradiated Mice with ${\gamma}$-ray (생쥐에서 홍삼의 감마선조사에 의한 방어효과)

  • Seung, Ka-Yeon;Lee, Heung-Man;Kim, Jong-Sang;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.31-35
    • /
    • 2010
  • Recently, the incidents of direct or indirect radiation exposure due to increase of use of radiation or radioisotope are on the increase in medical and industrial circles. If cells are irradiated, free radicals are created through biological process, and cells are directly or indirectly damaged. This research intends to explore into the effect of saponin at the level of cell (in vitro) and entity (in vivo), using red ginseng extract "saponin", as radioprotective agent. In the experiment implemented at the level of cell (in vitro), degree of cell activity was measures by adding mouse mesenchymal stem cells "C3H/10T1/2 cells" into red ginseng extract "saponin(0, 0.05, 0.2, and 0.4 g/L)", and then the optimal concentration of saponin influencing cells was calculated, in 24, 48, 72, and 96 hours after gamma irradiation at the optimal concentration of saponin, each cell survival rate was observed through XTT assay. The best time period of cultivation for the optimal activity of C3H/10T1/2 cells was as 48 hours, and the degree of optimal activity was shown at 0.05 g/L. In 48 hours after irradiation of 5 Gy to C3H/10T1/2 cells at 0.05 g/L, the degree of activity of cells increased by 10%. In the experiment implemented at the level of entity (in vivo), red ginseng extract "saponin" at a dose of 100 mg/kg/day was injected into the abdominal cavity of six-week immature mouse for two weeks. Right after the last abdominal injection, total body irradiation of gamma rays was carried out at a dose of 5 Gy and 10 Gy. And after irradiation, the blood sample was taken, and then the number of red corpuscles was counted. In result, the decrement of experimental group treated with red ginseng extract "saponin" was 2.3 times larger than that of control group. In view of the results so far achieved, it was revealed that red ginseng extract "saponin" has a radiation exposure protection effect in the experiment implemented at the level of cell (in vitro). In case of animal experiment, the decrement of number of red corpuscles decreased. Finally, it is necessary to carry out more various researches continuously.

Analyses of the Setup Errors using on Board Imager (OBI) (On Board Imager (OBI)를 이용한 Setup Error 분석에 대한 연구)

  • Kim, Jong-Deok;Lee, Haeng-O;You, Jae-Man;Ji, Dong-Hwa;Song, Ju-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • Purpose: The accuracy and advantages of OBI(On Board Imager) against the conventional method like film and EPID for the setup error correction were evaluated with the analysis of the accumulated data which were produced in the process of setup error correction using OBI. Materials and Methods: The results of setup error correction using OBI system were analyzed for the 130 patients who had been planned for 3 dimensional conformal radiation therapy during March 2006 and May 2006. Two kilo voltage images acquired in the orthogonal direction were fused and compared with reference setup images. The setup errors in the direction of vertical, lateral, longitudinal axis were recorded and calculated the distance from the isocenter. The corrected setup error were analyzed according to the lesion and the degree of shift variations. Results: There was no setup error in the 41.5% of total analyzed patients and setup errors between 1mm and 5mm were found in the 52.3%. 6.1% patients showed the more than 5mm shift and this error were verified as a difference of setup position and the movement of patient in a treatment room. Conclusion: The setup error analysis using OBI in this study verified that the conventional setup process in accordance with the laser and field light was not enough to get rid of the setup error. The KV images acquired using OBI provided good image quality for comparing with simulation images and much lower patients' exposure dose compared with conventional method of using EPID. These advantages of OBI system which were confirmed in this study proved the accuracy and priority of OBI system in the process of IGRT(Image Guided Radiation Therapy).

