• Title/Summary/Keyword: RT3D model

Search Result 48, Processing Time 0.023 seconds

Estimated Risk of Radiation Induced Contra Lateral Breast Cancer Following Chest Wall Irradiation by Conformal Wedge Field and Forward Intensity Modulated Radiotherapy Technique for Post-Mastectomy Breast Cancer Patients

  • Athiyaman, Hemalatha;M, Athiyaman;Chougule, Arun;Kumar, HS
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.12
    • /
    • pp.5107-5111
    • /
    • 2016
  • Background: Epidemiological studies have indicated an increasing incidence of radiation induced secondary cancer (SC) in breast cancer patients after radiotherapy (RT), most commonly in the contra-lateral breast (CLB). The present study was conducted to estimate the SC risk in the CLB following 3D conformal radiotherapy techniques (3DCRT) including wedge field and forward intensity modulated radiotherapy (fIMRT) based on the organ equivalent dose (OED). Material and Methods: RT plans treating the chest wall with conformal wedge field and fIMRT plans were created for 30 breast cancer patients. The risks of radiation induced cancer were estimated for the CLB using dose-response models: a linear model, a linear-plateau model and a bell-shaped model with full dose response accounting for fractionated RT on the basis of OED. Results: The plans were found to be ranked quite differently according to the choice of model; calculations based on a linear dose response model fIMRT predict statistically significant lower risk compared to the enhanced dynamic wedge (EDW) technique (p-0.0089) and a non-significant difference between fIMRT and physical wedge (PW) techniques (p-0.054). The widely used plateau dose response model based estimation showed significantly lower SC risk associated with fIMRT technique compared to both wedge field techniques (fIMRT vs EDW p-0.013, fIMRT vs PW p-0.04). The full dose response model showed a non-significant difference between all three techniques in the view of second CLB cancer. Finally the bell shaped model predicted interestingly that PW is associated with significantly higher risk compared to both fIMRT and EDW techniques (fIMRT vs PW p-0.0003, EDW vs PW p-0.0032). Conclusion: In conclusion, the SC risk estimations of the CLB revealed that there is a clear relation between risk associated with wedge field and fIMRT technique depending on the choice of model selected for risk comparison.

Low polygon game character modeling and Character Primitives manufacture (로우폴리곤 게임 캐릭터 모델링 및 Character Primitives 제작)

  • Kang, Sung-Jung;Kim, Sang-Jin;Lee, Seung-Hyun
    • Journal of the Korea Computer Industry Society
    • /
    • v.7 no.5
    • /
    • pp.573-582
    • /
    • 2006
  • The game is in progress according to the game story with the text, graphic, animation, motion picture, music, etc. Also the result of the game varies depending on the strategy and tactics of the player. For the development of the game, this paper describes the task of the game planner, game programmer, and game graphic designer. Game graphic designers are classified into 4 parts such as the art director, original picture designer, 2D designer, and 3D designer. Among these, the 3D designer makes the 3D game characters with the use of 3D tools. This paper presents the method that 3D designers and beginners can develop 3D characters easily and quickly, Also, this paper shows the method for making preparations of SourceModel which includes 150 polygons. The SourceModel is made up of between five life size and eight life size. In addition, Character Primitives Interface is made to use SourceModel in MaxScript. Accordingly 3D designers have the free use of SourceModel and they will be able to save time.

  • PDF

Manikin Model Study on Reproducibility and Accuracy of Maxillofacial Measurements Determined by Stereocamera: Comparative Study of Direct Anthropometry, Digitizer and Stereophotogrammetery (스테레오 카메라를 이용한 안면부 측정의 재현성과 정확도에 대한 마네킨을 이용한 연구: 직접 인체계측, Digitizer, Stereophotogrammetry의 비교 연구)

  • Jeoung, Youn-Wook;Yang, Ji-Woong;Chung, Kwang;Kook, Min-Suk;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.1
    • /
    • pp.17-25
    • /
    • 2012
  • Purpose: Recently, a three dimensional approach to hard and soft tissues of the maxillofacial area has been widely used. This study was to evaluate the reproducibility and accuracy of a stereocamera compared to actual measurement methods using a digital caliper and digitizer. Methods: The stereoscopies of 7 head dummies with different sizes and shapes were obtained using a Di3D system (Dimensional Imaging, Glasgow, UK) after marking reference points on facial areas. From the obtained stereoscopy, 10 measurements representing the width, height and depth of each of the facial sections of the dummy were measured twice using a three dimensional reverse engineering software program (RapidForm$^{TM}$ 2006, Inus, Seoul, Korea). The x, y, and z coordinates of each of the three dimensional measurements were obtained and distances between two points were calculated. All procedures were repeated twice. The actual measurement method was performed twice, directly on dummies, using a digital caliper and values were compared with the previously determined values. Results: The results were as follows. In the ANOVA analysis, there were no significant statistical differences among the three measurement methods. In the Bonferroni analysis, with adjustments applied for multiple comparisons, there was no difference between actual measurement methods using a digitizer and a digital caliper. However, there was some difference between using a stereocamera and actual measurement methods using a digitizer and a digital caliper in values of $Ex_{Rt}-Ex_{Lt}$, $En_{Rt}-En_{Lt}$, $Ala_{Rt}-Ala_{Lt}$, $Ch_{Rt}-Ch_{Lt}$, G-Pg', $Ala_{Rt}$-Prn, $Ala_{Rt}$-Prn. The mean value for technical error in measurement (TEM) in Di3D (0.98 mm) was slightly higher than for a digital caliper (0.17 mm) and a digitizer (0.30 mm). In an intraclass correlation coefficient (ICC) there were no significant differences among the three measurement methods, but the Di3D system with the stereocamera showed relatively lower reproducibility compared to actual measurement methods using a digitizer and a digital caliper. Conclusion: These results indicate that some complementary measures may be needed to improve accuracy and reproducibility in the Di3D system with stereocamera.

