• Title/Summary/Keyword: Radiation exchange

Search Result 174, Processing Time 0.026 seconds

A Study on the Inverse Analysis of Surface Radiation in a Cylindrical Enclosure (원통형상에서의 표면복사 역해석에 관한 연구)

  • KIm, Ki-Wan;Baek, Seung-Wook;Ryou, Hong-Sun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.6
    • /
    • pp.705-712
    • /
    • 2004
  • An inverse boundary analysis of surface radiation in an axisymmetric cylindrical enclosure has been conducted in this study. Net energy exchange method was used to calculate the radiative heat flux on each surface, and a hybrid genetic algorithm was adopted to minimize an objective function, which is expressed by sum of square errors between estimated and measured or desired heat fluxes on the design surface. We have examined the effects of the measurement error as well as the number of measurement points on the estimation accuracy. Furthermore, the effect of a variation in one boundary condition on the other boundary conditions was also investigated to get the same desired heat flux and temperature distribution on the design surface.

A Study on the Inverse Radiation Analysis in a Cylindrical Enclosure (원통형상에서의 역복사 해석에 관한 연구)

  • Kim, Ki-Wan;Baek, Seung-Wook;Ryou, Hong-Sun
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1516-1521
    • /
    • 2004
  • An inverse boundary analysis of surface radiation in an axisymmetric cylindrical enclosure has been conducted in this study. Net energy exchange method was used to calculate the radiative heat flux on each surface, and a hybrid genetic algorithm was adopted to minimize an objective function, which is expressed by sum of square errors between estimated and measured heat fluxes on the design surface. We have examined the effects of the measurement error as well as the number of measurement points on the estimation accuracy.

  • PDF

Analysis of Transient Heat Transfer Characteristics of Dish-Type Solar Receiver System (접시형 태양열 흡수기의 Transient 열전달 특성에 대한 수치해석 연구)

  • Lee, Ju-Han;Seo, Joo-Hyun;Oh, Sang-June;Lee, Jin-Kyu;Seo, Tae-Beom
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2094-2099
    • /
    • 2008
  • A numerical and experimental studies are carried out to investigate the transient heat transfer characteristics of 5kWth dish-type solar air receiver. Measured solar radiation and temperatures at several different locations are used as boundary conditions for numerical simulation. Many parameters' effects (reflectivity of the reflector, the thermal conductivity of the receiver body, transmissivity of the quartz window, etc.) on the thermal performance are investigated. Discrete Transfer Method is used to calculate the radiation heat exchange in the receiver. A transient heat transfer model is developed and the rate of radiation, convection and conduction heat transfer are calculated. Comparing the experimental and numerical results, good agreement is obtained. Using the numerical model, the transient heat transfer characteristics of volumetric air receiver for dish-type solar thermal systems are known and the transient thermal performance of the receiver can be estimated.

  • PDF

Combined Radiation and Natural Convection Heat Transfer in an Enclosure with a Constant Heat Flux at the Bottom (밑면에 균일 열유속이 존재하는 밀폐공간에서의 복사 - 자연대류열전달)

  • Kwon, Sun-Sok;Kwon, Yong-Il
    • Solar Energy
    • /
    • v.12 no.2
    • /
    • pp.28-42
    • /
    • 1992
  • This investigation is carried out numerically for the two dimensional natural convection and surface radiation heat transfer in a square enclosure. The bottom wall is a constant heat flux at hot temperature and also top wall is isothermal at cold temperature whereas the left and right side walls are adiabatic except a transparent window on the right side partially. The exchange of radiant energy is obtained by the net radiation method and the shape factor by the crossed string method. The change in temperature and Nusselt number distributions of the walls due to the effect of the wall emissivity for various emissivities and for various dimensionless insolation energies are investigated. The dimensionless local convective heat flux and local radiative heat flux distributions in the wall except an adiabatic wall are also compared.

