• Title/Summary/Keyword: Radiation Field

Search Result 2,260, Processing Time 0.039 seconds

Verification of Indicator Rotation Correction Function of a Treatment Planning Program for Stereotactic Radiosurgery (방사선수술치료계획 프로그램의 지시자 회전 오차 교정 기능 점검)

  • Chung, Hyun-Tai;Lee, Re-Na
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.47-51
    • /
    • 2008
  • Objective: This study analyzed errors due to rotation or tilt of the magnetic resonance (MR) imaging indicator during image acquisition for a stereotactic radiosurgery. The error correction procedure of a commercially available stereotactic neurosurgery treatment planning program has been verified. Materials and Methods: Software virtual phantoms were built with stereotactic images generated by a commercial programming language, Interactive Data Language (version 5.5). The thickness of an image slice was 0.5 mm, pixel size was $0.5{\times}0.5mm$, field of view was 256 mm, and image resolution was $512{\times}512$. The images were generated under the DICOM 3.0 standard in order to be used with Leksell GammaPlan$^{(R)}$. For the verification of the rotation error correction function of Leksell GammaPlan$^{(R)}$, 45 measurement points were arranged in five axial planes. On each axial plane, there were nine measurement points along a square of length 100 mm. The center of the square was located on the z-axis and a measurement point was on the z-axis, too. Five axial planes were placed at z=-50.0, -30.0, 0.0, 30.0, 50.0 mm, respectively. The virtual phantom was rotated by $3^{\circ}$ around one of x, y, and z-axis. It was also rotated by $3^{\circ}$ around two axes of x, y, and z-axis, and rotated by $3^{\circ}$ along all three axes. The errors in the position of rotated measurement points were measured with Leksell GammaPlan$^{(R)}$ and the correction function was verified. Results: The image registration errors of the virtual phantom images was $0.1{\pm}0.1mm$ and it was within the requirement of stereotactic images. The maximum theoretical errors in position of measurement points were 2.6 mm for a rotation around one axis, 3.7 mm for a rotation around two axes, and 4.5 mm for a rotation around three axes. The measured errors in position was $0.1{\pm}0.1mm$ for a rotation around single axis, $0.2{\pm}0.2mm$ for double and triple axes. These small errors verified that the rotation error correction function of Leksell GammaPlan$^{(R)}$ is working fine. Conclusion: A virtual phantom was built to verify software functions of stereotactic neurosurgery treatment planning program. The error correction function of a commercial treatment planning program worked within nominal error range. The virtual phantom of this study can be applied in many other fields to verify various functions of treatment planning programs.

Effects for the Thermal Comfort Index Improvement of Park Woodlands and Lawns in Summer (여름철 공원 수림지와 잔디밭의 온열쾌적지수 개선 효과)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.6
    • /
    • pp.21-30
    • /
    • 2014
  • The purpose of this study was to evaluate human thermal comfort in summer by the type of greenery in parks and to explore planning solutions to supply a comfortable thermal environment in parks. The research was conducted in three different land cover types: a park with multi-wide-canopied trees(WOODLAND), park with grass(LAWN) and park with pavement(PAV) as reference sites in Hamyang-Gun SangrimPark. Field measurements of air temperature, relative humidity and wind velocity, short-wave and long-wave radiation from six directions(east, west, north, south, upward and downward) were carried out in the summer of 2014(August 21-23 and 29-30). Mean Radiant Temperature($T_{mrt}$) absorbed by a human-biometeorological reference person was estimated from integral radiation and the calculation of angular factors. The thermal comfort index PET was calculated by Rayman software, UTCI, OUT_SET$^*$ were calculated using the UTCI Calculator and the Thermal Comfort Calculator of Richard DeDear. The results showed that the WOODLAND has the maximum cooling effect during daytime, reduced air temperatures/$T_{mrt}$ by up to $5.9^{\circ}C/35^{\circ}C$ compared to PAV and lowered heat stress values despite increasing relative humidity values and decreasing wind velocity. While the LAWN had very slight cooling effects during daytime, reduced air temperatures/$T_{mrt}$ by up to $0.9^{\circ}C/3^{\circ}C$ compared to PAV, the improvement effects of the thermal comfort index was very slight. However, during nighttime the microclimatic and radiant conditions of WOODLAND, LAWN, and PAV were similar owing to the absence of solar radiation, reduction of wind velocity and an increase in relative humidity. Because the shading and evapotranspiration effects of the WOODLAND were much greater than the evapotranspiration effects of the LAWN, it can be said that the solutions for supplying comfortable thermal environment in parks are to amplify the green volumes rather than green areas. This study was undertaken to evaluate the human thermal comfort in summer of WOODLAND/LAWN parks and to determine the improvement effects of thermal comfort index. These results can contribute to the provision better thermal comfort for park users during park planning.

