• Title/Summary/Keyword: Radiation detection

Search Result 775, Processing Time 0.025 seconds

Detection Properties of Irradiated Dried Fruits by Using Photo-stimulated Luminescence, Thermoluminescence, and Electronspin Resonance Methods (물리적인 방법(PSL, TL, ESR)을 이용한 방사선 조사 건조과일의 검지 특성)

  • Yoon, Young-Min;Park, Jae-Nam;Choi, Soo-Jeong;Park, Jong-Heum;Kim, Jae-Kyung;Byun, Eui-Baek;Lee, Ju-Woon;Han, In-Jun;Park, Jin-Gyu;Kim, Jae-Hun;Song, Beom-Seok
    • Journal of Radiation Industry
    • /
    • v.8 no.1
    • /
    • pp.11-15
    • /
    • 2014
  • In this study, we investigated the applicability of the photostimulated luminescence (PSL), thermoluminescence (TL) and electron spin resonance (ESR) methods for freeze dried fruits which are not allowed to be irradiated in Korea. Apples and persimmons samples that had been dried with a freeze drier were irradiated at a dose of 1, 3, 5, 7, and 10 kGy, using a gamma radiator with a cobalt-60 source. With the PSL method, the dried apples showed photon counts of less then 700 counts/60 s (negative) in all the samples, whereas the dried persimmons that were gamma-irradiated above 3 kGy yielded photon counts of between 700 and 5,000 counts/60 s (intermediate). The TL results showed that this technique is useful for detecting irradiated samples; the TL ratios ($TL_1/TL_2$) measured for the food samples at an irradiation dose of 1 kGy were 0.13 for dried apples and 0.79 for dried persimmons. With regard to the results of ESR spectroscopy, the strength of the ESR signals from the dried fruits increased linearly in a dosedependent manner. However, the characteristic signal was not found in all the samples. In conclusion, the TL methods only can be used for the detection of gamma-irradiated dried apples and persimmons.

Quantitative Analysis of Radiation-induced Hydrocarbons in Irradiated Chicken at Various Dose Levels

  • Kim, Eun-Ah;Lee, Hae-Jung;Yang, Jae-Seung;Kim, Kyong-Su
    • Preventive Nutrition and Food Science
    • /
    • v.3 no.4
    • /
    • pp.339-343
    • /
    • 1998
  • Gamma-irradiated chicken at dose levels of 0.1 to 10 kGy was subjected to detection of radiation-induced hydrocarbons whether irradiated or not. The hydrocarbons extracted from chicken fat were separated by florishil column chromatography and identified with GC-FID and GC/MS methods. Eight kinds of hydrocarbons were identified from irradiated chicken, among which 1, 7-hexadecadiene and 8-heptadencene were detected as major compounds , Remarkably radiation-induced hydrocarbons in irradiated chiken were detected at 0.5kGy and over. The concentration of radiation-induced hydrocarbons was relatively constant during 16 weeks.

  • PDF

Signal Characteristics of Ultra-high Frequency Radiation from Partial Discharge in Insulation Oil (절연유에서 부분방전에 의한 극초단파 신호 특성분석)

  • Ju, Hyoung-Jun;Goo, Sun-Geun;Park, Ki-Jun;Han, Ki-Seun;Yoon, Jin-Yul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.1
    • /
    • pp.56-59
    • /
    • 2008
  • We have designed 4 types(void in insulation paper, protrusion electrode, floating electrode, surface discharge) of partial discharge(PD) defect to simulate typical faults found in oil filled power transformers. Ultra-high frequency(UHF) radiation due to PD was measured using a UHF measuring system and a conventional PD measuring system, simultaneously. Electromagnetic radiation spectra of these defects show UHF radiation up to about 1.5-2 GHz range. The phase resolved partial discharge(PRPD) patterns of UHF radiation from the PD defects were also measured and the pattern reveals distinct feature for each defect types. The UHF measuring could be used to detect PDs in oil filled transformers and analysis of the PRPD pattern should provide useful information on origin of PD signal.

