• 제목/요약/키워드: Radiation Dosimeter

검색결과 409건 처리시간 0.042초

Evaluation of the Lens-absorbed Dose of the Scattered Radiation Generated During Tomotherapy IMRT to the H&N Cancer Patient

  • Choi, Jae-Won;Lee, Hae-Kag;Cho, Jae-Hwan;Choi, Cheon Woong;Ju, Myung Sik;Chang, Bok Soon;Park, Cheol-Soo
    • Journal of Magnetics
    • /
    • 제22권1호
    • /
    • pp.141-145
    • /
    • 2017
  • This paper uses a glass dosimeter to evaluate the lens-absorbed dose of scattered radiation generated in tomotherapy intensity modulated radiation therapy (IMRT). The head and neck portion of the rando phantom was subjected to a CT scan. The tomotherapy plan was designed to ensure delivery of the prescribed total 70 Gy day 2.2 Gy. With the lens portion of the glass dosimeter, a 5mm bolus was subjected to the scattered radiation treatment, and the dose was measured in each of the three megavoltage CT (MVCT) modes. The result is multiplied by 30 times and was determined once as the mean value. The measurement at the MVCT Coarse mode is RT mode 10.797 mGy, that for the Normal mode is 13.360 mGy, for the Fine mode is a maximum of 22.872 mGy, and for the treatment mode is 895.830 mGy. A small amount of scattered radiation in the MVCT is measured in the lens scattered radiation, but scattered radiation during treatment was measured to be near 1 Gy on the lens. Compared to a one-time radiation treatment of 2.2 Gy, the survey showed something unexpected in that it was half the value of that research to the patient. Therefore, will be aware of how much of an influence there will be on sensitive organs, such as the lens by scattered radiation generated during intensity modulated radiation therapy.

방사선 치료 시 산란선 및 누설선에 의한 표면선량 분포에 관한 연구 (A Study on the Surface Dose Distribution by Scattered and Leakage Radiation in Radiation Therapy)

  • 강종수;정동경;김용민
    • 한국방사선학회논문지
    • /
    • 제12권3호
    • /
    • pp.351-357
    • /
    • 2018
  • 방사선 치료 시 환자는 부득이하게 산란선과 누설선에 의한 2차 방사선 피폭을 받게 된다. 진단용 방사선의 경우 진단참조준위로 환자의 피폭을 줄이기 위한 가이드라인을 제시하고 있지만 치료용 방사선의 경우 2차 방사선에 의한 피폭선량이 상당함에도 불구하고 상한치 설정 시 치료 효과의 저감을 이유로 선량을 제한하지 않고 있다. 이에 본 연구는 선형가속기를 이용한 방사선 치료 시 원거리 조직에서 환자가 받을 수 있는 2차 방사선을 형광유리선량계로 측정하였으며 형광유리선량계의 빌드업 특성에 따른 형광량의 포화도를 측정하였다. 연구 결과 조사야 경계로부터 거리가 멀어질수록 피폭선량은 급격히 줄어들었으며, 두부 1 Gy 조사 시 경부 18.45 mGy, 경부 1 Gy 조사 시 두부 15.55 mGy, 흉부 1 Gy 조사 시 경부 14.26 mGy, 골반 1 Gy 조사 시 흉부 1.14 mGy로 피폭되었다. 형광량의 포화도는 판독시점에 따라 1.8 ~ 4.8% 정도 과대평가 될 수 있음을 확인하였다.

Postal Dosimetry Audits for the Domestic Medical Linear Accelerator

  • Kim, Kum Bae;Choi, Sang Hyoun
    • 한국의학물리학회지:의학물리
    • /
    • 제31권2호
    • /
    • pp.20-28
    • /
    • 2020
  • Purpose: The objective of this study is to perform Postal dosimetry audits for medical linear accelerators in radiation therapy institutions using glass dosimeters and Gafchromic film reading systems and postal dosimetry audit procedures, and to evaluate radiation therapy doses and mechanical accuracy in medical institutions. Methods: Photon output measured and analyzed using a standard phantom for measuring photon output dose using a glass dosimeter for medical linear accelerators. Mechanical accuracy was measured and analyzed using software for film measurement. Results: Measurement and analysis of photon beam output dose using a standard phantom glass dosimeter for photon beam output dose measurement was completed. All tolerance doses were within 5%. Mechanical accuracy measurement and analysis using a standard phantom for verifying the mechanical accuracy of linear accelerator (LINAC) using a Gafchromic film were completed, and all results were shown within tolerances (2 mm or less). Conclusions: In this study, Postal dosimetry audits were performed on the output dose and mechanical accuracy of photon beams (207 beams) for 106 LINACs from 48 institutions. As a result of corrective action and re-execution, it was confirmed that all engines met the acceptable standard within 2 mm in the linear accelerator.

Generation of LiF(Mg,Cu,Na,Si) thermoluminescent crystal and evaluation of dose response and sensitivity

  • Abdollah Khorshidi
    • Nuclear Engineering and Technology
    • /
    • 제56권7호
    • /
    • pp.2790-2798
    • /
    • 2024
  • In this research, thermoluminescent pellets were prepared by adding Mg, Cu, Na and Si impurities to lithium fluoride (LiF) crystal powder via melting and quenching methods to study dosimetric characteristics. Here, its reproducibility, dose response, dosimeter sensitivity, thermal and optical fading were investigated and the obtained results were compared with the properties of LiF: Cu, Mg, P crystal nominated as GR-200.

