• Title/Summary/Keyword: Radiation Efficient

Search Result 453, Processing Time 0.024 seconds

DataBase system construction for the study of radiation hardened electronic devices using pulse radiation (펄스방사선을 이용한 내방사선 연구 DB 구축)

  • Ko, Seong-Gon;Oh, Seung-Chan;Hwang, Young-Gwan;Jeong, Sang-Hun;Lee, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.778-781
    • /
    • 2012
  • The electronic element the damage occurs with radiation being bombed. In order applies in the artificial satellite or the space ship therefore from the within has radiation introspection the use of the radiation electronic element is essential. Transient radiation tests performed for the first time in Korea evaluation data database (DB) was constructed to. Web-based materials in the DB is designed to be able to search and update, and existing foreign (NASA, ESA) for a total of 695 species, including public sources of data has been entered. Search DB than the existing foreign DB is an efficient and practical.

  • PDF

Study of occupational exposure in PET/CT (PET/CT 종사자의 방사선피폭에 관한 연구)

  • Na, Soo-Kyung;Park, Byung-Sub;Kang, Yong-Gil
    • Journal of Digital Convergence
    • /
    • v.10 no.11
    • /
    • pp.449-457
    • /
    • 2012
  • The purpose of this study is to investigate the relationship between radiation origin and health professionals, and to reduce exposed dose of radiation through efficient management. Increasing exposed dose of radiation to health professionals are caused by the increase of PET/CT use and a radioactive isotope. Hence, in this study, space dose from each origin of radiation generating was analyzed and the use of personnel protective clothing and shields was compared. As a result of this study, we confirmed that the exposed dose of radiation was much higher in case of wearing personnel protective clothing(0.5 mm pb) than no wearing personnel protective clothing under high energy gamma radiation(511 keV) of the position emitter($^{18}F$).

Comparison of Dosimetric Parameters Based on Beam Arrangement Changes in HA-WBRT by Using VMAT Technique: A Phantom Study (VMAT 기법을 활용한 HA-WBRT에서 빔 배열 변화에 따른 선량학적 인자 비교: 팬텀 연구)

  • Sung-Kuk Park;Dong-Hyun Kim
    • Journal of radiological science and technology
    • /
    • v.47 no.4
    • /
    • pp.271-278
    • /
    • 2024
  • This study aimed to evaluate the impact of changes in beam arrangement and arc counts on dosimetric factors in volumetric modulated arc therapy (VMAT) inverse radiation therapy planning for hippocampal-avoidance whole brain radiation therapy (HA-WBRT) by using the Elekta Monaco radiation therapy planning system (RTPs). For coplanar VMAT, both the arc per beam (APB) method and the beam determined arc(BDA) method, which is determined by the number of beams, were applied. For non-coplanar VMAT, the BDA method was utilized, and a total of 9 treatment plans were established by varying the arc counts. All radiation therapy plans met the radiation oncology group (RTOG) 0933 protocol standards, and 14 dosimetric factors were compared and analyzed. The results showed that the BDA-NC VMAT method demonstrated superior performance in terms of planning target volume (PTV) coverage and protection of normal organs, while APB-VMAT was advantageous in terms of hippocampal protection, monitor unit and delivery time. This study is expected to contribute to the efficient establishment of HA-WBRT plans considering the changes in beam arrangement and rotation arc numbers in Monaco RTPs.

Synthesis of 125I-labeled tetrazine for efficient radiolabeling of human serum albumin

  • Shim, Ha Eun;Jeon, Jongho
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.2
    • /
    • pp.98-102
    • /
    • 2017
  • We demonstrate a detail protocol for the radiosynthesis of a $^{125}I-labeled$ tetrazine prosthetic group and its application to the efficient radiolabeling of trans-cyclooctene-group conjugated human serum albumin (3) using inverse-electron-demand Diels-Alder reaction. Radioiodination of the stannylated precursor (2) was carried out by using [$^{125}I$]NaI and chloramine T as an oxidant at room temperature for 15 min. After HPLC purification of the crude product, the purified $^{125}I-labeled$ azide ([$^{125}I$]1) was obtained with high radiochemical yield ($65{\pm}8%$, n = 5) and excellent radiochemical purity (>99%). Inverse-electron-demand Diels-Alder reaction between ([$^{125}I$]1) and 3 gave the $^{125}I-labeled$ human serum albumin ([$^{125}I$]4) with more than 99% of radiochemical yield as determined by radio-thin-layer chromatography (radio-TLC). These results clearly indicate that the present radiolabeling method will be useful for the efficient and convenient radiolabeling of trans-cyclooctene-group containing biomolecules.