  • PDF

Actual Condition of Quality Control of X-ray Imaging System in Primary Care Institution: focused on Gwangju Metropolitan City (1차 의료기관의 엑스선 발생장치 정도관리에 관한 현황조사:광주광역시 지역을 중심으로)

  • Dong, Kyung-Rae;Lee, Seun-Joo;Kweon, Dae-Cheol;Goo, Eun-Hoe;Jung, Jae-Eun;Lee, Kyu-Su
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.34-42
    • /
    • 2010
  • With the expanded use of radiation in modern medical practices, the most important issue in regards to efforts to reduce individual exposure dose is quality assurance. Therefore in order to study the present condition of quality assurance, the Gwangju Metropolitan City area was divided into five districts each containing ten hospitals. Four experiments were conducted: a reproducibility experiment for kVp, mA, and examination time (sec) intensity of illumination; half-value layer (HVL) measurement; and beam perpendicularity test matching experiment. The tube voltage reproducibility experiment for all fifty hospitals resulted in a 95.33% passing rate and mA and examination time both resulted in a 77.0% passing rate. The passing rate for intensity of illumination was 86.0% and 52.0% for HVL, which was the lowest passing rate of all four factors. For the beam perpendicularity test matching experiment, generally the central flux is matched to within $1.5^{\circ}$. Of all fifty hospitals 30.0% were beyond $3^{\circ}$. The results of the survey showed that 58% responded that they knew about quality assurance cycle. All fifty respondents stated that they have not received any training in regards to quality assurance at their current place of employment. Although quality assurance is making relative progress, the most urgent issue is awareness of the importance of quality assurance. Therefore, the implementation of professional training focusing on safety management and accurate quality assurance of radiation will reduce the exposure to radiation for radiologists and patients and higher quality imaging using less dosage will also be possible.

A Comparative Study of CTDI and the Effective Dose and the SNR according to the Area in the Abdominal CT (복부CT에서 면적에 따른 CTDI와 유효선량 및 SNR의 비교 연구)

  • Choi, Sung-Jun;Kang, Jun-Guk;Kim, Su-In;Kim, Youn-Ho;Lee, Do-Gyeong;Jung, Jin-Gyung;Cho, Ar-A;Jang, Jae-Hyeok;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.245-252
    • /
    • 2015
  • To obtain the best SNR (signal to noise ratio) due to changes in CTDI (computed tomography dose index) made for the purpose of setting the optimum image obtained by reducing the dose in abdominal CT. Abdominal CT scans of 59 patients a $400-499cm^2$ (n = 12), $500-599cm^2$ (n = 21), $600-699cm^2$ (n = 17), $700-799cm^2$ (n = 9) were separated by four groups and the effective dose was used in the Excel to get the area of the patient using the ImageJ program. Patients of CTDI, DLP, SNR, the effective dose were analyzed. Abdominal CT area was increased to 13 mGy in CTDI is 7.3 mGy, DLP to 732 in $394.4mGy{\cdot}cm$, also effective dose was 5.9 mSv increase in 11mSv. SNR is 15 dB was maintained at 12.7. CTDI according to the average of the abdominal area of 8.9 mGy, the average of the DLP was $481.54mGy{\cdot}cm$, the effective dose is calculated to be 7.2 mSV. Effective dose was calculated by multiplying the load factor of DLP in the abdomen showed no statistically significant difference of (p < .05), there was a significant difference in SNR (p > . 05). To improve image quality of abdominal CT scan image in consideration of the CTDI according to the volume of the patient it should be able to reduce the radiation exposure of the patients.

Gamma Irradiation Effects on Conchospores of Porphyra Species 2. The Effects of High Gamma Irradiation on Germination and Growth of Conchospores of Two Varieties (김의 각포자에 대한 r-선의 조사효과 2. 두 품종의 각포자의 발아생장에 미치는 고선량 r-선의 조사효과)

