• 제목/요약/키워드: RVI CVAP

검색결과 30건 처리시간 0.047초

APR1400 원자로내부구조물 종합진동평가프로그램 진동 및 응력해석 방법론 검증 (Validation of Vibration and Stress Analysis Methodology for APR1400 Reactor Vessel Internals Comprehensive Vibration Assessment Program)

  • 김규형;고도영;김성환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.300-305
    • /
    • 2012
  • The vibration and stress analysis program of comprehensive vibration assessment program (CVAP) is to verify theoretically the structural integrity of reactor vessel internals (RVI) and to provide the basis for selecting the locations monitored in measurement and inspection programs. This paper covers the verification of the vibration and stress analysis methodology of APR1400 RVI CVAP. The analysis methodology was developed to use 3-dimensional hydraulic and structural models with ANSYS and CFX. To validate the methodology, the hydraulic loads and structural reponses of OPR1000 were predicted and compared with the calculated and measured data in the OPR1000 RVI CVAP. Since the results predicted with this methodology were close to the measured values considerably, it was confirmed that the analysis methodology was developed properly.

  • PDF

APR1400 상부안내구조물 집합체 구조해석 및 측정위치 (Structural Analysis and Measuring Locations of Upper Guide Structure Assembly in APR1400)

  • 고도영;김규형;김성환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.306-311
    • /
    • 2012
  • A reactor vessel internals comprehensive vibration assessment program (RVI CVAP) of an advanced power reactor 1400 (APR1400) is being performed as a non-prototype category-2 type of reactor based on the US Nuclear Regulatory Commission Regulatory Guide (NRC RG) 1.20. The aim of this paper is to present the results of structural response analysis and measuring locations of a upper guide structure (UGS) assembly of the APR1400 reactor. The analysis results of the UGS assembly results show that meet the specified integrity levels of the design acceptance criteria. Also, the measuring locations are set by the analysis results of the UGS assembly and selection criteria of measuring locations prior to this study. These analysis results and measuring locations will be used as fundamental materials to design a measurement system for the APR1400 RVI CVAP.

  • PDF

APR1400 원자로내부구조물 종합진동평가프로그램 진동 및 응력해석 방법 검증 (Validation of Vibration and Stress Analysis Method for APR1400 Reactor Vessel Internals Comprehensive Vibration Assessment Program)

  • 김규형;고도영;김성환
    • 한국소음진동공학회논문집
    • /
    • 제23권4호
    • /
    • pp.308-314
    • /
    • 2013
  • The vibration and stress analysis program of comprehensive vibration assessment program(CVAP) is to theoretically verify the structural integrity of reactor vessel internals(RVI) and to provide the basis for selecting the locations monitored in measurement and inspection programs. This paper covers the applicability of the vibration and stress analysis method of APR1400 RVI CVAP. The analysis method was developed to use 3-dimensional detail hydraulic and structural models with ANSYS and CFX. To assess the method, the hydraulic loads and structural reponses of OPR1000 were predicted and compared with the measured data in the OPR1000 RVI CVAP. The results predicted with this method were close to the measured values considerably. Therefore, the analysis method was developed properly.

APR1400 상부안내구조물집합체 구조해석 및 측정위치 선정 (Structural Analysis and Measuring Locations of Upper Guide Structure Assembly in APR1400)

  • 고도영;김규형;김성환
    • 한국소음진동공학회논문집
    • /
    • 제23권1호
    • /
    • pp.49-55
    • /
    • 2013
  • A reactor vessel internals comprehensive vibration assessment program(RVI CVAP) of an advanced power reactor 1400(APR1400) is being performed as a non-prototype category-2 type of reactor based on the US nuclear regulatory commission regulatory guide(NRC RG) 1.20. The aim of this paper is to present the results of structural response analysis and measuring locations of a upper guide structure(UGS) assembly of the APR1400 reactor. The analysis results of the UGS assembly show that the specified integrity levels meet the design acceptance criteria. Also, the measuring locations are determined by the analysis results of the UGS assembly and selection criteria of previous study. These analysis results and measuring locations will be used as a guide to design a measurement system for the APR1400 RVI CVAP.