Measurement of Specific Radioactivity for Clearance of Waste Contaminated with Re-186 for Medical Application (의료용 Re-186 오염폐기물의 규제해제를 위한 방사능측정)

  • Kim, Chang-Bum;Lee, Sang-Kyung;Jang, Seong-Joo;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.633-638
    • /
    • 2017
  • The amount of radioactive waste has been rapidly increased with development of radiation treatment in medical field. Recently, it has been a common practice to use I-131 for thyroid cancer, F-18 for PET/CT and Tc-99m for diagnosis of nuclear medicine. All the wastes concerned have been disposed of by means of the self-disposal method, for example incineration, after storage enough to decay less than clearance level. IAEA proposed criteria for clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). In this study, specific radioactivity of radioactive waste contaminated with Re-186 was measured to confirm whether it meets the clearance level. Re-186 has long half life of 3.8 days relatively and emits beta and gamma radiation, therefore it can be applied in treatment and imaging purposes. The specific radioactivity of contaminated gloves weared by radiation workers was measured by MCA(Multi-channel Analyzer) which was calibrated by reference materials in accordance with the measuring procedure. As a result, comparison evaluation of decay storage period between the half-life which was calculated by attenuation curve based on real measurement and physical half-life was considered, and it is showed that the physical half-life is longer than induced half-life. Therefore, the storage period of radioactive waste for self-disposal may be curtailed in case of application of induced half-life. The result of this study will be proposed as ISO standard.

Truncation Artifact Reduction Using Weighted Normalization Method in Prototype R/F Chest Digital Tomosynthesis (CDT) System (프로토타입 R/F 흉부 디지털 단층영상합성장치 시스템에서 잘림 아티팩트 감소를 위한 가중 정규화 접근법에 대한 연구)

  • Son, Junyoung;Choi, Sunghoon;Lee, Donghoon;Kim, Hee-Joung
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.111-118
    • /
    • 2019
  • Chest digital tomosynthesis has become a practical imaging modality because it can solve the problem of anatomy overlapping in conventional chest radiography. However, because of both limited scan angle and finite-size detector, a portion of chest cannot be represented in some or all of the projection. These bring a discontinuity in intensity across the field of view boundaries in the reconstructed slices, which we refer to as the truncation artifacts. The purpose of this study was to reduce truncation artifacts using a weighted normalization approach and to investigate the performance of this approach for our prototype chest digital tomosynthesis system. The system source-to-image distance was 1100 mm, and the center of rotation of X-ray source was located on 100 mm above the detector surface. After obtaining 41 projection views with ${\pm}20^{\circ}$ degrees, tomosynthesis slices were reconstructed with the filtered back projection algorithm. For quantitative evaluation, peak signal to noise ratio and structure similarity index values were evaluated after reconstructing reference image using simulation, and mean value of specific direction values was evaluated using real data. Simulation results showed that the peak signal to noise ratio and structure similarity index was improved respectively. In the case of the experimental results showed that the effect of artifact in the mean value of specific direction of the reconstructed image was reduced. In conclusion, the weighted normalization method improves the quality of image by reducing truncation artifacts. These results suggested that weighted normalization method could improve the image quality of chest digital tomosynthesis.

