• 제목/요약/키워드: Radiation contamination

검색결과 245건 처리시간 0.029초

Iodine-131 체내오염 사고에 대한 항갑상선제의 효과 (Effects of Antithyroid Drugs on Accidentally Internal Contamination of Iodine-131)

  • 정인용;김태환;진수일;윤택구
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제11권1호
    • /
    • pp.63-69
    • /
    • 1988
  • In case of occuring the atomic energy accidents the proper medical treatments should be necessary. As the aim of the basic data for protective actions, the present studies were carried out to evaluate the decontamination of radioiodine by the administration of the antithyroid drugs (KI, NaI) and isotonic saline. Some recommended methods of decorporating radioiodine were investigated using 450, NIH-GP mice, each injected intraperitoneally with $1{\mu}Ci$ of $NaI^{131}$ as the internal contamination and treated with 2mg/0.2ml-saline of NaI and 2.6mg/0.2ml-saline of KI as the antithyroid drugs. Accordingly, effects of antithyroid drugs for internal contamination were: 1. Administration of NaI and KI caused to rapidly excrete internal radioiodine as the antithyroid drugs and decrease in whole body retention was reduced than in the saline group. 2. After internal contamination NaI and KI were to be administered for radioprotective effects as quickly as possible. 3. Decrease in body-retention made temporary shifts with enough fluids (water), however, as far as radioprotective effects is concerned, saline was not more significant than in the other group (NaI and KI). 4. Regarding to thyroid protective effects NaI, KI and saline were significant in effectively order.

  • PDF

배관 내부 방사능 오염도 측정용 ZnS(Ag)/BC-408 phoswich 검출기 개발 (Development of the ZnS(Ag)/BC-408 phoswich detector for monitoring radioactive contamination inside pipes)

  • 김계홍;박찬희;정종헌;이근우;서범경
    • Journal of Radiation Protection and Research
    • /
    • 제31권3호
    • /
    • pp.123-128
    • /
    • 2006
  • 원자력 시설의 해체 시 발생되는 다양한 종류의 폐기물 중에서 배관 내부의 알파/베타선 오염 특성을 직접 평가하기 위해서는 소형의 방사선 검출 시스템이 요구된다. 본 연구에서는 배관 내부의 방사능 오염도를 직접 측정할 수 있는 장비 개발의 일환으로서 기존의 phoswich 검출기와 그 형태가 다른 ZnS(Ag)/플라스틱섬광체 조합의 알파/베타선 동시측정용 phoswich 검출기를 고안하였으며 섬광체 크기 및 검출 시스템의 최적 요건을 실험적으로 확인하고 알파/베타선 신호 분리도를 평가하였다. 그 결과 배관 내부의 오염도 측정에 적합한 phoswich 검출기의 최적 요건 및 배관 내부의 적용 가능성을 확인하였다.

수중 방사선 모니터링 시스템의 성능평가를 위한 수중 내 최소검출가능농도 산출 (Evaluation of Minimum Detectable Activity for Underwater Radiation Monitoring System)

  • 박장근;정성희;오대민;문진호
    • 방사선산업학회지
    • /
    • 제17권3호
    • /
    • pp.219-224
    • /
    • 2023
  • A high-efficiency underwater radiation monitoring system, HydroGamma, has been developed for detecting 137Cs and 131I in the event of waterborne radiation contamination. The system consists of a 3-inch NaI (Tl) detector, solar panels for power supply, data acquisition and transmission modules, and batteries. HydroGamma also includes a 40K calibration source for remote performance evaluation and energy calibration. In this study, some simulations and experiments were carried out to evaluate the minimum detectable activities (MDA) of HydroGamma. We installed the HydroGamma at Tapjeongho Lake in Nonsan-si and acquired background data since MDA is calculated based on the experimental background data. The results show that the minimum detectable activities for 137Cs and 131I were 1.78Bq L-1 and 1.81Bq L-1, respectively even though the gamma rays emitted from 40K(1,460 keV) affect the minimum detectable activities for them.

