• Title/Summary/Keyword: Radial Deviation

Search Result 77, Processing Time 0.028 seconds

Multi-axial Force Characteristics of Radial Electrodynamic Wheel (래디알 동전기 휠의 다축력 특성)

  • Jung, Kwangsuk
    • Journal of Institute of Convergence Technology
    • /
    • v.7 no.2
    • /
    • pp.1-5
    • /
    • 2017
  • The rotating electrodynamic wheel over a conductive plate produces thrust force as well as normal force. Specially, separating the conductive plate and spacing apart each part, the lateral stability of the rotating wheel is guaranteed due to the restoring force into neutral position. In this paper, the force characteristics of the electrodynamic wheel rotating over the conductive plate is analyzed using the finite element tool. First, the dominant parameters are identified considering the geometric configuration and the operating condition. And the sensitivity for the parameter deviation is quantified for the high force density. The above topology can be applied as an actuating principle for inter-city train as well as contact-free transfer device.

Effective Doses in the Radial Gamma Radiation Field near a Point Source: Gender Difference and Deviation from the Personal Dose Equivalent (점선원 감마선장에서 유효선량의 성별차 및 개연선량당량과의 차이)

  • Chang, Jai-Kwon;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.4
    • /
    • pp.299-307
    • /
    • 1997
  • The individual dose equivalent, $H_p$, effective dose, E, and gender specific effective dose, $E^m$ and E$^f$, were evaluated using the male and female phantoms of MIRD type located in the radial gamma radiation field near a point source. The point sources were placed at the distances of 15, 40 and 100 cm in front of the body at different heights. Two radionuclides, $^{137}Cs$ and $^{131}I$, were selected for the illustrative examples. In terms of the gender specific effective doses, $E^f$ is higher than $E^m$ with a few exceptions, e.g. the case where the point source is at the height of reproductive organs, but the differences from the sex- averaged values are not significant enough to justify use of gender specific dose conversion factors for the radial gamma field. The ratios $H_p$/E were in the range of 1 to 3 depending on the source and dosimeter positions when the dosimeter is worn on the front surface of the torso covering from chest to lower abdomen, but varied from 0.34 to 6.5 in extreme cases. When it is assumed that the typical handling procedure of radioactive source material and the typical dosimeter position(on the chest) be respected, the dosimeters calibrated against the broad parallel field appear to provide estimates with acceptable errors for the effective dose of workers exposed to radial broad gamma field around a point source.

  • PDF

Clinical and Radiological Results of Treating Unstable Distal Radial Fractures with a Domestically Developed Volar Locking Plate That Has the Characteristic of Double-Tiered Subchondral Support (불안정성 원위 요골 골절의 치료에 있어 한국형 이중 연골하지지고정 전방 금속판의 임상적 및 방사선학적 결과)

  • Lee, Chul-Hyung;Jung, Deukhee;An, Chung-Han;Jeong, Uitak
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.6
    • /
    • pp.495-502
    • /
    • 2020
  • Purpose: The aim of this study was to assess the effectiveness of domestically developed volar locking plate which has the concept of double-tiered subchondral support (DSS) in maintaining the reduction after distal radial fracture surgery. Materials and Methods: From July 2017 to December 2018, 54 patients were assessed. Plain radiographs were obtained immediately after surgery and at the last follow-up, and the radiographic parameters were measured in those images: radial length, radial inclination, volar tilt, ulnar variance, and distal dorsal cortical distance. The patients were subdivided into their age, type of fracture, and the position of the plate to evaluate the influence of each factors on the reduction maintenance. Results: Distal dorsal cortical distance in radiographs after the surgery was 5.91 mm (standard deviation, ±1.95 mm) on average. Significant differences in the radial length (p=0.038) and ulnar variance (p=0.001) were observed between immediately after surgery and at the last follow-up. When the parameters were evaluated by dividing the patients into subgroups according to the three specific factors, the ulnar variance showed a significant increase at the last follow-up when the patients were included 65-years-old or older. AO/OTA type C3 fracture, and Soong classification grade 0 plate position (p=0.007, p=0.012, p=0.046, respectively). Conclusion: Using the domestically developed DSS-type volar locking plate, significant reduction after distal radial fracture surgery could be maintained successfully. On the other hand, further study will be needed to determine about the reduction loss of the lunate facet identified in special cases that deal with fractures in elderly patients, unstable AO/OTA type C3 distal radial fractures, and Soong classification grade 0 plate position.

