• 제목/요약/키워드: Radiation degradation

검색결과 289건 처리시간 0.033초

Analysis of X-Band Link Performance Degradation Caused by Adjacent Satellite

  • Park, Durk-Jong;Ahn, Sang-Il;Chun, Yong-Sik;Kim, Eun-Kyou
    • Journal of Astronomy and Space Sciences
    • /
    • 제28권4호
    • /
    • pp.299-304
    • /
    • 2011
  • As more satellites are designed to downlink their observed image data through the X-band frequency band, it is inevitable that the occupied bandwidth of a target satellite will overlap with that of other X-band downlink satellites. For sun-synchronized low earth orbit satellites, in particular, it can be expected that two or more satellites be placed within the looking angle of a ground station antenna at the same time. Due to the overlapping in the frequency band, signals transmitted from the adjacent satellites act as interferers, leading to degraded link performance between target satellite and ground station. In this paper, link analysis was initiated by modeling the radiation pattern of ground station antenna through a validated Jet Propulsion Laboratory peak envelope model. From the relative antenna gain depending on the offset angle from center axis of maximum antenna directivity, the ratio of received interference signal level to the target signal level was calculated. As a result, it was found that the degradation increased when the offset angle was within the first point of radiation pattern. For a 7.3 m antenna, serious link degradation began at an offset angle of 0.4 degrees. From this analysis, the link performance of the coming satellite passes can be recognized, which is helpful to establish an operating procedure that will prevent the ground station from receiving corrupted image data in the event of a degraded link.

인위적인 자외선 조사량에 따른 폴리머애자에서의 코로나 방전 특성 (A Study of Corona Discharge in Polymer Insulators by Artificial UV Radiation)

  • 김영석;최명일;김종민;방선배;송길목;곽동순
    • 전기학회논문지
    • /
    • 제62권5호
    • /
    • pp.643-648
    • /
    • 2013
  • In this study, degradation was observed by irradiating UV rays to the polymer insulators which have been widely used in outdoor electric power facilities. For an indoor accelerated UV test, 0.55 w/m2 of UV rays were applied using a xenon-arc method. A UV detection system with 65 ${\phi}mm$ in diameter, 100 mm in length and 1.0 of brightness (F/#) has been designed. Even though efflorescence on the surface of polymer insulators wasn't observed according to the accelerated UV test. UV rays were detected at around 50% and 40% of insulation breakdown in EPDM and silicone-type insulators respectively. As degradation continued because of an indoor accelerated UV test, breakdown voltage with which UV rays can be detected in an early stage decreased as well. A silicone polymer insulator would be severer than EPDM polymer insulator in terms of surface degradation because of UV strength against $V_m/V_{BD}$ was high in silicone polymer insulators. UV strength in silicone-type insulators increased at 1,000 $kJ/m^2$ because contact angle at the intial stage sharply decreased to from $113^{\circ}$ to $92.1^{\circ}$.

PET-MR 시스템에 적용을 위한 실리콘 광증배센서의 온도 변화에 따른 성능 열화 분석 (An Analysis on Performance Degradation of Silicon Photomultipliers over Temperatures Variation for PET-MR Application)

  • 박경진;김형택;임경택;조민식;김기윤;조규성
    • 방사선산업학회지
    • /
    • 제9권3호
    • /
    • pp.143-151
    • /
    • 2015
  • A PET-MR system is particularly useful in diagnosing brain diseases. We have developed a prototype positron emission tomography (PET) system which can be inserted into the bore of a whole-body magnetic resonance imaging (MRI) system that enables us to obtain PET and MRI images simultaneously with a reduced cost. Silicon photomultipliers (SiPM) are appropriated as a PET detector at PET/MR system because detectors have a high gain and are insensitive to magnetic fields. Despite of its improved performance compared to that of PMT-based detectors, there is a problem of the photo-peak channel shift which is due to the increase of the temperature inside the ring detector. This problem will occur decreasing sensitivity of the PET and image distortion. In this paper, I quantitative analyze parameters of the KAIST SiPM depending on temperature by experiments. And I designed cooling methods in consideration of the degradation of sensors for correction of the temperature in the PET gantry. According to this research, we expect that distortive images and degradation of the sensitivity will not be occurred with using the above idea to reduce heat even if the PET system operates for a long time.

