• Title/Summary/Keyword: Radiation Dose Enhancement

Search Result 68, Processing Time 0.029 seconds

A Monte Carlo Study of Dose Enhancement with kilovoltage and megavoltage photons (몬테칼로 기법을 이용한 kV, MV X선에서의 선량증가 효과 비교 평가)

  • Hwang, ChulHwan;Im, In-Chul;Kim, Jung-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.87-94
    • /
    • 2017
  • Monte Carlo simulations were used to assess dose enhancement effects for 60-, 90-, 120-, and 150-kV X-rays, and for 6- and 15-MV X-rays. The MCNPX code was used for a computer simulation of the ICRU slab phantom, and gold, gadolinium, and iron oxide (Fe2O3) were employed as dose enhancement agents. In consideration of the buildup region of the incident energy, agent concentrations of 5, 10, 15, and 20 mg/g were inserted on the surface of the phantom at a depth of 5 cm. Based on baseline values obtained in the absence of dose enhancement agents, a quantitative analysis was performed by evaluating depth-dependent changes in the absorbed energy and the dose enhancement factor (DEF). A higher concentration of dose enhancement agents led to a greater dose enhancement effect with iron oxide, gadolinium, and gold in descending order. For kilovoltage (kV) X-rays, as the incident energy was decreased and as the energy became closer to the ionization potential of the atoms in the enhancement agent, the dose enhancement effect increased. In the megavoltage (MV) X-ray range, dose enhancement was higher at 6 MV compared with 15 MV. However, the overall dose enhancements were significantly lower compared to the results obtained with kV X-rays.

Study of radiation exposure on human body using of Computed Tomography (전산화단층촬영 검사 시 인체에 미치는 방사선피폭선량 분석연구)

  • Seon, Jong-Ryoul;Yoo, Se-Jong
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.193-198
    • /
    • 2015
  • This study analyzed the total number of 19,636 patients and radiation technologists, 11,433 of male and 8,203 of female by examined body parts, age, types of detectors, the using contrast enhancement and working condition of the technologists, regular staffs or rotation-duty staffs, based on the K-DOS program distributed by FDA with the DLP value of diagnostic evaluation. The result shows that the effective radiation dose was 0.7mSv~41.7mSv for each region and male patients had more radiation exposure than females. And the amount of exposure was also affected by the types and the method of detectors. Furthermore, the regular staffs took the role of helping the patient to get reduced amount of radiation exposure than rotation duty-staffs. Computed tomography (CT) use has increased dramatically over the past several decades. In this reason, to support the patients and the workers' health in the field, the hospitals should apply specialized regular working radiation technologist system and manufacturing companies of those CTs should develop low medical radiation exposure devices.

Effect of Low-Dose Gamma Radiation to Enhance Germination Rate in Bottle Gourd and Pumpkin Seeds (참박과 호박 종자의 발아촉진을 위한 저선량 감마선의 효과)

  • Kim, Jae-Sung;Baek, Myung-Hwa;Lee, Young-Keun;Lee, Hae-Youn;Yoo, Jun-Cheol
    • Korean Journal of Environmental Agriculture
    • /
    • v.21 no.3
    • /
    • pp.202-207
    • /
    • 2002
  • To establish the seed treatment method of the gamma radiation for germination enhancement of bottle gourd(Lagenaria siceraria Standl.) and pumpkin(Cucurbita ficifolia Bouche), seeds were irradiated with the dose of 1$\sim$20 Gy of the gamma radiation. The germination rate in irradiated group was higher than that of the control, depending on seed condition. In the case of bottle gourd, the germination rate of 70$\sim$80% germinative seed was increased at 4$\sim$20 Gy irradiated groups. Especially, it was the highest at 4 Gy irradiated group. The germination rate of 80$\sim$90% germinative seed was the highest at 4 Gy irradiated group. The germination rate of 70$\sim$80% and 80$\sim$90% germinative seed at 4 days after sowing was increased 66% and 26% at 4 Gy irradiated group, respectively. In the case of pumpkin, the germination rate of 70$\sim$80% and 80$\sim$90% germinative seed was increased at 2 Gy and 8 Gy irradiated group, respectively. Effect of the low-dose gamma radiation on the early growth was enhanced depending on their germination enhancement. Especially, it was the highest at 2 Gy irradiated group of 70$\sim$80% germinative seed of pumpkin. Catalase activity of bottle gourd was increased at 4 Gy irradiated group. Catalase and peroxidase activity of pumpkin were increased at 2 Gy and 8 Gy irradiated group. These results suggest that the germination, early growth and physiological activity of bottle gourd and pumpkin seeds could be promoted by the low dose gamma radiation.

