• 제목/요약/키워드: Radiation Counter

검색결과 133건 처리시간 0.019초

서해안 안흥에서 관측된 에어로솔의 농도 변화 및 크기분포 특성 (Characteristics of Aerosol Mass Concentrations and Size Distribution Measured at Anheung, Korea)

  • 이권호;이규태;김정호;문관호;안준모
    • 한국대기환경학회지
    • /
    • 제34권5호
    • /
    • pp.677-686
    • /
    • 2018
  • An intensive measurement was conducted to study the mass and number concentrations of atmospheric aerosols in Anheung ($36.679^{\circ}N$, $126.186^{\circ}E$), the west coastal measurement site of Korea during December 2017~April 2018. To evaluate relationships between the aerosols and meteorological parameters, comparisons of Optical Particle Counter (OPC) measured data and Auto Weather System (AWS) data were performed. Measured PM mass concentrations are $PM_{10}=42.814{\pm}30.103{\mu}g/m^3$, $PM_{2.5}=29.674{\pm}25.063{\mu}g/m^3$, $PM_1=28.958{\pm}24.658{\mu}g/m^3$, respectively. The PM ratios showed that the $PM_{10}$ concentrations contained about 67.8% of $PM_{2.5}$, while most part of $PM_{2.5}$ was $PM_1$ (about 97.1%). Timely collocation with AWS data were performed, exploring relations with the PM concentrations. PM concentrations can be explained by wind direction and relative humidity conditions. The significant reductions of fine particles in mass and number concentrations may attribute to actions on particle growth and wet removal. In these results, we suppose that the aerosol concentrations and size distributions are affected by inflow direction and air mass sources from the origin.

Determination of Microdosimetric Quantities of Several Neutron Calibration Fields at KAERI

  • Kim, B.H.;Kim, J.S.;Kim, J.L.;Chang, S.Y.;Cho, G.;McDonald, J.C.
    • Journal of Radiation Protection and Research
    • /
    • 제28권4호
    • /
    • pp.327-335
    • /
    • 2003
  • The commercially available neutron survey meter, the REM500, which uses a tissue equivalent proportional counter (TEPC) and the self-constructed TEPC were used to determine the microdosimetric quantities of several neutron calibration fields at Korea Atomic Energy Research Institute (KAERI). Microdosimetric spectra, absorbed dose, dose equivalent as well as quality factor were derived and compared with several neutron fields which were produced by using the shadow objects to make neutron scattered and being used as a kind of realistic neutron calibration fields at KAERI. The response of REM500 as a function of mean energy was evaluated with these neutron fields using the counts measured and the predetermined reference value. The response of the self-made TEPC and the REM500 was compared using one of the neutron calibration filelds of a $^{252}Cf$ source. The reference quantities of scattered neutron calibration fields were determined using a Bonner Sphere (BS). The value of frequency-mean lineal energy, dose-mean lineal energy and quality factor of two $^{252}Cf$ sources (unmoderated and $D_2O$ moderated) were determined to check the differences in the reference neutron fields between KAERI and Pacific Northwest National Laboratory (PNNL, USA) and the results were in good agreement within 1%. It means that there is no big difference in dosimetric quantifies of neutron calibration fields of two laboratories.

Analysis of Trends in Dose through Evaluation of Spatial Dose Rate and Surface Contamination in Radiation-Controlled Area and Personal Exposed Dose of Radiation Worker at the Korea Institute of Radiological and Medical Sciences (KIRAMS)

