• Title/Summary/Keyword: Radar Data

Search Result 1,419, Processing Time 0.032 seconds

Grounding Line of Campbell Glacier in Ross Sea Derived from High-Resolution Digital Elevation Model (고해상도 DEM을 활용한 로스해 Campbell 빙하의 지반접지선 추정)

  • Kim, Seung Hee;Kim, Duk-jin;Kim, Hyun-Cheol
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.3
    • /
    • pp.545-552
    • /
    • 2018
  • Grounding line is used as evidence of the mass balance showing the vulnerability of Antarctic glaciers and ice shelves. In this research, we utilized a high resolution digital elevation model of glacier surface derived by recently launched satellites to estimate the position of grounding line of Campbell Glacier in East Antarctica. TanDEM-X and TerraSAR-X data in single-pass interferometry mode were acquired on June 21, 2013 and September 10, 2016 and CryoSat-2 radar altimeter data were acquired within 15 days from the acquisition date of TanDEM-X. The datasets were combined to generate a high resolution digital elevation model which was used to estimate the grounding line position. During the 3 years of observation, there weren't any significant changes in grounding line position. Since the average density of ice used in estimating grounding line is not accurately known, the variations of the grounding line was analyzed with respect to the density of ice. There was a spatial difference from the grounding line estimated by DDInSAR whereas the estimated grounding line using the characteristics of the surface of the optical satellite images agreed well when the ice column density was about $880kg/m^3$. Although the reliability of the results depends on the vertical accuracy of the bathymetry in this study, the hydrostatic ice thickness has greater influence on the grounding line estimation.

Sounding Observation with Wind Profiler and Radiometer of the Yeongdong Thundersnow on 20 January 2017 (2017년 1월 20일 영동 뇌설 사례에 대한 연직바람관측장비와 라디오미터 관측 자료의 분석)

  • Kwon, Ju-Hyeong;Kwon, Tae-Yong;Kim, Byung-Gon
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.3
    • /
    • pp.465-480
    • /
    • 2018
  • On 20 January 2017, the fresh snow cover which is more than 20 cm, accompaning with lightning occurred over Yeongdong coastal region for the first 3-hour of the heavy snowfall event. This study analyzed sounding observations in the heavy snow period which were including the measurements of wind profiler, radiometer and rawinsonde. The features examined from the vertical wind and temperature data at the two adjacent stations, Bukgangneung and Gangneung-Wonju National University, are summarized as follows: 1) The strong (30-40 kts) north-east winds were observed in the level from 2 to 6 km. The Strong atmospheric instability was found from 4 to 6 km, in which the lapse rate of temperature was about $-18^{\circ}C\;km^{-1}$. These features indicate that the deep convective cloud develops up to the height of 6 km in the heavy snowfall period, which is shown in the satellite infrared images. 2) The cooling was observed in the level below 1 km. At this time, the surface air temperature at Bukgangneung station decreased by $4^{\circ}C$. The narrow cooling zone estimated from AWS and buoy data was located in east-west direction. These are the features observed in the cold front of extratropical cyclone. The distributions of radar echo and lightning also show the same shape in east-west direction. Therefore, the results indicate that the Yeongdong thundersnow event was the combined precipitation system of deep convective cloud and cold frontal precipitation.

The Effects of Emotional Intelligence on the Customer Orientation and Customer Relationship Management Performance of Hotel Employees (호텔기업 종업원의 감성지능이 고객지향성과 CRM성과에 미치는 영향)

