• Title/Summary/Keyword: Rad4

Search Result 310, Processing Time 0.026 seconds

The Effect of 131I Therapy by Taking in Laxatives (방사성요오드 치료 시 완하제 투여 효과)

  • Kil, Sang-Hyeong;LEE, Hyo-Yeong;Park, Kwang-Yeol;Jo, Kyung-Nam;Baek, Seung-Jo;Hwang, Kyo-Min;Cho, Seong-Mook;Choi, Jae-Hyeok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.3-9
    • /
    • 2014
  • Purpose: Our goals were to evaluate the effect of high dose radioiodine treatment for thyroid cancer by taking in laxatives. Materials and Methods: Twenty patients(M:F=13:7, age $46.3{\pm}8.1\;yrs$) who underwent high dose radioiodine treatment were seperated into Group 1 taking $^{131}I$ 5,500 MBq and Group 2 with the use of laxatives after taking $^{131}I$ 5,500 MBq. The whole body was scanned 16 hours and 40 hours after taking radioactive iodines by using gamma camera, the ROIs were drawn on the gastro-intestinal tract and thigh for calculation of reduction ratio. At particular time during hospitalization, the radioactivity remaining in the body was measured in 1 meter from patient by using survey meter (RadEye-G10, Thermo Fisher Scientific, USA). Schematic presentation of an Origin 8.5.1 software was used for spatial dose rate. Statistical comparison between groups were done using independent samples t-test. P value less than 0.05 was regarded as statistically significant. Results: The reduction ratio in gastro-intestinal 16 hours and 40 hours after taking laxatives is $42.1{\pm}6.3%$ in Group 1 and $72.1{\pm}6.4%$ in Group 2. The spatial dose rate measured when discharging from hospital was $23.8{\pm}6.7{\mu}Sv/h$ in Group 1 and $8.2{\pm}2.4{\mu}Sv/h$ in Group 2. The radioactivity remaining in the body is much decreased at the patient with laxatives(P<0.05). Conclusion: The use in combination with laxatives is helpful for decreasing radioactivity remaining in the body. The radioactive contamination could be decreased at marginal individuals from patients.

  • PDF

Postoperative Evaluation of Congenital Atrial Septal Defect in Adult (성인 심방중격결손증의 술후평가)

  • Kim, Ae-Jung;Jo, Jung-Gu;Gu, Ja-Hong;Kim, Gong-Su
    • Journal of Chest Surgery
    • /
    • v.29 no.4
    • /
    • pp.386-392
    • /
    • 1996
  • Preoperative and postoperative evaluation was done in 60 adult patients above 20 years of age among 152 patients, who had operation for the congenital atrial septal defect from January 1984 to June 1993 in the Department of Thoracic and Cardiovascular Surgery, Chonbuk National University Hospital. Anatomically, the secundum type defect was present In 58 cases and the other two were ostium primum type defect. The defect were closed directly in 45 cases and with patches in 15 cases. Preopera ive EKG findings revealed regular sinus rhythm in 81%, arrhythmia 19%, RVH 32%, RAD 30%, Postoperative findings were regular sinus rhythm in 76%, arrhythmia 24%, RVH 25%. RAD 25%. In hemodynamic data, the mean SPAP in patients over 40 years old was 41.91 $\pm$ 14.33mmHg compared to 31.46 $\pm$ 13.77 mmHg in patients under 40 years old, and the difference between the two groups was stastistically significant. And then the patients were classified into two groups (group A sinus group, and group B : arrhythmia group) according to their preoperative rhythm. The patients in group B were older, had greater value of mean SPAP and Rp/Rs. Mean Qp/qs was higher in group A. But the difference between two groups about the mean Qp/qs and Rp/Rs was not significant. Postoperative complications such as arrhythmia, pneumothorax or hemothorax occurred in 7 cases, but there was no operative mortality. The functional improvement were remarkable in half of the patients who underwent surgery.

  • PDF

THE CHANGE OF THE INITIAL DYNAMIC VISCO-ELASTIC MODULUS OF COMPOSITE RESINS DURING LIGHT POLYMERIZATION (광중합 복합레진의 중합초기 동적 점탄성의 변화)