흉부 X선사진 농도로부터 표면선량을 산출하는 방법 (The Relationship of Overdensity to Overexposure Each Film/screen Systems in Chest Radiography)

  • 김정민;허준;임태랑;석전유치;앵정달야
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제22권1호
    • /
    • pp.13-20
    • /
    • 1999
  • This study is to calculate the exposed radiation dose using Bit method, NDD calculation method and monogram method without dosimeter. In addition, we can calculate the radiation dose from x-ray film density as a film badge. The authors examined the entrance skin dose from $2{\sim}3$ intercostal chest x-ray film density. We also studied the relationship between film density and equivalent dose in the each screen film system under the different radiation quality and the poor geometry condition of grid ratio. As results, we established the deductive method to define the entrance skindose from chest x-ray film density. The error range was found in the range $-13%{\sim}+l7%$ for between deductive entrance skindose and the $2{\sim}3$ intercostal chest x-ray film density to actual detective radiation dose with dosimeter.

  • PDF

Development of Dark-striped Field Mice, Apodemus agrarius, as a Biological Dosimeter in a Radio-ecological Monitoring System 3. Radio-sensitivity between A. agrarius and ICR Mice

  • Kim Hee-sun;Nishimura Y.;Jin Young-Woo;Kim Chong-Soon
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2005년도 춘계 학술대회
    • /
    • pp.513-517
    • /
    • 2005
  • This study examined the possibility of using striped field mice as a biological dosimeter or indicator for the environmental radio-surveillance. For this study, the external morphological characteristics and isoenzymic types of dark-striped field mice were studied after they were captured. Among the morphological external characteristics, the dark-brown coat, dark back stripe, head-to-tail length, tail length, and ear length matched the taxonomical characteristics of dark-striped field mice. The analyses on L-lactate dehydrogenase, aspartate aminotransferase, and malate dehydrogenese revealed that one species of dark-striped field mice, called Apodemus agrarius, was inhabitated throughout a wide range of Korea. On the other hand, A. agrarius and ICR mice to analyze their survival rate and frequency of micronuclei in peripheral polychromatic erythrocytes after irradiation (0, 0.5, 1, 3, 5, 7, 9 Gy). The $LD_{50/30}$ of A. agrarius and ICR mice were approximately 5 Gy and 7Gy, respectively. The results of the study reveal that wild A. agrarius have a high potential as a biological monitoring system to determine the impact of radiation effect in areas such as those within the vicinity of nuclear power plants.

  • PDF

전립선암의 방사선 치료 시 주변 정상장기 피폭선량을 이용한 암발생확률 평가 (Evaluation of Cancer Incidence Rate using Exposure Dose to Surrounding Normal Organs during Radiation Therapy for Prostate Cancer)

  • 이주아
    • 한국방사선학회논문지
    • /
    • 제16권3호
    • /
    • pp.351-356
    • /
    • 2022
  • 전립선암의 방사선치료 시 사용되는 세기조절방사선치료와 부피적회전방사선치료시 발생하는 광중성자선량을 측정하여, 암 발생률을 평가하며 기초자료를 제공하고자 하였다. Rando phantom에 중성자 측정용 광자극발광선량계를 복부와 갑상선에 위치시킨 상태에서 발생하는 광중성자선량을 측정하였다. 연구결과 세기조절방사선치료(7 portal)가 부피적회전방사선치료보다 복부와 갑상선 위치에서 모두 높게 측정되었다. ICRP 103의 명목위험계수를 이용하여 암 발생확률을 평가하였을 때, 세기조절방사선치료시 대장과 갑상선의 피폭으로 인한 암발생확률은 1,000명 당 9.9명 이었으며, 부피적회전방사선치료시는 1,000명 당 3.5명이었다. ALARA(As low as reasonably archievable)원칙에 의거하여 방사선치료계획 수립에 있어서 정상장기들의 피폭선량의 최소화를 위한 가이드라인이 되리라 사료된다.

원전 계획예방정비기간 고피폭 접촉작업에서 방사선작업종사자의 말단선량 평가 현장시험 (A Field Test Assessment on the Extremity Doses of Highly-Exposed Radiation Workers During Maintenance Periods at Nuclear Power Plants in Korea)

  • 김희근;공태영
    • Journal of Radiation Protection and Research
    • /
    • 제35권2호
    • /
    • pp.57-62
    • /
    • 2010
  • 원전 계획예방정비기간 증기발생기 수실작업, 가압기 전열관교체 또는 압력관피더 제거작업 지역 등은 높은 방사선량률을 보이는 지역으로, 짧은 시간 동안의 작업으로 작업종사자는 높은 피폭을 받을 가능성이 있다. 특히, 방사성물질과 접촉하는 손 부위는 높은 피폭이 일어날 수 있다. 이런 점을 고려하여 국내 가압경수로원전과 가압중수로원전의 계획 예방정비기간 중 증기발생기 수실 노즐댐 설치와 제거작업, 원자로 냉각재펌프 보수작업, 원자로헤드 보수 및 검사작업 등과 같은 고피폭 접촉작업에서 방사선작업종사자의 말단선량을 측정하기위한 현장시험을 실시하였다. 여기에 참여한 작업종사자는 가슴과 등 부위에 일상적인 절차에 따른 복수선량계를 패용한 것 이외에 손목에 개인선량계를 추가로 패용하였고, 손가락 부위에는 말단선량계 (Extremity dosimeter)를 패용하였다. 그 결과, 손가락이 받는 등가선량은 각각 손목이 받는 등가선량 및 가슴 또는 등 부위가 받는 등가선량과 일정한 비율로 평가됨을 확인하였다.