  • Lee, Bu Hyung;Kim, Sung Ho;Kwon, Soo Il;Kim, Jae Seok;Kim, Gi-sub;Park, Min Seok;Park, Seungwoo;Jung, Haijo
    • 한국의학물리학회지:의학물리
    • /
    • 제27권3호
    • /
    • pp.146-155
    • /
    • 2016
  • As the probability of exposure to radiation increases due to an increase in the use of radioisotopes and radiation generators, the importance of a radiation safety management field is being highlighted. We intend to help radiation workers with exposure management by identifying the degree of radiation exposure and contamination to determine an efficient method of radiation safety management. The personal exposure doses of the radiation workers at the Korea Institute of Radiological & Medical Sciences measured every quarter during a five-year period from Jan. 1, 2011 till Dec. 31, 2015 were analyzed using a TLD (thermoluminescence dosimeter). The spatial dose rates of radiation-controlled areas were measured using a portable radioscope, and the level of surface contamination was measured at weekly intervals using a piece of smear paper and a low background alpha/beta counter. Though the averages of the depth doses and the surface doses in 2012 increased from those in 2011 by about 14%, the averages were shown to have decreased every year after that. The exposure dose of 27 mSv in 2012 increased from that in 2011 in radiopharmaceutical laboratories and, in the case of the spatial dose rate, the rate of decrease in 2012 was shown to be similar to the annual trend of the whole institute. In the case of the surface contamination level, as the remaining radiation-controlled area with the exception of the I-131 treatment ward showed a low value less than $1.0kBq/m^2$, the annual trend of the I-131 treatment ward was shown to be similar to that of the entire institute. In conclusion, continuous attention should be paid to dose monitoring of the radiation-controlled areas where unsealed sources are handled and the workers therein.

Jaw tracking을 이용한 다발성 뇌 전이의 용적세기조절회전치료에 대한 유용성 평가 (Evaluation of the Usefulness for VMAT of multiple brain metastasis using jaw tracking)

  • 김태원;유순미;전수동;윤인하;백금문
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.73-81
    • /
    • 2018
  • 목 적 : 다발성 뇌 전이의 방사선치료 시 jaw tracking(JT)과 fixed jawFJ)를 이용한 용적세기조절회전치료(Volumetric Modulated Arc Therapy, VMAT)를 비교하고 유용성을 평가하고자 한다. 대상 및 방법 : JT를 이용하여 치료받은 다발성 뇌 전이(Multiple Brain Metastasis) 환자 중 6개 이상의 종양이 있고 조사면 크기가 $14{\times}14cm^2$ 이상인 환자 10명을 대상으로 하였다. Eclipse(Ver 13.6 Varian, USA)로 JT와 FJ의 전산화치료계획을 각각 수립하였으며, 전자포털영상장치(Electronic Portal Imaging Device, EPID)를 이용하여 감마지수(Gamma Index, 3 mm, 3 %, 95 % 신뢰구간) 및 최대선량차이(Max. Dose Difference)를 측정하였다. 또한 손상위험장기(Organ At Risk, OAR)의 $D_{max}$$D_{mean}$을 산출하고 비교하였으며 처방선량지수(Conformity Index, CI), 선량균질지수(Homogeneity Index, HI)를 평가하였다. 결 과 : JT와 FJ의 측정값을 평가한 감마지수는 모든 Case에서 허용 기준(3 mm, 3 %, 95 % 신뢰구간)에 충족하였으며, 최대선량차이값은 Leaf End Transmission이 발생하는 영역에서 시계방향(Clockwise, CW)은 최대 98.4 %, 평균 43.6 %, 반시계방향(Counter-Clockwise, CCW)은 최대 67.9 %, 평균 41.0 %로 측정되었다. 손상위험장기는 JT를 사용하였을 때 각 정상장기에 대한 $D_{max}$의 최대값은 15.36 %~74.59 %, 평균값은 2.84 %~39.80 % 감소, $D_{mean}$의 최대값은 27.90 %~65.23 %, 평균값은 7.70 %~41.71 %로 감소하였으며, 처방선량지수와 선량균질지수값은 차이가 없었다. 결 론 : 다발성 뇌 전이에서 VMAT으로 치료할 경우 JT를 이용하면 치료계획용적(Planning Target Volume, PTV)의 선량분포에 영향을 미치지 않으면서 불특정 영역에서 발생하는 방사선의 누설 및 투과로 인한 불필요한 피폭을 감소시키고 정상장기에 더 낮은 선량으로 방사선치료가 가능할 것으로 사료된다.

