• 제목/요약/키워드: Radiation Shielding Materials

검색결과 229건 처리시간 0.024초

The radiation shielding proficiency and hyperspectral-based spatial distribution of lateritic terrain mapping in Irikkur block, Kannur, Kerala

  • S. Arivazhagan;K.A. Naseer;K.A. Mahmoud;N.K. Libeesh;K.V. Arun Kumar;K.ChV. Naga Kumar;M.I. Sayyed;Mohammed S. Alqahtani;E. El Shiekh;Mayeen Uddin Khandaker
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3268-3276
    • /
    • 2023
  • The practice of identifying the potential zones for mineral exploration in a speedy and low-cost method includes the use of satellite imagery analysis as a part of remote sensing techniques. It is challenging to explore the iron mineralization of a region through conventional methods which are a time-consuming process. The current study utilizes the Hyperion satellite imagery for mapping the iron mineralization and associated geological features in the Irikkur region, Kannur, Kerala. Along with the remote sensing results, the field study and laboratory-based analysis were conducted to retrieve the ground truth point and geochemical proportion to verify the iron ore mineralization. The MC simulation showed for shielding properties indicate an increase in the linear attenuation coefficient with raising the Fe2O3+SiO2 concentrations in the investigated rocks where it is varied at 0.662 MeV in the range 0.190 cm-1 - 0.222 cm-1 with rising the Fe2O3+SiO2 content from 57.86 wt% to 71.15 wt%. The analysis also revealed that when the γ-ray energy increased from 0.221 MeV to 2.506 MeV, sample 1 had the largest linear attenuation coefficient, ranging from 9.33 cm1 to 0.12 cm-1. Charnockite rocks were found to have exceptional shielding qualities, making them an excellent natural choice for radiation shielding applications.

3D 프린팅용 금속 입자 필라멘트의 물성 및 차폐 능력 평가 (Evaluation of Metal Composite Filaments for 3D Printing)

  • 박기석;최우전;김동현
    • 한국방사선학회논문지
    • /
    • 제15권5호
    • /
    • pp.697-704
    • /
    • 2021
  • 3D 프린팅 FDM방식의 재료인 필라멘트 중 차폐성능을 지닌 필라멘트는 국내에 판매되지 않고 있으며 관련 연구도 미비하다. 이에 본 연구는 금속 입자가 함유된 필라멘트의 물성과 방사선의 차폐능력을 평가하여 3D 프린트를 이용한 방사선 차폐체 개발의 기초자료를 제공하고자 한다. 금속입자 강화재가 함유된 금속 필라멘트 5가지를 선정 후 ASTM의 평가방법을 이용하여 인장강도, 밀도, XRD, 무게측정 등 물성을 평가하고 방사선 차폐능력을 알아보기 위하여 한국산업표준의 방호용구류 시험방법에 따라서 방사선 차폐율을 구하였다. 인장강도는 PLA + SS가 가장 높았고 ABS + W가 가장 낮았으며 밀도는 ABS + W 가 3.13 g/cm3으로 가장 높게 나타났다. XRD결과 시편의 표면의 입자의 XRD peak 패턴이 각 입자 강화재 분말 금속의 패턴과 일치함을 확인 할 수 있어 프린트된 시편이 분말금속이 함유 되었음을 확인하였다. 3D 프린트 복합 필라멘트별 차폐효과는 ABS + W, ABS + Bi, PLA + SS, PLA + Cu, PLA + Al의 순서로 실효원자번호와 밀도에 비례하여 차폐율이 높게 나타났다. 본 연구에서는 강화재로 금속 분말이 함유된 금속입자 복합 필라멘트는 방사선의 차폐능력을 가지는 것이 확인되었으며 향후 방사선 차폐용 필라멘트의 사용가능성을 확인하였다.

