• Title/Summary/Keyword: Radial flow

Search Result 786, Processing Time 0.027 seconds

A New Load Flow Algorithm based on DAS with Considering Distributed Load (배전자동화 시스템에서 분포부하를 고려한 새로운 조류계산 알고리즘)

  • Yang, Xia;Choi, Myeon-Song;Lim, Il-Hyung;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.169-170
    • /
    • 2006
  • In this paper, A new algorithm for load flow calculation is proposed for radial distribution network. Feeder Remote Terminal Unit (FRTU) is utilized to collect data such as current magnitude and angle of power factor at each node. Proposed algorithm is based on the model of distributed load in distribution system. Load flow calculation is using four terminal constants method.

  • PDF

The Flow of a Liquid Film on Spin Coating (스핀 코팅에서의 액막의 흐름)

  • Kim, Tae-sung
    • Journal of ILASS-Korea
    • /
    • v.18 no.3
    • /
    • pp.146-154
    • /
    • 2013
  • The flow of a liquid film on spin coating is investigated in the case that the fixed volume of a liquid is placed on the center of a stationary disk. Thin film equations that are well approximated when the characteristic length in the vertical direction is much smaller than that in the radial direction (${\varepsilon}{\ll}1$) and have already been proposed in the work of T.-S. Kim & M.-U. Kim (2009), are used. The differential equation that governs the free surface of a liquid when ${\varepsilon}{\ll}1$ and ${\varepsilon}Re{\ll}1$ is also derived. The basic flow is analyzed using the thin film equations and their results are compared to the results of Navier-Stokes equations.

A Theoretical Model of Critical Heat Flux in Flow Boiling at Low Qualities

  • Kim, Ho-Young;Kwon, Hyuk-Sung;Hwang, Dae-Hyun;Kim, Yongchan
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.7
    • /
    • pp.921-930
    • /
    • 2001
  • A new theoretical critical heat flux (CHF) model was developed for the forced convective flow boiling at high pressure, high mass velocity, and low quality. The present model for an intermittent vapor blanket was basically derived from the sublayer dryout theory without including any empirical constant. The vapor blanket velocity was estimated by an axial force balance, and the thickness of vapor blanket was determined by a radial force balance for the Marangoni force and lift force. Based on the comparison of the predicted CHF with the experimental data taken from previous studies, the present CHF model showed satisfactory results with reasonable accuracy.

  • PDF

Turbulence Structures of Flow in Concentric Annuli with Rough Outer Wall (외벽에 거칠기가 있는 이중동심관 유동의 난류구조)

  • 김경천;안수환;이병규
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.9
    • /
    • pp.2443-2453
    • /
    • 1994
  • The structure of turbulence of fully developed flow through four concentric annuli with the rough outer wall was investigated experimentally for a Reynolds number range Re=15, 000-93, 000. Turbulence intensities were measured in three(u, v, w) directions, and turbulence shear stresses in annuli of radius=0.13, 0.26, 0.4 and 0.56, respectively. Due to the square roughness element attached periodically along the axial direction, the radial velocity fluctuations show similar distribution regardless of the different .alpha.cases. However, the axial and circumferential velocity fluctuation profiles demonstrate the longitudinal turbulence structures are strongly influenced by the .alpha. values. The turbulent eddy viscosity deduced form mean velocity distributions and the measured Reynolds shear stresses are also presented and discussed.

Two-Dimensional Analysis of Pressure Distribute by Underwater Electric Discharge (수중방전에 의한 압력분포의 2차원 해석)

  • Kim, Y.S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.1
    • /
    • pp.68-77
    • /
    • 1995
  • The two-dimensional pressure distribution, which is the most important parameter in the casting cleaning installations(CCI), was analyzed using the K-FIX computer program for two-phase flow. Modelling was done using R-Z coordinates for the initial and boundary conditions which don't have periodic influx and efflux, and also there was the electric discharge due to high pressure and temperature. The marked particles were introduced to prodict the structure and the size of main and local moving surfaces. The initial and boundary conditions were modified due to the internal structure of CCI.From the results of numerical analysis, it was shown that the maximum pressure on casting was increased with the increase of a water level. The pressure on casting in the radial direction was higher than that in axial direction. Also, it was proved that by introducing the marked particles it was possible to predict the surface structure in case of two-phase flow.

