• 제목/요약/키워드: RTD sensor

검색결과 41건 처리시간 0.033초

상 변화방식 마이크로 액츄에이터의 제조 및 성능에 관한 연구 (The fabrication and characterization of a phase change type micro actuator)

  • 박승인;황준영;이상호;강경태;강희석;강신일
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1433-1438
    • /
    • 2007
  • Characteristics of a phase change type micro actuator have been studied. The micro actuator has been designed for a micro-pump in an active direct methanol fuel cell(DMFC), consisting of an actuating chamber, a membrane, an electric heater, and a sensor of resistance temperature detector (RTD). In the present study, researches have been focused on the response of the actuator to control algorithm of the heater. The experiments demonstrated that the displacement of the membrane increase with temperature variation which is a function of applied voltage, duty ratio, and operating frequency of heating. The results also showed that operation of the actuator with high voltage at small duty of heating is more efficient than the same power consumption of heating with low voltage at large duty.

  • PDF

고압 회전기의 절연열화 진단을 위한 운전중 부분방전 측정 센서의 특성분석 (Characteristics Analysis of On-Line Partial Discharge Measurement Sensor for Insulation Diagnosis of HV Rotating Machines)

  • 윤대희;황돈하;김용주;이광식;김희동;김정우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1909-1911
    • /
    • 2000
  • Recently many research activities on the diagnosis of stator winding insulation of large rotating machines have been reported. Capacitive couplers are widely used as sensors for on-line partial discharge (PD) measurement of high voltage rotating machines. This paper presents laboratory test to compare Stator Slot Coupler (SSC), Resistance Temperature Detector (RTD), 80 [pF] coupler and 500 [pF] coupler for on-line PD measurement of rotating machines.

  • PDF

마이크로컴퓨터 시스템을 이용한 CA 저장 중 사과의 증산속도 측정 (Measurement of Transpiration Rate of Apple with a Microcomputer-Based Data Acquisition System during CA Storage)

  • 강준수;서명교
    • 한국식품저장유통학회지
    • /
    • 제1권1호
    • /
    • pp.37-43
    • /
    • 1994
  • A microcomputer system consisting of 16-bit microcomputer, PCL-711S interface board, censors, and converters have been set up in order to automatically measure temperature, humidity and weight loss which are major variables of storage of apple. This system was operated by PC-LabDAS software. It has been possible to measure continuously the weight loss of Fuji apple stored in CA with the weight converter made by a miniature load cell and a strain amplifier. The temperature was checked by a k-type thermocouple and Pt 100 $\Omega$ RTD, and humidity by PQ653JAl humidity sensor. It has been possible to set up a linear equation which showers high correlationship between the estimate of temperature, weight humidity and the output of the converter in that r2 is more than 0.99. Transpiration rate, a significant factor of quality deterioration for CA storage of apple, can be estimated with these values.

  • PDF

접촉력 보정이 가능한 열적 방식의 혈류량 측정기 (A Thermal Blood Flow Sensor with Contact Force Compensation)

  • 심재경;윤세찬;조영호
    • 대한기계학회논문집B
    • /
    • 제37권3호
    • /
    • pp.237-242
    • /
    • 2013
  • 본 논문은 접촉력 보정이 가능한 혈류량 측정기를 제안한다. 기존 혈류량 측정기는 접촉력의 영향을 최소화하기 위해 혈류량 센서를 피부에 고정했으나 이런 점은 전자기기에 적용이 용이하지 않다는 단점이 있다. 이에 본 연구에서는 혈류량 센서에 힘 센서를 집적하여 혈류량과 접촉력의 동시 측정을 통해 접촉력에 따른 혈류량 변화 오차를 보정하여 접촉력에 무관한 혈류량 측정이 가능한 소자 및 방법을 제안한다. 제작된 혈류량 측정기의 성능 분석 결과, 접촉력에 따른 혈류량 변화는 31.7%/N 의 선형적 감소경향임을 확인하였고, 이를 이용하여 접촉력에 따른 혈류량 오차를 보정한 결과, 접촉력 1~3N에서 최대 편차가 9.8%로 나타나 다른 접촉력 조건에서도 일정한 혈류량 측정이 가능함을 보였다. 제안한 소자는 접촉력에 무관하게 정확한 혈류량을 측정할 수 있어, 접촉 가능한 전자기기에의 적용이 용이하다.