Difference in Understanding of the Need for Using Radiation in Various Fields between Students Majoring in Radiation and Non-Radiation Related Studies (전공자와 비전공자 대학생 간의 방사선이용 분야별 필요성인식 수준 차이)

  • Han, Eun-Ok
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.4
    • /
    • pp.230-236
    • /
    • 2011
  • As a way of improving social receptivity of using radiation, this study looked into the difference of understanding the need of using radiation in various fields between students majoring in radiation and non-radiation related studies, who will influence public opinion in the long term. This study also provides data needed for developing efficient strategies for projects promoting the public's awareness of using radiation. Of the students in the 79 schools sampled, 24%(177) were in 4 year colleges and 146 were junior colleges in educational statistics service (http://cesi.kedi.re.kr) In November 2010 1,945 students were selected as a sample, and they were given surveys on the need of using radiation in different fields. As a result, both between students majoring in radiation and non-radiation related studies showed a high level of understanding the need for radiation in the medical field and showed a low level of understanding of the need for radiation in the agricultural field. In all 6 fields of radiation use, students majoring in radiation related studies showed higher levels of understanding for the need to use radiation than students majoring in radiation and non-radiation related studies. In each field, male students and those who have experience medical radiation and relevant education had higher level of understanding. This shows we need to improve the understanding of the cases of female students and those who have not had experiences with medical radiation and to provide relevant education through various kinds of information. The characteristics of the groups that are shown in the results of this study are considered to be helpful for efficiently for project promoting the public's awareness of using radiation.

Liver dose reduction by deep inspiration breath hold technique in right-sided breast irradiation

  • Haji, Gunel;Nabizade, Ulviye;Kazimov, Kamal;Guliyeva, Naile;Isayev, Isa
    • Radiation Oncology Journal
    • /
    • v.37 no.4
    • /
    • pp.254-258
    • /
    • 2019
  • Purpose: Deep inspiration breath hold (DIBH) is a well-established technique that enables efficient cardiac sparing in patients with left-sided breast cancer. The aim of the current study was to determine if DIBH is effective for reducing radiation exposure of of liver and other organs at risk in right breast radiotherapy (RT). Materials and Methods: Twenty patients with right-sided breast cancer were enrolled in this study. Three-dimensional conformal RT plans were generated for each patient, with two different computed tomography scans of free breathing (FB) and DIBH. Nodes were contoured according to the Radiation Therapy Oncology Group contouring guidelines. Dose-volume histograms for the target volume coverage and organs at risk were evaluated and analyzed. Results: DIBH plans showed significant reduction in mean liver dose (5.59 ± 2.07 Gy vs. 2.54 ± 1.40 Gy; p = 0.0003), V20Gy (148.38 ± 73.05 vs. 64.19 ± 51.07 mL; p = 0.0003) and V10Gy (195.34 ± 93.57 vs. 89.81 ± 57.28 mL; p = 0.0003) volumes compared with FB plans. Right lung doses were also significantly reduced in DIBH plans. Heart and left lung doses showed small but statistically significant improvement with application of the DIBH technique. Conclusion: We report that the use of DIBH for right-sided breast cancer significantly reduces the radiation doses to the liver, lungs, and heart.

The Study on the Optimal Angle of the Solar Panel using by Solar Radiation Model (태양복사모델을 이용한 태양전지판의 최적 경사각에 대한 연구)

  • Jee, Joon-Bum;Choi, Young-Jean;Lee, Kyu-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.2
    • /
    • pp.64-73
    • /
    • 2012
  • The angle of solar panels is calculated using solar radiation model for the efficient solar power generation. In ideal state, the time of maximum solar radiation is represented from 12:08 to 12:40 during a year at Gangneung and it save rage time is12:23. The maximum solar radiation is 1012$W/m^2$ and 708$W/m^2$ inc lear sky and cloudy sky, respectively. Solar radiation is more sensitive to North-South (N-S) slope angle than East-West (E-W) azimuth angle. Daily solar radiation on optimum angle of solar panel is higher than that on horizontal surface except for 90 days during summer. In order to apply to the real atmosphere, the TMY (typical meteorological Year) data which obtained from the 22 solar sites operated by KMA(Korea Meteorological Administration) during 11 years(2000 to 2010) is used as the input data of solar radiation model. The distribution of calculated solar radiation is similar to the observation, except in Andong, where it is overestimated, and in Mokpo and Heuksando, where it is underestimated. Statistical analysis is performed on calculated and observed monthly solar radiation on horizontal surface, and the calculation is overestimated from the observation. Correlationis 0.95 and RMSE (Root Mean Square Error) is10.81 MJ. The result shows that optimum N-S slope angles of solar panel are about $2^{\circ}$ lower than station latitude, but E-W slope angles are lower than ${\pm}1^{\circ}$. There are three types of solar panels: horizontal, fixed with optimum slope angle, and panels with tracker system. The energy efficiencies are on average 20% higher on fixed solar panel and 60% higher on tracker solar panel than compared to the horizontal solar panel, respectively.

