• Title/Summary/Keyword: Radial Parameters

Search Result 566, Processing Time 0.027 seconds

Analysis of Radial Air-shear Force on Magnetic Disks for Reducing the Spin-off of Lubricants

  • Kurita, M.;Shimizu, H.;Mizumoto, M.;Ootani, Y.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.281-282
    • /
    • 2002
  • To reduce the spin-off of lubricants on a magnetic disk, which is caused by the radial component of shear force between the disk and air, we analyzed the air-velocity distribution and the air-shear force by three-dimensional large-eddy simulation (LES). This sensitivity analysis, on five design parameters, showed that disk/arm clearance and arm thickness have a greater effect on the mean radial air-shear force than the other parameters. The force on a disk optimized according to the optimum parameters is 12% less than the force on a conventional disk.

  • PDF

Bifurcation Behaviours of Composite Tubes With Two Different Materials Subjected To Uniform Radial Shrinkage At The External Surface (외주에 균일한 압축을 받는 두꺼운 복합원관의 분지거동)

  • ;;Tomita,Y.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.2
    • /
    • pp.269-275
    • /
    • 1990
  • Nonaxisymmetric bifurcation behaviours of composite tubes two different materials subjected to uniform radial shrinkage at the external surface have been investigated and compared with those of single tube. The effect of material parameters normalized with respect to those of outer tube upon the bifurcation point and corresponding mode has been clarified. The parameters substantially affect the bifurcation mode with long-wavelength so that the composite tube with low hardening exponent or with high yield stress of inner tube destabilizes the overall deformation of the tube. However surface type bifurcation, short-wavelength mode, shown on the traction-free inner surface is hardly affected by the material parameters. The surface type bifurcation completely depends on the material characteristics of inner tube and the bifurcation point of composite tube almost coincides with the of single tube.

A Study on Tire Radial Force Variation and Modal Testing (타이어 상하 힘변동과 모드 시험에 관한 연구)

  • Park, S.K.;Kim, J.K.;Song, S.K.
    • Journal of Power System Engineering
    • /
    • v.2 no.3
    • /
    • pp.55-59
    • /
    • 1998
  • This paper probes into the influence of tire uniformity on tire's modal parameters with the method of experimental modal analysis. Two radial tires of the same kind with different uniformity level are taken to be tested at different exciting points and real modal parameters are abstracted. The differences of their modal parameters are presented. Then tire transfer functions are constructed with experimental modal parameters and ideal modal parameters respectively. It is found that the measured transfer functions of tire of good uniformity are closer to ideal transfer function than that of tire of bad uniformity. The study shows evident interrelation of experimental modal parameters and tire uniformity, and further study should be of great value.

  • PDF

Effect of Sa-Am Acupuncture on Radial Pulse ; A Comparative Study of Stomach-tonification and Spleen-tonification (위정격(胃正格)및 비정격(脾正格)자침이 맥파에 미치는 영향 비교 연구)

  • Yim, Yun-Kyoung;Lee, Hyun;Lee, Byung-Ryul;Lee, Yong-Heum;Yoon, Young-Jun;Ro, Jee-Yong
    • Korean Journal of Acupuncture
    • /
    • v.28 no.3
    • /
    • pp.25-32
    • /
    • 2011
  • Objectives : The purpose of this study is to find parameters to compare the effects of Sa-Am acupuncture with stomach-tonification (ST) and Sa-Am acupuncture with spleen-tonification (SP) on radial pulse. Methods : Forty healthy subjects participated in this study. Radial pulse was measured using 3 dimensional pulse imaging system (DMP-3000) before, right after, 30 minutes after, and 60 minutes after acupuncture. Results : 1. The parameters analysed in this study were changed in the same direction with different degrees by ST and SP. 2. In males, SP manipulation showed significantly increased pulse period and (T-T4)/T, and significantly decreased T1/T, T4/T, T4/(T-T4), and F1~F3 frequencies compared to ST. 3. In females, ST manipulation showed significantly increased (T-T4)/T, and significantly decreased F1~F3 frequencies compared to SP. Conclusions : The parameters analysed in this study may be used to differentiate the effects between ST and SP on radial pulse. These parameters are more strongly affected by SP than ST in males whereas more strongly affected by ST than SP in females.

Effects of Double Volute on Performance of A Centrifugal Pump (원심펌프의 성능에 대한 더블 볼류트의 영향)

  • Shim, Hyeon-Seok;Heo, Man-Woong;Kim, Kwang-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.1
    • /
    • pp.37-44
    • /
    • 2016
  • In this study, a parametric study of a centrifugal pump with double volute has been performed numerically using three-dimensional Reynolds-averaged Navier-Stokes equations. The shear stress transport model was selected as turbulence closure through turbulence model test. The finite volume method and unstructured grid system were used for the numerical analysis. The optimal grid system in the computational domain was determined through a grid dependency test. The expansion coefficient, circumferential and radial starting positions and length of divider were selected as the geometric parameters to be tested. And, the hydraulic efficiency and the radial thrust coefficient were considered as performance parameters. It was found that the radial thrust and hydrualic efficiency are more sensitive to the expansion angle and circumferential starting position of the divider than the other geometrical parameters.