Evaluation of Rice Protein Content Variation on Cultivation and Environmental Conditions (재배 및 환경조건에 따른 쌀 단백질 함량 변동 평가 )

  • Yun-Ho, Lee;Jeong-Won, Kim;Jae-Hyeok, Jeong;Woon-Ha, Hwang;Hyeon-Seok, Lee;Seo-Yeong, Yang;Chung-Keun, Lee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.24 no.4
    • /
    • pp.267-274
    • /
    • 2022
  • The effect of year, varieties, nitrogen application, and transplant time were examined in relation to rice of protein. An experiment was conducted using 12 rice varieties to investigate the effect of management and weather conditions on brown rice protein of during the filling stage. The transplanting time was set to be three groups including early, medium, and late timing. The nitrogen application was set to be 0 N kg / 10a, 9N kg / 10a and 18 N kg / 10a to examine the effect of fertilizer management on protein content. Field experiments were conducted in three growing seasons including 2019, 2020, and 2021. The brown rice of protein content were 5.7%, 5.9%, and 6.6% under early, medium, and late transplanting time conditions, respectively. The protein content differ by variety. For example, Chucheong, Hopum, Ilpum, Mipum, Odae, Saenuri, and Saeilmi had more than 6.1%, and Chindeul, Shindongjin, Samkwang, Unkwang, Younhojinmi were less than 6.1%. Nitrogen content was 5.7% for 0kgN /10a, 6.1% for 9kgN /10a, and 6.8% for 18kgN /10a. The contribution of the characteristics to the protein content was highest in nitrogen content (38.8%), followed by transplanting time (13.7%), variety (8.2%), and year (3.5%). The average temperature for 20 days after heading time was the highest (9.3%), followed by sunshine duration (3.9%) and solar radiation (3.5%). Our results revealed that brown rice protein content was determined to be affected by changes in average temperature, sunshine duration and solar radiation for 20 days after heading time. This suggested that assessment of temperature and solar radiation after heading time would indicate the degree of rice quality in terms of protein.

Korean Practice Guidelines for Gastric Cancer 2022: An Evidence-based, Multidisciplinary Approach

  • Tae-Han Kim;In-Ho Kim;Seung Joo Kang;Miyoung Choi;Baek-Hui Kim;Bang Wool Eom;Bum Jun Kim;Byung-Hoon Min;Chang In Choi;Cheol Min Shin;Chung Hyun Tae;Chung sik Gong;Dong Jin Kim;Arthur Eung-Hyuck Cho;Eun Jeong Gong;Geum Jong Song;Hyeon-Su Im;Hye Seong Ahn;Hyun Lim;Hyung-Don Kim;Jae-Joon Kim;Jeong Il Yu;Jeong Won Lee;Ji Yeon Park;Jwa Hoon Kim;Kyoung Doo Song;Minkyu Jung;Mi Ran Jung;Sang-Yong Son;Shin-Hoo Park;Soo Jin Kim;Sung Hak Lee;Tae-Yong Kim;Woo Kyun Bae;Woong Sub Koom;Yeseob Jee;Yoo Min Kim;Yoonjin Kwak;Young Suk Park;Hye Sook Han;Su Youn Nam;Seong-Ho Kong;The Development Working Group for the Korean Practice Guidelines for Gastric Cancer 2022 Task Force Team
    • Journal of Gastric Cancer
    • /
    • v.23 no.1
    • /
    • pp.3-106
    • /
    • 2023
  • Gastric cancer is one of the most common cancers in Korea and the world. Since 2004, this is the 4th gastric cancer guideline published in Korea which is the revised version of previous evidence-based approach in 2018. Current guideline is a collaborative work of the interdisciplinary working group including experts in the field of gastric surgery, gastroenterology, endoscopy, medical oncology, abdominal radiology, pathology, nuclear medicine, radiation oncology and guideline development methodology. Total of 33 key questions were updated or proposed after a collaborative review by the working group and 40 statements were developed according to the systematic review using the MEDLINE, Embase, Cochrane Library and KoreaMed database. The level of evidence and the grading of recommendations were categorized according to the Grading of Recommendations, Assessment, Development and Evaluation proposition. Evidence level, benefit, harm, and clinical applicability was considered as the significant factors for recommendation. The working group reviewed recommendations and discussed for consensus. In the earlier part, general consideration discusses screening, diagnosis and staging of endoscopy, pathology, radiology, and nuclear medicine. Flowchart is depicted with statements which is supported by meta-analysis and references. Since clinical trial and systematic review was not suitable for postoperative oncologic and nutritional follow-up, working group agreed to conduct a nationwide survey investigating the clinical practice of all tertiary or general hospitals in Korea. The purpose of this survey was to provide baseline information on follow up. Herein we present a multidisciplinary-evidence based gastric cancer guideline.

