• Title/Summary/Keyword: Radiation device

Search Result 769, Processing Time 0.026 seconds

Evaluation of a Curtain-Type Radiation Protection Device for Veterinary Interventional Procedures

  • Minsik Choi;Jaepung Han;Changgyu Lim;Jiwoon Park;Sojin Kim;Uhjin Kim;Jinhwa Chang;Dongwoo Chang;Namsoon Lee
    • Journal of Veterinary Clinics
    • /
    • v.41 no.3
    • /
    • pp.157-164
    • /
    • 2024
  • The standard radiation protection method in the angiography suite involves the use of a thyroid shield, a lead apron, and lead glasses. However, exposure to substantial amounts of ionizing radiation can cause cataracts, tumors, and skin erythema. A newly developed curtain-type radiation protection device consists of a curtain drape composed of a five-layer bismuth and lead acrylic head-shielding plate, with both bearing an equivalent 0.25 mm lead thickness. In this study, a quality assurance phantom was used as the patient to create radiation scatter from the radiographic source, and an anthropomorphic mannequin phantom was used as the interventionalist to measure the radiation dose at seven different anatomical locations. Thermoluminescent dosimeters were used to measure the radiation dose. The experimental groups consisted of all-sided or one-sided curtain set-ups, the presence or absence of a conventional shielding system, and the orientation of beam irradiation. Consequently, the curtain-type radiation protection device exhibited better radiation protection range and capabilities than conventional radiation protection systems, especially in safeguarding the forehead, eyes, arms, and feet, with minimal radiation exposure. Moreover, the mean shielding ratios of the conventional shielding system and curtain-type radiation protection device were measured at 51.94% and 93.86%, respectively. Additionally, no significant decrease in the radiation protection range or capability was observed, even with changes in the beam orientation or one-sided protection. Compared with a conventional shielding system, the curtain-type radiation protection device decreased radiation exposure doses and improved comfort. Therefore, it is a potential new radiation protection device for veterinary interventional procedures.

A Study on Display Data of Radiation Point at 3 Dimensions (3차원 공간상 방사선원 위치 정보 표현에 관한 연구)

  • Lee, Seung-Min;Lee, Heung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1130-1132
    • /
    • 2007
  • In this research, 3D position exploring system was developed to detect direction and position of radiation source by using two general CCD camera. This system consists of a radiation detection device, a controlling device, and a monitoring device. A radiation detection device is composed of a collimator, a scintillator, CCD sensor, and radiation shielding part. Incident radiation is firstly collimated with direction and converted into visual lights in a scintillator. The CCD sensor detect the converted visual light and send a signal as an image. This can explore a radiation source with direction and distance from geometrical structure of two sensors. From these information, the developed 3D position exploring system can provide 3D radiation source information. This research will be useful for managing and processing radioactive materials in remote.

Optimization of Yonsei Single-Photon Emission Computed Tomography (YSECT) Detector for Fast Inspection of Spent Nuclear Fuel in Water Storage

  • Hyung-Joo Choi;Hyojun Park;Bo-Wi Cheon;Kyunghoon Cho;Hakjae Lee;Yong Hyun Chung;Yeon Soo Yeom;Sei Hwan You;Hyun Joon Choi;Chul Hee Min
    • Journal of Radiation Protection and Research
    • /
    • v.49 no.1
    • /
    • pp.29-39
    • /
    • 2024
  • Background: The gamma emission tomography (GET) device has been reported a reliable technique to inspect partial defects within spent nuclear fuel (SNF) of pin-by-pin level. However, the existing GET devices have low accuracy owing to the high attenuation and scatter probability for SNF inspection condition. The purpose of this study is to design and optimize a Yonsei single-photon emission computed tomography version 2 (YSECT.v.2) for fast inspection of SNF in water storage by acquisition of high-quality tomographic images. Materials and Methods: Using Geant4 (Geant4 Collaboration) and DETECT-2000 (Glenn F. Knoll et al.) Monte Carlo simulation, the geometrical structure of the proposed device was determined and its performance was evaluated for the 137Cs source in water. In a Geant4-based assessment, proposed device was compared with the International Atomic Energy Agency (IAEA)-authenticated device for the quality of tomographic images obtained for 12 fuel sources in a 14 × 14 Westinghouse-type fuel assembly. Results and Discussion: According to the results, the length, slit width, and septal width of the collimator were determined to be 65, 2.1, and 1.5 mm, respectively, and the material and length of the trapezoidal-shaped scintillator were determined to be gadolinium aluminum gallium garnet and 45 mm, respectively. Based on the results of performance comparison between the YSECT.v.2 and IAEA's device, the proposed device showed 200 times higher performance in gamma-detection sensitivity and similar source discrimination probability. Conclusion: In this study, we optimally designed the GET device for improving the SNF inspection accuracy and evaluated its performance. Our results show that the YSECT.v.2 device could be employed for SNF inspection.