  • Kim, Min-Ho;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.5
    • /
    • pp.450-459
    • /
    • 2009
  • The aim of this study was to measure the initial dynamic modulus changes of light cured composites using a custom made rheometer. The custom made rheometer consisted of 3 parts: (1) a measurement unit of parallel plates made of glass rods, (2) an oscillating shear strain generator with a DC motor and a crank mechanism, (3) a stress measurement device using an electromagnetic torque sensor. This instrument could measure a maximum torque of 2Ncm, and the switch of the light-curing unit was synchronized with the rheometer. Six commercial composite resins [Z-100 (Z1), Z-250 (Z2), Z-350 (Z3), DenFil (DF), Tetric Ceram (TC), and Clearfil AP-X (CF)] were investigated. A dynamic oscillating shear test was undertaken with the rheometer. A certain volume ($14.2\;mm^3$) of composite was loaded between the parallel plates, which were made of glass rods (3 mm in diameter). An oscillating shear strain with a frequency of 6 Hz and amplitude of 0.00579 rad was applied to the specimen and the resultant stress was measured. Data acquisition started simultaneously with light curing, and the changes in visco-elasticity of composites were recorded for 10 seconds. The measurements were repeated 5 times for each composite at $25{\pm}0.5^{\circ}C$. Complex shear modulus G*, storage shear modulus G', loss shear modulus G" were calculated from the measured strain-stress curves. Time to reach the complex modulus G* of 10 MPa was determined. The G* and time to reach the G* of 10 MPa of composites were analyzed with One-way ANOVA and Tukey's test ($\alpha$ = 0.05). The results were as follows. 1. The custom made rheometer in this study reliably measured the initial visco-elastic modulus changes of composites during 10 seconds of light curing. 2. In all composites, the development of complex shear modulus G* had a latent period for $1{\sim}2$ seconds immediately after the start of light curing, and then increased rapidly during 10 seconds. 3. In all composites, the storage shear modulus G" increased steeper than the loss shear modulus G" during 10 seconds of light curing. 4. The complex shear modulus of Z1 was the highest, followed by CF, Z2, Z3, TC and DF the lowest. 5. Z1 was the fastest and DF was the slowest in the time to reach the complex shear modulus of 10 MPa.

Evaluation of the Automated Immunohematology Analyzer DAYMATE M (혈액은행 자동화 검사장비 DAYMATE M의 수행능 평가)

  • Yoo, Jaeeun;Yu, Hain;Choi, Hyunyu;Lee, Gyoo Whung;Song, Young-Sun;Lee, Seungok;Jekarl, Dong Wook;Kim, Yonggoo
    • Laboratory Medicine Online
    • /
    • v.7 no.4
    • /
    • pp.163-169
    • /
    • 2017
  • Background: An automated immunohematology analyzer, DAYMATE M (DAY Medical, Switzerland), has been recently developed. The potential of this analyzer to improve test results has been evaluated. Methods: A total of 300 blood samples from Seoul St. Mary's hospital and Incheon St. Mary's hospital were tested for ABO and RhD typing. In addition, 336 antibody screening test (AST) samples and 82 patients treated with hematopoietic stem cell transplantation (HSCT) were included. AST results by DAYMATE M were compared with those obtained by a manual method using DS-Screening II (Bio-Rad Laboratories, Switzerland) and red blood cells from Selectogen (Ortho-Clinical diagnostics Inc., USA). Results: Of the 300 patients enrolled, 87, 73, 79, and 61 had type A, B, O, and AB blood, respectively. The concordance rate was 99.9% for cell typing and 97.0% for serum typing. One discordant case was classified as type B instead of AB, and six discordant serum-typing cases were type A, but classified as type AB. Among the 336 AST samples, the concordance rate was 93.2%. From 136 positive cases, six were discordant. Within the 82 HSCT-treated patients, the concordance rate for ABO blood typing was 92.2%. Among the six discordant cases, DAYMATE M typed four cases as donor type where the standard method typed them as the recipient blood type. Conclusions: The DAYMATE M automated immunohematology analyzer performs reliably for ABO and RhD typing, as well as for ASTs and on samples from patients treated with HSCT.

Evaluation of Norudia® HbA1c Kit for Glycohemoglobin Assay (당화혈색소 측정을 위한 Norudia® HbA1c 키트의 평가)

  • Hong, Seung-Bok;Kim, Eun-Joong
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.41 no.1
    • /
    • pp.37-41
    • /
    • 2009
  • Measurement of hemoglobin A1c is used as an objective indicator of long-term blood glucose control in diabetic patients. We evaluated recently introduced Norudia$^{(R)}$ HbA1c (Daiichi Pure Chemical Co. Ltd, Tokyo, Japan) test reagent using enzyme method for HbA1c assay. Linearity, precision and correlation with VARIANT$^{TM}$ II Turbo HbA1c analyzer (BIO-RAD, Hercules, CA, USA) were evaluated. The reference range was determined from 201 healthy subjects. The Norudia$^{(R)}$ HbA1c test reagent was founded to be linear in a range of 5.6% to 14.0% ($r^2=0.9885$). The within-run and between-day precision were 0.954% and 1.03% for low level (HbA1c 5.24%), 0.67% and 1.28% for high level (HbA1c 9.01%), respectively. Comparison study between Norudia$^{(R)}$ HbA1c test reagent and VARIANT$^{TM}$ II Turbo showed good correlation with a slope of 1.0489. an intercept at -0.9717, and coefficient of correlation was 0.9907. The reference range of HbA1c obtained from this reagent was 4.07-5.50%. The Norudia$^{(R)}$ HbA1c test reagent showed good linearity, precision and correlation with HbA1c analyzer with HPLC method. In addition, the exclusive analyzer is not required for assay and then this kit may be useful for HbA1c assay in clinical laboratory.