The 1998, 1999 Patterns of Care Study for Breast Irradiation after Mastectomy in Korea (1998, 1999년도 우리나라에서 시행된 근치적 유방 전절제술 후 방사선치료 현황 조사)

  • Keum,, Ki-Chang;Shim, Su-Jung;Lee, Ik-Jae;Park, Won;Lee, Sang-Wook;Shin, Hyun-Soo;Chung, Eun-Ji;Chie, Eui-Kyu;Kim, Il-Han;Oh, Do-Hoon;Ha, Sung-Whan;Lee, Hyung-Sik;Ahn, Sung-Ja
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.7-15
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: To determine the patterns of evaluation and treatment in patients with breast cancer after mastectomy and treated with radiotherapy. A nationwide study was performed with the goal of improving radiotherapy treatment. $\underline{Materials\;and\;Methods}$: A web- based database system for the Korean Patterns of Care Study (PCS) for 6 common cancers was developed. Randomly selected records of 286 eligible patients treated between 1998 and 1999 from 17 hospitals were reviewed. $\underline{Results}$: The ages of the study patients ranged from 20 to 80 years (median age 44 years). The pathologic T stage by the AJCC was T1 in 9.7% of the cases, T2 in 59.2% of the cases, T3 in 25.6% of the cases, and T4 in 5.3% of the cases. For analysis of nodal involvement, N0 was 7.3%, N1 was 14%, N2 was 38.8%, and N3 was 38.5% of the cases. The AJCC stage was stage I in 0.7% of the cases, stage IIa in 3.8% of the cases, stage IIb in 9.8% of the cases, stage IIIa in 43% of the cases, stage IIIb in 2.8% of the cases, and IIIc in 38.5% of the cases. There were various sequences of chemotherapy and radiotherapy after mastectomy. Mastectomy and chemotherapy followed by radiotherapy was the most commonly performed sequence in 47% of the cases. Mastectomy, chemotherapy, and radiotherapy followed by additional chemotherapy was performed in 35% of the cases, and neoadjuvant chemoradiotherapy was performed in 12.5% of the cases. The radiotherapy volume was chest wall only in 5.6% of the cases. The volume was chest wall and supraclavicular fossa (SCL) in 20.3% of the cases; chest wall, SCL and internal mammary lymph node (IMN) in 27.6% of the cases; chest wall, SCL and posterior axillary lymph node in 25.9% of the cases; chest wall, SCL, IMN, and posterior axillary lymph node in 19.9% of the cases. Two patients received IMN only. The method of chest wall irradiation was tangential field in 57.3% of the cases and electron beam in 42% of the cases. A bolus for the chest wall was used in 54.8% of the tangential field cases and 52.5% of the electron beam cases. The radiation dose to the chest wall was $45{\sim}59.4\;Gy$ (median 50.4 Gy), to the SCL was $45{\sim}59.4\;Gy$ (median 50.4 Gy), and to the PAB was $4.8{\sim}38.8\;Gy$, (median 9 Gy) $\underline{Conclusion}$: Different and various treatment methods were used for radiotherapy of the breast cancer patients after mastectomy in each hospital. Most of treatment methods varied in the irradiation of the chest wall. A separate analysis for the details of radiotherapy planning also needs to be followed and the outcome of treatment is needed in order to evaluate the different processes.

