• Title/Summary/Keyword: Radiation detection

Search Result 763, Processing Time 0.036 seconds

CHARACTERISTICS OF FABRICATED SiC RADIATION DETECTORS FOR FAST NEUTRON DETECTION

  • Lee, Cheol-Ho;Kim, Han-Soo;Ha, Jang-Ho;Park, Se-Hwan;Park, Hyeon-Seo;Kim, Gi-Dong;Park, June-Sic;Kim, Yong-Kyun
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.70-74
    • /
    • 2012
  • Silicon carbide (SiC) is a promising material for neutron detection at harsh environments because of its capability to withstand strong radiation fields and high temperatures. Two PIN-type SiC semiconductor neutron detectors, which can be used for nuclear power plant (NPP) applications, such as in-core reactor neutron flux monitoring and measurement, were designed and fabricated. As a preliminary test, MCNPX simulations were performed to estimate reaction probabilities with respect to neutron energies. In the experiment, I-V curves were measured to confirm the diode characteristic of the detectors, and pulse height spectra were measured for neutron responses by using a $^{252}Cf$ neutron source at KRISS (Korea Research Institute of Standards and Science), and a Tandem accelerator at KIGAM (Korea Institute of Geoscience and Mineral Resources). The neutron counts of the detector were linearly increased as the incident neutron flux got larger.

Detection of Gamma-irradiated Red and Black Pepper Powders in a Model Meat Product by Photostimulated Luminescence

  • Shin, Mee-Hye;Yoon, Yo-Han;Sharma, Arun Kumar;Lee, Ju-Woon
    • Food Science of Animal Resources
    • /
    • v.30 no.2
    • /
    • pp.232-235
    • /
    • 2010
  • This study examined the photostimulated luminescence (PSL) detection method suggested by the Korean Food and Drug Administration to assess whether the method can be used to identify irradiated spices in restructured pork patties, which served as a model system for processed meat products. Red and black pepper powders were irradiated at 0, 5.0, 7.5, and 10 kGy, and pork patties were formulated with the spice at irradiated pepper concentrations of 0.1% and 0.5%. PSL was then used to estimate amounts of light derived from the spice itself and pork patties. The results of PSL analysis showed that red and black pepper powders were determined as positive and presumptive positive, respectively, when irradiated at more than 7.5 kGy. However, when used in pork patties, all samples were negative for irradiation. Thus, PSL may not be useful in detecting irradiated ingredients used in processed meat products.

A NUMERICAL SIMULATION OF INFRARED RADIATION OF EXHAUST PLUME (배기 후류의 적외선 방사 특성 모사를 위한 수치적 연구)

  • Zhang, Y.;Yang, Y.R.;Park, G.R.;Myong, R.S.;Cho, T.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.422-425
    • /
    • 2010
  • The infrared radiation of exhaust plume was investigated numerically by a finite volume method (FVM) with anisotropic scattering particles. The exhaust plume is considered to absorb, emit and scatter radiant energy isotropically as well as anisotropically. The spatial and spectral distribution characteristics were obtained for the detection wavelength with $2.7{\mu}m$. The radiative intensities were presented for the different detective direction.

  • PDF

Numerical Study of Sound Radiation from curved intake (굴곡형 흡입관에서의 소음 방사 해석)

  • Shim I. B.;Lee D. J.;Ahn C. S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.88-94
    • /
    • 2002
  • Curved intakes are commonly used from commercial aircraft to military missile. Sound radiation from the intake of air vehicle affects cabin noise, community noise and military detection. In this paper, Sound radiation from curved intake is computed using the high order, high resolution scheme. The generalized characteristic boundary conditions, adaptive nonlinear artificial dissipation model and conformal mapping for high order, high resolution scheme are used. The geometric change of curved intake and the frequency of acoustic source are considered. Two dimensional Euler equations are solved for theses analyses.

  • PDF

A Study on the Characteristics of Smartphone Camera as a Medical Radiation Detector (의료 방사선 검출기로써 스마트폰 카메라의 특성에 관한 연구)

  • Kang, Han Gyu;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.5
    • /
    • pp.143-151
    • /
    • 2016
  • The aim of this study is to investigate the optimal algorithm to extract medical radiation induced pixel signal from complementary metal-oxide semiconductor (CMOS) sensors of smartphones camera. The pixel intensity and pixel number of smartphone camera were measured as the X-ray dose was increased. The front camera of the smartphone camera has low noise property and excellent dose response as compared to the back camera of the smartphone. The indirect method which uses scintillation crystal in front of the smartphone camera, couldn't improve the X-ray detection efficiency as compared to the direct method which does not use any scintillator in front of the smartphone camera. When we used the algorithm which employing threshold level on the pixel intensity and pixel number, the dose linearity was more higher for the pixel intensity rather for the pixel number. The use of pixel intensity of Y color component which represents the grey scale, would be efficient in terms of the radiation detection efficiency and reducing the complexity of the image processing. We expect that the radiation dose monitoring can be managed effectively and systematically by using the proposed radiation detection algorithm, thus eventually will contribute to the public healthcare.