  • Jeon, Ta-Sik;Nam, Taek-Young
    • Journal of Distribution Science
    • /
    • v.10 no.10
    • /
    • pp.17-24
    • /
    • 2012
  • Purpose - This study aimed to (a) investigate the effects of emotional intelligence on customer orientation, (b) examine the impact of customer orientation on customer relationship management (CRM) performance (including CRM-related variables such as 'relationship commitment,' 'image of corporation,' and 'customer loyalty'), and (c) identify the conceptual framework of emotional intelligence. Research design, data, and methodology - The data were collected using a questionnaire given to a sample of employees of luxury hotels in the metropolitan area. To test the hypotheses, AMOS were conducted for the 271 respondents of the sample using the SPSS Win 17.0 software. The concept of emotional intelligence (EI) has been on the radar of many leaders and managers over the past few decades. Emotional intelligence is generally accepted to be a combination of emotional and interpersonal competencies that influence behavior, thoughts, and interactions with others. Emotional intelligence consists of four factors: understanding the self's emotion, understanding other people's emotions, emotion utilization, and emotion control. Understanding the self's emotion means to understand of my own emotions. Understanding other people's emotions is to understand of the emotions of the people around me and to know how my friends feel based on their behavior. The concept of emotion utilization means to set goals for myself and then try to achieve them, encouraging myself to do my best. The concept of emotion control means I can control my temper, handle difficult situations rationally, and calm down quickly when I am very angry. Results - As a result of the analysis, three factors (understanding the self's emotion, understanding of other people's emotions, and emotion utilization) were shown to have a significant effect on customer orientation. Emotion control had an insignificant effect on customer orientation. Only emotion control makes it difficult to solve customers' problems because it is a passive behavior. In order to solve the customers' problems, hotel employees have to show a positive attitude. Second, customer orientation had a significant effect on customer relationship management performance (customer relationship commitment, corporate image, and customer loyalty). In other words, customer orientation increases commitment to customer relationships. For example, employees who have a customer-orientated perspective provide good service to their customers, while employees who don't have a customer-orientated perspective can't satisfy their customers. Customer orientation can also generate a good image among customers, because they evaluate the image of a hotel through the behavior of hotel employees. So it is very important for employees to show excellent customer orientation. Conclusions - It is very important for hotel CEOs to manage their employees' emotional intelligence. In order to increase their employees' emotional intelligence abilities, CEOs have to manage the overall corporate culture and reward programs to achieve what they want. This is because the system can lead to a customer-orientated mind-set and CRM performance among employees. As a result, the hotel CEO has to pay attention to the emotional intelligence of employees to achieve strong CRM performance. The sentence as originally written was a bit unclear. If this edit does not retain your intended meaning please consider: "Only emotion control does not have a significant impact on customer orientation, and therefore on the ability of an employee to solve customer problems, because it is a passive behavior." Please use the version of the sentence that best captures your original meaning.

  • PDF

Multidimensional Model for Assessing Risks from Occupational Radiation Exposure of Workers (직업상 피폭에 따른 방사선 위험성 평가를 위한 다차원적 모델)

  • Bae, Yu-Jung;Kim, Byeong-soo;Gwon, Da-yeong;Kim, Yong-min
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.555-564
    • /
    • 2017
  • The current radiation risk assessment for occupational exposure is based on the measured exposure dose and health checkups of workers. This people-centered risk assessment may occur errors because absence of using personal dosimeter or unrelated health symptoms of individuals lead to difficulties in obtaining accurate data from workers. In addition, although the established legal upper dose limit was used as a reference for the assessment, it does not imply that this limit is the optimal dose of radiation workers should get; ALARA principle should always be appreciated. Therefore, a new risk assessment model that can take account of all the important factors and implement optimization of radiation protection is required at the national level. In this paper, based on the KOSHA Risk Assessment, we studied on the workplace-centered risk assessment model for radiation field rather than the people-centered. The result of the study derived a right model for radiation field through the analysis of the risk assessment methods in various fields and also found data acquisition methods and procedures for applying to the model. Multidimensional model centering on the workplace will enables more accurate radiation risk assessment by using a risk index and radar plot, and consequently contribute to the efficient worker management, preemptive worker protection and implementation of optimization of radiation protection.

Construction of the Regional Basemap for a Developing Country: Focused on the Bab Ezzouar Municipality in Algeria (개발도상국 지역분석용 베이스맵 구축방안: 알제리의 밥 에주아흐 지역을 중심으로)

  • Lee, Yong Jik;Choei, Nae Young
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.1
    • /
    • pp.89-99
    • /
    • 2015
  • Recently, our construction industry is actively participating in numerous city planning projects in the third world countries. Considering the current depression of domestic real estate market, the emerging foreign demands could certainly provide substantial opportunities for the domestic industry to overcome the trough. For the field planners dealing with such foreign projects, though, the immediate problem is the lack of public statistics and geographic information to perform spatial analyses and/or prepare master plans. This study, in this context, tries to simulate a process to construct a digitized basemap of the case area, 'Bab Ezzouar,' in Algeria of Northern Africa. The area is a typical municipality that lacks the IT databases. To overcome the data shortage, the study uses the satellite map tiles so as to digitize the roads and building structures. It then estimates the block-wise populations based on the building image interpolation as well as the supplementary field survey data. The topographic TINs are also built by the SRTM (Shuttle Radar Topography Mission) digital elevation maps so that the three-dimensional configuration of the structures and terrains are rendered to check the urban scenery and skylines.