  • PDF

Performance Enhancement of Solar Thermal Storage Tank with Heat Exchange Coils (Part 1 : Verification Experiment) (열교환코일 내장형 태양열 축열조의 성능향상 (제1보 실증실험))

  • Lee, Uk-Jae;Hong, Hiki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.4
    • /
    • pp.213-219
    • /
    • 2015
  • A thermal storage tank with internal heat exchange coils is commonly used in solar thermal systems with a collector area below $100m^2$. The coils are installed in the lower part of the tank because the temperature of the upper part of the tank can drop if the outlet temperature of the collector becomes lower than the upper temperature of the tank, which is a kind of temperature reversal. As an alternative to the well-mixed storage tank with lower coil only, we have proposed a tank with lower and upper coils and have achieved superior thermal stratification in the tank, which results in increased collector efficiency and solar fraction. But, the phenomenon of temperature reversal was often observed in the tank when the load or solar radiation changed rapidly. In the present work, revised control was successfully applied, i.e., to heat only the lower coil using a three way valve if temperature reversal occurs and to operate the collector at a low flow rate when the quality of solar radiation is not good.

Fabrication of Silane-crosslinked Proton Exchange Membranes by Radiation and Evaluation of Fuel Cell Performance (방사선을 이용한 실란 가교구조의 유/무기 복합 수소이온 교환막 제조 및 연료전지 성능 평가)

  • Lee, Ji-Hong;Sohn, Joon-Yong;Shin, Dong-Won;Song, Ju-Myung;Lee, Young-Moo;Nho, Young-Chang;Shin, Jun-Hwa
    • Polymer(Korea)
    • /
    • v.36 no.4
    • /
    • pp.525-530
    • /
    • 2012
  • In this study, silane-crosslinked organic/inorganic composite membranes were prepared by simultaneous irradiation grafting of binary monomer mixtures (styrene and 3-(trimethoxysilyl)propyl methacrylate (TMSPM)) with various compositions onto a poly(ethylene-alt-tetraethylene) (ETFE) film and followed by sol-gel processing and sulfonation to provide a silane-crosslinked structure and a proton conducting ability, respectively. The Fourier transform infrared spectroscopy (FTIR) and thermo gravimetric analysis (TGA) were utilized to confirm the crosslinking of ETFE-g-PS/PTMSPM films. The prepared membranes with similar ion exchange capacity but a different TMSPM content were selected and their membrane properties were compared. The ETFE-g-PSSA/PTMSPM membranes were characterized by water uptake, dimensional stability, and proton conductivity after sulfonation. The membrane electrode assemblies (MEA) of the prepared membranes were fabricated and their single cell performances were measured.

Changes in Exposure Dose and Image Quality due to Radiation Shielding in Pediatric Patients (소아 환자에서 방사선 차폐체로 인한 피폭선량과 화질의 변화)

  • Lee, Young-Hee;Lee, Yong-Ki
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.931-936
    • /
    • 2020
  • This study was conducted to observe the changes in radiation exposure dose and image quality of pediatric patients according to the presence and size of the gonadal shield when using the AEC system. X-ray equipment was used to measure the radiation exposure dose in the abdominal and gonads of the pediatric phantom when no shielding body was used and when three different sizes of shielding body were used, and SNR and CNR were measured through the obtained images. As a result of the study, the radiation exposure dose to the gonads decreased in proportion to the size of the radiation shield, but the radiation exposure dose to the abdomen was rather increased, and the image quality did not change. It is recommended to use a shield with a size optimized for the age, weight, and body size of the pediatric patient so as not to be overexposed by the increased radiation due to the radiation shield due to the use of the AEC System. For this purpose, information about the pediatric patient with the nurse It is believed that exchange is necessary.