Analysis of a Lead Vest Dose Reduction Effect for the Radiation Field at Major Working Places during Refueling Outage of Korean PWR Nuclear Power Plants (국내 가압경수로형 원전 계획예방정비기간 주요 방사선작업에 대한 납 차폐복 선량저감효과 분석)

  • Kim, Jeong-In;Lee, Byoung-Il;Lim, Young-Khi
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.237-241
    • /
    • 2013
  • The gamma energy distributions at the major working places during refueling outage of Korean PWR nuclear power plants were measured. In order to estimate the dose reduction effect of a lead vest, Monte Carlo calculation method was used. For the simulations, the MIRD-V phantom with a lead vest was formed and exposed to the measured radiation field. The average measured gamma energy is lower than that of standard which is generally applied to radiation protection procedures. For the efficient use of a lead vest and achievement of radiation protection purpose, it is necessary to estimate the energy distribution of radiation field at working places.

The Inhibitory Potency of Hesperidin on Protein Kinase C Activity Using a Biochip (바이오칩을 이용한 Protein Kinase C의 활성에 대한 헤스페리딘의 저해 효과)

  • Kang, Jung Ae;Rho, Jong Kook;Choi, Mi Hee;Jung, Young Jin;Park, Sang Hyun
    • Journal of Radiation Industry
    • /
    • v.5 no.1
    • /
    • pp.15-20
    • /
    • 2011
  • Protein kinases are the most important drug targets for the treatment of numerous diseases. The involvement of protein kinase C (PKC) in many biological processes such as development, memory, cell differentiation, and proliferation has been demonstrated. PKC is recognized as an important player in carcinogenesis. Thus, a variety of PKC inhibitors have been investigated. Among them, flavonoids have been demonstrated to affect the activity of many mammalian in vitro enzyme systems. The recent investigation was performed to evaluate the inhibitory effects of hesperidin, which is a flavonoid, on the proliferation and carcinogenesis of many cancers. In this study, an efficient kinase assay based on a biochip using radio-phosphorylation was established and performed for an examination of the inhibitory effects of hesperidin on PKC activity at different concentrations of 50, 200, 500 nM. It was found that hesperidin shows inhibitory potency on PKC, and that the biochip can be used to rapidly screen kinase inhibitors resulting in the therapeutic agents.

Problems of the Act and Subordinate Statutes Related to the Regulation of Radiation Safety for Diagnosis (진단용 방사선 안전관리 법령의 문제점에 관한 연구)

  • Lim, Chang-Seon
    • The Korean Society of Law and Medicine
    • /
    • v.23 no.2
    • /
    • pp.97-118
    • /
    • 2022
  • The use of diagnostic radiation in medical institutions is rapidly increasing. Accordingly, the collective effective dose is on the rise every year. Therefore, it is necessary to reduce the radiation exposure of the person undergoing the radiation examination as low as reasonably achievable. And we must establish a legal system to perform the safe management of radiation for diagnosis efficiently. In this way, I went over the problems of the Act and Subordinate Statutes regarding radiation safety management for diagnosis. As a result, the main contents are as follows. First, in the 「Medical Service Act」, there is no basis for the Safety Inspection Institute of Radiation and Radiation Exposure Measuring Institutes. And there are no provisions concerning delegation of administrative disposition. Therefore, it is necessary to secure legal justification by providing the basis for the Safety Inspection Institute of Radiation along with Radiation Exposure Measuring Institutes and the basis for administrative dispositions against these institutions in the 「Medical Service Act」. Second, the 「Rules on the Installation and Operation of Special Medical Equipment 」 should be integrated with the 「Rules on the Safety Management of Radiation Generators for Diagnostics」 to unify administrative procedures such as reporting for radiation special medical equipment for diagnosis. Third, in the case of violating the diagnostic radiation safety management standards in the 「Rules on the Safety Management of Radiation Generators for Diagnostics」, it is necessary to supplement the insufficient sanctions such as administrative disposition. Fourth, regulating diagnostic radiation and therapeutic radiation used in medical institutions with the dual legal system of the 「Medical Act」 and the 「Nuclear Safety Act」 is not efficient in the safety management of diagnostic radiation. Therefore, it is necessary to uniformly regulate diagnostic radiation and all medical radiation, including therapeutic radiation and nuclear medicine, in the 「Medical Service Act」 system.