A Study of Real Time Verification System or Radiation Therapy (방사선치료 위치 실시간 검증시스템에 관한 연구)

  • Kim, Y.J.;Ji, Y.H.;Lee, D.H.;Lee, D.H.;Hong, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.164-167
    • /
    • 1997
  • The treatment setup of patients during irradiation is an important aspect in relation to the success of radiotherapy. Imaging with the treatment beam is a widely used method or verification of the radiation field position relative to the target area, prior to or during irradiation. In this paper, Real time digital radiography system was implemented or verification of local error between simulation plan and radiation therapy machine. Portal image can be acquired by CCD camera, image board and pentium PC after therapy Radiation was converted into light by a metal/fluorescent Screen. The resulting image quality is comparable to film, so the imaging system represents a promising alternative to film as a method of verifying patient positioning in radiotherapy. Edge detection and field size measurement were also implemented and detected automatically for verification of treatment position. Field edge was added to the original image or checking the anatomical treatment verification by therapy technicians. By means of therapy efficiency improvement and decrease of Radiation side effects with these techniques, Exact Radiation treatments are expected.

  • PDF

Radiation-Induced Malignant Melanoma Following Radiation Treatment for Squamous Cell Carcinoma of the Oral Cavity - A Case Report and Review of Literature - (구강내 편평상피세포암의 방사선치료 후 발생한 악성 흑색종 - 증례보고 및 문헌고찰 -)

  • Shin, Young-Ju;Yang, Koang-Mo;Suh, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.87-90
    • /
    • 1998
  • Malignant melanoma of the oral cavity is rare, accounting for 1 to $8\%$ of all malignant melanomas. The overall prognosis remains poor despite the available treatments such as radical surgery, adjuvant radiotherapy, chemotherapy and immunotherapy due to failure in early detection and tendency in early metastasis. The etiology of mucosal malignant melanoma remains unkown. However, there are few cases of malignant melanoma of the oral cavity reported in the literature, which might be related to preexisting melanosis and radiation treatment. A case with malignant melanoma developed on the same site after 6 years following irradiation for squamous cell carcinoma of the oral cavity is reported in this article.

  • PDF

A Study of Interface Layer on CdZnTe Radiation Sensor for Potable Isotope Identifier (이동형 핵종 분석 장치용 CZT 반도체 검출기의 완충전극에 대한 연구)

  • Cho, Yun Ho;Park, Se-Hwan;Kim, Yong Kyun;Ha, Jang Ho
    • Journal of Radiation Industry
    • /
    • v.5 no.1
    • /
    • pp.95-99
    • /
    • 2011
  • The electrical and mechanical properties of electrode for radiation detection are very important. In general, Au electrode and CZT crystal are combined to form ohmic contacts, and the best energy resolution is shown at the Au electrode. The metal contacts are fabricated by electroless deposition method, sputtering deposition method and thermal evaporation method. The electrode fabrication is easy with use of the thermal evaporation method, while an adhesive strength is weak. Thus interface materials such as Ag, Al and Ni were investigated to overcome defects generated by the this method. The thickness of the interface material between the Au electrode and the CZT crystal was 100 Angstroms, the Au electrode with thickness of 400 Angstroms was deposited. The Al+Au electrode is shown that the results of current-voltage and radiation response are similar to results of Au electrode.

Opportunistic investigation of vascular calcification using 3-dimensional dental imaging

  • Masoud MiriMoghaddam;Hollis Lai;Camila Pacheco-Pereira
    • Imaging Science in Dentistry
    • /
    • v.54 no.3
    • /
    • pp.283-288
    • /
    • 2024
  • Purpose: Given the growing use of cone-beam computed tomography (CBCT) scans, this study assessed radiation exposure from these scans in the context of national guidelines and recommended dose limits. Materials and Methods: The current literature was reviewed to quantify the benefit of opportunistic diagnosis of carotid artery calcification relative to the potential risk of radiation-induced cancer. Results: The average radiation from CBCT at its largest field of view and highest resolution possible amounts to a reasonable but still low ionizing radiation exposure. This exposure is comparable to 22 days of background radiation and is notably lower than the radiation exposure from medical CT scans. According to the risk assessment analysis, the risk of stroke events involving internal and external carotid artery calcification (CAC) was 202 and 67 per 100,000 individuals, respectively. In contrast, the estimated risk of radiation-induced cancer associated with CBCT was notably lower, at 0.6 per 100,000. Conclusion: The present study advocates for a comprehensive assessment of CBCT scans encompassing the areas of the internal and external carotid arteries by a knowledgeable professional, given the potential advantages of early detection of vascular abnormalities. Dental professionals who take scans involving these areas need to be mindful of reporting these findings and refer patients to their primary care physician for further investigation.