Monte Carlo Calculation on the Dose Modulation Using Dynamic Magnetic Fields for 10 MV X-rays (움직이는 자기장을 이용한 10 MV X-선의 선량변조에 관한 몬테칼로 계산)

  • Kim, Ki Hwan;Oh, Young Kee;Shin, Kyo Chul;Kim, Jhin Kee;Jeong, Dong Hyeok;Kim, Jeung Kee;Cho, Moon June;Kim, Sun Young
    • Progress in Medical Physics
    • /
    • v.18 no.4
    • /
    • pp.221-225
    • /
    • 2007
  • Monte Carlo calculations were performed to demonstrate the dose modulation with dynamic magnetic fields in phantom. The goal of this study is to obtain the uniform dose distributions at a depth region as a target on the central axis of photon beam under moving transverse magnetic field. We have calculated the depth dose curves for two cases of moving magnetic field along a depth line, constant speed and optimal speed. We introduced step-by-step shift and time factor of the position of the electromagnet as an approximations of continuous moving. The optimal time factors as a function of magnetic field position were calculated by least square methods using depth dose data for static magnetic field. We have verified that the flat depth dose is produced by varying the speed of magnetic field as a function of position as a results of Monte Carlo calculations. For 3 T magnetic field, the dose enhancement was 10.1% in comparison to without magnetic field at the center of the target.

  • PDF

Influence of Low Dose Gamma Radiation on the Growth of Maize(Zea mays L.) Varieties (옥수수 생육에 미치는 저선량 감마선 조사효과)

  • Kim, Jae-Sung;Lee, Young-Keun;Park, Hong-Sook;Back, Myung-Hwa;Kim, Dong-Hee
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.4
    • /
    • pp.328-331
    • /
    • 2000
  • Maize (Zea mays L. cv. kosungjaerae and cv. youngwoljaerae) seeds were irradiated with the dose of $0.5{\sim}20$ Gy by $^{60}Co\;{\gamma}-ray$ radiation to investigate the effect of the low dose ${\gamma}-ray$ radiation on the germination rate, early growth and yield. The low dose radiation was able to improve the germination rate and early growth in maize, but the optimal radiation doses were different depended on kinds of cultivars. High stimulatory effect in early growth of maize was observed in 2 Gy irradiation group of kosungjaerae cultivar and in 12 Gy irradiation group of youngwoljaerae cultivar. The optimal radiation dose for the enhancement of yield and yield components in maize was 8 Gy in kosungjaerae cultivar and $4{\sim}12$ Gy in youngwoljaerae cultivar.

  • PDF

Effect of Low Dose of Gamma Radiation on the Growth of Groundnut (Arachis hypogaea L.) (저선량 감마선이 땅콩 생장에 미치는 효과)

  • 김재성;이은경;백명화;박홍숙;김광호
    • Korean Journal of Environmental Biology
    • /
    • v.17 no.3
    • /
    • pp.257-261
    • /
    • 1999
  • Effect of low dose gamma radiation on the growth of groundnut (Arachis hypognea L.) were investigated with respect to germination rate, seedling development and yield. Seeds of “Palpal” cultivar were irradiated with 0.5~20 Gy of ${\gamma}$ radiation in order to determine the hermetic effect of low dose radiation. The germination rate of ${\gamma}$-ray irradiation group was lower than that of the control but the seedling height of groundnut grown from seeds irradiated with low dose ${\gamma}$-ray was slightly higher than that of the control. The number of pod and kernels, and the seed yield increased by 27%, 17% and 19 %, respectively, in the 12.0 Gy irradiation group compared to that in the control group. The 100 seed weight was 87.2 g in the 4.0 Gy irradiation group, which was 11% heavier than 78.3 g in the control group. Low dose radiation showed an enhancement effects on the growth and yield components of groundnut.