APR1400 미국 설계인증을 위한 종합진동평가 심사서류 작성 방안 (Written Plan of CVAP Design Control Document for APR1400 U.S. Design Certification)

  • 고도영;김동학;박영섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.102-105
    • /
    • 2014
  • In accordance with U.S. Nuclear Regulatory Commission regulatory guide(NRC RG) 1.20(Rev.3), we are writing a comprehensive vibration assessment program(CVAP) design control document(DCD) and a technical report for U.S. NRC design certification(DC) of an Advanced Power Reactor 1400(APR1400) nuclear power plant(NPP). CVAP of an APR1400 NPP for U.S. NRC DC is classified as a non-prototype category 1 type. Therefore, CVAP DCD of reactor vessel internals(RVI) and steam generator internals(SGI) consist of analysis and full inspection program. However, piping system of primary and secondary system will be described as measurement program.

  • PDF

APR+원전 최초 호기의 CVAP 수행에 대한 제언 (Proposal for CVAP of First Plant of APR+ NPP)

  • 김동학;고도영;김만원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.399-401
    • /
    • 2014
  • The comprehensive vibration assessment program(CVAP) of APR+ nuclear power plant(NPP) is classified as non-prototype, category II with Palo Verde NPP as valid prototype. In this paper, CVAP for first plant of APR+ NPP is proposed. The Control Element Assembly(CEA) shroud of APR+ NPP is different from that of Palo Verde NPP. And the Core Support Barrel(CSB) outer diameter and the flow rate of normal operation of APR+ NPP are larger than those of Palo Verde NPP. Vibration and stress analysis program should be conducted to establish test acceptance criteria. Limited vibration measurement program should be implemented to establish the margin of safety, demonstrate the satisfaction of test acceptance criteria and confirm the similar vibratory response between the APR+ and Palo Verde NPP. Because of the change of normal operation condition, the nominal differences between APR+ and Palo Verde NPP in the structural and hydraulic analysis are studied to determine the measurement locations.

  • PDF

원자로 내부배럴집합체 상부면 측정위치 선정 (Selection of Measurement Locations at Inner Barrel Assembly Top Plate in the Reactor)

  • 고도영;김규형;김성환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.734-738
    • /
    • 2012
  • A comprehensive vibration assessment program for the Advanced Power Reactor 1400 reactor vessel internals is established in accordance with the United States Nuclear Regulatory Commission Regulatory Guide 1.20 Revision 3. This paper is related to instruments and measurement locations based on the vibration and stress response analysis results at the inner barrel assembly top plate in the reactor. The analysis results of the inner barrel assembly top plate in the reactor show that the deterministic stress and deformation due to the reactor coolant pump induced pressure pulsations are larger than the random stress and deformation induced by the flow turbulence. The selection of the instruments and measurement locations at Inner barrel assembly top plate in the reactor is essential requirements and very important study process for the vibration and stress measurement program in comprehensive vibration assessment program for the Advanced Power Reactor 1400 reactor vessel internals.

  • PDF

APR1400 내부배럴집합체 상부판 구조해석 및 측정위치 (Structural Analysis and Response Measurement Locations of Inner Barrel Assembly Top Plate in APR1400)

  • 고도영;김규형;김성환
    • 한국소음진동공학회논문집
    • /
    • 제22권5호
    • /
    • pp.474-479
    • /
    • 2012
  • A comprehensive vibration assessment program for the advanced power reactor 1400(APR1400) reactor vessel internals is established in accordance with the united states nuclear regulatory commission regulatory guide 1.20 revision 3. This paper is related to instruments and measurement locations based on the vibration and stress response analysis results of the inner barrel assembly top plate in APR1400. The analysis results of the inner barrel assembly top plate in the reactor show that the deterministic stress and deformation due to the reactor coolant pump induced pressure pulsations are larger than the random stress and deformation induced by the flow turbulence. The selection of the instruments and measurement locations at inner barrel assembly top plate in the reactor is essential requirements and very important study process for the vibration and stress measurement program in comprehensive vibration assessment program for APR1400 reactor vessel internals.