몬테카를로 방사선 수송 모델을 활용한 우주방사선 차폐체 설계 관련 선행연구 (Preliminary Study of Cosmic-ray Shielding Material Design Using Monte-Carlo Radiation Transport Code)

  • 강창우;김영찬
    • 한국방사선학회논문지
    • /
    • 제16권5호
    • /
    • pp.527-536
    • /
    • 2022
  • 본 연구는 우주방사선 차폐물질 설계를 위한 선행연구 차원에서 우주방사선에 대한 물질별 방사선 차폐특성을 분석하였다. 특히 EMP 및 방사선 차폐에 효과가 있다고 알려진 경량 연자성 복합소재에 대한 우주방사선 차폐물질 활용 가능성을 확인하고자 하였다. 이를 위해 Monte Carlo N-Particle(MCNP) 모델링 기법과 열중성자 차폐실험을 수행하였으며, MCNP의 우주방사선 모델인 Skymap.dat를 활용하였다. 연구결과 폴리에틸렌, 붕소폴리에틸렌, 탄소나노튜브 등 탄소와 수소를 함유한 물질의 경우 증발 중성자 에너지 영역 대 이하의 중성자 감소에 효과적인 것으로 나타났으며 SS316, 경량 연자성 물질 등 철을 함유한 물질은 캐스케이드 중성자 차폐성능이 뛰어난 것을 확인할 수 있었다. 특히 경량 연자성 물질의 경우 붕소를 함유하고 있어 저속중성자 영역의 중성자 감소에도 효과적인 것으로 나타났으며, 향후 탄소 및 수소 등 탄성산란 물질을 보강한다면 우주방사선 중성자 전 영역에서 유의미한 차폐효과를 보여줄 것으로 기대된다.

The radiation shielding competence and imaging spectroscopic based studies of Iron ore region of Kozhikode district, Kerala

  • S. Arivazhagan;K.A. Naseer;K.A. Mahmoud;S.A. Bassam;P.N. Naseef Mohammed;N.K. Libeesh;A.S. Sachana;M.I. Sayyed;Mohammed S. Alqahtani;E. El Shiekh;Mayeen Uddin Khandaker
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2380-2387
    • /
    • 2023
  • Hyperspectral data and its ability to explore the minerals and their associated rocks have a remarkable application in mineral exploration and lithological characterization. The present study aims to explore the radiation shielding aspects of the iron ore in Kerala with the aid of the Hyperion hyperspectral dataset. The reflectance-spectra obtained from the laboratory conditions as well as from the image show various absorptions. The results from the spectra are validated with geochemical data and GPS points. The Monte Carlo simulation employed to evaluate the radiation shielding ability. Raising the oxygen ions caused a noteworthy decrease in the µ values of the studied rocks which is accompanied by an increase in Δ0.5 and Δeq values. The Δ0.5 and Δeq values increased by factors of approximately 77 % with raising the oxygen ions between 44.32 and 47.57 wt.%. The µ values varies with the oxygen concentrations, where the µ values decreased from 2.531 to 0.925 cm-1 (at 0.059 MeV), from 0.381to 0.215 cm-1 (at 0.662 MeV), and from 0.279 to 0.158 cm-1 (at 1.25 MeV) with raising the oxygen ions from 44.32 to 47.43 wt.%.