  • KIM Joong-Rae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.1
    • /
    • pp.52-56
    • /
    • 1985
  • For the fundamental studies of radiation breeding in edible marine algae, the biological effects on conchospores of Porphyra species by gamma-irradiation were examined. Two varieties, Keun-cham-gim (Porphyra tenera Kjell. form tamatsuensis Miura) and Saga No.5, were chosen for this study, and their conchospores after r-irradiation($5.0{\sim}20.0$ KR) were cultured for 50 days. The results obtained were summarized as follows. 1. Gamma-irradiation in less than the dose of 20KR did not affect germination of conchospores, and almost all spores grew into two cells germ in 24 hours after irradiation, but withering germs were gradually increased in number according to higher exposure within 5 days old culture. 2. High irradiation caused the induction of giant cells, abnormal useless growth of hold-fast, lumpish thalli and callus-like lumpy tissues. 3. The liberation of neutral spores from young germs and carpospores from mature thalli were observed on the frond exposed at $10{\sim}20$ KR irradiation. All spores were normal in division and its size. 4. The best irradiation effect on growth of Keun-cham-gim was observed at 10 KR dose, whose growth-rates were $140\%$ in wet weight and $108\%$ in mean frond area, but only $48\%$ was recorded in wet weight at 20 KR exposure. Saga No.5 were in contrast with Keun-cham-gim, and their most growth-rate was $400\%$ in wet weight ($258\%$ in frond area) at 10 KR irradiation and the worst was $20\%$ at the dose of 20 KR. 5. The withering phenomenon to death by treatment of gamma-ray presented substantial difference between two varieties. Survival rate compared with control in Keun-cham-gim was $70.7\%$ at 20 KR, but that in Saga No.5 recorded $47.0\%$ at same dose. 6. Synthesizing the results of high and low r-irradiation, it was suggested tat high r-irradiation in more than 5.0 KR inhibited conspicuously the growth of germs derived from conchospores, and about half of them withered at 15.0 KR dose or more.

  • PDF

UVB-Shielding Effects of para-Coumaric Acid (파라-쿠마린산의 자외선B 차단 효과)

  • Song, Kyo-Sun;Boo, Yong-Chool
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.38 no.3
    • /
    • pp.263-273
    • /
    • 2012
  • Recent studies have uncovered attractive properties of para-coumaric acid (PCA) as a potential skin hywhitening agent. The purpose of the current study was to examine its UVB-shielding effects. Effects of PCA on the viability of HaCaT cells exposed to UVB were assessed in vitro in comparison with other aromatic amino acid metabolites that have similar UV absorption spectra. For in vivo test, PCA cream (1.5 %) and cream base were topically applied to the dorsal skin of SKH-1 hairless mice and the inflammatory responses due to UVB exposure were monitored by changes in skin color (erythema) and thickness (edema). The cream application-UVB exposure regimen was repeated every other day for a total of 12 sessions. When HaCaT cells were irradiated with UVB, there was a dose-dependent decline in cell viability. The cell viability decline due to UVB exposure (10 mJ $cm^{-2}$) was significantly prevented by 100 ${\mu}M$ PCA, cinnamic acid, urocanic acid, or indole acrylic acid by 39, 27, 39, or 31 %, respectively. Topical application of PCA cream onto the dorsal skin of hairless mice (10 ${\mu}g\;cm^{-2}$) attenuated the changes of color parameters, $L^*$, $a^*$, $b^*$ values, and thickness of the UVB (150 mJ $cm^{-2}$)-exposed skin by 59, 50, 58, and 53 %, respectively. The current study, together with the previous studies that demonstrated the antimelanogenic effects of PCA, suggested that PCA may prevent not only dyspigmentation but also inflammatory reactions in the UVB-exposed skin.

DISTRIBUTION OF ABSORBED DOSES TO THE IMPORTANT ORGANS OF HEAD AND NECK REGION IN PANORAMIC RADIOGRAPHY (파노라마 촬영시 두경부 주요기관에 대한 흡수선량 분포)