부분적으로 $^{60}Co-{\gamma}$선 조사된 EPR 케이블의 절연열화 특성에 관한 연구 (Electrical Degradation Properties of EPR Cable Partially Irradiated by $^{60}Co-{\gamma}$ Rays)

  • 이성일
    • Elastomers and Composites
    • /
    • 제33권4호
    • /
    • pp.238-245
    • /
    • 1998
  • 이 논문은 원자력발전소에서 사용되고 있는 부분적으로 방사선 조사된 EPR 전력 케이블의 방사선 절연열화 진단을 행하기 위해서 전기특성을 조사한 것이다. 본 연구에서는 방사선 조사량을 100Mrad부터 200Mrad까지 증가시킨 케이블 시료를 열화비율에 따른 방사선 조사량에 의한 충전전류 및 방전전류를 측정한 결과 $4.3{\times}10^{-9}$(A)로부터 $1.03{\times}10^{-7}$(A)로 증가함을 알 수 있었다. 또한 100% 일때의 충전전류 및 방전전류를 50%, 16.7% 일때를 비교하면 후자의 케이블은 열화된 부분의 길이가 1/2, 1/6로 되므로 충전전류 및 방전전류로 1/2, 1/6로 흐름을 알 수 있었다. 열화하지 않은 22m와 66m의 케이블을 조사한 결과 66m의 케이블 시료쪽이 충전전류 및 방전전류 값이 22m 케이블보다 3배나 크다는 것을 확인했다. 이들 결과로부터 방사선을 조사한 EPR 케이블의 절연열화 진단법으로 충전전류 및 방전전류를 측정하는 것이 가능하다는 것을 확인했다.

  • PDF

Resveratrol Inhibits Oesophageal Adenocarcinoma Cell Proliferation via AMP-activated Protein Kinase Signaling

  • Fan, Guang-Hua;Wang, Zhong-Ming;Yang, Xi;Xu, Li-Ping;Qin, Qin;Zhang, Chi;Ma, Jian-Xin;Cheng, Hong-Yan;Sun, Xin-Chen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권2호
    • /
    • pp.677-682
    • /
    • 2014
  • Resveratrol has been examined in several model systems for potential effects against cancer. Adenosine monophosphate-activated protein kinase (AMPK) is reported to suppress proliferation in most eukaryocyte cells. Whether resveratrol via AMPK inhibits proliferation of oesophageal adenocarcinoma cells (OAC) is unknown. The aim of this study was to determine the roles of AMPK in the protective effects of resveratrol in OAC proliferation and to elucidate the underlying mechanisms. Treatment of cultured OAC derived from human subjects or cell lines with resveratrol resulted in decreased cell proliferation. Further, inhibition of AMPK by pharmacological reagent or genetical approach abolished resveratrol-suppressed OAC proliferation, reduced the level of $p27^{Kip1}$, a cyclin-dependent kinase inhibitor, and increased the levels of S-phase kinase-associated protein 2 (Skp2) of $p27^{Kip1}$-E3 ubiquitin ligase and 26S proteasome activity reduced by resveratrol. Furthermore, gene silencing of $p27^{Kip1}$ reversed resveratrol-suppressed OAC proliferation. In conclusion, these findings indicate that resveratrol inhibits Skp2-mediated ubiquitylation and 26S proteasome-dependent degradation of $p27^{Kip1}$ via AMPK activation to suppress OAC proliferation.

디지털 래디오그라피의 신호 및 잡음 특성에 대한 방사선 영향에 관한 연구 (Investigation of Radiation Effects on the Signal and Noise Characteristics in Digital Radiography)

  • 김호경;조민국
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권6호
    • /
    • pp.756-767
    • /
    • 2007
  • For the combination of phosphor screens having various thicknesses and a photodiode array manufactured by complementary metal-oxide-semiconductor (CMOS) process, we report the observation of image-quality degradation under the irradiation of 45-kVp spectrum x rays. The image quality was assessed in terms of dark pixel signal, dynamic range, modulation-transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). For the accumulation of the absorbed dose, the radiation-induced increase both in dark signal and noise resulted in the gradual reduction in dynamic range. While the MTF was only slightly affected by the total ionizing dose, the noise power in the case of $Min-R^{TM}$ screen, which is the thinnest one among the considered screens in this study, became larger as the total dose was increased. This is caused by incomplete correction of the dark current fixed-pattern noise. In addition, the increase tendency in NPS was independent of the spatial frequency. For the cascaded model analysis, the additional noise source is from direct absorption of x-ray photons. The change in NPS with respect to the total dose degrades the DQE. However, with carefully updated and applied correction, we can overcome the detrimental effects of increased dark current on NPS and DQE. This study gives an initial motivation that the periodic monitoring of the image-quality degradation is an important issue for the long-term and healthy use of digital x-ray imaging detectors.

단파장 자외선(254 nm)에 노출된 고밀도 폴리에틸렌 수지의 카르보닐 지수(CI)와 기계적 물성 변화의 관계에 관한 연구 (A Study on the Relationship of Change of Mechanical Properties and Carbonyl Index Induced through Short-wavelength Ultraviolet Radiation (254 nm) for High Density Polyethylene)

