• Title/Summary/Keyword: Radiation efficiency

Search Result 1,248, Processing Time 0.029 seconds

Characterization of a CLYC Detector and Validation of the Monte Carlo Simulation by Measurement Experiments

  • Kim, Hyun Suk;Smith, Martin B.;Koslowsky, Martin R.;Kwak, Sung-Woo;Ye, Sung-Joon;Kim, Geehyun
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.1
    • /
    • pp.48-55
    • /
    • 2017
  • Background: Simultaneous detection of neutrons and gamma rays have become much more practicable, by taking advantage of good gamma-ray discrimination properties using pulse shape discrimination (PSD) technique. Recently, we introduced a commercial CLYC system in Korea, and performed an initial characterization and simulation studies for the CLYC detector system to provide references for the future implementation of the dual-mode scintillator system in various studies and applications. Materials and Methods: We evaluated a CLYC detector with 95% $^6Li$ enrichment using various gamma-ray sources and a $^{252}Cf$ neutron source, with validation of our Monte Carlo simulation results via measurement experiments. Absolute full-energy peak efficiency values were calculated for gamma-ray sources and neutron source using MCNP6 and compared with measurement experiments of the calibration sources. In addition, behavioral characteristics of neutrons were validated by comparing simulations and experiments on neutron moderation with various polyethylene (PE) moderator thicknesses. Results and Discussion: Both results showed good agreements in overall characteristics of the gamma and neutron detection efficiencies, with consistent ~20% discrepancy. Furthermore, moderation of neutrons emitted from $^{252}Cf$ showed similarities between the simulation and the experiment, in terms of their relative ratios depending on the thickness of the PE moderator. Conclusion: A CLYC detector system was characterized for its energy resolution and detection efficiency, and Monte Carlo simulations on the detector system was validated experimentally. Validation of the simulation results in overall trend of the CLYC detector behavior will provide the fundamental basis and validity of follow-up Monte Carlo simulation studies for the development of our dual-particle imager using a rotational modulation collimator.

Analysis of Heat Loss with Mirror Array and Receiver Shapes on the Dish Solar Collector (반사경 배치 및 흡수기 형상에 따른 접시형 태양열 집열기의 열손실 해석)

  • Seo, Joo-Hyun;Ma, Dae-Sung;Kim, Yong;Kang, Yong-Heack;Seo, Tae-Beom
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.1
    • /
    • pp.35-41
    • /
    • 2008
  • The radiative heat loss from a receiver of a dish solar collector is numerically investigated. The dish solar collector considered in this paper consists of a receiver and multi-faceted mirrors. In order to investigate the performance comparison of dish solar collectors, six different mirror arrays and four different receivers are considered. A parabolic- shaped perfect mirror of which diameter is 1.40 m is considered as the reference for the mirror arrays. The other mirror arrays which consist of twelve identical parabolic-shaped mirror facets of which diameter are 0.405 m are suggested for comparison. Their reflecting areas, which are 1.545 $m^{2}$, are the same. Four different receiver shapes are a conical, a dome, a cylindrical, and a unicorn type. The radiative properties of the mirror surfaces and the receiver surfaces may vary the thermal performance of the dish solar collector so that various surface properties are considered. In order to calculate the radiative heat loss in the receiver, two kinds of methods are used. The Net Radiation Method that is based on the radiation heat balance on the surface is used to calculate the radiation heat transfer rate from the inside surface of the receiver to the environment. The Monte-Carlo Method that is the statistical approach is adopted to predict the radiation heat transfer rate from the reflector to the receiver. The collector efficiency is defined as the results of the optical efficiency and the receiver efficiency. Based on the calculation, the unicorn type has the best performance in receiver shapes and the STAR has the best performance in mirror arrays except the perfect mirror.

In vitro and in vivo Biological Responses of Proton Irradiation from MC-50 Cyclotron

  • Jung, Uhee;Eom, Hyeon Soo;Jeong, Kwon;Park, Hae-Ran;Jo, Sung-Kee
    • Journal of Radiation Industry
    • /
    • v.6 no.3
    • /
    • pp.223-229
    • /
    • 2012
  • In this study, we investigated the biological damage and stress responses induced by ion beam (proton beam) irradiation as a basis for the development of protective measures against space radiation. We examined the biological effects of proton beam produced by MC-50 cyclotron at KIRAMS on the cultured cells and mice. The proton beam energy used in this study was 34.9 MeV and the absorption dose rate for cells and mice were $0.509Gy\;sec^{-1}$ and $0.65Gy\;sec^{-1}$, respectively. The cell survival rates measured by plating efficiency showed the different sensitivity and dose-relationship between CHO cells and Balb/3T3 cells. HGPRT gene mutation frequency in Balb/3T3 was $15{\times}10^{-6}Gy^{-1}$, which was similar to the reported value of X-ray. When stress signaling proteins were examined in Balb/3T3 cells, $I{\kappa}B-{\alpha}$ decreased markedly whereas p53, phospho-p53, and Rb increased after proton beam irradiation, which implied that the stress signaling pathways were activated by proton beam irradiation. In addition, cellular senescence was induced in IMR-90 cells. In the experiments with C57BL/6 mouse, the immune cells (white blood cells, lymphocytes) in the peripheral blood were greatly reduced following proton beam irradiation whereas red blood cells and platelets showed relatively little change. These results can be utilized as basic data for studying the biological effects of proton beam using MC-50 cyclotron with respect to proton therapy research as well as space radiation research.