Measurement of Skin Dose Distribution for the Mobile X-ray Unit Collimator Shielding Device (이동형 X선 장치 차폐도구 제작을 통한 표면선량 분포 측정)

  • Hong, Sun-Suk;Kim, Deuk-Yong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.5-8
    • /
    • 2010
  • Opened a court in February 10, 2006, a rule of safety management of the diagnosis radiation system was promulgated for safety of the radiation worker, patients and patients' family members. The purpose of this rule is to minimize the risk of being exposed to radiation during the process of handling X-ray. For this reason, we manufactured shielding device of mobile X-ray unit collimator for diminution of skin dose. Shielding device is made to a thickness of Pb 0.375mm. For portable chest radiography, we measured skin dose 50cm from center ray to 200cm at intervals of 20cm by Unfors Xi detector. As a result, a rule of safety management of the diagnosis radiation system has been strengthened. But there are exceptions, such as ER, OR, ICU to this rule. So shielding device could contribute to protect unnecessary radiation exposure and improve nation's health.

  • PDF

A Analysis of Medical Device Software Life Cycle Processes (의료용 소프트웨어생명주기 프로세스 분석)

  • Choi, Min-Yong;Kang, Young-Kyu;Hur, Chan-Hoi;Lee, Jeong-Rim;Park, Ki-Jung;Park, Hae-Dae;Lee, In-Soo;Kim, Hyeog-Ju
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2006.11a
    • /
    • pp.571-574
    • /
    • 2006
  • 2006년 5월 국제전기기술위원회(International Electrotechnical Commission, IEC) TC62(의료용전기기기기술위원회) SC62A(의료용전기기기 공통특성에 관한 세부분과위원회)에서 의료기기 소프트웨어의 생명주기 프로세스에 관한 국제규격인 IEC 62304, Ed.1을 제정하였다. 전체 내용은 크게 일반적인 요구사항(General requirements)과 소프트웨어 개발과 유지보수에 대한 프로세스(Software development & maintenance process)로 구성되어 있다. 그리고 소프트웨어 개발과 유지보수 프로세스가 진행되는 동안에 기본적으로 확보되어야 하는 소프트웨어 위험관리와 형상관리에 대한 프로세스 Software risk management & configuration management process)를 규정하고, 또한 문제 발생 시 이를 해결하기 위한 소프트웨어 문제 해결 프로세스(Software problem resolution process)를 규정하고 있다. 이는 기존의 정보통신 분야에서 사용되던 소프트웨어 생명주기 프로세스인 ISO/IEC 12207 규격과 외형상 많은 차이를 나타내고 있다. 이에 본 논문에서는 의료기기 소프트웨어의 생명주기 프로세스에 관한 국제규격인 IEC 652304를 분석하여 실제 의료용 소프트웨어 개발 및 유지보수 작업들이 어떠한 방식으로 이루어지는지를 분석하고, 또한 기존의 소프트웨어 생명주기 프로세스인 ISO/IEC 12207 규격과의 차이점을 비교 분석하여 본 규격에 대한 근본적인 활용 방안을 모색하고자 한다.

  • PDF

Study on Radiation Limit of ISM Equipment for Protecting Radio Device (무선기기 보호를 위한 ISM 기기의 방사 한계치에 관한 연구)

  • Shim, Yong-Sup;Lee, Il-Kyoo;Hong, Seon-Eui
    • Journal of Satellite, Information and Communications
    • /
    • v.6 no.2
    • /
    • pp.10-14
    • /
    • 2011
  • This paper suggests the method to calculate radiation limit of ISM(Industrial Scientific Medical) equipment in order to protect radio device in the situation that ISM equipment and radio device are operated in near distance. The factor for correction and protection ratio which is need for protecting radio device were considered to calculate radiation limit of ISM equipment. Also, the scenario which is required to limit radiation power of ISM equipment was referred and the S/W for calculation of radiation limit was developed by using GUI(Graphical User Interface) on Matlab. The suggested method for calculation of radiation limit of ISM equipment will be used to protect radio device from ISM equipment.

Development of shielding device for bremsstrahlung radiation from Y-90 microspheres (Y-90 microsphere 로부터 생성되는 제동복사선의 차폐를 위한 차폐체 개발 연구)