  • 김창환;신진용
    • 공업화학
    • /
    • 제24권2호
    • /
    • pp.138-143
    • /
    • 2013
  • 화학적 열화를 빠르게 유도할 수 있는 단파장의 자외선(254 nm)을 고밀도 폴리에틸렌의 표면에 조사하여, 생성된 carbonyl band의 변화로부터 기계적 물성 변화를 예측할 수 있는 지에 대한 가능성을 연구하였다. 오랜 시간이 요구되는 자연 태양광에 의한 옥외폭로시험이나, 제논-아크 광원에 의한 광 열화 대신에 광양자 에너지가 높은 UVC 램프를 사용함으로써, 유도되는 광열화의 화학적 특성이 동일한 기계적 물성 변화를 유발하는지를 확인하는 것에 본 연구의 의미가 있다. 인장시험과 크리프-파괴시험으로 진행된 고밀도 폴리에틸렌의 기계적 강도는 CI 변화에 유사한 양상을 보였으며, 특히 항복강도와 신장률은 자외선 노출시간과 밀접한 관계가 있음을 보여주었다. 따라서 빠른 표면 열화를 유발하는 UVC 램프를 활용한 카르보닐 지수와 기계적 물성 변화의 관계를 통하여 장시간이 요구되는 옥외에서의 기계적 물성변화를 보다 빠르게 파악할 수 있는 방법을 제시하였다.

감마선조사에 의해 영향을 받은 단체급식용 구운 어묵의 미생물학적 품질과 이화학적 변화 (Microbial Quality and Physiochemical Changes of Grilled Fish Paste in a Group-Meal Service Affected by Gamma-Irradiation)

  • 김장호;전진용;유상렬;김영지;서정식;이주운;변명우
    • 한국식품저장유통학회지
    • /
    • 제11권4호
    • /
    • pp.522-529
    • /
    • 2004
  • In the grilled fish paste stored at $5^{\circ}C$, the total aerobic bacterial counts were effectively reduced by 2.5 kGy or more. In the samples stored at $30^{\circ}C$, the total aerobic bacterial counts of the samples irradiated at 7.5 kGy were below to the limit of detection (2 log CFU/g). The TBA values of the irradiated samples were considerably higher than those of the controls but not proportional to the irradiation dose. It is apparent that an irradiation treatment causes very little textural degradation and the sensorial quality of the sample was maintained by an irradiation at 7.5 kGy or more.

급전 기판의 유전상수 및 두께가 개구면 결합 마이크로스트립 패치 안테나의 특성에 미치는 영향 (Effects of the Dielectric Constant and Thickness of a Feed Substrate on the Characteristics of an Aperture Coupled Microstrip Patch Antenna)

  • 박혜린;구환모;김부균
    • 전자공학회논문지
    • /
    • 제51권7호
    • /
    • pp.49-59
    • /
    • 2014
  • 개구면 결합 마이크로스트립 패치 안테나(aperture coupled microstrip patch antenna; ACMPA)의 급전 기판의 유전상수와 두께가 안테나 대역폭과 방사특성에 미치는 영향에 대하여 연구하였다. 급전 기판의 두께가 같은 여러 가지 유전상수의 급전기판을 가지는 ACMPA의 최적화된 반사손실 대역폭은 방사특성의 저하 없이 급전기판의 유전상수가 감소할수록 대역폭이 증가한다. MMIC(monolithic microwave integrated circuit)와 집적화가 가능한 높은 유전상수(${\epsilon}_r=10$)를 가지는 급전 기판을 사용한 ACMPA의 최적화된 반사손실 대역폭은 방사특성의 저하 없이 급전 기판의 두께가 감소할수록 대역폭이 증가한다. 따라서 ACMPA는 MMIC와 집적화하기에 좋은 구조를 가진 패치 안테나이다.

Evaluation of Dual-channel Compound Method for EBT3 Film Dosimetry

  • Kang, Sang-Won;Chung, Jin-Beom;Kim, Kyeong-Hyeon;Eom, Keun-Yong;Song, Changhoon;Lee, Jeong-Woo;Cho, Woong;Suh, Tae Suk
    • 한국의학물리학회지:의학물리
    • /
    • 제28권1호
    • /
    • pp.16-21
    • /
    • 2017
  • This study assessed the feasibility of a dual-channel (DC) compound method for film dosimetry. The red channel (RC) is usually used to ensure dosimetric quality using a conventional fraction dose because the RC is more accurate at low doses within 3 Gy than is the green channel (GC). However, the RC is prone to rapid degradation of sensitivity at high doses, while degradation of the GC is slow. In this study, the DC compound method combining the RC and GC was explored as a means of providing accurate film dosimetry for high doses. The DC compound method was evaluated at various dose distributions using EBT3 film inserted in a solid-water phantom. Measurements with $10{\times}20cm^2$ radiation field and $60^{\circ}$ dynamic-wedge were done. Dose distributions acquired using the RC and GC were analyzed with root-mean-squares-error (RMSE) and gamma analyses. The DC compound method was used based on the RC after correcting the GC for high doses in the gamma analysis. The RC and GC produced comparatively more accurate RMSE values for low and high doses, respectively. Gamma passing rates with an acceptance criterion of 3%/3 mm revealed that the RC provided rapid reduction in the high dose region, while the GC displayed a gradual decrease. In the whole dose range, the DC compound method had the highest agreement (93%) compared with single channel method using either the RC (80%) or GC (85%). The findings indicate that the use of DC compound method is more appropriate in dosimetric quality assurance for radiotherapy using high doses.