6MV 전자 선형 가속기 광자선의 전자오염 (Contamination of the 6MV Linear Accelerator Photon Beam by Electrons)

  • 유명진;김동원;정운혁
    • Journal of Radiation Protection and Research
    • /
    • 제13권1호
    • /
    • pp.21-30
    • /
    • 1988
  • 부산의대 부속 병원의 전자선형가속기 (Mevatron 67) 장치를 이용 하여 표면선량의 원인이 되는 광자선의 전자오염에 대한 연구를 하였다. 표면선량은 조사야의 크기에 따라 증가하는 경향을 나타내었다. 빔내에 트레이를 설치했을 때와 트레이를 제거했을때 표면선량의 변화와 전자오염정도를 관찰하였다. 전자오염을 감소시키기 위해서 구리 필터를 트레이 밑에 부착하여 그 효과를 분석하였다. 아울러 거리를 변화 시켜가며 선량의 변화를 관찰하여 최대의 피부보호효과를 유지할 수 있는 최적의 SSD와 TSD를 구하였다. 이런 모든 결과들은 방사선 치료 환자의 피부보호에 이용될 것이다.

  • PDF

병원 화장실의 방사성 오염에 관한 연구 (A Study of Radioactive Contamination in Hospital Toilet)

  • 김기진;김가중
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.241-246
    • /
    • 2015
  • Generally a patient who was injected radiopharmaceuticals for nuclear medicine examination is not an object of isolation. Therefore, when the patient uses toilet, we expect surface contamination of a toilet by radioisotope. The measured value is $25.69Bq/cm^2$(a restroom near admission and administration), $19.39Bq/cm^2$(a toilet near department of radiology). The study shows that 9 of 24 locations in controlled area exceed over surface contamination limit. From now on, we should find source of contamination through measurement radioactive nuclide to apply radiation safety management.

표면방사선 오염도 측정용 자동 스미어장치의 개발 (Development of Automatic Smear Equipment for Measuring Surface Radioactivity Contamination)

  • 탁한호;강신출
    • 한국산업정보학회논문지
    • /
    • 제16권4호
    • /
    • pp.37-44
    • /
    • 2011
  • 본 논문은 원자력시설내의 방사성 표면오염을 측정평가하기 위한 표변오염도 시료채취용 자동화 시료채취기 개발에 있다. 시료채취를 위한 간접법은 사람에 의한 수동적인 시료 채취방법으로서 시료를 채취하는 사람에 따라 문지르는 횟수 강도 및 면적이 다르다. 이로 인하여 표면오염도 측정치의 정확도가 저하되고 시료 채취시마다 측정치의 오차가 많이 발생한다. 개발된 장치에 의한 방법은 기존방법에 의한 표면오염도의 측정치보다 smear paper의 방사성 시료가 균일하게 채취됨을 확인하였으며, 향후 표면오염도의 평가시 측정자료의 일관성을 확보하게 되었다.

Gas ebullition associated with biological processes in radioactively contaminated reservoirs could lead to airborne radioactive contamination

  • E.A. Pryakhin;Yu.G. Mokrov;A.V. Trapeznikov;N.I. Atamanyuk;S.S. Andreyev;A.A. Peretykin;K. Yu. Mokrov;M.A. Semenov;A.V. Akleyev
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4204-4212
    • /
    • 2023
  • Background: Storage reservoirs of radioactive waste could be the source of atmospheric pollution due to the efflux of aqueous aerosol from their water areas. The main mechanism of formation of aqueous aerosols is the collapse of gas bubbles at the water surface. In this paper, we discuss the potential influence of biological factors on gas ebullition in the water areas of the radioactively contaminated industrial reservoirs R-9 (Lake Karachay) and R-4 (Metlinsky pond) of the Mayak PA. The emission of the released non-dissolved gases captured with gas traps in reservoir R-9 was (88-290) ml/m2 per day (2015) and in reservoir R-4 (270-460) ml/m2 per day (2016). The analysis of gas composition in reservoir R-4 (60% methane, 35% nitrogen, 2.4% oxygen, 1.5% carbon dioxide) confirms their biological origin. It is associated with the processes of organic matter destruction in bottom sediments. The major source of organic matter in bottom sediments is the dying phytoplankton developing in these reservoirs. Conclusion: The obtained results form the basis to set a task to quantify the relationship between the phytoplankton development, gases ebullition and radioactive atmosphere contamination.

