• Title/Summary/Keyword: Radiation Source

Search Result 1,436, Processing Time 0.029 seconds

Long-term Radiation Dose Reduction Plan of KHNP

  • Kim, Saeng-Ki;Shin, Sang-Woon;Lim, Byoung-Chan
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.2
    • /
    • pp.137-143
    • /
    • 2003
  • Annual radiation dose limit to radiation worker was substantially lowered in Korea by the adoption of 1990 recommendations of the International Commission on Radiation Protection (ICRP 60) in its legislation. On the other hand, radiation management environment in nuclear power plants is getting more worse because of the accumulation of radiation sources inside the system and the frequent need for maintenance according as the operation years of nuclear power plants increase. Therefore, Korea Hydro & Nuclear power Co., Ltd. (KHNP) has established a long-term 10 years plan from 2001 to 2010 for the reduction of radiation dose to workers. The plan is aimed for the reduction of annual dose per unit averaged over 5 years from 0.9 man-Sv in 2001 to 0.75 man-Sv in 2010 by radiation source reduction, equipment/tool improvement or new equipment development for easy maintenance, and the improvement of administration and system.

Radiation Characteristics of Microstrip Antenna on the Cylindrical Bianisotropic Substrates Loaded bianisotropic superstrate

  • Yoon, Joong-Han;Lee, Sang-Mok;Park, Byung-Ha
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.885-888
    • /
    • 1999
  • Radiation characteristics of axial elementary current source on the cylindrical bianisotropic substrateloaded with bianisotropic superstrate layer are presented. The effects of bianisotropic superstrate cover on the radiation problems of a microstrip antenna are studied. This investigation is performed by using the Green function formulation in the spectral domain. Numerical results for the radiation pattern of the bianisotropic superstrate-loaded microstrip antenna is analyzed.

  • PDF

Evaluation of Factors Used in AAPM TG-43 Formalism Using Segmented Sources Integration Method and Monte Carlo Simulation: Implementation of microSelectron HDR Ir-192 Source (미소선원 적분법과 몬테칼로 방법을 이용한 AAPM TG-43 선량계산 인자 평가: microSelectron HDR Ir-192 선원에 대한 적용)

  • Ahn, Woo-Sang;Jang, Won-Woo;Park, Sung-Ho;Jung, Sang-Hoon;Cho, Woon-Kap;Kim, Young-Seok;Ahn, Seung-Do
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.190-197
    • /
    • 2011
  • Currently, the dose distribution calculation used by commercial treatment planning systems (TPSs) for high-dose rate (HDR) brachytherapy is derived from point and line source approximation method recommended by AAPM Task Group 43 (TG-43). However, the study of Monte Carlo (MC) simulation is required in order to assess the accuracy of dose calculation around three-dimensional Ir-192 source. In this study, geometry factor was calculated using segmented sources integration method by dividing microSelectron HDR Ir-192 source into smaller parts. The Monte Carlo code (MCNPX 2.5.0) was used to calculate the dose rate $\dot{D}(r,\theta)$ at a point ($r,\theta$) away from a HDR Ir-192 source in spherical water phantom with 30 cm diameter. Finally, anisotropy function and radial dose function were calculated from obtained results. The obtained geometry factor was compared with that calculated from line source approximation. Similarly, obtained anisotropy function and radial dose function were compared with those derived from MCPT results by Williamson. The geometry factor calculated from segmented sources integration method and line source approximation was within 0.2% for $r{\geq}0.5$ cm and 1.33% for r=0.1 cm, respectively. The relative-root mean square error (R-RMSE) of anisotropy function obtained by this study and Williamson was 2.33% for r=0.25 cm and within 1% for r>0.5 cm, respectively. The R-RMSE of radial dose function was 0.46% at radial distance from 0.1 to 14.0 cm. The geometry factor acquired from segmented sources integration method and line source approximation was in good agreement for $r{\geq}0.1$ cm. However, application of segmented sources integration method seems to be valid, since this method using three-dimensional Ir-192 source provides more realistic geometry factor. The anisotropy function and radial dose function estimated from MCNPX in this study and MCPT by Williamson are in good agreement within uncertainty of Monte Carlo codes except at radial distance of r=0.25 cm. It is expected that Monte Carlo code used in this study could be applied to other sources utilized for brachytherapy.