  • PDF

A Clinical Case of Oriental Medical Treatment for the Pregnant Woman with HNP at L-spine (임신 중 요추간판 탈출증 환자의 한의학적 치료효과)

  • Park, Min-Jung;Yu, Deok-Seon;Jung, Il-Min;Yeom, Seung-Ryong;Kwon, Young-Dal;Kwon, Young-Mi
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.20 no.4
    • /
    • pp.231-239
    • /
    • 2010
  • Objectives : This study was performed to report the effect and safety of oriental medical treatment in the pregnant woman diagnosed to herniation of nuclues pulposus(HNP) at L5-S1 with central protrusion and left S1 nerve root. Methods : A 32-year old pregnant woman diagnosed HNP at L5-S1 at local hospital was admitted with low back pain and left leg rad pain. We treated her by acupuncture, a herbal medicine, cupping treatment and measured visual analogue scale(VAS), Oswestry disability index(ODI) and Roland-Morris disability qustionnaire(RMDQ) from 5th March 2010 to 26th March 2010. Results : After treatment, most symptoms decreased, VAS score changed 10 to 2, ODI changed 388, RMDQ changed 13 to 6. Conclusions : In this study, oriental medical treatment was effective and safe in pregnant woman with HNP at L-spine. But the rigorous studies will be needed to define clearly that oriental medical treatment is effective and safe in pregnant women with HNP at L-spine.

First Detection of 350 Micron Polarization from 3C 279

  • Lee, Sang-Sung;Kang, Sincheol;Byun, Do-Young;Chapman, Nicholas;Novak, Giles;Trippe, Sascha;Algaba, Juan-Carlos;Kino, Motoki
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.2
    • /
    • pp.36.2-36.2
    • /
    • 2015
  • We report the first detection of linearly polarized emission at an observing wavelength of 350 mum from the radio-loud active galactic nucleus 3C 279. We conducted polarization observations for 3C 279 using the SHARP polarimeter in the Caltech Submillimeter Observatory on 2014 March 13 and 14. For the first time, we detected the linear polarization with the degree of polarization of $13.3%{\pm}3.4%$ (3.9sigma) and the electric vector position angle (EVPA) of $34.^{\circ}7{\pm}5.^{\circ}6$. We also observed 3C 279 simultaneously at 13, 7, and 3.5 mm in dual polarization with the Korean very long baseline interferometry (VLBI) Network on 2014 March 6 (single dish) and imaged in milliarcsecond (mas) scales at 13, 7, 3.5, and 2.3 mm on March 22 (VLBI). We found that the degree of linear polarization increases from 10% to 13% at 13 mm to 350 mum and the EVPAs at all observing frequencies are parallel within < $10^{\circ}$ to the direction of the jet at mas scale, implying that the integrated magnetic fields are perpendicular to the jet in the innermost regions. We also found that the Faraday rotation measures RM are in a range of $-6.5{\times}102{\sim}-2.7{\times}103$ rad m-2 between 13 and 3.5 mm, and are scaled as a function of wavelength:| {RM}| ${\backslash}propto$ {lambda }-2.2. These results indicate that the millimeter and sub-millimeter polarization emission are generated in the compact jet within 1 mas scale and affected by a Faraday screen in or in the close proximity of the jet.

  • PDF

Analysis of Factors Affecting Survival Period in Glioblastoma (교모세포종 환자의 여명에 관련된 인자 분석)

