• Title/Summary/Keyword: Radiation efficiency

Search Result 1,231, Processing Time 0.028 seconds

Effect of Persulfate on Disinfection of Escherichia coli K12 by Gamma Radiation (감마선을 이용한 Escherichia coli K12의 살균에서 persulfate의 효과)

  • Lee, O Mi;Kim, Tae Hun;Yu, Seungho;Jung, Inha;Lee, Myun Joo
    • Journal of Radiation Industry
    • /
    • v.5 no.1
    • /
    • pp.63-67
    • /
    • 2011
  • A comparative experiment was conducted to compare the effects of persulfate with gamma radiation on the disinfection efficiencies against Escherichia coli K12. The microorganism used for the disinfection experiments were prepared by transferring a bacterial stock culture into a 50 ml nutrient broth an incubating for 24 hrs at $37^{\circ}C$. The initial concentration of the harvested culture was approximately $10^7$ to $10^9CFU\;ml^{-1}$. The culture solution was irradiated at different absorbed doses of 0.1, 0.2, 0.3, 0.4, 0.5, 0.7, and 1 kGy, respectively. The disinfection efficiency of persulfate with gamma radiation of 0.3 kGy against Escherichia coli K12 was 97.2% and while the gamma radiation only was 90.01% at 0.3 kGy. Therefore, it could be thought that addition of persulfate in the disinfection of Escherichia coli K12 can enhance the disinfection efficiency when it is used together with gamma radiation.

Expansion of Dusty H II Regions and Its Impact on Disruption of Molecular Clouds

  • Kim, Jeong-Gyu;Kim, Woong-Tae;Ostriker, Eve
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.58.3-59
    • /
    • 2015
  • Dynamical expansion of H II regions plays a key role in dispersing surrounding gas and therefore in limiting the efficiency of star formation in molecular clouds. We use analytic methods and numerical simulations to explore expansions of spherical dusty H II regions, taking into account the effects of direct radiation pressure, gas pressure, and total gravity of the gas and stars. Simulations show that the structure of the ionized zone closely follows Draine (2011)'s static equilibrium model in which radiation pressure acting on gas and dust grains balances the gas pressure gradient. Strong radiation pressure creates a central cavity and a compressed shell at the ionized boundary. We analytically solve for the temporal evolution of a thin shell, finding a good agreement with the numerical experiments. We estimate the minimum star formation efficiency required for a cloud of given mass and size to be destroyed by an HII region expansion. We find that typical giant molecular clouds in the Milky Way can be destroyed by the gas-pressure driven expansion of an H II region, requiring an efficiency of less than a few percent. On the other hand, more dense cluster-forming clouds in starburst environments can be destroyed by the radiation pressure driven expansion, with an efficiency of more than ~30 percent that increases with the mean surface density, independent of the total (gas+stars) mass. The time scale of the expansion is always smaller than the dynamical time scale of the cloud, suggesting that H II regions are likely to be a dominant feedback process in protoclusters before supernova explosions occurs.

  • PDF

Radiation Efficiency Improvement of RFID Tag Antenna for Metallic Objects Printed on Lossy Substrate (손실 기판을 이용한 금속 부착형 RFID 태그 안테나의 복사 효율 향상)

  • Son, Hae-Won;Choi, Won-Kyu;Choi, Gil-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.11
    • /
    • pp.1265-1271
    • /
    • 2008
  • In this paper, we propose a new antenna design method for RFID tass on metallic surfaces using a low-cost, high-loss substrate such as FR4. The proposed design method highly reduces the substrate loss due to its dielectric loss, and so improves the radiation efficiency of the tag antenna more than double compared with a conventional PIFA(planar inverted-F antenna). The equivalent circuit model of the antenna according to the proposed method was established and its characteristics were analyzed systematically in this paper. The excellency of the proposed design method was verified by the fabrication and measurement of a prototype antenna.