A Retrospective Study of the Radiotherapy Care Patterns for Patients with Laryngeal Cancer and Comparison of Different Korean Hospitals Treated from 1998 through 1999 (한국인 후두암 환자의 방사선치료 과정 및 내용에 관한 분석 (1998~1999년도))

  • Chung, Woong-Ki;Kim, Il-Han;Yoon, Mee-Sun;Ahn, Sung-Ja;Nam, Taek-Keun;Song, Ju-Young;Chung, Jae-Uk;Nah, Byung-Sik;Lee, Joon-Kyoo;Wu, Hong-Gyun;Lee, Chang-Geol;Lee, Sang-Wook;Park, Won;Ahn, Yong-Chan;Kang, Ki-Moon;Kim, Jung-Soo;Oh, Yoon-Kyeong;Cho, Moon-June;Park, Woo-Yoon;Kim, Jin-Hee;Choi, Doo-Ho;Yun, Hyong-Geun;Kim, Woo-Cheol;Yang, Dae-Sik;Sohn, Seung-Chang;Suh, Hyun-Suk;Ahn, Ki-Jung;Chun, Mi-Son;Lee, Kyu-Chan;Choi, Young-Min;Jeung, Tae-Sik;Kang, Jin-Oh
    • Radiation Oncology Journal
    • /
    • v.27 no.4
    • /
    • pp.201-209
    • /
    • 2009
  • Purpose: To investigate the care patterns for radiation therapy and to determine inter-hospital differences for patients with laryngeal carcinoma in Korea. Materials and Methods: A total of 237 cases of laryngeal carcinoma (glottis, 144; supraglottis, 93) assembled from 23 hospitals, who underwent irradiation in the year of 1998 and 1999, were retrospectively analyzed to investigate inter-hospital differences with respect to radiotherapy treatment. We grouped the 23 hospitals based on the number of new patients annually irradiated in 1998; and designated them as group A (${\geq}$900 patients), group B (${\geq}$400 patients and <900 patients), and group C (<400 patients). Results: The median age of the 237 patients was 62 years (range, 25 to 88 years), of which 216 were male and 21 were female. The clinical stages were distributed as follows: for glottis cancer, I; 61.8%, II; 21.5%, III; 4.2%, IVa; 11.1%, IVb; 1.4%, and in supraglottic cancer, I; 4.3%, II; 19.4%, III; 28.0%, IVa; 43.0%, IVb; 5.4%, respectively. Some differences were observed among the 3 groups with respect to the dose calculation method, radiation energy, field arrangement, and use of an immobilization device. No significant difference among 3 hospital groups was observed with respect to treatment modality, irradiation volume, and median total dose delivered to the primary site. Conclusion: This study revealed that radiotherapy process and patterns of care are relatively uniform in laryngeal cancer patients in Korean hospitals, and we hope this nationwide data can be used as a basis for the standardization of radiotherapy for the treatment of laryngeal cancer.

A Study of Content Analysis on ICU(Intensive Care Unit) Nurses' Knowledge of Basic Nursing Sciences (중환자실 간호사의 기초간호과학 지식의 필요성 분석)