뇨시료 전베타 분석법을 이용한 동위원소 생산시설 종사자 내부오염 스크리닝 및 감시절차 개발 (Gross Beta Screening and Monitoring Procedure using Urine Bioassay for Radiation Workers of Radioisotope Production Facilities)

  • 윤석원;김미령;박세영;박민정;유재룡;장한기;하위호
    • Journal of Radiation Protection and Research
    • /
    • 제38권2호
    • /
    • pp.52-59
    • /
    • 2013
  • 전베타 방사능 분석법을 이용한 내부오염 스크리닝법을 검증하였고 실제 의료용 동위원소 생산시설 종사자 내부오염을 판단하는데 적용하였다. 종사자의 작업 종료 후 첫 번째로 채취된 뇨시료(spot 시료)와 24시간 동안 취합된 뇨시료(24 h 시료)를 채취하여 측정하였다. 특정 종사자의 경우를 제외하고 대부분의 측정결과는 일반인 체내 기저준위인 100 Bq $kg^{-1}$을 기준으로 22% 이내로 변동폭이 작았다. 측정결과 작업종료 후 수 시간 이내 종사자 뇨시료의 전베타 농도가 전반적으로 35% 이상 상승하는 경향이 있었다. 또한 스크리닝 결과와 작업일지를 바탕으로 작업장내부 구조상 오염을 유발하는 요인을 추정 할 수 있었으며 추가 세부 핵종별 분석법을 바탕으로 내부피폭선량을 평가해야 할 것으로 판단되었다. 한편 사업장에서 신속히 적용 가능한 내부오염평가 절차를 수립하였다.

방류수의 방사능 오염 측정을 위한 배열형 SiPM 기반 방사선 검출 센서 제작 (Development of Radiation Sensor Based on Array SiPM for Measurement of Radioactive Contamination in Effluent)

  • 김정호;박혜민;주관식
    • 센서학회지
    • /
    • 제27권4호
    • /
    • pp.232-236
    • /
    • 2018
  • A radiation detection sensor was developed and characterized by combining three types of CsI(Tl) scintillators and an array-type SiPM to detect the radioactive contamination of discharged water in real time. The characterization results showed that type 3 exhibited the most desirable characteristics in response linearity (R-square: 0.97889) according to detection sensitivity and incident radiation dose. Furthermore, in terms of spectral characteristics, type 3 exhibited 16.54% at 0.356 MeV (the emission gamma ray energy of $^{133}Ba$), 10.28% at 0.511 MeV (the emission gamma ray energy of $^{22}Na$), 9.68% at 0.356 MeV (the emission gamma ray energy of $^{137}Cs$), and 2.55% and 4.80% at 1.173 MeV and 1.332 MeV (the emission gamma ray energies of $^{60}Co$), respectively. These measurements confirmed the good energy characteristics. The results were used to evaluate the spectral characteristics and energy linearity in a mixed source using type 3 with the best detection characteristics. It was confirmed that the gamma ray peaks of $^{133}Ba$, $^{22}Na$, $^{137}Cs$, and $^{60}Co$ were well resolved. Moreover, it was confirmed that R-square, which is an indicator of energy linearity, was 0.99986. This indicates a good linearity characteristic. Based on this study, further commercialization studies will contribute to measurements in real time and to the management of the contamination caused by radioactive wastewater or radioactive material leakage, which originate from facilities that use radioactive isotopes or care facilities.

동종조직에서의 방사선 멸균효과에 대한 연구 (THE EFFECT OF STERILIZATION OF GAMMA IRRADIATION ON ALLOGENEIC TISSUE MATERIALS)

  • 이은영;김성진;박우윤;김경원;엄인웅;류주연
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권6호
    • /
    • pp.523-527
    • /
    • 2005
  • Allograft donations are commonly found to be contaminated. The most of tissue banks has promoted the use of ionizing radiation for the sterilization of biological tissues. The potential for transmission of human infectious diseases and contamination of microorganism has created serious concern for the continued clinical use of hard and soft-tissue allografts. Tissue banks have employed 15-25kGy for sterilization of hard and tendon allografts, which, according to the national standards, approaches the level at which the tissue quality is adversely affected for transplantation. The donations of allogeneic tissues to the Korea Tissue Bank over a 2-year period were reviewed, and the incidence and bacteriology of contamination were detailed. Clinical outcomes were determined for donors who had positive cultures at the time of retrieval and during the processing and they were compared with those of post sterilization. After exposure of the frozen block bone to 25kGy and the processed tissues to 15kGy of gamma irradiation, the authors were able to demonstrate complete inactivation of the bacteria. The aim of this study was to obtain the effects of gamma irradiation and the irradiation dose according to the type of tissue, through conventional microbiologic test without on influence of biocompatibility in allografts. The contamination rate after the final irradiation sterilization is 0% in the processed allografts. This may be due to the fact that the gamma radiation and processing steps are effective to control contamination.