  • Kim Byeong Sam;Choi Karp Shik;Kim Chin Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.2
    • /
    • pp.253-264
    • /
    • 1990
  • The purpose of this study was to estimate the distribution of absorbed doses of each important organs of head and neck region in panoramic radiography. Radiation dosimetry at internal anatomic sites and skin surfaces of phantom (RT-210 Humanoid Head & Neck Section/sup R/) was performed with lithium fluoride (TLD-100/sup R/) thermoluminescent dosimeters according to change of kilovoltage (65kVp, 75kVp and 85kVp) with 4 miliamperage and 20 second exposure time. The results obtained were as follows; Radiation absorbed doses of internal anatomic sites were presented the highest doses of 1.04 mGy, 1.065 mGy and 2.09 mGy in nasopharynx, relatively high doses of 0.525 mGy, 0.59 mGy and 1.108 mGy in deep lobe of parotid gland, 0.481 mGy, 0.68 mGy and 1.191 mGy in submandibular gland. But there were comparatively low doses of 0.172 mGy and 0.128 mGy in eyes and thyroid gland that absorbed dose was estimated at 85kVp. Radiation absorbed doses of skin surfaces were presented the highest doses of 1. 263 mGy, 1.538 mGy and 2.952 mGy in back side of first cervical vertebra and relatively high doses of 0.267 mGy, 0.401 mGy and 0.481 mGy in parotid gland. But there were comparatively low doses of 0.057 mGy, 0.068 mGy and 0.081 mGy in philtrum and 0.059 mGy in middle portion of chin that absorbed dose was estimated at 85kVp. According to increase of kilovoltage, the radiation absorbed doses were increased 1.1 times when kilovolt age changes from 65kVp to 75kVp and 1.9 times when kilovolt age changes from 75kVp to 85kVp at internal anatomic sites. According to increase of kilovoltage, the radiation absorbed doses were increased 1.3 times when kilovolt age changes from 65kVp to 75kVp and 1.6 times when kilovoltage changes from 75kVp to 85kVp at skin surfaces.

  • PDF

Evaluation of Image Noise and Radiation Dose Analysis In Brain CT Using ASIR(Adaptive Statistical Iterative Reconstruction) (ASIR를 이용한 두부 CT의 영상 잡음 평가 및 피폭선량 분석)

  • Jang, Hyon-Chol;Kim, Kyeong-Keun;Cho, Jae-Hwan;Seo, Jeong-Min;Lee, Haeng-Ki
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.357-363
    • /
    • 2012
  • The purpose of this study on head computed tomography scan corporate reorganization adaptive iteration algorithm using the statistical noise, and quality assessment, reduction of dose was evaluated. Head CT examinations do not apply ASIR group [A group], ASIR 50 applies a group [B group] were divided into examinations. B group of each 46.9 %, 48.2 %, 43.2 %, and 47.9 % the measured in the phantom research result of measurement of CT noise average were reduced more than A group in the central part (A) and peripheral unit (B, C, D). CT number was measured with the quantitive analytical method in the display-image quality evaluation and about noise was analyze. There was A group and difference which the image noise notes statistically between B. And A group was high so that the image noise could note than B group (31.87 HUs, 31.78 HUs, 26.6 HUs, 30.42 HU P<0.05). The score of the observer 1 of A group evaluated 73.17 on 74.2 at the result 80 half tone dot of evaluating by the qualitative evaluation method of the image by the bean curd clinical image evaluation table. And the score of the observer 1 of B group evaluated 71.77 on 72.47. There was no difference (P>0.05) noted statistically. And the inappropriate image was shown to the diagnosis. As to the exposure dose, by examination by applying ASIR 50 % there was no decline in quality of the image, 47.6 % could reduce the radiation dose. In conclusion, if ASIR is applied to the clinical part, it is considered with the dose written much more that examination is possible. And when examination, it is considered that it becomes the positive factor when the examiner determines.