  • PDF

교통신호의 자동최적점제어를 위한 마이크로파 FM-CW 검지계통에 관한 연구 (A Study on Microwave-FM-CW Detection System for the Sutomatic Optimal Point Traffic Control)

  • 양흥석;김호윤
    • 전기의세계
    • /
    • 제22권1호
    • /
    • pp.35-41
    • /
    • 1973
  • An automatic point traffic control method is recommended for more idealistic traffic flow over coarse road netowrks. The automatic control apparatus recommended, consists of a transceiver, amplifier, digital-to-analog converter, signal light controller for emergency and steady state, and digital counter as monitor. The transmitter sends a signal to the target vy means of Microwave-FM-CW and a diode detector picks up the echo signal. Thus the operation of the entire system will be carried out through an open loop state. Some factors necessary for an ideal detector system are rapid response, longevity and stability. An analytical method of the Doppler effect substitutes the conventional frequency deviation into the amplitude of detector output. The changing rate of amplitude is proportional to the voltage of the detector output. Some induced formula from Maxwell's radiation field theory ensures this new method, and, new method, and proves the fact with an experimental data presentation. Stability depends upon Klystron as an oscillator and a diode as a detector. the transceiver installation affects on the response and sensitivity of the system. In accordance with the detector output, several targets are easily classified by amplitudes on the scope. The traffic flow, i.e., target movement which is analyzed by the amplitude method, is shown through the scope and indicates it on the digital counter. The best efficiency for the amplitude analysis can be attained through use of an antenna having the highest sensitivity.

  • PDF

마이크로 도시메트리용 다분할 조직등가비례계수기의 개발과 특성 평가 (Development and Characterization of Multi-Segmented Tissue Equivalent Proportional Counter for Microdosimetry)

  • 남욱원;박원기;이재진;표정현;문봉곤;문명국;임창휘;이수현;김성환
    • 센서학회지
    • /
    • 제24권2호
    • /
    • pp.101-106
    • /
    • 2015
  • We designed, developed and characterized a multi-segmented tissue equivalent proportional (TEPC) counter for microdosimetry. The energy resolution of the multi-segmented TEPC was about 12% for $^{241}Am$ 5.45 MeV alpha particles. The resolution was better than 33% for a single un-segmented TEPC. A compact and low power consumption TEPC could be made by using digital pulse processor (DPP). We also successfully calibrated the TEPC by using $^{252}Cf$ standard neutron source in Korea Research Institute of Standards and Science (KRISS). According to the results, the TEPC is useful for several application of radiation monitoring such as a neutron monitor, air crew monitor and space dosimeter.

Virtual calibration of whole-body counters to consider the size dependency of counting efficiency using Monte Carlo simulations

  • Park, MinSeok;Kim, Han Sung;Yoo, Jaeryong;Kim, Chan Hyeong;Jang, Won Il;Park, Sunhoo
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.4122-4129
    • /
    • 2021
  • The counting efficiencies obtained using anthropomorphic physical phantoms are generally used in whole-body counting measurements to determine the level of internal contamination in the body. Geometrical discrepancies between phantoms and measured individuals affect the counting efficiency, and thus, considering individual physical characteristics is crucial to improve the accuracy of activity estimates. In the present study, the counting efficiencies of whole-body counting measurements were calculated considering individual physical characteristics by employing Monte Carlo simulation for calibration. The NaI(Tl)-based stand-up and HPGe-based bed type commercial whole-body counters were used for calculating the counting efficiencies. The counting efficiencies were obtained from 19 computational phantoms representing various shapes and sizes of the measured individuals. The discrepancies in the counting efficiencies obtained using the computational and physical phantoms range from 2% to 33%, and the results indicate that the counting efficiency depends on the size of the measured individual. Taking into account the body size, the equations for estimating the counting efficiencies were derived from the relationship between the counting efficiencies and the body-build index of the subject. These equations can aid in minimizing the size dependency of the counting efficiency and provide more accurate measurements of internal contamination in whole-body counting measurements.