6.6 kV 케이블의 절연저항 측정을 위한 부하전류 및 온도 측정 (Load Current and Temperature Measurement for Measuring the Insulation Resistance of the 6.6 kV Cable)

  • 박용규;조영식;이관우;엄기홍;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제28권1호
    • /
    • pp.46-50
    • /
    • 2015
  • The cable degradation process is largely divided into three steps; Step 1 : Thermal degradation, Step 2 : Weibull degradation, Step 3 : Partial discharge. it is progress in step order. This article aims to explain the process of cable degradation using the method of insulation resistance and accordingly to compose and manufacture a system of measuring the life of electrical cable. Before measuring the insulation resistance, a system of measuring the temperature and current of cables was made, and the established system was installed for test on the site of a power plant to collect the measured data. The current sensor was used TFC30P80A-CL420, and temperature sensor was used the DK-1270 PT100 sensor as RTD sensor. When measured the temperature and the load current at the same position, was confirmed that in case of the load current value was high, also temperature value high. Therefore, the correlation between load currents and temperature was verified, and the analysis of diagnostic data was evaluated, which could be utilized in identifying the fault condition of cable systems.

상변화를 이용한 열공압형 마이크로 펌프용 액츄에이터 성능에 관한 연구 (A study on the Thermopneumatic Actuator with Phase Change for Micro Pump)

  • 박승인;황준영;이상호;강경태;강희석;장재혁;이홍렬;강신일
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.425-428
    • /
    • 2006
  • Recently, Direct Methanol Fuel Cell (DMFC) for portable devices has been received much attention because DMFC has a possibility of higher energy density than electrical batteries and smaller size than other fuel cells. This paper presents the fabrication and test of a thermopneumatic microactuator with a phase change for DMFC. A microactuator consists of an inlet an outlet a chamber, a heater and a sensor of resistance temperature detector(RTD). The micoractuator is fabricated by the spin-coating process, the lithograph process, the deep RIE process and so on. The total size of microactuator is $20{\times}20{\times}0.53mm^3$. When the current is applied, the heater heats liquid in chamber. As a result the liquid vaporizes. The response of temperature in the chamber was measured using thermocouple The changed temperature is $3^{\circ}C$ for 5 sec at 0.032W.

  • PDF

온도센서를 이용한 CO2레이저 빔 조사면의 온도 분포 특성에 관한 연구 (The study on temperature distribution characteristic of irradiated surface by CO2 laser)

  • 민병대;김태균;정현주;김용철;정종한;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1831-1833
    • /
    • 2003
  • Nowadays, CO2 lasers are used widely in many applications such as materials fabrication, communications, remote sensing and military purpose etc. Especially, CO2 lasers are in the spotlight at surface handling and heat processing. It is important to control the laser output power and beam quality in those fields. To increase beam qualify, We used the feedback system by various sensors. Although, CO2 lasers' output beam became feedback, its beam affected the irradiated material target already. Since, ideal real time control have still the problem to solve. Hence, we need the new proposal for more precise laser processing. So we expect the new effect how to change the irradiated material target as the kind of, processing time and output density caused by the CO2 laser beam. In this study, We have investigated the characteristics of the temperature and HAZ(Heat Affected Zone) by CO2 laser output with IR temperature sensor and RTD.

  • PDF

테프론 코팅 전열관 표면으로의 열 및 물질 전달 특성에 관한 실험적 연구 (Experimental Study on the Characteristics of Heat and Mass Transfer on the Teflon Coated Tubes)

  • 이장호;김형대;김정배;김무환
    • 대한기계학회논문집B
    • /
    • 제27권8호
    • /
    • pp.1051-1060
    • /
    • 2003
  • The heat and mass transfer on two kinds of tube surfaces (bare stainless steel tube and Teflon coated tube) in steam-air mixture flow are experimentally studied to obtain design data for the heat exchanger of the latent heat recovery from flue gas. In the test section, 3-tubes are horizontally installed, and steam-air mixture is vertically flowed from the top to the bottom. The pitch between tubes is 67mm, the out-diameter of tube is 25.4mm, and the thickness is 1.2mm ; blockage factor (cross sectional tube area over the cross sectional area of the test section) is about 0.38. All of sensors and measurement systems (RTD, pressure sensor, flow-meter, relative humidity sensor, etc.) are calibrated with certificated standard sensors and the uncertainty for the heat transfer measurement is surveyed to have the uncertainty within 7%. As experimental results, overall heat transfer coefficient of the Teflon (FEP) coated tube is degraded about 20% compared to bare stainless tube. The degradation of overall heat transfer coefficient of Teflon coated tube comes from the additional heat transfer resistance due to Teflon coating. Its magnitude of heat transfer resistance is comparable to the in-tube heat transfer resistance. Nusselt and Sherwood numbers on Teflon (FEP) coated surface and bare stainless steel surface are discussed in detail with the contact angles of the condensate.

