• Title/Summary/Keyword: Rad4

Search Result 308, Processing Time 0.024 seconds

Change of Serum Steroid Level in the Whole-body Irradiated Rat (방사선 처리를 받은 흰쥐의 혈청내 스테로이드호르몬의 변화)

  • Shin, Jang-Sik;Lee, Young-Keun;Kim, Moon-Kyoo;Yoon, Yong-Dal
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.21 no.3
    • /
    • pp.297-303
    • /
    • 1994
  • The effect of radiation on the steroidogenesis of rat ovary was investigated. For this purpose, female rats aged 7-8 weeks were exposed to a single dose of ${\gamma}$ radiation(320 rad or 800 rad) by the cobalt-60. At fourth(day of the first estrus) and eighth(day of the second estrus) days after irradiation, the concentrations of serum steroid hormones were determined by radioimmunoassays (RIA). The correlation between survival rate(Y) and radiation dose(X) was Y=-0.06X+100(r=0.89, n=10). Lethal dose$(LD)_{50(30)}$ and $LD_{20(30)}$ were 833.33rad and 333.33rad respectively. The weights of body and ovary was decreased significantly by the $LD_{50(30)}$ irradiation during the 4 days, but both weights were recovered at day 8. The serum levels of 17a-hydroxyprogesterone(170HP) and estradiol($E_2$) in the irradiated rats were not generally different from those of control. However, the levels of testosterone(T) and 19-norterstosterone(19NT) in the irradiated rat at $LD_{50(30)}$ and $LD_{20(30)}$ radiation doses were decreased, while progesterone levels in serum of the irradiated rats were slightly increased. These results suggest that irradiation may inhibit the first step of steroidogenesis, especially the conversion of P to T, in the rat ovary.

  • PDF

Subtraction of excess noise in a gyroscope employing a high-power erbium-doped fiber source (고출력 Erbium 첨가 광섬유 광원을 사용하는 자이로스코프에서 광원 과잉잡음의 소거)

  • 진영준;박태용;박희갑
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.5
    • /
    • pp.396-400
    • /
    • 1999
  • In the fiber-optic gyroscope employing a high-power erbium-doped fiber source, the source excess noise was subtracted from the gyro output through a single processing to improve the gyroscope sensitivity. As the result, we obtained the reduction of noise by 13.5 dB (electrical) which was measured from the noise floor spectrum when the gyro was modulated with the depth of 1.8 rad. In addition, the random walk coefficient of the gyro output was reduced by a factor of 4~5.

  • PDF

An Ultraprecision Rotary Motor based on Inchworm-type Actuation (인치웜 구동방법에 의한 초정밀 회전모터)

  • Kim, Sang-Chae;Kim, Soo-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.3
    • /
    • pp.152-157
    • /
    • 2001
  • An ultraprecision rotary motor is developed using inchworm motion of two belts actuated by elongation of piezoelectric elements. A symmetric lever mechanism with flexure hinges is designed to connect belts with piezoelectric elements. The lever mechanism is used not only to amplify the elongation of piezoelectric element but also to minimize the numbers of components and the effort for assembly. By experiment, the rotational angle by one cycle is varied from $0.2{\times}10-4 rad to 9.76{\times}10-4$ rad depending on input signal amplitude. Further, the motor has the capability of getting more precise rotational resolution by enlarging the radius of the rotor.

  • PDF

Preliminary Report of the Lung Cancer (폐암의 방사선치료 결과에 대한 간이보고)

  • Ban, Sung-Beom;Choi, Myung-Sun
    • Radiation Oncology Journal
    • /
    • v.2 no.1
    • /
    • pp.81-86
    • /
    • 1984
  • The preliminary analysis has been made of 63 Patients who were treated in the Department of Radiation Therapy at Korea University Hospital for the lung cancer from April 1981 to December 1983. The patients were treated via Co-60 teletherapy unit and the doses were 5,400 rad/ 6 week for the curative, $3,600\~4,500\;rad/2\;1/2\;\~3$ week for the Palliative treatment. Thirty two $(32/63=51\%)$ patients have been for curative, $25/63 (40\%)$ were for Palliative, and $6/63 (9\%)$ were for post-operative radiation. A post-radiation treatment, $28/63 (53\%)$ were able to follow from 2 months to 3 yrs. During the follow up, chest X-rays and/or CT scans were taken and $22/27 (81.4\%)$ of patients were responded more than $50\%$ of tumor regression one month following completion of radiation.

  • PDF

Characteristics of A Diaphragm-Type Fiber Optic Fabry-Perot Interferometric Pressure Sensor Using A Dielectric Film (유전체 박막을 이용한 다이아프램형 광섬유 Fabry-Perot 간섭계 압력센서의 특성)

  • Kim, M.G.;Yoo, Y.W.;Kwon, D.H.;Lee, J.H.;Kim, J.S.;Park, J.H.;Chai, Y.Y.;Sohn, B.K.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.147-153
    • /
    • 1998
  • The strain characteristics of a fiber optic Fabry-Perot pressure sensor with high sensitivity using a $Si_{3}N_{4}/SiO_{2}/Si_{3}N_{4}$ (N/O/N) diaphragm is experimentally investigated. A 600 nm thick N/O/N diaphragm was fabricated by silicon anisotropic etching technology in 44 wt% KOH solution. An interferometric fiber optic pressure sensor has been manufactured by using a fiber optic Fabry-Perot intereferometer and a N/O/N diaphragm. The 2 cm length fiber optic Fabry-Perot interferometers in the continuous length of single mode fiber were produced with two pieces of single mode fiber coated with $TiO_{2}$ dielectric film utilizing the fusion splicing technique. The one end of the fiber optic Fabry-Perot interferometer was bonded to a N/O/N diaphragm. and the other end was connected to an optical setup through a 3 dB coupler. For the N/O/N diaphragm sized $2{\times}2\;mm^{2}$ and $8{\times}8\;mm^{2}$, the pressure sensitivity was measured 0.11 rad/kPa and 1.57 rad/kPa, respectively, and both of the nonlinearities were less than 0.2% FS.

