• Title/Summary/Keyword: Radiation Over-exposure

Search Result 165, Processing Time 0.025 seconds

Sterilization Effect of Microbial Strains by using Non-ionizing Radiation (비전리방사선을 이용한 미생물 균주 멸균효과)

  • Jeong, Kyeonghwan;Seo, Jeongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.833-839
    • /
    • 2020
  • Globally, infection prevention and social awareness have been greatly changed by the severe acute respiratory syndrome coronavirus, and as a result, the infection control guidelines and procedures for patients with high exposure to hospital-acquired infection are further strengthened and management and monitoring are more thorough. In order to prevent infection, sterilization should be carried out with the highest priority, and we will find a sterilization method that is low in cost, easy to install, and easy to operate, to present appropriate sterilization effects. In this study, the UV sterilizer was used to contaminate the caries bacteria with an output of 4 W and irradiation time of 60, 150, and 300 sec, and the laser was irradiated with outputs of 0.8 and 1.5 W at wavelengths of 266 and 355 nm, respectively. Ultraviolet sterilizer showed safety in infection prevention at over 150 sec, and laser showed safety in prevention at 1.5 W, 0.8 W, and 266 nm. As a result, the higher the output and the wavelength closer to 253.7 nm, the better the sterilization effect.

Sun Burn Incidence and Knowledge of Greek Elementary and High School Children about Sun Protection

  • Saridi, Maria Ioannis;Toska, Aikaterini George;Rekleiti, Maria Dimitrios;Tsironi, Maria;Geitona, Maria;Souliotis, Kyriakos
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.4
    • /
    • pp.1529-1534
    • /
    • 2015
  • Introduction: Overexposure to sun radiation and particularly its accumulation during childhood and adolescence is a significant risk factor for skin cancer development. The sun burn is particularly important. Aim: To estimate sun burn incidence in young pupils in a coastal area of Greece. Materials and Methods: Two surveys were conducted in a school population in the same district in Greece, over different periods of time, in young people 9 to 18 years old (n=2 977). Anonymous questionnaires were completed. Levels of significance were two-tailed and statistical significance was set at p=0.05. SPSS 17.0 software was used for statistical analysis. Results: From the individual characteristics of the participants it was shown that the majority of them had dark hair and fair skin, whereas a significant percentage reported the existence of moles on face and their body (83.4% vs 68.1%). The sun burn incidence was high in adolescents and the younger pupils (41.9% vs 55.6%). The younger aged children who were living in an urban area had significantly higher rates of sun burn than those living in semi-urban areas (33.8% vs 24.8%, p=0.020). As far as the knowledge of pupils about the risks of sun radiation it was shown that the elementary school pupils had better knowledge than those at high school. Finally, those with better knowledge had the fewer sun burns (Mean 2.83 SD 0.87, p<0.001). Conclusions: The contribution of knowledge to the decrease of sun burn incidence is important as long as this is continuous. Therefore, the education should concern not only children but also teachers and parents in the context of continuous and systematic programs of health education.