Anisotropy in a Few mm Regions from an Ir192 High Dose Rate Source Measured with a GafChromic Film in Acrylic Phantom (아크릴 팬톰에서 GafChromic 필름을 이용한 고선량률 근접 치료용 Ir-192 선원의 근접 거리에서 비등방성 측정)

  • Huh, Hyun-Do;Kim, Seong-Hoon;Park, Jin-Ho;Cho, Byung-Chul;Shin, Dong-Oh;Soo il Kwon;Chun, Ha-Chung;John J K Loh;Kim, Woo-Chul
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.94-99
    • /
    • 2004
  • Radiochromic film has several advantages; high spatial resolution, relatively low spectral sensitivity, near tissue equivalence and requires no special development procedure. The object of this study was to measure the anisotropy of an Ir-192 source (microSelectron manufactured by Nucletron) in a few mm regions from the source, using the GafChromic film. The GafChromic film was calibrated in the range of 0∼105 Gy, using a 4 MV photon beam, and the anisotropy function measured in an acrylic phantom using the GafChroimic film. The data obtained gave agreement to within 4.4% of the Monte Calro calculation, by J. F. Williamson, at a radial distance of 2.5 mm with polar angles of 50 to 130$^{\circ}$, while a maximum deviation of 17.6% was observed at angles near 140$^{\circ}$and agreement within 3.7% at a radial distance of 5 mm at polar angles between 35 to 150$^{\circ}$ and a maximum deviation of 7.6% was observed at angles near 30$^{\circ}$. A GafChromic film can be used as a more efficient detector for measuring the anisotropy of an HDR $^{192}$ Ir source at close distances than any other detector.

  • PDF

Biometric analysis hand parameters in young adults for prosthetic hand and ergonomic product applications

  • Gkionoul Nteli Chatzioglou;Yelda Pinar;Figen Govsa
    • Anatomy and Cell Biology
    • /
    • v.57 no.2
    • /
    • pp.172-182
    • /
    • 2024
  • This study aimed to evaluate the superficial anatomy, kinesiology, and functions of the hand to reveal its morphometry and apply the findings in various fields such as prosthetic hand and protective hand support product design. We examined 51 young adults (32 females, 19 males) aged between 18-30. Hand photographs were taken, and measurements were conducted using ImageJ software. Pearson correlation analysis was performed to determine the relationship between personal information and the parameters. The results of the measurements showed the average lengths of finger segments: thumb (49.5±5.5 mm), index finger (63.9±4.1 mm), middle finger (70.7±5.2 mm), ring finger (65.5±4.8 mm), and little finger (53.3±4.3 mm). Both females and males, the left index finger was measured longer than the right index finger. The right ring finger was found to be longer than the left in both sexes. Additionally, length differences between fingers in extended and maximally adducted positions were determined: thumb-index finger (56.1±6.2 mm), index-middle finger (10.7±4.1 mm), middle-ring finger (10.8±1.4 mm), and ring-little finger (25.6±2.7 mm). Other findings included the average radial natural angle (56.4°±10.5°), ulnar natural angle (23.4°±7.1°), radial deviation angle (65.2°±8.2°), ulnar deviation angle (51.2°±9.6°), and grasping/gripping angle (49.1°±5.8°). The average angles between fingers in maximum abduction positions were also measured: thumb-index finger (53.4°±6.5°), index-middle finger (17.2°±2.6°), middle-ring finger (14.3°±2.3°), and ring-little finger (32.1°±7.0°). The study examined the variability in the positioning of proximal interphalangeal joints during maximum metacarpophalangeal and proximal interphalangeal flexion, coinciding with maximum distal interphalangeal extension movements. The focal points of our observations were the asymmetrical and symmetrical arches formed by these joints. This study provides valuable hand parameters in young adults, which can be utilized in various applications such as prosthetic design, ergonomic product development, and hand-related research. The results highlight the significance of considering individual factors when assessing hand morphology and function.

A Study on the Solid Shapes of Knit Flare Skirts Using 3-Dimensional Image Analysis (3차원 형상계측에 의한 니트 플레어스커트의 입체형상에 관한 연구)

  • Ki, Hee-Sook
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.13 no.2
    • /
    • pp.103-119
    • /
    • 2011
  • This study set out to analyze the solid shapes of knit flared skirts, which are best represented in a 3-dimensional shape for all knit skirts, according to the seamed and seamless production method and to estimate the silhouettes of knit flared skirts based on the results. It also aimed to help with the introduction and spread of seamless weaving by revising and supplementing potential problems and provide findings that would be put to active use as basic data, thus contributing to the development of original knitwear and offering fundamental materials for the development of the knitting industry. A number of experimental knit flared skirts were made according to skirt angle ($90^{\circ}$ and $180^{\circ}$), gauge (7G, 12G, and 15G), and grain (bias, wale, and radial), including 12 kinds of seamed knit flared skirts and 6 kinds of seamless knit flared skirts. Using a three-dimensional shape measurement system, the investigator measured the cross-sectional shapes of their hemlines. The SPSS 12 Version program was used for statistical processing, and descriptive statistics such as mean and standard deviation were used to compare the seamed and seamless knit flared skirts in the measurements (measurement items) of their solid shapes according to the width, gauges, and grain directions. The central grain direction of seamless knit flared skirts was in a radial form and even hemlines, thus presenting a beautiful appearance and solid shape. The 3-dimensional shapes show that seamless knit flared skirts are superior to seamed ones. The research findings are expected to open a door for Korea's knitting industry to quickly respond to small quantity batch production and additional orders.

