• 제목/요약/키워드: Radiant Temperature

검색결과 308건 처리시간 0.022초

대구지역의 하절기 장.단파복사 관측 (Observation of Long and Short Wave Radiation During Summer Season in Daegu Area)

  • 오호엽;최동호;이부용
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.134-139
    • /
    • 2012
  • This study observed downward long and short-wave radiant environment with selecting 4 areas which have different height in downtown and 1 suburban area to figure out the characteristic of radiant environment in each altitude. The purpose of this study is to collect the preliminary data for interpreting urban thermal environment in summer season by analyzing thermal characteristic of atmosphere in the upper of downtown. The results of this study are as follows. 1) The higher altitude has the lower temperature, and temperature difference was more huge in day time than night time. 2) The short wave radiation according to altitude was higher as altitude was high. 3) Generally, the higher altitude has the lower air temperature, and also the higher altitude has the lower downward long wave radiation by the atmospheric radiation. 4) The ratio short wave radiation of long wave radiation was lower as altitude was high. And the urbanization effect was higher as the ratio was low.

  • PDF

소형 축열식 복사관 버너시스템용 축열기 설계 및 성능평가 (Design and Estimation of Performance of Heat Regenerator for Small-scale Regenerative Radiant Tube Burner)

  • 조한창;조길원;이용국
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2004년도 춘계 학술발표회 논문집
    • /
    • pp.171-176
    • /
    • 2004
  • 열처리로에 적용되는 소형 축열식 복사관 버너시스템에 사용될 축열기를 설계하고 그 성능을 평가하였다. 좁은 튜브간 간격을 갖는 U형 복사관에 축열기를 적용하기 위하여 상하단 단면적이 다른 축열기를 설계, 적용하였다. 구형축열체를 사용하는 2만kcal/hr급 축열기 설계에는 기존에 개발된 축열기 해석코드를 이용하였다. 실제 시스템에 적용하여 축열기 전후단의 온도 및 압력을 실시간으로 측정하였다. 그 결과를 축열기 해석코드로부터 얻은 배가스의 배출온도와 공기의 예열온도를 비교하였다. 이론적으로 예상된 성능은 80%의 온도효율과 70%의 배열회수율이 얻어졌으나, 실험적 결과로부터는 온도효율이 80%, 배열회수율이69%가 얻어졌다. 가장 큰 성능 차이는 배가스의 배출온도였는데, 이는 실제 시스템에서 열손실에 의한 축열기로의 배가스 유입온도 하락과 실제 운전에서의 공기/배가스 유량의 증가에 의해 기인된다고 판단된다.

  • PDF

폴리프로필렌 모세유관 냉방시스템의 적용에 관한 실험적 연구 (An Experimental Study on the Application of Polypropylene Capillary Tube Cooling System)

  • 이영주;김오봉;김광우;여명석
    • 설비공학논문집
    • /
    • 제17권9호
    • /
    • pp.873-881
    • /
    • 2005
  • In this study, we made RFC, RCC and NCC according to the method by which polypropylene capillary tube was adopted, and evaluated cooling performance of each system through model experiments. We also investigated an applicability of the combined use of radiant cooling and dehumidification system. The results are as follows: In case of normal cooling load, RFC and RCC maintained set temperature without a condensation. But, in case of peak cooling load, RFC and RCC resulted in the lack of cooling performance and caused a condensation at the radiation surface. Consequently, the only use of polypropylene capillary tube is considered not to be enough for cooling in real application. Using the combination of a dehumidification and radiant cooling system maintained the set temperature without a condensation. NCC kept the set temperature at anytime without a condensation. It is more economic than packaged air-conditioner system due to the cooling effect of the floor surface.

반도체 PR 공정의 클린룸내 CFD 기반 화재 사고 영향 분석 (CFD-based Fire Accident Impact Analysis in Clean Room for semiconductor PR Process)

  • 천광수;이진석;박명남
    • 한국가스학회지
    • /
    • 제25권6호
    • /
    • pp.35-44
    • /
    • 2021
  • 반도체 공정 중 PR (Photo Resist) 공정은 여러 인화성 물질을 혼합하여 사용하는 공정으로, 공정 장비가 Clean Room 내 설치되어 인화성 물질이 누출되는 경우 질식, 화재, 폭발 사고로 이어질 위험성이 크므로, 물질 누출시 발생할 수 있는 사고에 대한 영향을 분석하고, 작업자들의 안전을 보장할 수 있는지 평가하는 것이 필요하다. 본 연구는 FLACS CFD - Fire Module을 이용하여 10개의 누출, 화재 시나리오에 대한 CFD Simulation을 통해 Clean Room 내부 가상으로 설정한 Monitor Point에서의 복사열 및 온도 변화 값을 확인하였다. Clean Room 내부에서 발생한 화재는 층간 구조물에 높은 복사열을 전달하지만, 그 범위가 상당히 제한적이며, 단일 화재 사고로 인해 붕괴될 가능성이 희박하다. 화재 사고로 인해 탈출구로 이어지는 2 곳의 계단이 동시에 높은 복사열에 노출되는 시나리오는 없어, 화재 발생시 작업자가 탈출 가능하였다. 또한 복사열 및 온도 상승의 수준은 아래층으로 이동하면서 급격하게 낮아지는 것을 확인하였으며, API 520의 기준에 따라 작업자가 30초 동안 버틸 수 있는 복사열인 6.31 kW/m2에 노출된 작업자도 화재가 발생한 Clean Room 내부에서 충분히 탈출할 수 있음을 확인하였다.