Color stability of thermochromic pigment in maxillofacial silicone

  • Kantola, Rosita;Lassila, Lippo V.J.;Tolvanen, Mimmi;Valittu, Pekka K.
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.2
    • /
    • pp.75-83
    • /
    • 2013
  • PURPOSE. Maxillofacial silicone elastomer is usually colored intrinsically with color pigments to match skin colors. The purpose of this study was to investigate the color stability of a maxillofacial silicone elastomer, colored with a thermochromic, color changing pigment. MATERIALS AND METHODS. Disc-shaped maxillofacial silicone specimens were prepared and divided into 3 groups: a conventionally colored control group, one group additionally colored with 0.2 wt% thermochromic pigment, and one group with 0.6 wt% thermochromic pigment. Half of the surface of each specimen was covered with an aluminium foil. All of the specimens were exposed to UV radiation in 6 hour cycles over 46 days. In between the UV exposures, half of the specimens were stored in darkness, at room temperature, and the other half was stored in an incubator, at a humidity of 97% and a temperature of $+37^{\circ}C$. Color measurements were made with a spectrophotometer and registered according to the CIELAB $L^*a^*b^*$ color model system. The changes in $L^*$, $a^*$ and $b^*$ values during artificial aging were statistically analyzed by using paired samples t-test and repeated measures ANOVA. P-values <.05 were considered as statistically significant. RESULTS. The UV exposure resulted in visually noticeable and statistically significant color changes in the $L^*$, $a^*$ and $b^*$ values in both of the test groups containing thermochromic pigment. Storage in the incubator lead to statistically significant color changes in the $a^*$ and $b^*$ values of the specimens containing thermochromic pigment, compared to those stored at room temperature. CONCLUSION. The specimens containing thermochromic pigment were very sensitive to UV radiation, and the thermochromic pigment is not suitable, as such, to be used in maxillofacial prostheses.

Perceived Relevance of Educative Information on Public (Skin) Health: A Cross-sectional Questionnaire Survey

  • Haluza, Daniela;Cervinka, Renate
    • Journal of Preventive Medicine and Public Health
    • /
    • v.46 no.2
    • /
    • pp.82-88
    • /
    • 2013
  • Objectives: Unprotected leisure time exposure to ultraviolet radiation from the sun or artificial tanning beds is the most important environmental risk factor for melanoma, a malignant skin cancer with increasing incidences over the past decades. The aim of the present study was to assess the impact of skin health information provided by several sources and different publishing issues on knowledge, risk perception, and sun protective behavior of sunbathers. Methods: A cross-sectional questionnaire survey was conducted among Austrian residents (n=563) spending leisure time outdoors in August 2010. Results: Print media, television, and family were perceived as the most relevant sources of information on skin health, whereas the source physician was only ranked as fourth important source. Compared to other sources, information provided by doctors positively influenced participants' knowledge on skin risk and sun protective behavior resulting in higher scores in the knowledge test (p=0.009), higher risk perception (p<0.001), and more sun protection (p<0.001). Regarding gender differences, internet was more often used by males as health information source, whereas females were more familiar with printed information material in general. Conclusions: The results of this survey put emphasis on the demand for information provided by medical professionals in order to attain effective, long-lasting promotion of photoprotective habits.

Evidence for U.S. Preventive Services Task Force (USPSTF) Recommendations Against Routine Mammography for Females between 40-49 Years of Age

  • Karimi, Parisa;Shahrokni, Armin;Moradi, Sedighe
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.3
    • /
    • pp.2137-2139
    • /
    • 2013
  • Breast cancer is the most common cancer among females, worldwide, accounting for 22.9% of all cancers (excluding non-melanoma skin cancer) in females. Mammography is a sensitive (77-95%) and specific (94-97%) screening method for breast cancer. Previously, females between the 40-50 years old were recommended to have mammograms every one to two years. However, based on current evidence, in 2009, USPSTF recommended that the decision to start regular, biennial screening mammography for females younger than 50 years should be an individual decision and take patient context into account, including the patient's values regarding specific benefits and harms. This decision was based on findings regarding radiation exposure, false-positive and false-negative rates, over-diagnosis, and pain and psychological responses. The goal of this paper is to focus on evidence for updating the U.S. Preventive Services Task Force (USPSTF) recommendation against routine mammography for females between 40-49 years of age.