Antibiotic Resistance of Escherichia Coli and Brevibacterium sp. Isolated from Livestock Waste and Disinfection Efficiency of Gamma-Ray Irradiation (축산폐기물에서 분리된 항생제 내성균 Escherichia coli....Brevibacterium sp.의 내성 특성 및 감마선 살균 효능)

  • Jang, Eun-Hee;Jung, Sang-Hyuk;Nam, Youn-Ku;Park, Woo-Shin;Lee, Myun-Joo;Kim, Tak-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.7
    • /
    • pp.676-681
    • /
    • 2010
  • Antibiotic resistant bacteria were isolated from livestock wastes and the resistance patterns were investigated using various antibiotic agents. Also, a gamma ray was tested regarding the aspects of the effect on resistance pattern and the efficiency of disinfection. Among the isolates, Esherichia coli and Brevibacterium sp. showed the most serious resistance patterns. Esherichia coli had resistance against 9 agents whereas Brevibacterium sp. against 7 agents. It can be suggested from these results that the abuse of antibiotic agents will cause a serious mutation problem even to Esherichia coli which is ubiquitous in the ecosystem. Esherichia coli could be easily controlled but Brevibacterium sp. had a moderate resistance to the gamma ray under low doses. In the case of Brevibacterium sp, more than 2.0 kGy of a radiation dose will be required in order to achieve an enhanced efficiency of disinfection.

Adsorption of Heavy Metal Ions onto Chemically Oxidized Ceiba pentandra (L.) Gaertn. (Kapok) Fibers

  • Chung, Byung-Yeoup;Cho, Jae-Young;Lee, Min-Hee;Wi, Seung-Gon;Kim, Jin-Hong;Kim, Jae-Sung;Kang, Phil-Hyun;Nho, Young-Chang
    • Journal of Applied Biological Chemistry
    • /
    • v.51 no.1
    • /
    • pp.28-35
    • /
    • 2008
  • The physico-chemical properties of kapok fibers were altered via the combination processes of chlorite-periodate oxidation, in order to assess their efficacy as a heavy metal adsorbent. The chemically-oxidized kapok fibers were found to harbor a certain amount of polysaccharides, together with lowered lignin content. This alteration in lignin characteristics was clearly confirmed via FTIR and NBO yield. Moreover, chemically oxidized kapok fibers retained their hollow tube shape, although some changes were noted. The chemically oxidized kapok fibers evidenced elevated ability to adsorb heavy metal ions with the best fit for the Langmuir adsorption isotherm model. Three cycles of adsorption-desorption were conducted with in-between regeneration steps. Our experimental results indicated that chemically oxidized kapok fibers possessed excellent adsorption characteristics, and the modified kapok fibers could be completely regenerated with almost equimolar diluted sodium hydroxide. Pb, Cu, Cd and Zn ions evidenced adsorption rates of 93.55%, 91.83%, 89.75%, and 92.85% on the chemically oxidized kapok fibers. The regeneration efficiency showed 73.58% of Pb, 71.55% of Cu, 66.87% of Cd, and 75.00% of Zn for 3rd cycle with 0.0125N NaOH.

Changes according to the geometry of the shield using MCNP code system (MCNP코드 시스템을 이용한 차폐물 geometry에 따른 결과 변화에 대한 연구)

  • Kang, Ki-byung;Lee, Nam-ho;Hwang, Young-kwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.1031-1033
    • /
    • 2013
  • Radiation protection, as well as finding the location of the radiation source, such as the Fukushima radiation leak accident, it is important for the early and safe disposal of nuclear accident. The three-dimensional position of the radiation source detection distance of the radiation source can provide additional information to the existing radiation detectors radiation of a two-dimensional position detection function and then it can play a decisive role in the radiation contaminant removal and decontamination work. In this research, three-dimensional semiconductor sensor based on dual radiation detectors radiation source device visible part of the research and development of efficient radiation sensor unit on the design of the shielding structure.The lightweight, high-efficiency radiation source locator implementation was attempted for the structure and thickness of the shielding and collimator to perform the simulation of the radiation shielding for the various parameters of the shape model through design the optimal structure of the MCNP-based heavy-duty tungsten shielding, lead shielding The results of this study, is a compact, lightweight three-dimensional radiation source detection and future of silicon - based sensors will be used in the study.