Innovative Electromagnetic Induction Eddy Current-based Far Infrared Rays Radiant Heater using Soft Switching PWM Inverter with Duty Cycle Control Scheme

  • Tanaka H.;Sadakata H.;Muraoka H.;Okuno A.;Hiraki E.;Nakaoka M.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.64-68
    • /
    • 2001
  • This paper presents an innovative prototype of a new conceptual electromagnetic induction heated type far infrared rays radiant heating appliance using the voltage-fed edge-resonant ZVS-PWM high frequency inverter using IGBTs for food cooking and processing which operates under a constant frequency variable power regulation scheme. This power electronic appliance with soft switching high frequency inverter using IGBTs has attracted special interest from some advantageous viewpoints of safety, cleanliness, compactness and rapid temperature response, which is more suitable for consumer power electronics applications.

  • PDF

도시열섬현상완화를 위한 그린인프라 전략 (Green-infra Strategies for Mitigating Urban Heat Island)

  • 박채연;이동근;권유진;허민주
    • 한국환경복원기술학회지
    • /
    • 제20권5호
    • /
    • pp.67-81
    • /
    • 2017
  • Because of lack of accurate understanding of the mechanism of urban heat island (UHI) phenomenon and lack of scientific discussion, it is hard to come up with effective measures to mitigate UHI phenomenon. This study systematically described the UHI and suggested the solutions using green-infrastructure (green-infra). The factors that control UHI are very diverse: radiant heat flux, latent heat flux, storage heat flux, and artificial heat flux, and the air temperature is formed by the combination effect of radiation, conduction and convection. Green-infra strategies can improve thermal environment by reducing radiant heat flux (the albedo effect, the shade effect), increasing latent heat flux (the evapotranspiration effect), and creating a wind path (cooling air flow). As a result of measurement, green-infra could reduce radiant heat flux as $270W/m^2$ due to shadow effect and produce $170W/m^2$ latent heat flux due to evaporation. Finally, green-infra can be applied differently on the macro(urban) scale and micro scale, therefore, we should plan and design green-infra after the target objects of structures are set.

이중 윅 타입 히트파이프를 이용한 바닥복사패널의 난방특성 연구 (A Study on the Heating Characteristics of Radiant Floor Panel Using Heat Pipes with the Double Wick)

  • 김용기;이태원
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.183-189
    • /
    • 2012
  • Most of the domestic residential buildings have used the traditional radiant heating system, circulating hot water through the cross-linked polyethylene(PE-X) pipe buried in the floor panel of the heating space. New type of the heating panel was recently developed using heat pipes with double wicks. Some experiments were carried out in this study to verify the thermal characteristics of this heating system at the unit heating space which surrounded by outer space whose temperature of air be maintained scheduled value with time. Through the various experiments with several parameters, such as flow rate, inlet and outlet temperatures of hot water and the heating duration and so on, we found that the floor heating system with heat pipes was able to reduce the pumping power for hot water circulation by 4~31% compared with the conventional panel heating system using PE-X pipe. These results could be used for optimal design and efficient operation of the heating system as well as improvement of thermal comfort.

차양장치의 겨울철 천공복사 냉각 저감 효과에 관한 실험적 연구 (An Experimental Study on the Reduction Effects of Shading Devices on Sky Radiant Cooling in Winter)