  • PDF

An Experimental Study on the Effects of Hyperthermia and Irradiation on the Rat's Kidney (방사선조사와 온열요법이 백서신에 미치는 조직 변화에 관한 실험적 연구)

  • Yoo, Myung-Hee;Lee, Kyung-Ja;Rhee, Chung-Sik
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.157-169
    • /
    • 1989
  • Radiological and clinical evidences indicate that hyperthermia combined with irradiation produce a significant improvement in therapeutic effect of cancer The experiences obtained from 90 rats' kidney A single dose of irradiation ranged from 6Gy, 8Gy and 10Gy was delivered on the rat's kidney. The combined therapy group had the same irradiation after hyperthermia at $42\~44^{\circ}C$ for 30 minutes. Microscopic examination and calculation of thermal enhancement ratio were carried out, and the results were as follows: 1. In the group of hyperthermia alone, there were moderate glomerular congestion and mild tubular degeneration on light microscopic examination. 2. In the group of irradiation alone, tubular degeneration was noted in 6Gy irradiation and its severity was increased along with radiation dose. 3. In the group of hyperthermia combined with irradiation, tubular degeneration and necrosis were appeared in 6Gy and 10Gy irradiation, respectively. 4. On electron microscopic examination, proximal convoluted tubular and glomerular changes in irradiation group were similar to that of combined with hyperthermia, and its severity was increased along with observation periods. 5. Thermal enhancement ratio (TER) was 1.0 after evaluation of histipathologic changes in rat's kidney, with combination therapy.

  • PDF

The Modulation of Radiosensitivity by Combined Treatment of Selective COX-2 Inhibitor, NS 398 and EGF Receptor Blocker AG 1478 in HeLa Cell Line (선택적 COX-2 억제제 NS 398과 EGF 수용체 차단제 AG 1478의 복합투여가 HeLa 세포주의 방사선 감수성에 미치는 영향)

  • Youn Seon Min;Oh Young Kee;Kim Joo Heon;Park Mi Ja;Seong In Ock;Kang Kimun;Chai Gyuyong
    • Radiation Oncology Journal
    • /
    • v.23 no.1
    • /
    • pp.51-60
    • /
    • 2005
  • Purpose : Selective inhibition of multiple molecular targets may improve the antitumor activity of radiation. Two specific inhibitors of selective cyclooxygenase-2 (COX-2) and epidermal growth factor receptor (EGFR) were combined with radiation on the HeLa cell line. To investigate cooperative mechanism with selective COX-2 inhibitor and EGFR blocker, in vitro experiments were done. Materials and Methods : Antitumor effect was obtained by growth inhibition and apoptosis analysis by annexin V-Flous method. Radiation modulation effects were determined by the clonogenic cell survival assay. Surviving fractions at 2 Gy ($SF_2$) and dose enhancement ratio at a surviving fraction of 0.25 were evaluated. To investigate the mechanism of the modulation of radiosensitivity, the cell cycle analyses were done by flow cytometry. The bcl-2 and bax expressions were analyzed by western blot. Results : A cooperative effect were observed on the apoptosis of the HeLa ceil line when combination of the two drugs, AG 1478 and NS 398 with radiation at the lowest doses, apoptosis of $22.70\%$ compare with combination of the one drug with radiation, apoptosis of $8.49\%$. In cell cycle analysis, accumulation of cell on $G_0/G_l$ phase and decrement of S phase fraction was observed from 24 hours to 72 hours after treatment with radiation, AG 1478 and NS 398. The combination of NS 398 and AG 1478 enhanced radiosensitivity on a concentration-dependent manner in HeLa cells with dose enhancement ratios of 3.00 and $SF_2$ of 0.12 but the combination of one drug with radiation was not enhanced radlosensitivity with dose enhancement ratios of 1.12 and SF2 of 0.68 (p=0.005). The expression levels of bcl-2 and bax were reduced when combined with AG 1478 and NS 398. Conclusion : Our results indicate that the selective COX-2 inhibitor and EGFR blocker combined with radiation have potential additive or cooperative effects on radiation treatment and may act through various mechanisms including direct inhibition of tumor cell proliferation, suppression of tumor cell cycle progression and inhibition of anti-apoptotic proteins.