Evaluation of Source Identification Method Based on Energy-Weighting Level with Portal Monitoring System Using Plastic Scintillator

  • Lee, Hyun Cheol;Koo, Bon Tack;Choi, Chang Il;Park, Chang Su;Kwon, Jeongwan;Kim, Hong-Suk;Chung, Heejun;Min, Chul Hee
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.3
    • /
    • pp.117-129
    • /
    • 2020
  • Background: Radiation portal monitors (RPMs) involving plastic scintillators installed at the border inspection sites can detect illicit trafficking of radioactive sources in cargo containers within seconds. However, RPMs may generate false alarms because of the naturally occurring radioactive materials. To manage these false alarms, we previously suggested an energy-weighted algorithm that emphasizes the Compton-edge area as an outstanding peak. This study intends to evaluate the identification of radioactive sources using an improved energy-weighted algorithm. Materials and Methods: The algorithm was modified by increasing the energy weighting factor, and different peak combinations of the energy-weighted spectra were tested for source identification. A commercialized RPM system was used to measure the energy-weighted spectra. The RPM comprised two large plastic scintillators with dimensions of 174 × 29 × 7 ㎤ facing each other at a distance of 4.6 m. In addition, the in-house-fabricated signal processing boards were connected to collect the signal converted into a spectrum. Further, the spectra from eight radioactive sources, including special nuclear materials (SNMs), which were set in motion using a linear motion system (LMS) and a cargo truck, were estimated to identify the source identification rate. Results and Discussion: Each energy-weighted spectrum exhibited a specific peak location, although high statistical fluctuation errors could be observed in the spectrum with the increasing source speed. In particular, 137Cs and 60Co in motion were identified completely (100%) at speeds of 5 and 10 km/hr. Further, SNMs, which trigger the RPM alarm, were identified approximately 80% of the time at both the aforementioned speeds. Conclusion: Using the modified energy-weighted algorithm, several characteristics of the energy weighted spectra could be observed when the used sources were in motion and when the geometric efficiency was low. In particular, the discrimination between 60Co and 40K, which triggers false alarms at the primary inspection sites, can be improved using the proposed algorithm.

A Study on Radiation Characteristics of Noise Sources for Korean Train Express (한국형 고속철도의 소음 방사특성에 관한 연구)

  • Kim, Jae-Chul;Koo, Dong-Heo;Moon, Kyeong-Ho;Lee, Jae-Eung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.323-327
    • /
    • 2002
  • In order to control the railway noise, the radiation characteristic of the noise during the train passage should be analyzed. Generally, the major noise sources for Korean Train Express are the rolling noise and power unit noise up to 300km/h. In this paper, we describe on a train model that is considered to be a row of point sources to calculate the radiation characteristic. The calculation results are compared with short distance measurement. It is shown that the radiation characteristic of the rolling noise is dipole type. The noise generated by the power unit is radiated as the cosine type. The noise level at an observer is increased in the direction of motion and reduced in the direction opposite to the motion with increasing of the train speed. The calculation results including the moving effect of the noise source at 300km/h show in good agreement.

  • PDF

A Change in the Temperature and Infrared Radiation as a Variation of Irradiance (복사조도의 번동에 따른 온도 및 적외선복사량의 변화)

  • Han, Jong-Sung;Kim, Gi-Hoon;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.28-34
    • /
    • 2005
  • Thermal reactions by infrared radiation brings about physical damage by temperature rise process or temperature drop process of the material. In this study, a measuring system was set up to measure the temperature rise of each sample by infrared radiation from light source. And the temperature rise of the samples and amount of infrared radiation by various light source were measured with varying irradiance. On the basis of the result from the test, we analyzed a functional relation between infrared and infrared radiation.

Rationale and Definition of The Criteria of The Efficiency of The Biological Activity of Optical Radiation on Animal Organism.