  • 김진희;김영탁;이수열;최원기
    • 토지주택연구
    • /
    • 제12권1호
    • /
    • pp.129-137
    • /
    • 2021
  • 외부 차양장치는 대표적인 여름철 일사조절 장치이다. 특히 냉방부하가 높은 업무용 건물에 적합한 기술로 인식되어왔다. 그러나 본 연구에서는 차양장치의 냉방부하 저감뿐만 아니라 난방부하 저감 효과를 검증하기 위한 실험을 수행하였다. 이를 위해 겨울철 야간 천공복사냉각에 따른 영향을 중심으로 일반 창호, 롤 블라인드, 외부 차양장치를 대상으로 실험을 수행하였으며, 그 결과는 다음과 같다. 외부 차양장치가 적용된 경우 유리 내·외표면 온도차는 평균 11.8℃로 차양장치가 없는 경우의 14.6℃ 보다 평균 2.8℃ 낮은 온도차를 나타냈으며, 이는 천공복사에 의한 열교환으로 차양 표면온도가 외기온도보다 낮은 시간때에 발생한다. 한편, 롤 블라인드는 내부 중공층의 평균온도보다 0.8℃ 낮은 온도를 나타냈으며 이 또한 투과체를 통과한 천공복사가 롤 블라인드 표면과 열교환이 이뤄졌기 때문이다. 유리 외부 표면온도만을 고려하면 약 3℃ 이상의 온도 상승이 예상된다. 그리고 차양장치가 없는 경우 일반적인 온도구배를 나타내고 있었다. 한편 남동향과 남서향에 외부 차양장치가 설치되었을 때 남서향의 외측 유리 표면온도가 더 낮게 나타나는 특징이 있다. 이 결과는 천공복사에 의한 냉방 저감 효과를 정량화할 수는 없지만 적어도 타당성은 확인할 수 있었다. 향후 연구에서는 천공복사 냉각과 에너지 소비 사이의 상관관계를 조사하고 외부 차양장치의 난방에너지 절감 효과에 대한 독립 챔버 실험을 진행할 계획이다.

소방보호복 소재의 공기간극이 열보호 성능에 미치는 영향 (Effect of Fire Fighters' Turnout Gear Materials Air Gap on Thermal Protective Performance)

  • 이준경;권정숙
    • 한국화재소방학회논문지
    • /
    • 제28권4호
    • /
    • pp.97-103
    • /
    • 2014
  • 소방보호복은 고열유속에 의한 화상방지를 위해 3층 이상의 복합소재로 구성되어 있으며, 각 소재 사이는 공기 간극이 존재한다. 화재에 의한 고열유속 노출 시 공기 간극 내에서의 열전달은 대류와 복사에 의해 주로 발생하며, 그로 인해 간극의 크기에 따라서 비선형 특징의 열 저항 크기를 갖게 된다. 그러므로 본 연구에서는 보호복 소재 사이의 여러 가지 공기 간극(0~7 mm)에 대한 보호복의 열 보호성능을 자세히 파악하기 위한 실험을 수행하였다. 복사 열 유속 입사시에 시간에 따른 각 소재의 온도 변화뿐만 아니라, 열 보호성능을 가장 효과적으로 나타낼 수 있는 지표(Radiant Protective Performance, RPP) 값의 공기간극에 대한 변화 특성을 파악하였다. 공기간극이 증가할수록 단열효과가 커짐으로 인해 후면의 온도는 낮아지고, RPP는 커짐을 확인할 수 있었다. 특히 일정 열유속 조건에서 공기간극에 대한 RPP 값은 선형적인 특성을 나타내었고, 그러한 결과를 바탕으로 다양한 입사 열유속 및 공기 간극 조건에 대해 비교적 간단한 형태의 RPP 지표 예측 식을 제안하였고, 좋은 예측 결과를 얻을 수 있었다.

공동주택 단지 내 식재유형에 따른 온도저감 효과 연구 (A Study on the thermal comfort change according to the Planting Type in housing complex)

  • 문수영;장대희
    • KIEAE Journal
    • /
    • 제12권2호
    • /
    • pp.65-75
    • /
    • 2012
  • The rapid urbanization caused drastic temperature changes in Korea. Excessive urbanization and development result in unpredictable and abnormal climate change all over the world. These changes are reflected in Korean government policy and research about cities, such that various research endeavors have been undergone recently. There are lots of ways to improve the urban environment; the easiest way to solve the urban heat effect problem is to make green spaces within the city. Even though we can't enlarge green spaces over the city limitlessly, it is desperately need for a methodology to efficiently create green space in limited area. Based on awareness of issues as mentioned earlier, we would like to propose landscaping method that can increase thermal comfort in the same area. For this study, simulating the change of temperature, mean radiant temperature, PMV were done due to number of species planted in apartment complex. To increase the reliability of the simulation, first above all, field measurement for temperature change was performed in apartment complex, where residential building are arranged in the form of ㄷ. And based on this data, Envi-met simulation was performed varying 1-7 kinds of species divided by grass, shrubs, arbor (deciduous, conifers) planted in apartment complex. As a result, there was a change less than $1^{\circ}C$ with the increasing number of species in daytime, but the average radiation temperature about $6-7^{\circ}C$ was reduced. In addition, PMV index was improved by more than 0.5 point. Thermal comfort indicator improved significantly depending on the number of species during the day, on the other hand, there were no significant changes at night. As a consequence, this study has shown that not single-species planting but mixed planting varied the number of species would improve the thermal comfort in the same area of landscaping space at daytime.