General Radiography Imaging Usage and Effective Dose of Inpatients: Based on Data from Inpatients in 2018 (입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터)

  • Jong-Won Gil
    • Journal of radiological science and technology
    • /
    • v.47 no.2
    • /
    • pp.107-116
    • /
    • 2024
  • In this study, we analyzed the use of general radiography imaging and effective dose in inpatients. Our aim is to help reduce national medical radiation exposure doses and develop rational health-care financial policies. The effective dose for each general radiography was calculated using the ALARA-GR program for 53 types (total: 260 codes) general radiography codes selected from 'National Health Insurance Care Benefit Cost'. The usage of general radiography was analyzed in the 2018 inpatient patient data of the Health Insurance Review and Assessment Service, and the effective dose for each general radiography was analyzed. 89.00% of inpatients undergo general radiography imaging at least once, with an average of 12.63 scans per person and an effective dose of 1.00 mSv. Those who received support from Medical Aid showed a higher value compared to those who were insured by National Health Insurance, with 17.39 cases and 1.43 mSv (p<.001). Chest had the highest usage rate at 23.12% for general radiography imaging, while L-spine had the highest effective dose at 24.53%. It is estimated that 420 inpatients patients undergo 121 to 820 general radiography imaging procedures per year, and 233 inpatients are estimated to have an annual effective dose of >20.00~58.25 mSv. Rational use of health-care finances and the practice of medical radiation safety management are essential for the well-being of individuals, the enhancement of quality of life, and the improvement of health-care quality.

A Study on Gamma ray effects on Stress Response and Cellular Toxicity using Bacterial Cells

  • Min, Ji-Ho;Lee, Hyeon-Ju;Lee, Chang-U;Gu, Man-Bok
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.187-190
    • /
    • 2000
  • Effects of gamma ionizing radiation on recombinant Escherichia coli cells containing stress promoters, recA, fabA, grpE, or katG, fused to luxCDABE originated from Vibrio fischeri were characterized by monitoring transcriptional responses reflected by bioluminescent output. Quantification of gamma-ray intensity may be possible using the recA and fabA promoter fusion since a linear enhancement of bioluminescence emission with increasing gamma-ray intensity was observed. Other strains sensitive to either oxidative stress (DPD2511, katG::luxCDABE) or protein-damaging stress (TV1061, grpE::luxCDABE) were also irradiated by gamma-rays, and resulted in no noticeable bioluminescent output while DPD2794 with recA promoter and DPD2540 with fabA promoter irradiated by the same intensities of gamma-rays gave a significant bioluminescent output. This indicates that the main stresses in the recombinant bacteria caused by ionizing radiation are DNA and membrane-damage, not protein- or oxidative-damage. In addition, in this study, to investigate the relationship between the radiation dose rate and bacterial responses, two recombinant Escherichia coli strains, DPD2794 and GC2, containing lac promoter fused to luxCDABE originating from Photorhapdus luminescences, were used for detecting DNA damage and cellular toxicity under various radiation dose rates. Throughout this study, it was found that these bacteria showed quantitative stress responses to DNA damage and general toxicity caused by gamma rays, depending on the radiation dose rates, indicating that the bacterial stress responses and general toxicity were seriously influenced according to radiation dose rates.

  • PDF