Detection of Water Cloud Microphysical Properties Using Multi-scattering Polarization Lidar

  • Xie, Jiaming;Huang, Xingyou;Bu, Lingbing;Zhang, Hengheng;Mustafa, Farhan;Chu, Chenxi
    • Current Optics and Photonics
    • /
    • v.4 no.3
    • /
    • pp.174-185
    • /
    • 2020
  • Multiscattering occurs when a laser transmits into dense atmosphere targets (e.g. fogs, smoke or clouds), which can cause depolarization effects even though the scattering particles are spherical. In addition, multiscattering effects have additional information about microphysical properties of scatterers. Thus, multiscattering can be utilized to study the microphysical properties of the liquid water cloud. In this paper, a Monte Carlo method was used to simulate multi-scattering transmission properties of Lidar signals in the cloud. The results showed the slope of the degree of linear polarization (SLDLP) can be used to invert the extinction coefficient, and then the cloud effective size (CES) and the liquid water content (LWC) may be easily obtained by using the extinction coefficient and saturation of the degree of linear polarization (SADLP). Based on calculation results, a microphysical properties inversion method for a liquid cloud was presented. An innovative multiscattering polarization Lidar (MSPL) system was constructed to measure the LWC and CES of the liquid cloud, and a new method based on the polarization splitting ratio of the Polarization Beam Splitter (PBS) was developed to calibrate the polarization channels of MSPL. By analyzing the typical observation data of MSPL observation in the northern suburbs of Nanjing, China, the LWC and CES of the liquid water cloud were obtained. Comparisons between the results from the MSPL, MODIS and the Microwave radar data showed that, the microphysical properties of liquid cloud could be retrieved by combining our MSPL and the inversion method.

The LVC Linkage for the Interoperability of the Battle Lab (Battle Lab에서의 상호운용성을 위한 LVC 연동방안)

  • Yun, Keun-Ho;Shim, Shin-Woo;Lee, Dong-Joon
    • Journal of the Korea Society for Simulation
    • /
    • v.21 no.1
    • /
    • pp.81-88
    • /
    • 2012
  • In the M&S filed, The Battle Lab is available for acquisition, design, development tool, validation test, and training in the weapon system of development process. Recently, the Battle Lab in the military of Korea is still in an early stage, in spite of importance of battle lab construction. In the environment of network centric warfare, a practical use of the M&S which is connecting live, virtual and constructive model can be applied to all field of System Engineering process. It is necessary thar the Battle Lab is not restricted by time and space, and is possible for the technical implementation. In this paper, to guarantee the interoperability of live and virtual simulation, virtual simulators connect live simulators by using the tactical data link. To guarantee the interoperability of virtual and constructive simulation, both virtual simulators and constructive simulators use the RTI which is the standard tool of M&S. We propose the System that constructed the Air Defence Battle Lab. In case of the approach of target tracks, The Air Defence Battle Lab is the system for the engagement based on a command of an upper system in the engagement weapon system. Constructive simulators which are target track, missile, radar, and launcher simulator connect virtual simulators which are MCRC, battalion, and fire control center simulators using the RPR-FOM 1.0 that is a kind of RTI FOM. The interoperability of virtual simulators and live simulators can be guaranteed by the connection of the tactical data links which are Link-11B and ATDL-1.