A Study on measurement of scattery ray of Computed Tomography (전산화 단층촬영실의 산란선 측정에 대한 연구)

  • Cho, Pyong-Kon;Lee, Joon-Hyup;Kim, Yoon-Sik;Lee, Chang-Yeop
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.37-42
    • /
    • 2003
  • Purpose : Computed tomographic equipment is essential for diagnosis by means of radiation. With passage of time and development of science computed tomographic was developed time and again and in future examination by means of this equipment is expected to increase. In this connection these authors measured rate of scatter ray generation at front of lead glass for patients within control room of computed tomographic equipment room and outside of entrance door for exit and entrance of patients and attempted to ind out method for minimizing exposure to scatter ray. Material and Method : From November 2001 twenty five units of computed tomographic equipments which were already installed and operation by 13 general hospitals and university hospitals in Seoul were subjected to this study. As condition of photographing those recommended by manufacturer for measuring exposure to sauter ray was use. At the time objects used DALI CT Radiation Dose Test Phantom fot Head (${\oint}16\;cm$ Plexglas) and Phantom for Stomache(${\oint}32\;cm$ Plexglas) were used. For measurement of scatter ray Reader (Radiation Monitor Controller Model 2026) and G-M Survey were used to Survey Meter of Radical Corporation, model $20{\times}5-1800$, Electrometer/Ion Chamber, S/N 21740. Spots for measurement of scatter ray included front of lead glass for patients within control room of computed tomographic equipment room which is place where most of work by gradiographic personnel are carried out and is outside of entrance door for exit and entrance of patients and their guardians and at spot 100 cm off from isocenter at the time of scanning the object. The results : Work environment within computed tomography room which was installed and under operation by each hospital showed considerable difference depending on circumstances of pertinent hospitals and status of scatter ray was as follows. 1) From isocenter of computed tomographic equipment to lead glass for patients within control room average distance was 377 cm. At that time scatter ray showed diverse distribution from spot where no presence was detected to spot where about 100 mR/week was detected. But it met requirement of weekly tolerance $2.58{\times}10^{-5}\;C/kg$(100 mR/week). 2) From isocenter of computed tomographic equipment to outside of entrance door where patients and their guardians exit and enter was 439 cm in average, At that time scatter ray showed diverse distribution from spot where almost no presence was detected to spot with different level but in most of cases it satisfied requirement of weekly tolerance of $2.58{\times}10^{-6}\;C/kg$(100 mR/week). 3) At the time of scanning object amount of scatter ray at spot with 100 cm distance from isocenter showed considerable difference depending on equipments. Conclusion : Use of computed tomographic equipment as one for generation of radiation for diagnosis is increasing daily. Compared to other general X-ray photographing field of diagnosis is very high but there is a high possibility of exposure to radiation and scatter ray. To be free from scatter ray at computed tomographic equipment room even by slight degree it is essential to secure sufficient space and more effort should be exerted for development of variety of skills to enable maximum photographic image at minimum cost.

  • PDF

A Study of Image Quality and Exposed Dose by Field Size Changing on CBCT (CBCT 촬영 시 조사야 조절에 따른 영상의 최적화 및 피폭선량에 관한 고찰)

  • Bang, Seung Jae;Kim, Young Yeon;Jeong, Il Seon;Kim, Jeong Soo;Kim, Young Gon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.175-180
    • /
    • 2013
  • Purpose: Modern radiation therapy technique such as IGRT has become a routine clinical practice on LINAC for decrease patient's set-up error. CBCT can be used to adjust patient set-up error and treat patient more accurately. The Purpose of this study is to evaluate field size of CBCT for improving Image quality and suggest reference date of CBCT field size. Materials and Methods: Image date were acquired using KV CBCT and Catphan phantom (Half fan and full fan mode were scanned from 2 ~16 cm, at intervals of 2 cm). Field size were categorized by Small field size (2 cm, 4 cm), Medium field size (8 cm, 10 cm), Large field size (more than 14 cm) and evaluate. To estimated the CTDi using CTDi phantom and Ion chamber. Results: CT number linearity of Small and Large field size are greater than Medium field size. Spatial resolution are not significantly different without Small field size. But half fan mode is more different than full fan mode. In full fan, except Medium field size, all field size exceed recommendation for HU uniformity. But half pan has stability for all field except Small field size. CTDi makes radical sign function graph in Medium field size. Conclusion: The worst result was given by Small field size for Image quality and practically. Medium field size can be useful to prevent patient from radiation exposure and give better Image quality. So this study recommends that Medium field size (8~10 cm) is more suitable for CBCT.

  • PDF