6 MeV 전자선 치료 시 차폐물질로서 알루미늄, 구리, 납 (Aluminum, Copper and Lead as Shielding Materials in 6 MeV Electron Therapy)

  • 이승훈;차석용;이선영
    • 한국콘텐츠학회논문지
    • /
    • 제14권2호
    • /
    • pp.457-466
    • /
    • 2014
  • 고 에너지 전자선 치료에 있어서 차폐물질은 종양조직 외 정상조직이나 주요장기를 보호하기 위해 사용된다. 하지만 이러한 물질에서 발생되어지는 산란선은 심부선량에 영향을 줄 수 있으며, 물질원자번호에 따라 다르게 나타난다. 이에 차폐물질로써 사용가능한 알루미늄, 구리, 납 등의 다양한 원자번호 물질을 전하 감약율 95% 되는 두께로 하여 측정과 MCNPX 모의계산으로 산란율을 비교분석하였다. 산란선 영향을 많이 받는 표면의 선량변화율은 최대 물질두께에서 +0.88%, 원자번호에서 +0.43%의 영향을 받으며, 전하 감약율 95% 되는 두께의 알루미늄, 구리, 납 물질은 측정에서 +19.70%, +15.20%, +12.40% 계산에서 +25.00%, +15.10%, +13.70%를 보였다. 이로 인해 산란율은 물질두께가 원자번호보다 많은 영향을 주며, 산란전자가 광자보다 많은 기여를 하고 있음을 알 수 있었다. 이에 임상에서의 적절한 차폐물질은 두께영향 산란선이 적게 방출되는 고 원자번호물질이 적당하다고 사료된다.

Investigation of gamma radiation shielding capability of two clay materials

  • Olukotun, S.F.;Gbenu, S.T.;Ibitoye, F.I.;Oladejo, O.F.;Shittu, H.O.;Fasasi, M.K.;Balogun, F.A.
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.957-962
    • /
    • 2018
  • The gamma radiation shielding capability (GRSC) of two clay-materials (Ball clay and Kaolin)of Southwestern Nigeria ($7.49^{\circ}N$, $4.55^{\circ}E$) have been investigated by determine theoretically and experimentally the mass attenuation coefficient, ${\mu}/{\rho}(cm^2g^{-1})$ of the clay materials at photon energies of 609.31, 1120.29, 1173.20, 1238.11, 1332.50 and 1764.49 keV emitted from $^{214}Bi$ ore and $^{60}Co$ point source. The mass attenuation coefficients were theoretically evaluated using the elemental compositions of the clay-materials obtained by Particle-Induced X-ray Emission (PIXE) elemental analysis technique as input data for WinXCom software. While gamma ray transmission experiment using Hyper Pure Germanium (HPGe) spectrometer detector to experimentally determine the mass attenuation coefficients, ${\mu}/{\rho}(cm^2g^{-1})$ of the samples. The experimental results are in good agreement with the theoretical calculations of WinXCom software. Linear attenuation coefficient (${\mu}$), half value layer (HVL) and mean free path (MFP) were also evaluated using the obtained ${\mu}/{\rho}$ values for the investigated samples. The GRSC of the selected clay-materials have been compared with other studied shielding materials. The cognizance of various factors such as availability, thermo-chemical stability and water retaining ability by the clay-samples can be analyzed for efficacy of the material for their GRSC.

Personal Dosimeters Worn by Radiation Workers in Korea: Actual Condition and Consideration of Their Proper Application for Radiation Protection

  • Eunbi Noh;Dalnim Lee;Sunhoo Park;Songwon Seo
    • Journal of Radiation Protection and Research
    • /
    • 제48권3호
    • /
    • pp.162-166
    • /
    • 2023
  • Background: Assessment of the radiation doses to which workers are exposed can differ depending on the placement of dosimeters on the body. In addition, it is affected by whether the placement is under or over a shielding apron. This study aimed to evaluate the actual positioning of personal dosimeters on the body, with or without shielding aprons, among radiation workers in Korea. Materials and Methods: We analyzed the survey data, which included demographic characteristics, such as sex, age, occupation, work history, and placement of the personal dosimeter being worn, from a cohort study of Korean radiation workers. We assessed the use of personal dosimeters among workers, stratified by sex, age, working period, starting year of work, and occupation. Results and Discussion: Overall, high compliance (89.1% to 99.0%) with the wearing of dosimeters on the chest was observed regardless of workers' characteristics, such as age, sex, occupation, and work history. However, the placement of dosimeters, either under or over the shielding aprons, was inconsistent. Overall, 40.1% of workers wore dosimeters under their aprons, while the others wore dosimeters over their aprons. This inconsistency indicates that radiation doses are possibly measured differently under the same exposure conditions solely owing to variations in the placement of worn dosimeters. Conclusion: Although a lack of uniformity in dosimeter placement when wearing a shielding apron may not cause serious harm in radiation dose management for workers, the development of detailed guidelines for dosimeter placement may improve the accuracy of dose assessment.