Ion Exchange Behavior of $^{137}Cs,\;^{60}Co$ on Diphosil, a new ion exchange resin (Diphosil 이온교환수지에 의한 $^{137}Cs,\;^{60}Co$의 이온교환 거동)

  • Kim, Su-Jeong;Lee, Sang-Jin;Yang, Ho-Yeon;Shin, Sang-Woon
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • Diphosil, a new version of the organic-inorganic composite resin developed by ANL has a structure of the chelating diphosphonic acid groups grafted to a silica support. To apply Diphosil for the treatment of liquid radioactive waste from nuclear power plants, the adsorption equilibrium and column experiments were carried out for the main radionuclides, $^{137}Cs\;and\;^{60}Co$, in the liquid radwaste stream. Through the adsorption equilibrium experiments, the removal efficiencies of $^{137}Cs\;and\;^{60}Co$, and the effects of non-radioactive ions on the removal efficiency have been measured in various conditions using radiotracers. The breakthrough curves for the tested tracers were obtained from the laboratory scale column tests using the simulated liquid radioactive waste. In addition, the removal capacity of Diphosil is compared with that of Amberlite IRN 77 resin, generally used in nuclear power plants.

Mean Heat Flux at Gunsan Harbor (군산항의 평균 열속)

  • CHOI Yong-Kyu;JO Young-Jo;CHOI Ok-In;YANG Won-Seok
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.5
    • /
    • pp.535-540
    • /
    • 2003
  • Based on the monthly weather report of Korea Meteorological Administration (KMA) and daily sea surface temperature (SST) data from National Fisheries Research and Development Institute (NFRDl) (1991-2001), mean heat fluxes were estimated at the Gunsan harbor Net heat flux was transported from the air to the sea surface during March to early September, and it amounts to $125\;Wm^{-2}$ in average daily during May to June. During the middle of September to February, the transfer of net heat flux was conversed from the sea surface to the air with $-125\;Wm^{-2}$ in mininum value in October. Short wave radiation was ranged from 50 to $248\;Wm^{-2}$ showing maxima in April to June. Long wave radiation was ranged from 25 to $92\;Wm^{-2}$ with mininum value in June to July. Sensible heat flux denoting negative values in April to August was ranged from -30 to $72\;Wm^{-2}.$ Latent heat flux was ranged from 15 to $82\;Wm^{-2}$ with maxima in August to September. The phase of heat exchange was changed from cooling to heating in the end of February, and from heating to cooling In the beginning of September. The advective term of heat flux showed minima in April to June and maxima in November. The ratio of temperature variations was 1.37 in the sea surface process and the horizontal process by advection. This indicates that the main factor in variation of temperature at Gunsan harbor is the heat exchange process through the sea surface from the air.

Capture of Metal Ions by Cross-linked Sulfonic Acid Type Ion Exchange Membranes (가교제를 도입시킨 술폰산형 이온교환막의 금속이온 포집)

  • Kim, Min;Kim, Ye-Jin;Park, Sang-Jin
    • Membrane Journal
    • /
    • v.19 no.4
    • /
    • pp.333-340
    • /
    • 2009
  • This paper is designed with the purpose of improving the efficiency of the sulfonic acid ion exchange membranes by radiation induced graft polymerization. It has been shown that the porous hollow fiber membranes could cause permeability blocking between pores and ion exchanged graft chains. Addition of crosslinker such as N-ethylene glycol dimethacrylate will permit to increase the permeation flux. In this research, the ethylene glycol dimethacrylate (EDMA) and diethylene glycol dimethacrylate (DDMA) with different length are used as crosslinkers. The ion exchanged cross-linked membrane (EDMA, DDMA) containing sulfonic acid group by radiation induced grafted polymerization are sn died for adsorb metal ions (Pb). It has been shown that adsorbed metal ions ($Pb^{2+}$) for the EDMA and DDMA membranes with the density of sulfonic acid groups, 1.40 mmol/g and 2.14 mmol/g, respectively are 13.82 mg/g, 17.37 mg/g, accordingly.