  • Woo, Won Cheol;Song, Shi Hun;Koh, Hyeon Song;Yeom, Jin Young;Kim, Seong Ho;Kim, Youn
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.11
    • /
    • pp.1445-1450
    • /
    • 2000
  • Objectives : The Objective of this study was to analyze the prognostic factors affecting survival in the patients with glioblastomas. Methods : We retrospectively studied 55 consecutive patients with glioblastomas who were admitted to neurosurgery department from January 1988 to March 1998. Fifteen pateients were excluded from the analysis because of follow-up loss and surgical motality. There were 24 male and 16 female patients, with a mean age of 51 years. Surgery consisted of biopsy in 4(10.0%) patients, subtotal resection in 9(22.5%) patients and gross total resection in 27(67.5%) patients. Nine(22.5%) patients received second operation. Twenty-eight(70%) received postoperative radiation therapy. Various levels of radiation dose were used, 6,000 rad over 7 weeks in most cases. The variable factors were examined for their relationship with survival ; age at the time of diagnosis, gender, duration of neurological symptoms, preoperative neurological state(Karnofsky performance score), extent of surgical resection, location of tumor, reoperation, and postoperative radiotherapy and chemotherapy. Result : The mean survival time was 55 weeks, three(7.5%) of the 40 patients survived more than two years. Survival time with biopsy only cases was 24 weeks, for those with subtotal resection 43 weeks, and for those with gross total resection 67 weeks. A mean survival time from the time of reoperation was 42 weeks. Statistically significant survival factors in glioblastoma were extent of surgical resection, postoperative radiotherapy and reoperation. Summary : Results of our series support the views that the extent of surgery, reoperation and postoperative radiation are important prognostic factors. We also recommend radical tumor removal, postoperative radiotherapy and reoperation, if possible.

  • PDF

Evaluation of Radon Levels in Various Public-acess Buildings or Underground Facilities, and Their Temporal Variation in Underground Facilities (다중 이용 건물 또는 지하 실내 공간의 용도에 따른 라돈 오염도 비교와 지하 공간의 시간대별 라돈 농도 변화)

  • Choi, Im-Cho;Shin, Seung-Ho;Jo, Wan-Kuen
    • Environmental Analysis Health and Toxicology
    • /
    • v.24 no.3
    • /
    • pp.203-211
    • /
    • 2009
  • A lesser degree of research is available with respect to indoor radon characteristics associated with occupants' exposure. The present study evaluated the radon levels in several public-access buildings or underground facilities, and their temporal variation in underground facilities. Radon measurements were conducted in 2005 and 2006, utilizing a continuous radon detector. A solid alpha detector (RAD7) was utilized to measure indoor radon levels. The mean radon concentrations obtained from the building or facilities were in a descending order: platforms of Daegu subway line 2, 2005 (32 $Bq/m^3$), hot-air bathroom (14 $Bq/m^3$), basement of office building (14 $Bq/m^3$), underground parking garage (14 $Bq/m^3$), underground shop (12 $Bq/m^3$), nursery (10 $Bq/m^3$), platforms of Daegu subway line 2, 2006 (9.0 $Bq/m^3$), platforms of Daegu subway line 1, 2006 (8.9 $Bq/m^3$), supermarket (7.9 $Bq/m^3$), hospital (7.3 $Bq/m^3$), and second-floor of office building (5.7 $Bq/m^3$). In general, underground-level facilities exhibited higher radon levels as compared with ground-level facilities. It was suggested that ventilation is an important parameter regarding the indoor levels of a subway. There was a decreasing or increasing trend in hourly-radon levels in a subway, whereas no trend were observed in a basement of office building. In addition, the radon levels in the subway lines 1 and 2 varied according to the platforms. The radon levels in the present study were much lower than those of previous studies. The average annual effective dose (AED) of radiation from indoor radon exposure was estimated to be between 0.043 and 0.242 mSv/yr, depending on facility types. These AEDs were substantially lower than the worldwide average AED (2.4 mSv/yr).

The solid angle estimation of acetabular coverage of the femoral head using 3D method (입체각 측정을 통한 대퇴골두에 대한 관골구 coverage 측정)

  • Choi, K.H.;Kim, M.C.;Lim, C.T.;Kim, S.I.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.123-126
    • /
    • 1997
  • We present a method for the estimation of 3D solid angle assessment of the acetabular coverage of the femoral head in 3D space. At first, femoral head and acetabulum is segmented from the original CT scan images. The slice thickness is 1.5mm and the number of slices is usually 30-40 to cover the entire acetabulum. The superior half of the femoral head is modeled as part of a sphere. Thus, the axial cross sections of the upper half of the femoral head are also modeled as circles. A set of points from each outline image of femoral head is fitted recursively into a circle by minimizing root-mean-square (RMS) error. With these fitted circles, a center point of the femoral head model is evaluated. This is a reference point for calculating the solid angle of the acetabular inner surface. Next, the tangent lines connecting from a set of points of the acetabular edge to the center of the fitted sphere are obtained. The lines pass through the unit sphere whose center is the same as that of the femoral head. With the points on the unit sphere, we calculate area and estimate the solid angle. Based on this solid angle, the deformity of the acetabulum is analyzed. In case of normal subject, the solid angle is about 4.3 (rad) and acetabular coverage is 68%.

  • PDF