Aging and UV Irradiation Related Changes of Gene Expression in Primary Human Keratinocytes

  • Lee, Ok Joo;Lee, Sung-Young;Park, Jae-Bong;Lee, Jae-Yang;Kim, Jong-Il;Kim, Jaebong
    • Genomics & Informatics
    • /
    • v.3 no.2
    • /
    • pp.66-72
    • /
    • 2005
  • The epidermis is a physiological barrier to protect organisms against environment. During the aging process, skin tissues undergo various changes including morphological and functional changes. The transcriptional regulation of genes is part of cellular reaction of aging process. In order to examine the changes of gene expression during the aging process, we used the primary cell culture system of human keratinocytes. Since UV radiation is the most important environmental skin aggressor, causing skin cancer and other problems including premature skin aging, we examined the changes of gene expression in human keratinocytes after UV irradiation using oligonucleotide microarray containing over 10,000 genes. We also compared the gene expression patterns of the senescent and UV treated cells. Expression of the variety of genes related to transcription factors, cell cycle regulation, immune response was altered in human keratinocytes. Some of down-regulated genes are represented in both senescent and UV treated cells. The results may provide a new view of gene expression following UVB exposure and aging process in human keratinocytes.

Endovascular embolization of persistent liver injuries not responding to conservative management: a narrative review

  • Simon Roh
    • Journal of Trauma and Injury
    • /
    • v.36 no.3
    • /
    • pp.165-171
    • /
    • 2023
  • Trauma remains a significant healthcare burden, causing over five million yearly fatalities. Notably, the liver is a frequently injured solid organ in abdominal trauma, especially in patients under 40 years. It becomes even more critical given that uncontrolled hemorrhage linked to liver trauma can have mortality rates ranging from 10% to 50%. Liver injuries, mainly resulting from blunt trauma such as motor vehicle accidents, are traditionally classified using the American Association for the Surgery of Trauma grading scale. However, recent developments have introduced the World Society of Emergency Surgery classification, which considers the patient's physiological status. The diagnostic approach often involves multiphase computed tomography (CT). Still, newer methods like split-bolus single-pass CT and contrast-enhanced ultrasound (CEUS) aim to reduce radiation exposure. Concerning management, nonoperative strategies have emerged as the gold standard, especially for hemodynamically stable patients. Incorporating angiography with embolization has also been beneficial, with success rates reported between 80% and 97%. However, it is essential to identify the specific source of bleeding for effective embolization. Given the severity of liver trauma and its potential complications, innovations in diagnostic and therapeutic approaches have been pivotal. While CT remains a primary diagnostic tool, methods like CEUS offer safer alternatives. Moreover, nonoperative management, especially when combined with angiography and embolization, has demonstrated notable success. Still, the healthcare community must remain vigilant to complications and continuously seek improvements in trauma care.

Study on the characteristics of airborne gross alpha and gross beta activities in the vicinity of nuclear facilities

  • Da-Young Gam;Chae-yeon Lee;Ji-Young Park;Hyuncheol Kim;Jong-Myoung Lim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4554-4560
    • /
    • 2023
  • Continuous monitoring of radioactive substances over a prolonged duration can yield crucial insights into the levels of radiation exposure through inhalation, both in the vicinity of nuclear facilities and/or general environments. In this study, we evaluated long-term measurements (2012-2022) of gross alpha-beta activities in the air in the vicinity of nuclear facilities and reference site, distribution characteristics of temporal trends and spatial fluctuations, and factors affecting radioactivity levels. The average airborne gross-α (in mBq m-3) for onsite and off-site were 0.124 and 0.117, respectively, and the average airborne gross-β (in mBq m-3) measurements were 1.10 and 1.04, respectively. The activity ratio (AR) of gross-α and gross-β were calculated as a ratio of 0.12. The distribution characteristics of gross-α and gross-β activities in this study area are likely influenced by the meteorological factors and variations in airborne PM concentrations rather than the operation of the nuclear facility.