  • PDF

The regulatory system for imported-cargo radiation monitoring in Korea and a proposal for its improvement

  • Wo Suk Choi ;Tae Young Kong ;Hee Geun Kim;Eun Ji Lee ;Seong Jun Kim ;Jin Ho Son ;Chang Ju Song;Hwa Pyoung Kim;Cheol Ki Jeong
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.1-11
    • /
    • 2023
  • To protect people and the environment from environmental radiation, the Act on Protective Action Guidelines against Radiation in the Natural Environment was formulated in Korea in 2011. This law regulates matters related to radiation safety that can be encountered in life. In accordance with this law, radiation monitoring equipment is operated at major airports and ports across the country, ensuring radiation monitoring of imported cargo. Currently, six ministries conduct radiation monitoring of imported cargo: the Nuclear Safety and Security Commission; the Korea Customs Service; the Ministry of Food and Drug Safety; the Ministry of Environment; the Ministry of Agriculture, Food and Rural Affairs; and the Korea Forest Service. Each ministry designates the relevant cargo items for radiation monitoring. The objective of this study was to comprehensively review the Korean radiation monitoring system for imported cargo and identify the areas and scopes of improvement. This paper also proposes a new law and an integrated supervision plan, which involves establishing a dedicated department to enhance the efficiency and professionalism of the national radiation monitoring system for imported cargo. The review will contribute to the development of a more sophisticated national radiation monitoring system for imported cargo.

High-Efficiency, High-Gain, Broadband Quasi-Yagi Antenna and Its Array for 60-GHz Wireless Communications

  • Ta, Son Xuat;Kang, Sang-Gu;Han, Jea Jin;Park, Ikmo
    • Journal of electromagnetic engineering and science
    • /
    • v.13 no.3
    • /
    • pp.178-185
    • /
    • 2013
  • This paper introduces a high-efficiency, high-gain, broadband quasi-Yagi antenna, and its four-element array for use in 60-GHz wireless communications. The antenna was fed by a microstrip-to-slotline transition consisting of a curved microstripline and a circular slot to allow broadband characteristics. A corrugated ground plane was employed as a reflector to improve the gains in the low-frequency region of the operation bandwidth, and consequently, to reduce variation. The single antenna yielded an impedance bandwidth of 49 to 69 GHz for $|S_{11}|$ <-10dB and a gain of >12.0 dBi while the array exhibited a bandwidth of 52 to 68 GHz and a gain greater than 15.0 dBi. Both proposed designs had small gain variations (${\pm}0.5$ dBi) and high radiation efficiency (>95%) in the 60-GHz bands. The features of the proposed antenna were validated by designing, fabricating, and testing a scaled-up configuration of the single antenna at the 15-GHz band. The measurements resulted in an impedance bandwidth of 13.0 to 17.5 GHz for $|S_{11}|$ <-10dB, a gain of 10.1 to 13.2 dBi, and radiation efficiency in excess of 88% within this bandwidth. Additionally, the 15-GHz antenna yielded quite symmetric radiation profiles in both E- and H-planes, with a high front-to-back ratio.

Design of a High Efficiency Neutron Detector Using a GEM (GEM을 이용한 고효율 중성자 검출기 설계)

  • Kim, Yong-Kyun;Park, Se-Hwan;Kang, Sang-Mook;Chung, Chong-Eun
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.1
    • /
    • pp.35-37
    • /
    • 2005
  • The radiation detector research group at KAERI has developed a high efficiency neutron detector using a Gas Electron Multiplier (GEM). The double GEM was fabricated and operated in an Ar/Isobutane mixture. For an application to a high efficiency neutron detector, $^6Li\;or\;^{10}B$ neutron converters coated on each surface of the multi GEM foils were considered. The optimized thickness of the thin film for a neutron detection was calculated with the MCNP and SRIM. The neutron efficiency was calculated by changing the chemical components of the thin film, and the thickness of the thin film. The thermalized neutrons were measured by a GEM detector with a thin neutron converter on the drift plate.

Development of Electronic Portal Imaging Device and Treatment Position Verification for Fractionated Stereotatic Radiotherapy

  • Lee, Dong-Hoon;Ji, Young-Hoon;Lee, Dong-Han;Kim, Yoon-Jong;Chilgoo Byun;Hong, Seung-Hong;Rhee, Soo-Yong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.446-449
    • /
    • 2002
  • The video based electronic portal imaging device (EPID), which could display the portal image in near real time, was implemented to verify treatment position error in FSRT(Fractionated Stereotatic Radiation Therapy) instead of a portal film. Also, Developed FSRT system was composed of the stereotactic frame, frame mounting system and collimator cones. The verification of treatment position is very crucial in special therapies like FSRT. In general, the FSRT uses high dpse rate at small field size for treating small intracranial lesions. To evaluate quantitative positioning errors in FSRT, we used the first FSRT image as reference image and obtained the second FSRT image that was moved 2mm intentionally and detected intracranial contours after image processing. The generated 2mm error could be verified by overlapping only contours of two images. Through this study, the radiation treatment efficiency could be improved by performing precise radiation therapy with a developed video based EPID and FSRT.

  • PDF