  • Byeon, Young-Soon;Choe, Myoung-Ae;Kim, Hee-Seung;Park, Mi-Jung;Seo, Wha-Sook;Lee, Kyung-Sook;Choi, S-Mi;Hong, Hae-Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.4 no.1
    • /
    • pp.41-49
    • /
    • 2002
  • The purpose of this study was to identify the knowledge contents of basic nursing sciences needed by nurses in the practices of the intensive care unit(ICU). To attain the goal of this study, the nurses working at 10 hospitals in the areas of Seoul and Kangwon Province were randomly selected. They were primarily interviewed, and the open question was secondarily put to them through the questionnaire. In the process of the 1st interview, the interviewees were asked of the question, "What is the knowledge of basic sciences such as anatomy, pathology, physiology. microbiology, pharmacology and the like thought to be lacking when you communicate with doctors in the ICU and when you carry out your nursing practices in it?" The contents of the interview were tape-recorded. The period of data collection ranged from May 1, 2001 to Sept 30. The interviews were conducted with total of 20 nurses. The open-end questionnaire was secondarily mailed to nurses. 113 questionnaires were returned. 100 questionnaires except 13 ones thought to be poorly completed in content were used for data analysis. Three coders classified data obtained from the interview and the questionnaire research into 5 detailed items relating to such as anatomical physiology, pathology, pharmacology. microbiology and basics of nursing. The three coders had experiences in nursing education of 18 years, 8 years and 6 years, respectively, and of them one coder was professor in basic nursing sciences. Data were statistically treated using frequency analysis and percentage by the SAS program. As a result, the following findings were obtained : It was found that the contents that ICU nurses responded were most needed in the field of Human structure and function were water and electrolytic balance(38%), blood and circulatory system(20%), changer in the patient's skin(12%), the arrangement of the human body(10%) and the endocrine system(10%), nervous system(6%), and assessment of the state of the patient's consciousness(4%). It was found that the contents that ICU nurses responded were most needed in the field of pathology were found to be the process of the progress of the disease(32%), symptoms of the disease(27%), prognosis of the disease(22%), followed by the injury-healing process, clinical pathological examination, and examination by radiation. It was found that the contents that nurses responded were most needed in the field of pharmacology were the effect of drug(25%), the side effect of drug(22%), the relationship between diseases and drug(20%), the relationship between disease-causing bacteria and drug(20%) and chemotherapy(2%). It was found that the contents that ICU nurses responded were most needed in the field of microbiology were the relationship between diseases and disease-causing bacteria(45%), Kinds and characteristics of disease-causing bacteria(18%), infection control(16%), application of the aseptic technique(12%), isolation(9%) and the like. It was found that the basic knowledge that ICU nurses responded were needed were the identification of the patient's current state(36%), understanding of the therapeutic process(22%), the operating principle of medical equipment and instrument(20%), medical terminology(9%), equipment and instrument management(7%), calculation of the dose of injection(2%) and the like.

  • PDF

Comparison of Dosimetry Protocols in High Energy Electron Beams (고에너지 전자선에 대한 표준측정법간의 비교)

  • 박성용;서태석;김회남;신동오;지영훈;군수일;이길동;추성실;최보영
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.267-276
    • /
    • 1998
  • Any detector inserted into a phantom should have such a geometry that it caused as small as possible perturbation of the electron fluence. Plane parallel chambers meet this requirement better than other chambers of configurations. IAEA protocol recommends the use of plane parallel chambers for this reason. However, the cylindrical chambers are widely used for convenient. The purpose of this study is to evaluate the absorbed dose due to the differences of four different dosimetry protocols such as IAEA protocol using cylindrical chamber, TG 21 protocol using cylindrical chamber, Markus protocol using plane parallel chamber, and TG 39 report for the calibration of plane parallel chamber in electron beams. Depth-ionization measurements for the electron beams of nominal energy 6, 9, 12, 15, and 18 MeV from Siemens accelerator with a 10$\times$10 cm$^2$ field size were made using a radiation field analyser with 0.125 cc ion chamber. Dosimetric measurements by IAEA and TG 21 protocol were made with a farmer type ionization chamber in solid water for each electron energy, respectively. Dosimetric measurements by Markus protocol were made with a plane parallel ionization chamber in solid water for each electron energy, respectively. The cavity-gas calibration factor for the plane parallel chamber was obtained with the use of 18 MeV electron beam as guided by TG 39 report. Dosimetric measurements by TG 39 were performed with a plane parallel ionization chamber in solid water for each electron energy, respectively. For all the energies and protocols, measurements were made along the central axis of the distance of 100 cm (SSD = 100 cm) with 10$\times$10 cm$^2$ field size at the depth of d$_{max}$ for each electron beam, respectively. In the case of 18 MeV, the discrepancy of 0.9 % between IAEA and TG 21 was found and the two protocols were agreed within 0.7 % for other energies. In the case of 18 MeV and 6 MeV, the discrepancies of $\pm$ 0.8 % between Markus and TG 39 was found, respectively and the two protocols were agreed within 0.5 % for other energies. Since the discrepancy of 1.6 % between cylindrical and plane parallel chamber was found for 18 MeV, it is suggested to get the calibration factor using other method as guided. by TG 39.9.

  • PDF