방사선 조사선량이 수지계 중성자 차폐재의 역학적 성질에 미치는 영향 (Effects of Radiation Dose on Mechanical Properties of Resin-Type Neutron Shielding Materials)

  • 조수행;홍순석;김환영;도재범;노성기
    • 공업화학
    • /
    • 제8권1호
    • /
    • pp.92-98
    • /
    • 1997
  • 방사선 조사선량이 사용후 핵연료 수송용기 등에 사용되는 에폭시수지계 중성자 차폐재들의 인장강도, 압축강도, 굴곡강도, 비중, 무게 변화 및 수소함량 변화 등 역학적 성질에 미치는 영향을 검토하였다. 0.5MGy까지는 방사선 조사선량의 증가에 따라 KNS-115A, KNS-115B 및 KNS-115C(Kaeri Neutron Shield) 차폐재들의 인장강도, 압축강도 및 굴곡강도는 증가하는 경향을 나타냈으나, 0.5MGy 이상에서는 감소하는 경향을 나타내었다. 또한 조사선량의 증가에 따른 차폐재의 비중 및 무게는 크게 변하지 않는 것으로 나타났으나, 수소함량은 감소하는 경향을 나타내었다.

  • PDF

Shielding Evaluation and Activation Analysis of Facilities by Neutron Generator for the Development of 20 Feet Container Inspection System

  • Jin-Woo Lee;Dae-Sung Choi;Gyo-Seong Jeong
    • 방사선산업학회지
    • /
    • 제17권4호
    • /
    • pp.443-449
    • /
    • 2023
  • KAERI(Korea Atomic Energy Research Institute) is conducting research and development of large-scale radiation generators and the latest radiation measuring instruments. In particular, research and development of security screening equipment using an electron beam accelerator and a neutron generator is in progress recently. Globally, 20 ft containers are used to transport imports and exports, and electron beam accelerators are radiation sources to measure the shape of the material inside the container during customs inspections in each country. KAERI is developing a device that can use an electron beam accelerator and a neutron generator sequentially to grasp the shape of various materials as well as the location of the internal target material. In this study, when using the neutron generator, the radiation dose and the degree of activation by neutron for the facility and surrounding environment, facility equipment were simulated using MCNP and FISPACT code. As a result, the shielding structures inside and outside the radiation control area were satisfactory to the reference level established conservatively based on the Korean Nuclear Act.

Effect of the new photoatomic data library EPDL2017 to mass attenuation coefficient calculation of materials used in the nuclear medicine facilities using EpiXS software

  • Jecong, J.F.M.;Hila, F.C.;Balderas, C.V.;Guillermo, N.R.D.
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3440-3447
    • /
    • 2022
  • The accuracy of the photoatomic cross-section data is of great importance in the field of radiation protection, particularly in the characterization of radiation shielding materials. With the release of the latest and probably the most accurate photoatomic data library, EPDL2017, the need to re-evaluate all the existing and already established mass attenuation coefficients (MACs) of all radiation shielding materials arises. The MACs of several polymers, alloy-based, glasses, and building materials used in a nuclear medicine facility were investigated using the EPDL2017 library embedded in EpiXS software and were compared to MACs available in the literature. The relative differences between MACEpiXS and MACXCOM were negligible, ranging from 0.02% to 0.36% for most materials. However, for material like a glass comprising of elements Te and La evaluated near their corresponding K-edge energies, the relative differences in MACs increased up to 1.46%. On the other hand, a comparison with MACs calculated based on EPDL97 (a predecessor of EPDL2017) revealed as much as a 6.61% difference. Also, it would seem that the changes in MACs were more evident in the materials composed of high atomic number elements evaluated at x-ray energies compared to materials composed of low atomic number elements evaluated at gamma-ray energies.