  • PDF

The Effect of Hyperthermia Combined with Radiation on Crypts of the Mouse Jejunum (마우스공장 소낭선의 방사선 효과에 온열요법의 병용이 미치는 영향에 관한 실험적 연구)

  • Bae, Hoon-Sik;Park, Charn-Il;Kim, Jung-Jin
    • Radiation Oncology Journal
    • /
    • v.5 no.1
    • /
    • pp.13-21
    • /
    • 1987
  • The effect of local hyperthermia of 41 to $43^{\circ}C$ for 30 minutes on radiosensitivity of normal tissue was studied utilizing jejunal crypt microcolony assay. Hyperthermia of this range enhanced the radiation effect and the effect was mainly additive without significant effect on the slopes of cell survival curves. At the isoeffect level of 20 microcolony formation, the thermal enhancement ratio was 1.02, 1.10 and 1.39 for $41^{\circ},\;42^{\circ}\;and\;43^{\circ}C$, respectively. The distribution of microcolony formation along the circumference of jejunum was not uniform, having more colonies around the mesenteric border, and this suggests the effect of uneven cooling by blood circulation.

  • PDF

Gene Expression Biodosimetry: Quantitative Assessment of Radiation Dose with Total Body Exposure of Rats

  • Saberi, Alihossein;Khodamoradi, Ehsan;Birgani, Mohammad Javad Tahmasebi;Makvandi, Manoochehr
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8553-8557
    • /
    • 2016
  • Background: Accurate dose assessment and correct identification of irradiated from non-irradiated people are goals of biological dosimetry in radiation accidents. Objectives: Changes in the FDXR and the RAD51 gene expression (GE) levels were here analyzed in response to total body exposure (TBE) to a 6 MV x-ray beam in rats. We determined the accuracy for absolute quantification of GE to predict the dose at 24 hours. Materials and Methods: For this in vivo experimental study, using simple randomized sampling, peripheral blood samples were collected from a total of 20 Wistar rats at 24 hours following exposure of total body to 6 MV X-ray beam energy with doses (0.2, 0.5, 2 and 4 Gy) for TBE in Linac Varian 2100C/D (Varian, USA) in Golestan Hospital, in Ahvaz, Iran. Also, 9 rats was irradiated with a 6MV X-ray beam at doses of 1, 2, 3 Gy in 6MV energy as a validation group. A sham group was also included. After RNA extraction and DNA synthesis, GE changes were measured by the QRT-PCR technique and an absolute quantification strategy by taqman methodology in peripheral blood from rats. ROC analysis was used to distinguish irradiated from non-irradiated samples (qualitative dose assessment) at a dose of 2 Gy. Results: The best fits for mean of responses were polynomial equations with a R2 of 0.98 and 0.90 (for FDXR and RAD51 dose response curves, respectively). Dose response of the FDXR gene produced a better mean dose estimation of irradiated "validation" samples compared to the RAD51 gene at doses of 1, 2 and 3 Gy. FDXR gene expression separated the irradiated rats from controls with a sensitivity, specificity and accuracy of 87.5%, 83.5% and 81.3%, respectively, 24 hours after dose of 2 Gy. These values were significantly (p<0.05) higher than the 75%, 75% and 75%, respectively, obtained using gene expression of RAD51 analysis at a dose of 2 Gy. Conclusions: Collectively, these data suggest that absolute quantification by gel purified quantitative RT-PCR can be used to measure the mRNA copies for GE biodosimetry studies at comparable accuracy to similar methods. In the case of TBE with 6MV energy, FDXR gene expression analysis is more precise than that with RAD51 for quantitative and qualitative dose assessment.

An Implementation of the OTB Extension to Produce RapidEye Surface Reflectance and Its Accuracy Validation Experiment (RapidEye 영상정보의 지표반사도 생성을 위한 OTB Extension 개발과 정확도 검증 실험)

  • Kim, Kwangseob;Lee, Kiwon
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.5_1
    • /
    • pp.485-496
    • /
    • 2022
  • This study is for the software implementation to generate atmospheric and surface reflectance products from RapidEye satellite imagery. The software is an extension based on Orfeo Toolbox (OTB) and an open-source remote sensing software including calibration modules which use an absolute atmospheric correction algorithm. In order to verify the performance of the program, the accuracy of the product was validated by a test image on the Radiometric Calibration Network (RadCalNet) site. In addition, the accuracy of the surface reflectance product generated from the KOMPSAT-3A image, the surface reflectance of Landsat Analysis Ready Data (ARD) of the same site, and near acquisition date were compared with RapidEye-based one. At the same time, a comparative study was carried out with the processing results using QUick Atmospheric Correction (QUAC) and Fast Line-of-sight Atmospheric Analysis of Spectral Hypercubes (FLAASH) tool supported by a commercial tool for the same image. Similar to the KOMPSAT-3A-based surface reflectance product, the results obtained from RapidEye Extension showed accuracy of agreement level within 5%, compared with RadCalNet data. They also showed better accuracy in all band images than the results using QUAC or FLAASH tool. As the importance of the Red-Edge band in agriculture, forests, and the environment applications is being emphasized, it is expected that the utilization of the surface reflectance products of RapidEye images produced using this program will also increase.