  • PDF

Accurate Interpretation of Electron Diffraction Data Acquired by Imaging Plates (Imaging Plate에 기록된 전자회절자료의 해석)

  • Kim, Young-Min;Kim, Youn-Joong
    • Applied Microscopy
    • /
    • v.33 no.3
    • /
    • pp.195-204
    • /
    • 2003
  • The Experimental calibration method has been investigated to correct d-spacing estimation and to identify phases in the electron diffraction data acquired by imaging plates. When the diffraction data from the imaging plate was corrected by the d-spacing calibration method with the radial intensity distribution plotting in this experiment, The accuracy of d-spacing estimation was significantly increased in errors of about 0.5%. The experimental calibration equation followed up the first order exponential decay function was derived from the trace of d-spacing deviation between the measured and the calculated values. It was applied to the analysis of d-spacing and the phase identification of the transitional phases formed from [001] gibbsite specimen by electron beam irradiation effect. In this case more accurate phase identification and d-spacing evaluation is possible for the transitional phases whose diffraction patterns are complicatedly superimposed. It is concluded that ${\chi}$-alumina, ${\gamma}$-alumina and ${\sigma}$-alumina are clearly identified as the major transitional phases formed from gibbsite by electron beam irradiation for 120 min.

A Study on Hydro-mechanical Behaviors of Rock Joints using Rotary Shear Testing Apparatus (회전식 전단시험기를 이용한 암석절리의 수리-역학적 거동에 관한 연구)

  • 천대성;이희석;이정인
    • Tunnel and Underground Space
    • /
    • v.9 no.4
    • /
    • pp.328-336
    • /
    • 1999
  • To characterize the hydro-mechanical behavior of a rock joint, a rotary shear testing apparatus was devised in this study. Shear stress was driven by twisting the end of a sample in the rotary shear testing apparatus. The test results show that the rotary shear test underestimates the peak shear strength of a rock joint. The torque is known as a function of the radial distance from the axis of rotation, resulting in the radial variation of the shear stress. Fluid flow through rock joints is mainly dependent on the Joint roughness, contact area, initial aperture. To examine the dependency, the relationship between the hydraulic and the mechanical apertures for shear-flow was established by measuring the initial aperture. It shows that the mechanical aperture and the hydraulic aperture increase linearly with the dilatancy. The difference between the hydraulic and mechanical apertures describes the deviation from the behavior predicted by the parallel plate model.

  • PDF

A Steady-State Simulation and Experimental Study of Turboshaft Engine with Free Power Turbine (분리축방식 터보축 엔진의 정상상태 모사 및 실험연구)

  • 공창덕;기자영;고광웅
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.1 no.2
    • /
    • pp.84-90
    • /
    • 1997
  • The turboshaft engine with the free power turbine has been used for various purposes, for instance electric power generator, emergency power source, helicopter powerplant and so on. Steady-state simulation program was developed and experimental tests was carried out for comparing with computer simulation results. The test unit was composed of 1-stage centrifugal compressor, the can type combustor chamber, 1-stage radial type compressor turbine, and radial type free power turbine, and its output power is obtained from 3-phase AC generator. Main component characteristics which was used for the steady state simulation program, were obtained from the manufacturer of the test unit, and modified from experimental results of test unit. In comparison between computer simulation and experimental test results even though the test unit has the operational limit, deviation of component performance characteristics in simulation were within 6% range of experimental results.

  • PDF

Design of Echo Classifier Based on Neuro-Fuzzy Algorithm Using Meteorological Radar Data (기상레이더를 이용한 뉴로-퍼지 알고리즘 기반 에코 분류기 설계)

  • Oh, Sung-Kwun;Ko, Jun-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.5
    • /
    • pp.676-682
    • /
    • 2014
  • In this paper, precipitation echo(PRE) and non-precipitaion echo(N-PRE)(including ground echo and clear echo) through weather radar data are identified with the aid of neuro-fuzzy algorithm. The accuracy of the radar information is lowered because meteorological radar data is mixed with the PRE and N-PRE. So this problem is resolved by using RBFNN and judgement module. Structure expression of weather radar data are analyzed in order to classify PRE and N-PRE. Input variables such as Standard deviation of reflectivity(SDZ), Vertical gradient of reflectivity(VGZ), Spin change(SPN), Frequency(FR), cumulation reflectivity during 1 hour(1hDZ), and cumulation reflectivity during 2 hour(2hDZ) are made by using weather radar data and then each characteristic of input variable is analyzed. Input data is built up from the selected input variables among these input variables, which have a critical effect on the classification between PRE and N-PRE. Echo judgment module is developed to do echo classification between PRE and N-PRE by using testing dataset. Polynomial-based radial basis function neural networks(RBFNNs) are used as neuro-fuzzy algorithm, and the proposed neuro-fuzzy echo pattern classifier is designed by combining RBFNN with echo judgement module. Finally, the results of the proposed classifier are compared with both CZ and DZ, as well as QC data, and analyzed from the view point of output performance.