Comparison of Operator Radiation Exposure Dose undergoing Cardiac Angiography and Cardiac Intervention (심장혈관 중재적 시술의 시술자 피폭 선량에 관한 연구)

  • Kim, Jungsu;Kwon, Soonmu;Jung, Haekyoung;Lee, Bongki;Ryu, Dongryeol;Kwon, Hoseok;Cho, Byungryul
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.181-186
    • /
    • 2016
  • Cardiac angiography(CA) or cardiac intervention(CI) is one of the major examination methods applied to the detection of cardiovascular diseases using X-rays. These CA and CI procedures require radiation exposure to patients and physicians. We evaluated the radiation dose to cardiac operator during the each case of CA and CI procedures. The number of patients is 113 patients in CA and 34 patients in CI. Mean fluoroscopy time, mean cine time, and mean total cumulative dose area product(DAP) in patients during CA and CI was 165.9 sec vs. 1200.0 sec, 30.31 sec vs 107.5 sec, and $37130.3mGy.cm^2$ vs $213312.6mGy.cm^2$, respectively. Mean dose of thyroid, over chest apron and under chest apron in operator during CA and CI was 15.84 uSv vs 89.81 uSv, 20.16 uSv vs 123.20 uSv, and 0.30 uSv vs 2.40 uSv, respectively. Mean effective dose of operator during CI was about 6 times greater than during CA. Also there was significant inter-relationship between fluoroscopy or cine time and effective dose in operator during CA and CI(p=0.001 and p=0.001, respectively).

Study of Scatter Influence of kV-Conebeam CT Based Calculation for Pelvic Radiotherapy (골반 방사선 치료에서 산란이 kV-Conebeam CT 영상 기반의 선량계산에 미치는 영향에 대한 연구)

  • Yoon, KyoungJun;Kwak, Jungwon;Cho, Byungchul;Kim, YoungSeok;Lee, SangWook;Ahn, SeungDo;Nam, SangHee
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.37-45
    • /
    • 2014
  • The accuracy and uniformity of CT numbers are the main causes of radiation dose calculation error. Especially, for the dose calculation based on kV-Cone Beam Computed Tomography (CBCT) image, the scatter affecting the CT number is known to be quite different by the object sizes, densities, exposure conditions, and so on. In this study, the scatter impact on the CBCT based dose calculation was evaluated to provide the optimal condition minimizing the error. The CBCT images was acquired under three scatter conditions ("Under-scatter", "Over-scatter", and "Full-scatter") by adjusting amount of scatter materials around a electron density phantom (CIRS062, Tissue Simulation Technology, Norfolk, VA, USA). The CT number uniformities of CBCT images for water-equivalent materials of the phantom were assessed, and the location dependency, either "inner" or "outer" parts of the phantom, was also evaluated. The electron density correction curves were derived from CBCT images of the electron density phantom in each scatter condition. The electron density correction curves were applied to calculate the CBCT based doses, which were compared with the dose based on Fan Beam Computed Tomography (FBCT). Also, 5 prostate IMRT cases were enrolled to assess the accuracy of dose based on CBCT images using gamma index analysis and relative dose differences. As the CT number histogram of phantom CBCT images for water equivalent materials was fitted with a gaussian function, the FHWM (146 HU) for "Full-scatter" condition was the smallest among the FHWM for the three conditions (685 HU for "under scatter" and 264 HU for "over scatter"). Also, the variance of CT numbers was the smallest for the same ingredients located in the center and periphery of the phantom in the "Full-scatter" condition. The dose distributions calculated with FBCT and CBCT images compared in a gamma index evaluation of 1%/3 mm criteria and in the dose difference. With the electron density correction acquired in the same scatter condition, the CBCT based dose calculations tended to be the most accurate. In 5 prostate cases in which the mean equivalent diameter was 27.2 cm, the averaged gamma pass rate was 98% and the dose difference confirmed to be less than 2% (average 0.2%, ranged from -1.3% to 1.6%) with the electron density correction of the "Full-scatter" condition. The accuracy of CBCT based dose calculation could be confirmed that closely related to the CT number uniformity and to the similarity of the scatter conditions for the electron density correction curve and CBCT image. In pelvic cases, the most accurate dose calculation was achievable in the application of the electron density curves of the "Full-scatter" condition.