Evaluation of a Fabricated Charge Sensitive Amplifier for a Semiconductor Radiation Detector

  • Kim, Han-Soo;Ha, Jang-Ho;Park, Se-Hwan;Lee, Jae-Hyung;Lee, Cheol-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.2
    • /
    • pp.81-84
    • /
    • 2010
  • A CSA(Charge Sensitive Amplifier) was designed and fabricated for application in a radiation detection system based on a semiconductor detector such as Si, SiC, CdZnTe and etc.. A fabricated hybrid.type CSA was evaluated by comparison with a commercially available CSA. A comparison was performed by using calculation of ENC (Equivalent Noise Charge) and by using energy resolutions of fabricated radiation detectors based on Si. In energy resolution comparison, a fabricated CSA showed almost the same performance compared with a commercial one. In this study, feasibility of a fabricated CSA was discussed.

Field tests of the radiation detectors for environmental radiation monitoring around KORI nuclear power plants (고리원자력 주변 환경방사선 감시를 위한 방사선 측정기의 현장 성능 시험)

  • 최성수;신대용;조규성;하달규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1371-1374
    • /
    • 1997
  • We had developed the on-line environmental monitoring system which has installed around Kori Nuclear Power Plants and will be taken the place of the existing system. The system consists of a main computer and 11 sets of radiation monitoring post equipments. Nal(Tl) scintillation detectro was adopted in addition to ion-chamber detector and implemented with DCU(Dose Conversion Unit) and SCA(Single Channel Analyzer). Compared with the existing system, it has revised feature in the radiation measurements which are detection of artificial radioactivity and 2-ways of the radiatiion detectors. The field test trsults show that the developed radiation detecting equipments can measure environmental radiation withn 5.0% of the theoretical value.

  • PDF

RADIATION SAFETY STUDIES AT TOHOKU UNIVERSITY CYRIC

  • Yamadera M. Baba A.;Miura T.;Aoki T.;Hagiwara M.;Kawata N.
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.231-236
    • /
    • 2001
  • A brief introduction is presented on the radiation safety studies at Tohoku University Cyclotron & Radioisotope Center. Studies on two subject are described; (1) measurement of the thick target neutron yield and radioisotope production / activation cross section for ten's of MeV neutrons and ions using K=110 Tohoku University cyclotron to provide basicdata for accelerator shielding, and (2) development of techniques for high sensitive radiation detection and profile measurement using an Imaging Plate which is a high sensitive two-dimensional radiation sensor. Application of the Imaging Plate techniques to localization of very weak radioactivity and to neutron profile measurement is described.

  • PDF

Development and Application of the Semiconductor Neutron Radiation Detector (반도체 중성자 탐지소자 개발 및 응용)

  • Lee, Nam-Ho;Lee, Hong-Kyu;Youk, Young-Ho
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.299-304
    • /
    • 2011
  • In this paper, we developed the semiconductor neutron radiation detector and the multi-purpose radiation detection technologies for the next generation military personal surveymeter. The PIN type semiconductor neutron detector and the prototype measure the neutron radiation dose upto 1,000cGy with ${\pm}20%$ error. It also have a good performance about the Gamma, Alpha and Beta radiation and MIL-STD-810F.

The Relationship between Radiation-Induced Apoptosis and the Expression of Cytokines in the Rat's Liver (백서 간에서 방사선조사에 의한 Apoptosis와 Cytokine 발현과의 관계)

  • An Eun Joo;Lee Kyung-Ja;Rhee Chung-Sik
    • Radiation Oncology Journal
    • /
    • v.18 no.3
    • /
    • pp.205-213
    • /
    • 2000
  • Purpose : To determine the role of cytokines in the apoptosis of rat's liver following irradiation. Materials and Methods : Sprague-Dawley rats were irradiated to entire body with a single dose of 8 Gy. The rats were divided Into 5 groups according to the sacrlfice day after irradiation. The liver and blood after 1, 3, 5, 7, and 14 days irradiation were sampled for evaluation of mechanism of apoptosis and role of cytokine in relation to radiation-induced tissue damage. The study was composed of microscopic evaluation of liver tissue, in situ detection method for apoptosis, immunohistochemical stain of IL-1, IL-4, IL-6 and TNF, bioassay and radioimmunoassay of IL-6 in liver tissue and blood. Results : Radiation-induced liver damage was noted from first day of radiation, and most severe parenchymal damage associated with infiltration of chronic inflammatory cells was seen in the groups of 5 days after radiation. A number of apoptosis were observed 1 day after radiation on both light microscope and in situ method. Afterwards, the number of apoptosis was gradually diminished. On immunohistochemical study, IL-1 and TNF were expressed 1, 3 days after radiation, but not expressed after that. IL-4 was not expressed in the entire groups. IL-6 was expressed with strong positivity in 1, 3 days after radiation. Bioassay and RIA of IL-6 in liver tissue and blood showed the highest value in 1 day after radiation, and the value is diminished after then. Conclusion. Apoptosis seemed to be the important mechanism of radiation-induced liver damage, and is possibly induced by the release of cytokines, such as IL-1, IL-6, TNF in view the simultaneously increased appearance of pooptosis and cytokines.

  • PDF