Detection Characteristics of a Novel Coupler for GIS PD Detection

  • Park, Jae-Gu;Yi, Sang-Hwa;Kim, Kwang-Hwa;Kim, Ik-Soo;Kim, Jae-Chul
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.6
    • /
    • pp.224-229
    • /
    • 2003
  • An ultra high frequency (UHF) coupler possessing ultra wide band (UWB) characteristics ranging from hundreds of MHz to several GHz is desirable for the detection of the partial discharge (PD) pulses because the pulses propagate with rise time shorter than one nanosecond in a gas-insulated substation (GIS). Thus, the authors have proposed a log-periodic antenna for GIS PD detection. Various parameters of the coupler such as frequency bandwidth, coupler gain, radiation pattern, and coupler geometry were considered throughout the simulations. The experiments for the detection characteristics of the coupler were carried out in the mock-up GIS chamber. The results indicated that the detection characteristics of the coupler are dependent on the installation angle of the coupler, the position of the coupler in the hand hole and the existence of the spacer.

Halide Perovskites for X-ray Detection: The Future of Diagnostic Imaging

  • Nam Joong Jeon;Jung Min Cho;Jung-Keun Lee
    • Progress in Medical Physics
    • /
    • v.33 no.2
    • /
    • pp.11-24
    • /
    • 2022
  • X-ray detection has widely been applied in medical diagnostics, security screening, nondestructive testing in the industry, etc. Medical X-ray imaging procedures require digital flat detectors operating with low doses to reduce radiation health risks. Recently, metal halide perovskites (MHPs) have shown great potential in high-performance X-ray detection because of their attractive properties, such as strong X-ray absorption, high mobility-lifetime product, tunable bandgap, low-temperature fabrication, near-unity photoluminescence quantum yields, and fast photoresponse. In this paper, we review and introduce the development status of new perovskite X-ray detectors and imaging, which have emerged as a new promising high-sensitivity X-ray detection technology. We discuss the latest progress and future perspective of MHP-based X-ray detection in medical imaging. Finally, we compare the conventional detection methods with quantum-enhanced detection, pointing out the challenges and perspectives for future research directions toward perovskite-based X-ray applications.

A Review of Dose Rate Meters as First Responders to Ionising Radiation

  • Akber, Aqeel Ahmad;Wiggins, Matthew Benfield
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.3
    • /
    • pp.97-102
    • /
    • 2019
  • Background: Dose rate meters are the most widely used, and perhaps one of the most important tools for the measurement of ionising radiation. They are often the first, or only, device available to a user for an instant check of radiation dose at a certain location. Throughout the world, radiation safety practices rely strongly on the output of these dose rate meters. But how well do we know the quality of their output? Materials and Methods: This review is based on the measurements 1,158 commercially available dose rate meters of 116 different makes and models. Expected versus the displayed dose patterns and consistency was checked at various dose rates between $5{\mu}Gy{\cdot}h^{-1}$ and $2mGy{\cdot}h^{-1}$. Samples of these meters were then selected for further investigation and were exposed to radiation sources covering photon energies from 50 keV to 1.5 MeV. The effect of detector orientation on its reading was also investigated. Rather than focusing on the angular response distribution that is often reported by the manufacturer of the device, this study focussed on the design ergonomics i.e. the angles that the operator will realistically use to measure a dose rate. Results and Discussion: This review shows the scope and boundaries of the ionising radiation dose rate estimations that are made using commonly available meters. Observations showed both inter and intra make and model variations, occasional cases of instrument failure, instrument walk away, and erroneous response. Conclusion: The results indicate the significance of selecting and maintaining suitable monitors for specific applications in radiation safety.