Numerical Investigation on Hydrodynamic Characteristics of a Centrifugal Pump with a Double Volute at Off-Design Conditions

  • Shim, Hyeon-Seok;Kim, Kwang-Yong
    • International Journal of Fluid Machinery and Systems
    • /
    • v.10 no.3
    • /
    • pp.218-226
    • /
    • 2017
  • Severe radial thrust under off-design operating conditions can be a harmful factor for centrifugal pumps. In the present work, effects of geometry of a double volute casing on the hydrodynamic performance of a centrifugal pump have been investigated focusing on off-design conditions. Three-dimensional steady Reynolds-averaged Navier-Stokes analysis was carried out by using shear stress transport turbulence model. Numerical results for the hydrodynamic performance of the centrifugal pump were validated compared with experimental data. The hydraulic efficiency and radial thrust coefficient were used as performance parameters to evaluate the hydrodynamic characteristics of the centrifugal pump. The cross-sectional area ratio of the volute casing, the expansion coefficient of the rib structure, the distance between the rib starting point and volute entrance, and radius and width of the volute entrance, and length of the rib structure, were selected as geometric parameters. Results of the parametric study show that the performance parameters are significantly affected by the geometric variables and operating conditions. Optimal configurations of the double volute casing based on the design of experiments technique show outstanding performance in terms of the efficiency and radial thrust coefficient.

The Effects of Sa-Am Acupuncture on Radial Pulse in Healthy Subjects: A Comparative Study of Large Intestine Tonifying and Sedating (대장정격 및 승격 자침이 정상 성인의 맥파에 미치는 영향 비교 연구)

  • Cho, Eun;Lee, Hyun
    • Journal of Acupuncture Research
    • /
    • v.31 no.3
    • /
    • pp.7-18
    • /
    • 2014
  • Objectives : The purpose of this study is to find parameters to compare the effects of Sa-Am acupuncture with large intestine tonifying and sedating on radial pulse in healthy subjects. Methods : Sixty healthy subjects participated in this study, divided into large intestine tonifying acupuncture group, large intestine sedating acupuncture group and control group. Radial pulse was measured by 3 dimensional pulse imaging system(DMP-3000) before, right after, 30 minutes after and 60 minutes after acupuncture at Cun, Guan, and Chi in the acupuncture group and in the control group at the same time points. Results : 1. Angle of main peak and magnitude of fourier component significantly changed by integrated analysis of Cun, Guan and Chi. 2. Amplitude of H1, Pulse Power volume / min, elasticity, AIx / HR, Frequency and magnitude of fourier component significantly changed by analysis of Cun, Guan, and Chi. Conclusions : The effect of Sa-Am acupuncture with large intestine tonifying and sedating in healthy human may be observed on time, amplitude, pulse area, augmentation index and fourier components parameters. The parameters analysed in this study may be used to differentiate the effects between Sa-Am acupuncture with large intestine tonifying and sedating on radial pulse. Further studies on the effects of Sa-Am acupuncture using radial pulse are needed.

A study on Radial pulse diagnosis of the korean medicine (한방 맥 진단에 관한 연구)

  • Lee, H.J.;Kim, J.W.;Huh, W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.71-74
    • /
    • 1992
  • This paper describes research about the realization of computerized radial pulse diagnosis system in order to remove the subjectivity of a diagnostician, when diagnostician diagnoses a sickness using tactile percept ion in korean traditional medicine. Using radial pulse wave detection system, we effectively measured pressure radial pulse rave and after analyzing it, we detected the characteristic parameters and also quantified it and then we objectified more or less the judgement standard of radial pulse diagnosis by the aids of a clinical expert. on this base, we confirmed the possibility for realizing of automatic radial pulse diagnosis by radial pulse diagnosis system.

  • PDF

Radial vibration behaviors of cylindrical composite piezoelectric transducers integrated with functionally graded elastic layer

  • Wang, H.M.;Wei, Y.K.;Xu, Z.X.
    • Structural Engineering and Mechanics
    • /
    • v.38 no.6
    • /
    • pp.753-765
    • /
    • 2011
  • The radial vibration behaviors of a circular cylindrical composite piezoelectric transducer (CPT) are investigated. The CPT is composed of a piezoelectric ring polarized in the radial direction and an elastic ring graded in power-law variation form along the radial direction. The governing equations for plane stress state problem under the harmonic excitation are derived and the exact solutions for both piezoelectric and functionally graded elastic rings are obtained. The characteristic equations for resonant and anti-resonant frequencies are established. The presented methodology is fit to carry out the parametric investigation for composite piezoelectric transducers (CPTs) with arbitrary thickness in radial direction. With the aid of numerical analysis, the relationship between the radial vibration behaviors of the cylindrical CPT and the material inhomogeneity index of the functionally graded elastic ring as well as the geometric parameters of the CPTs are illustrated and some important features are reported.

A Global Optimization Method of Radial Basis Function Networks for Function Approximation (함수 근사화를 위한 방사 기저함수 네트워크의 전역 최적화 기법)

  • Lee, Jong-Seok;Park, Cheol-Hoon
    • The KIPS Transactions:PartB
    • /
    • v.14B no.5
    • /
    • pp.377-382
    • /
    • 2007
  • This paper proposes a training algorithm for global optimization of the parameters of radial basis function networks. Since conventional training algorithms usually perform only local optimization, the performance of the network is limited and the final network significantly depends on the initial network parameters. The proposed hybrid simulated annealing algorithm performs global optimization of the network parameters by combining global search capability of simulated annealing and local optimization capability of gradient-based algorithms. Via experiments for function approximation problems, we demonstrate that the proposed algorithm can find networks showing better training and test performance and reduce effects of the initial network parameters on the final results.