Improvement of Small Baseline Subset (SBAS) Algorithm for Measuring Time-series Surface Deformations from Differential SAR Interferograms (차분 간섭도로부터 지표변위의 시계열 관측을 위한 개선된 Small Baseline Subset (SBAS) 알고리즘)

  • Jung, Hyung-Sup;Lee, Chang-Wook;Park, Jung-Won;Kim, Ki-Dong;Won, Joong-Sun
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.2
    • /
    • pp.165-177
    • /
    • 2008
  • Small baseline subset (SBAS) algorithm has been recently developed using an appropriate combination of differential interferograms, which are characterized by a small baseline in order to minimize the spatial decorrelation. This algorithm uses the singular value decomposition (SVD) to measure the time-series surface deformation from the differential interferograms which are not temporally connected. And it mitigates the atmospheric effect in the time-series surface deformation by using spatially low-pass and temporally high-pass filter. Nevertheless, it is not easy to correct the phase unwrapping error of each interferogram and to mitigate the time-varying noise component of the surface deformation from this algorithm due to the assumption of the linear surface deformation in the beginning of the observation. In this paper, we present an improved SBAS technique to complement these problems. Our improved SBAS algorithm uses an iterative approach to minimize the phase unwrapping error of each differential interferogram. This algorithm also uses finite difference method to suppress the time-varying noise component of the surface deformation. We tested our improved SBAS algorithm and evaluated its performance using 26 images of ERS-1/2 data and 21 images of RADARSAT-1 fine beam (F5) data at each different locations. Maximum deformation amount of 40cm in the radar line of sight (LOS) was estimated from ERS-l/2 datasets during about 13 years, whereas 3 cm deformation was estimated from RADARSAT-1 ones during about two years.

RADARSAT SAR Investigations of Lineament and Spring Water in Cheju Island (RADARSAT SAR 자료를 이용한 제주도 선구조 연구 및 용천 특성 연구)

  • 원중선;류주형;지광훈
    • Korean Journal of Remote Sensing
    • /
    • v.14 no.4
    • /
    • pp.325-342
    • /
    • 1998
  • Two RADARSAT SAR images with different modes acquired by Canadian Space Agency to test the effectiveness of geological lineament extraction and spring water detection over the Cheju Island. Geological lineaments are poorly developed this basalt dominant volcanic island, but more linear features can be extracted when SAR and TM images are simultaneously analyzed than when TM image alone is used. This results mainly owe to the facts that RADARSAT SAR systems are able to provide data with different frequencies, azimuth, and incidence angles. Distribution of spring water along coast is poorly correlated with geological lineaments or drainage pattern, but those in middle range of mountain region are developed along geological lineaments. Detection of spring water using remotely sensed images are turned out to be very difficult to achieve. Radial shaped sea surface temperature anomaly derived from TM thermal band should be the best candidate for spring water, but the resolution is not high enough. We also investigate the normalized radar cross section (or sigma naught) converted from RADARSAT and ERS-1 SAR data but to discriminate the spring water effectively except where relatively large water mass is observed on land side. Speckle noise and irregularity in physical sea surface condition are the serious obstacles for this application. ERS-1 SAR image acquired in low incidence angle was more useful for geological lineament estimation and water body study than RADARSAT SAR images with high incidence angles. Therefore the selection of incidence angle is critical in geological and spring water applications of SAR images, and low incidence angles less than about 30$^{\circ}$ are recommended to monitor the Cheju volcanic island.

Back-scattering Characteristic Analysis for SAR Calibration Site (SAR 검보정 Site 구축을 위한 후방 산란 특성 분석)

  • Lee, Taeseung;Yang, Dochul
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.2
    • /
    • pp.305-319
    • /
    • 2021
  • The overseas calibration sites such as Mongolia used for Korea Multi-purpose Satellite (KOMPSAT-5 or K5), have a disadvantage in that maintenance and repair costs are high and immediate response is difficult when an unexpected problem occurs. Accordingly, the necessity of establishing a domestic SAR calibration site was suggested, but the progress of related research is insignificant. In this paper, we investigated what conditions should be satisfied in terms of backscattering characteristics to construct a site for SAR satellite image quality evaluation and calibration. First of all, it was selected first by applying general indicators such as accessibility and availability among places recommended as satellite image calibration candidate sitesin Korea. Next, three places, site A (Goheung-gun, Jeollanam-do), site B (Jeonju-si, Jeollabuk-do), and site C (Daedeok Research Complex, Daejeon), were selected as the final candidates because they are relatively wide and easy to install AT or CR. Site A, located in Goheung-gun, Jeollanam-do, was best considered in terms of slope measurements, minimum site area to obtain ISLR, uniformity of DN values and backscatter coefficients, interference by strong reflectors, and backscatter clutter level.