복수 대역 감지 적외선 센서를 이용한 항공기와 플레어의 열원 식별 기술 (Heat Source Identification Technique of Aircraft and Flare using 2-color Detectable Infrared Sensors)

  • 이동시;이기근
    • 전기학회논문지
    • /
    • 제64권7호
    • /
    • pp.1031-1039
    • /
    • 2015
  • Present guided missiles are equipped with infrared seeker to find the infrared sources radiating from target plane and then chase, which results in an improvement of the hitting success rate when in striking target objects. To interrupt the chases from the guided missile, the target plane spreads the flare, avoiding the missile attracts. Our research is to develop a 2-color infrared identification technique to discern the flare and real thermal source from target plane. Considering flare radiation properties and EM atmosphere transmission rates, two channels were selected, in which main channel (MC) was in a range of 3.7 μm∼4.8 μm and auxiliary channel (AC) in 1.7 μm∼2.3 μm. A 2500K heat source was used for an artificial flare source, while a 570K heat source was utilized for airplane infrared source in experimental testing. Two infrared sensors detectable only at each chanel were employed in order to measure the voltage ratio from two channels, identifying the flare and real target plane via comparison the voltage ratio. Several experimental conditions were imported in order to prove that our proposed 2-color infrared identification technique is very efficient way to discern heat sources from aircraft and flare, demonstrating that our proposed technique is very promising means for our force’s InfraRed Counter Counter Measure (IRCCM) in order to countermeasure opposite force’s InfraRed Counter Measures (IRCM).

252Cf 중성자장에서 열형광선량계(TLD)를 이용한 중성자 방사선량 측정 (Neutron Dose Measurements Using TLDs in a 252Cf Neutron Field)

  • 장인수;김상인;이정일;김장렬;김봉환
    • Journal of Radiation Protection and Research
    • /
    • 제38권1호
    • /
    • pp.37-43
    • /
    • 2013
  • TLD를 이용하여 중성자 선량을 측정할 경우, TLD는 중성자 에너지에 대한 반응도 차이가 크기 때문에 현장 중성자장의 스펙트럼 특성에 맞는 에너지 반응도 보정이 반드시 필요하다. 본 실험에는 소형으로 가공된 TLD 소자를 사용하여 $^{252}Cf$ 중성자장에 설치된 내부구조가 복잡하고 좁은 Long-Counter (중성자 검출기) 내외부에서의 중성자 주위선량당량(ambient dose equivalent)을 측정하였다. 측정결과는 입자수송해석코드(MCNPX)를 이용한 계산결과와 비교하였다. 기존의 TLD 교정 선원인 $D_2O$ 감속 $^{252}Cf$만으로 교정하여 판독한 결과값은 전산모사 계산값과 많은 차이를 보였다. 그러나 bare 및 $D_2O$ 감속 $^{252}Cf$ 선원을 사용하여 생산한 두 교정인자를 혼용한 판독값은 계산값과 비슷하였다. 결과적으로, TLD 소자는 사용 현장과 비슷한 특성을 가지는 중성자장에서 교정되어야지만 올바른 선량평가가 가능함을 확인하였다.

프로토 타입 조직등가비례계수기의 중입자가속기연구소의 135 MeV/u 탄소 이온에 대한 선형에너지 스펙트럼 측정 (Measurement of Linear Energy Spectra for 135 MeV/u Carbon Beams in HIMAC Using Prototype TEPC)

  • 남욱원;이재진;표정현;박원기;문봉곤;임창휘;문명국;하시시 키다무라;신고 고바야시;김성환
    • 센서학회지
    • /
    • 제23권3호
    • /
    • pp.197-201
    • /
    • 2014
  • TEPC (Tissue Equivalent Proportional Counter) was usually used for high LET radiation dosimetry. We developed a prototype TEPC for micro-dosimetry in the range of $0.2{\sim}300 keV/{\mu}m$. And, the simulated site diameter of the TEPC is $2{\mu}m$, of similar size to a cell nucleus. For purposes of characterization the response for high LET radiation of the TEPC has been investigated under 135MeV/u Carbon ions in HIMAC (Heavy Ion Medical Accelerator). We determined the gas multiplication factor and measured the lineal energy spectrum [yd(y)] of 135 MeV/u Carbon ions. The value of the gas multiplication factor was 315 at 700 V bias voltage. As a result of the experiment, we could more understand the performance of the TEPC for high LET (Linear Energy Transfer) radiation. And the procedure of high LET radiation dosimetry using TEPC is established.