알루미늄산화막을 매개층으로 이용한 백금 미세발열체의 특성 (The Characteristics of Pt Micro Heater Using Aluminum Oxide as Medium Layer)

  • 정귀상;노상수;최영규;김진한
    • 센서학회지
    • /
    • 제6권5호
    • /
    • pp.400-406
    • /
    • 1997
  • DC 마그네트론 스퍼터링 반응성 스퍼터링으로 각각 증착된 알루미늄산화막과 그 위에 증착된 Pt 박막의 열처리 온도에 따른 전기적, 물리적 특성을 4침 탐침기, 주사전자현미경 및 X선 회절법을 이용하여 분석하였다. $600^{\circ}C$ 이하의 열처리 조건에서는 알루미늄산화막은 Pt 박막과 화학적 반응 없이 Pt 박막의 $SiO_{2}$에 대한 부착특성을 개선시켰으며 그 위에 증착된 Pt 박막의 전기적 특성도 열처리 온도가 증가함에 따라 개선되었다. 그러나 $700^{\circ}C$ 이상의 열처리 온도에서는 알루미늄산화막이 절연특성이 저하되고 그 위에 증착된 Pt 박막과 반응하여 Pt 박막의 전 기적 특성도 저하되었다. Pt-RTD 온도센서를 이용한 Pt 미세발열체의 발열특성 분석에서 활성영역이 작을 수록 발열체의 발인특성이 개선되었으며 활성영역 면적이 $200{\mu}m{\times}200{\mu}m$의 구조를 갖는 Pt 미세발열체는 소비전력 1.5watts에 $400^{\circ}C$ 정도의 양호한 발열특성을 나타냈다.

  • PDF

볼트풀림에 의한 터미널 블록의 접속부 발열 위험성 분석 (Analysis of the Risk of Heat Generation due to Bolt Loosening in Terminal Block Connector Parts)

  • 연영모;김승희
    • 한국화재소방학회논문지
    • /
    • 제34권3호
    • /
    • pp.67-75
    • /
    • 2020
  • 본 연구는 산업현장에서 사용되는 분전반 내 터미널 블록의 탄화 사고를 예방하기 위한 목적으로, 전선 접속부 볼트의 이상(Abnormal) 풀림 각도에 따라 변화하는 정상전류 및 과전류의 접속부 발열 위험성을 확인하고 열적 특성을 통해 위험성을 분석하였다. 이를 위하여 터미널 블록에 Resistance temperature detector (RTD) 센서 보드를 설치하여 실시간으로 터미널 블록의 발열 온도와 온도의 변화를 측정하는 새로운 기법을 적용하였다. 실험 결과 정격 전류가 작은 터미널 블록 모델의 발열 온도가 높게 나타남에 따라 부하전류에 따른 터미널 블록 용량 선정의 중요성을 확인하였다. 또한 정격전류가 높은 터미널 블록의 정격 전류가 높을수록, 이상 풀림 정도가 클수록 탄화점이 빨라짐을 확인하였다. 이러한 발열 온도 모니터링을 통해서 실시간 발열 온도를 측정할 수 있었고 열적 분석을 통해서 단계별 위험수위 설정이 가능함을 확인할 수 있었다. 본 연구의 탄화 위험성 측정 및 분석 결과는 탄화로 인한 화재 위험성에 대한 응용 연구의 이론적 기초를 제공할 수 있다. 또한 본 연구에서 새롭게 적용한 온도 센서 보드를 활용한 열화 측정 방법은 위험수준관리 및 전기적 접촉 불량으로 인한 화재 예방 활동에 광범위하게 적용 가능할 것으로 사료된다.