  • Park, Jun Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.50-53
    • /
    • 2019
  • Purpose Yttrium-90 (Y-90) is high-energy beta emitters ($E{\beta}$, max = 2.28 MeV) with the mean penetration depth of 2.5 mm in tissue. Radioactive microspheres containing Y-90 is widely used for the transarterial radioembolization of hepatocellular carcinoma. However, bremsstrahlung radiation from Y-90 can cause the external radiation exposure to medical staff who handle the Y-90 microspheres. In this study, shielding device for Y-90 microspheres was developed to minimize the external radiation exposure. Materials and Methods Y-90 microsphere shielding device was made from 6 mm thicknesses of tungsten including the lead glass window. Radiation shielding ability of Y-90 microsphere shielding device was evaluated using 4 GBq of $SIR-Spheres^{(R)}$ Y-90 microspheres. The bremsstrahlung radiation was measured using radiation survey meter. Results The mean radiation dose of Y-90 microspheres in acrylic shield was $261.7{\pm}2.3{\mu}Sv/h$ (n=5) at 10 cm away from the shield. With the additional tungsten shielding device, it was $23.7{\pm}1.3{\mu}Sv/h$ (n=5). Thus, the bremsstrahlung radiation dose was decreased by 90.9%. At 50 cm away from the shield, bremsstrahlung radiation was reduced by 89.2% after using tungsten shielding device. Conclusion During the preparation and radioembolization of Y-90 microsphere, medical staff are exposed to external radiation. In this study, we demonstrated that the use of tungsten shielding device devices significantly reduced the amount of bremsstrahlung radiation. Y-90 microsphere tungsten shielding device can be highly effective in reducing the bremsstrahlung radiation.

Study of Radiation Safety Management of Veterinary Hospital in Korea (동물병원 방사선 안전관리체계에 대한 연구)

  • Chae, Soo-young;Choi, Ho-jung;Lee, Young-won
    • Journal of Veterinary Clinics
    • /
    • v.37 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • This study investigated the effectiveness of radiation safety rules in animal hospital and the awareness and behavior of veterinary radiation workers. With the questionnaires, the data was collected from randomly selected veterinarians in animal hospitals and animal medical imaging centers. Collected data were about radiation device, shielding device, regulations, safety management, education, knowledge, behavior and awareness. Frequency, correlation and multiple regression analysis were performed. The medical devices related with radiation in animal hospital were X-ray (59%), CT (15%), fluoroscopy (12%), mobile X-ray (12%) and others (2%). The number of people using radiation shielding device is high. The answers were low on knowing radiation related regulation and receiving radiation protection education. The group with higher knowledge and awareness shows positive correlation with safety behavior. The increase of use of the radiation related medical devices in veterinary hospital causes the increase of radiation exposure risk. This study suggests that radiation safety management system and policies need to be developed to protect radiation workers and give them correct information and consciousness.

Practicability Assessment of Spherical Mechanical Check Device(SMCD) (Mechanical Check용 Spherical device의 제작 및 특성 평가)

  • Lee, Byung-Koo;Yang, Dae-Sik;Kweon, Young-Ho;Ko, Shin-Gwan;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.153-159
    • /
    • 2007
  • Digital medical image commenced with an introduction of PACS has become more popular today in the radiation diagnosis and radiation treatment and made great progress, in particular, for medical testing field, whereas it has made slow progress for radiation treatment field. In order to accommodate the current trend of digital from analog, a spherical mechanical check device(SMCD) that is the form of spherical differing from the existing form of flat or cube has been designed and tested its practicability to replace the part in mechanical check with digital image from QA operation. If the distance maintains constance between source(target) and image detector with constant distance to the center of spherical mechanical check device(SMCD), the size will be shown as a constant image at all times regardless of its direction exposed. For the test, two accurate hemispheres are made and put together which results in a sphere of the equilateral circle. It enables a variety of implementation of the existing mechanical check using digital image as follows: congruity level of radiation field and light field, size accuracy of radiation field and collimation field, gantry rotation isocenter check, collimation rotation isocenter check, room laser accuracy check, collimation rotation angle check, couch rotation angle check, and more. In addition, it has proved its practicability in checking isocenter congruity level as real time at the time of simultaneous rotation between gantry and couch that is applied to the non-coplanar field, which had been hard to apply as a device formed of existing flat or cube.

  • PDF

Development of Tomotherapy couch device capable of yaw-directional correction (Yaw방향의 보정이 가능한 Tomotherapy couch device의 개발)

  • Chae, Moon Ki;Kwon, Dong Yeol;Sun, Jong Lyool;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.139-151
    • /
    • 2018
  • Objectives : A self-made "Tomotherapy couch device" capable of correcting the Yaw direction was fabricated and evaluated for its usefulness. Materials and Methods : "Tomotherapy couch device" capable of correcting the Yaw direction is made of rigid fibreboard with a flexural strength of $200kg/cm^2$. CBCT Image from Novalis Tx and Iso-Align Phantom from MED-TEC were used to evaluate the physical accuracy. The treatment plan was designed using Accuray $Precision^{TM}$ and In House Head and Phantom. Accuray $PrecisionART^{TM}$ and $Precision^{TM}$ was used to evaluate dose. Results : Evaluation results, the self-fabricated device accurately corrected the setup error, Target dose was within 95 %~107 % of all. In order to directly evaluate the OAR dose according to the Yaw change, the absolute dose was measured. As a result, when the error in the Yaw direction was $3^{\circ}$, the specific OAR showed a maximum difference of 18.4 %. Conclusion : "Tomotherapy couch device" capable of correcting the Yaw direction can be manufactured at a lower cost compared to the effect, and it can prevent the patient's MVCT image dose for re-imaging. Accurate radiation therapy without errors can be performed.

  • PDF