A Study on the Approximate Formula for Radiation Efficiency of a Simply Supported Rectangular Plate in Water (단순지지 사각 접수 평판의 방사효율 근사식에 관한 연구)

  • Kim, Hyun-Sil;Kim, Jae-Seung;Kim, Bong-Ki;Kim, Sang-Ryul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.1
    • /
    • pp.21-27
    • /
    • 2014
  • In this paper, an approximate formula for radiation efficiency of the plate surround by an infinite rigid baffle is studied. The plate is simply supported and one side is in contact with air, while other side with water. By assuming an infinite plate, the fluid loading effect is derived in terms of an effective mass. Based on the observation that the fluid loading effect decreases as frequency increases, the radiation efficiency formula at high frequency, which was originally derived for a plate vibrating in the air, is modified as the approximate formula for a submerged plate. The fluid loading effect is taken into account in the wavenumber of the plate. Comparisons of the approximate formula with the numerical results shows that they match well except the mid-frequency range in which numerical results show many oscillations. In numerically solving the fully coupled equations of motion, fourfold integrals of the impedance coefficients are reduced to single nonsingular integrals, which results in substantial reduction in computing time.

Decomposition of Acetylsalicylic Acid by Gamma Ray (감마선 조사에 의한 Acetylsalicylic Acid의 분해)

  • Ahn, Young Deok;Lee, Kyoung-hwon;Lee, O Mi;Kim, Tae-Hun;Jung, In ha;Yu, SeungHo;Lee, Myun-Joo
    • Journal of Radiation Industry
    • /
    • v.5 no.3
    • /
    • pp.253-258
    • /
    • 2011
  • Acetylsalicylic acid (ASA) has been issued recently in contaminated water environments because of potential impacts on ecosystem and public health. This study was aimed at investigating the possibility of ASA degradation using gamma ray irradiation. In addition, the use of sodium persulfate, hydrogen peroxide, ferrous sulfate were tested in order to examine a synergistic effect with gamma ray. The absorbed dose was ranged from 0.2 to 10 kGy and the concentration of oxidants were from 0.1 to 10 mM in this study. The concentration of ASA was gradually decreased corresponding to the increase of the absorbed dose. When soudium persulfate was simultaneously applied, most of the parent compound was completely degraded even at a low dose of 0.8 kGy. The removal efficiency of total organic carbon was 90% even at the highest dose of 10 kGy without sodium persulfate. However, the efficiency was dramatically enhanced up to 98% at the same dose by adding 10 mM of oxidants. It was suggested that hydroxyl radical ($OH{\cdot}$) and sulfate radical ($SO{_4}^-{\cdot}$) were formed in the system and made roles in degrading ASA at the same time.

Construction and Testing of a radiation-beam powered TA (ThermoAcoustic) washer for grease removal

  • Chen, Kuan;DaCosta, David H.;Kim, Yeongmin;Oh, Seung Jin;Chun, Wongee
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.1
    • /
    • pp.21-28
    • /
    • 2015
  • A small washer powered directly and solely by thermal radiation was constructed and tested to explore the feasibility of using solar energy or other types of thermal radiation for washing and cleaning. In principle, TA (ThermoAcoustic) washers have the benefits of simpler design and operation and fewer energy conversion processes, thus should be more energy efficient and cost less than electric washing/cleaning systems. The prototype TA converter we constructed could sustain itself with consistent fluid oscillations for more than 20 minutes when powered by either concentrated solar radiation or an IR (infrared) heater. The frequencies of water oscillations in the wash chamber ranged from 2.6 to 3.6 Hz. The overall conversion efficiency was lower than the typical efficiencies of TA engines. Change in water temperature had little effect on the oscillatory flow in the TA washer due to its low efficiency. On the other hand higher water temperatures enhanced grease removal considerably in our tests. Methods for measuring the overall conversion efficiency, frictional loss, and grease removal of the TA washing system we designed were developed and discussed.