  • Chervinsky, Leonid S.
    • The Korean Journal of Food & Health Convergence
    • /
    • v.4 no.3
    • /
    • pp.1-5
    • /
    • 2018
  • In today's technological development of human society more and more influence on the lives of biological organisms different electromagnetic radiation. Therefore, the study and analysis of the mechanisms of their effects is an urgent task. The purpose of research - the study of the primary mechanisms of interaction of photons of optical radiation with the structures of biological objects, using the laws of quantum mechanics and biophysics. Photobiological basis of the mechanism of action of EMR optical range is the energy absorption of light quanta (photons) by atoms and molecules of biological structures (law Grotgus-Draper), which resulted in the formation of electronically excited states of these molecules with the transfer of photon energy (internal photoeffect). This is accompanied by electrolytic dissociation and ionization of biological molecules. The degree of manifestation of photobiological effects in the body depends on the intensity of the optical radiation, which is inversely proportional to the square of the distance from the source to the irradiated surface. Accordingly, in practice, determine not the intensity and irradiation dose at a certain distance from the source of exposure by the exposure time.

Development of a diverging collimator for environmental radiation monitoring in the industrial fields

  • Dong-Hee Han;Seung-Jae Lee;Jang-Oh Kim ;Da-Eun Kwon;Hak-Jae Lee ;Cheol-Ha Baek
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4679-4683
    • /
    • 2022
  • Environmental radiation monitoring is required to protect from the effects of radiation in industrial fields such as nuclear power plant (NPP) monitoring, and various gamma camera systems are being developed. The purpose of this study is to optimize parameters of a diverging collimator composed of pure tungsten for compactness and lightness through Monte Carlo simulation. We conducted the performance evaluation based on spatial resolution and signal-to-noise ratio for point source and obtained gamma images and profiles. As a result, optimization was determined at a collimator height of 60.0 mm, a hole size of 1.5 mm, and a septal thickness of 1.0 mm. Also, the full-width-at-half-maximum was 3.5 mm and the signal-to-noise ratio was 53.5. This study proposes a compact 45° diverging collimator structure that can quickly and accurately identify the location of the source for radiation monitoring.

Gas ebullition associated with biological processes in radioactively contaminated reservoirs could lead to airborne radioactive contamination

  • E.A. Pryakhin;Yu.G. Mokrov;A.V. Trapeznikov;N.I. Atamanyuk;S.S. Andreyev;A.A. Peretykin;K. Yu. Mokrov;M.A. Semenov;A.V. Akleyev
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4204-4212
    • /
    • 2023
  • Background: Storage reservoirs of radioactive waste could be the source of atmospheric pollution due to the efflux of aqueous aerosol from their water areas. The main mechanism of formation of aqueous aerosols is the collapse of gas bubbles at the water surface. In this paper, we discuss the potential influence of biological factors on gas ebullition in the water areas of the radioactively contaminated industrial reservoirs R-9 (Lake Karachay) and R-4 (Metlinsky pond) of the Mayak PA. The emission of the released non-dissolved gases captured with gas traps in reservoir R-9 was (88-290) ml/m2 per day (2015) and in reservoir R-4 (270-460) ml/m2 per day (2016). The analysis of gas composition in reservoir R-4 (60% methane, 35% nitrogen, 2.4% oxygen, 1.5% carbon dioxide) confirms their biological origin. It is associated with the processes of organic matter destruction in bottom sediments. The major source of organic matter in bottom sediments is the dying phytoplankton developing in these reservoirs. Conclusion: The obtained results form the basis to set a task to quantify the relationship between the phytoplankton development, gases ebullition and radioactive atmosphere contamination.

Development of Three-Dimensional Gamma-ray Camera (방사선원 3차원 위치탐지를 위한 방사선 영상장치 개발)

  • Lee, Nam-Ho;Hwang, Young-Gwan;Park, Soon-Yong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.2
    • /
    • pp.486-492
    • /
    • 2015
  • Radiation source imaging system is essential for protecting of radiation leakage accidents and minimizing damages from the radioactive materials, and is expected to play an important role in the nuclear plant decommissioning area. In this study, the stereoscopic camera principle was applied to develop a new radiation imaging device technology that can extract the radiation three-dimensional position information. This radiation three-dimensional imaging device (K3-RIS) was designed as a compact structure consisting of a radiation sensor, a CCD camera, and a pan-tilt only. It features the acquisition of stereoscopic radiation images by position change control, high-resolution detection by continuous scan mode control, and stereoscopic image signal processing. The performance analysis test of K3-RIS was conducted for a gamma-ray source(Cs-137) in radiation calibration facility. The test result showed that a performance error with less than 3% regardless of distances of the objects.