  • PDF

Critical Fluid Velocity of Fluid-conveying Cantilevered Cylindrical Shells with Intermediate Support (중간 지지된 유체 유동 외팔형 원통셸의 임계유속)

  • Kim, Young-Wann
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.5
    • /
    • pp.422-429
    • /
    • 2011
  • The critical fluid velocity of cantilevered cylindrical shells subjected to internal fluid flow is investigated in this study. The fluid-structure interaction is considered in the analysis. The cantilevered cylindrical shell is supported intermediately at an arbitrary axial position. The intermediate support is simulated by two types of artificial springs: translational and rotational spring. It is assumed that the artificial springs are placed continuously and uniformly on the middle surface of an intermediate support along the circumferential direction. The steady flow of fluid is described by the classical potential flow theory. The motion of shell is represented by the first order shear deformation theory (FSDT) to account for rotary inertia and transverse shear strains. The effect of internal fluid can be considered by imposing a relation between the fluid pressure and the radial displacement of the structure at the interface. Numerical examples are presented and compared with existing results.

Numerical study for downburst wind and its load on high-rise building

  • Huang, Guoqing;Liu, Weizhan;Zhou, Qiang;Yan, Zhitao;Zuo, Delong
    • Wind and Structures
    • /
    • v.27 no.2
    • /
    • pp.89-100
    • /
    • 2018
  • 3D simulations based on an impinging jet were carried out to investigate the flow field of a steady downburst and its effects on a high-rise building by applying the SST k-${\omega}$ turbulence model. The vertical profile of radial wind speed obtained from the simulation was compared with experimental data and empirical models in order to validate the accuracy of the present numerical method. Then wind profiles and the influence of jet velocity and jet height were investigated. Focusing on a high-rise building, the flow structures around the building, pressure distributions on the building surfaces and aerodynamic forces were analyzed in order to enhance the understanding of wind load characteristics on a high-rise building immersed in a downburst.

A COMPUTATIONAL STUDY ON PERFORMANCE OF THE DENTAL AIR MOTOR HAND-PIECE USING MOVING MESH METHOD (무빙메시를 이용한 치과 치료기기용 에어모터 핸드피스의 선응에 관한 수치해석적 연구)

  • Sung, Y.J.;Ryu, K.J.;Song, D.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.572-578
    • /
    • 2011
  • The vane type air-motor hand-piece is used widely in the dental services. There are a lot of experimental studies about air-motor but eccentrically off not many numerical studies by using Computational Fluid Dynamics. An air-motor has rotor which rotates at the center of inner housing. The retractable vanes are installed on the rotor. As the rotor of the air-motor rotates, vanes move up and down straightly in the radial direction along the guide. Therefore we have to analyze the unsteady flow field by accurate time dependent marching technique. ANSYS 12.0 CFX is used to analyze unsteady vane-motor flow field Analysis of the changing control volume inside air-motor is implemented by user-defined functions and moving mesh options. Rotational speed of the rotor is approximately 23,000rpm.

  • PDF

Numerical analysis in oscillating flow considering orientation of porous media regenerator (다공성 재생기의 방향성을 고려한 왕복유동 수치해석)

  • Yang, Mun-Heum;Park, Sang-Jin;No, Seung-Tak
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.12
    • /
    • pp.1668-1678
    • /
    • 1997
  • Numerical analyses were performed to investigate the characteristics of regenerator in oscillating flow by using moving boundary method and Darcy model. In this work, periodic adiabatic boundary condition was suggested as the boundary condition of adiabatic part so that the effects of the thermal inertia of the wall could be considered. In carrying out numerical analyses, two models were applied and compared. One called isotropic model has the same thermal conductivity in radial and axial directions within a porous media. The other called aeolotropic model has different conductivity in each directions. Isotropic model could not show the advantage of energy reduction which needs to maintain constant wall temperature difference between heater and cooler. But aeolotropic model could simulate the reduction of energy consumption.

Behavior Characteristics of Swirl-Twin Spray with Changing Swirl Angle (선회각도변화에 따른 2유체 선회분무의 거동특성)

  • Kang, Wan-Bong;Cha, Keun-Jong;Kim, Duck-Jool
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.943-948
    • /
    • 2000
  • The Twin-fluid Swirl Nozzles are used in many parts of the industry to produce homogeneous spray. This study is to investigate the effects of outer air swiller and inner water swiller on atomization of liquid.. The experiment was carried out with increasing air-flow rate at constant liquid-flow rate and with changing outer air swiller angle and inner water swiller angle. A Particle Dynamics Analyzer(PDA) was used to measure drop size, mean and ms values of axial velocity, number density and Sauter mean diameter(SMD). The axial mean velocity and SMD of droplets were measured along the center line and radial directions. It was found that the higher air flow-rate resulted in the smaller Sauter mean diameter of liquid spray and the higher axial mean velocity of droplets. This experimental results will be conveniently used for the preliminary design stage of twin-fluid nozzle development.

  • PDF