Optimization of CORVUS Planning System with PRIMART Linac for Intensity Modulated Radiation Therapy

  • Lee, Se-Byeong;Jino Bak;Cho, Kwang-Hwan;Chu, Sung-sil;Lee, Suk;Suh, Chang-ok
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.83-85
    • /
    • 2002
  • Yonsei Cancer Center introduced an IMRT System at the beginning of February, 2002. The system consists of CORVUS(NOMOS) inverse planning machine, LANTIS(SIEMENS), PRIMEVIEW and PRIMART Linac(SIEMENS). The optimization of CORVUS planning system with PRIMART is an important work to get an efficient treatment plan. So, we studied two Finite Size Pencil Beams, 1.0 x 1.0 cm$^2$ and 0.5 x 1.0 cm$^2$, and four leaf transmission sets, 5%, 10%, 20%, 33%. We compared the dose distribution of target volume and delivery efficiency of the plan results.

  • PDF

PRESENT AND FUTURE OF SUPER HIGH-EFFICIENCY TANDEM SOLAR CELLS

  • Yamaguchi, Masafumi
    • Electrical & Electronic Materials
    • /
    • v.11 no.11
    • /
    • pp.37-45
    • /
    • 1998
  • In this paper, present status of super high-efficiency tandem solar cells has been reviewed and key issues for realizing super high-efficiency have also been discussed. In addition, the terretrial R&D activities of tandem cells, in the New Sunshine Program of MITI(Ministry of International Trade and Industry) and NEDO(New Energy and Industrial Technology Development Organization) in Japan are reviewed briefly. The mechanical stacked 3-junction cells of monolithically grown InGaP/GaAs 2-junction cells and InGaAs cells have reached the highest efficiency achieved in Japan of 33.3% at 1-sun AM1.5. This paper also reports high-efficiency InGaP/GaAs 2-junction solar cells with a world-record efficiency of 26.9% at AM0, 28$^{\circ}C$ and radiation damage recovery phenomena of the tandem cell performance due to minority-carrier injection under light illumination or forward bias, which causes defect annealing in InGaP top cells. Future prospects for realizing super-high efficiency and low-cost tandem solar cells are also described.

  • PDF

Research of Efficiency for Gas Electron Multiplier Detector to Monitor Low Energy Gamma-Ray and Beta-Ray (낮은 에너지 감마선과 베타선 모니터링을 위한 Gas Electron Multiplier 검출기의 효율성에 대한 연구)

  • Lee, Soonhyouk;Jung, Jae Hoon;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.95-99
    • /
    • 2014
  • Radiation monitoring is one of the most important process in all places where radioactive material is used including hospital. In this preliminary study, we made GAS electron multiplier (GEM) detector and acquired relative efficiencies in order to see if GEM detector can be useful in radiation monitoring system. The relative efficiency was acquired by using the ratio of GEM detector efficiency to CdTe detector efficiency. The relative efficiency of 72% and 4% was acquired for beta-ray and gamma-ray respectively.

Virtual calibration of whole-body counters to consider the size dependency of counting efficiency using Monte Carlo simulations

  • Park, MinSeok;Kim, Han Sung;Yoo, Jaeryong;Kim, Chan Hyeong;Jang, Won Il;Park, Sunhoo
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.4122-4129
    • /
    • 2021
  • The counting efficiencies obtained using anthropomorphic physical phantoms are generally used in whole-body counting measurements to determine the level of internal contamination in the body. Geometrical discrepancies between phantoms and measured individuals affect the counting efficiency, and thus, considering individual physical characteristics is crucial to improve the accuracy of activity estimates. In the present study, the counting efficiencies of whole-body counting measurements were calculated considering individual physical characteristics by employing Monte Carlo simulation for calibration. The NaI(Tl)-based stand-up and HPGe-based bed type commercial whole-body counters were used for calculating the counting efficiencies. The counting efficiencies were obtained from 19 computational phantoms representing various shapes and sizes of the measured individuals. The discrepancies in the counting efficiencies obtained using the computational and physical phantoms range from 2% to 33%, and the results indicate that the counting efficiency depends on the size of the measured individual. Taking into account the body size, the equations for estimating the counting efficiencies were derived from the relationship between the counting efficiencies and the body-build index of the subject. These equations can aid in minimizing the size dependency of the counting efficiency and provide more accurate measurements of internal contamination in whole-body counting measurements.