A study of facial soft tissue of Korean adults with normal occlusion using a three-dimensional laser scanner (3차원 레이저 스캐너를 이용한 한국 성인 정상교합자의 안면 연조직에 대한 연구)

  • Baik, Hyoung-Seon;Jeon, Jai-Min;Lee, Hwa-Jin
    • The korean journal of orthodontics
    • /
    • v.36 no.1 s.114
    • /
    • pp.14-29
    • /
    • 2006
  • Developments in computer technology have made possible the 3-dimensional (3-D) evaluation of hard and soft tissues in orthodontic diagnosis, treatment planning and post-treatment results. In this study, Korean adults with normal occlusion (male 30, female 30) were scanned by a 3-D laser scanner, then 3-D facial images formed by the Rapidform 2004 program (Inus Technology Inc., Seoul, Korea.). Reference planes in the facial soft tissue 3-D images were established and a 3-D coordinate system (X axis-left/right, Y axis-superior/inferior, Z axis-anterior/posterior) was established by using the soft tissue nasion as the zero point. Twenty-nine measurement points were established on the 3-D image and 43 linear measurements, 8 angular measurements, 29 linear distance ratios were obtained. The results are as follows; there were significant differences between males and females in the nasofrontal angle $(male:\;142^{\circ},\;female:\;147^{\circ})$ and transverse nasal prominence $(male:\;112^{\circ},\;female:\;116^{\circ})$ (p<0.05). The transverse upper lip prominence was $107^{\circ}$ in males, $106^{\circ}$ in females and the transverse mandibular prominence was $76^{\circ}$ in both males and females. Li-Me' was 0.4 times the length of Go-Me'(mandibular body length) and the mouth height was also 0.4 times the width of the mouth width. The linear distance ratio from the coronal reference plane of FT, Zy, Pn, ULPm, Li, Me' was -1/-1/1/0.5/0.5/-0.6 respectively. The 3-D facial model of Korean adults with normal occlusion were be constructed using coordinate values and linear measurement values. These data may be used as a reference in 3-D diagnosis and treatment planning for malocclusion and dentofacial deformity patients and applied for 3-D analysis of facial soft tissue changes before and after orthodontic treatment and orthognathic surgery.

Surveying and Optimizing the Predictors for Ependymoma Specific Survival using SEER Data

  • Cheung, Min Rex
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.2
    • /
    • pp.867-870
    • /
    • 2014
  • Purpose: This study used receiver operating characteristic curve to analyze Surveillance, Epidemiology and End Results (SEER) ependymoma data to identify predictive models and potential disparity in outcome. Materials and Methods: This study analyzed socio-economic, staging and treatment factors available in the SEER database for ependymoma. For the risk modeling, each factor was fitted by a Generalized Linear Model to predict the outcome ('brain and other nervous systems' specific death in yes/no). The area under the receiver operating characteristic curve (ROC) was computed. Similar strata were combined to construct the most parsimonious models. A random sampling algorithm was used to estimate the modeling errors. Risk of ependymoma death was computed for the predictors for comparison. Results: A total of 3,500 patients diagnosed from 1973 to 2009 were included in this study. The mean follow up time (S.D.) was 79.8 (82.3) months. Some 46% of the patients were female. The mean (S.D.) age was 34.4 (22.8) years. Age was the most predictive factor of outcome. Unknown grade demonstrated a 15% risk of cause specific death compared to 9% for grades I and II, and 36% for grades III and IV. A 5-tiered grade model (with a ROC area 0.48) was optimized to a 3-tiered model (with ROC area of 0.53). This ROC area tied for the second with that for surgery. African-American patients had 21.5% risk of death compared with 16.6% for the others. Some 72.7% of patient who did not get RT had cerebellar or spinal ependymoma. Patients undergoing surgery had 16.3% risk of death, as compared to 23.7% among those who did not have surgery. Conclusion: Grading ependymoma may dramatically improve modeling of data. RT is under used for cerebellum and spinal cord ependymoma and it may be a potential way to improve outcome.

Ag(100) 기판위에 증착된 Nb Cluster에 관한 STM연구

  • 윤홍식;유미애;한권환;이준희;양경득;여인환
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.140-140
    • /
    • 2000
  • The initial growth mode of Nb on Ag(11) in sub-monolayer regime and the influence of subsequent 520K annealing are studied using UHV Scanning Tunneling Microscopy. E-beam evaporated Nb is deposited onto the substrate at RT, and STM measurements are carried out at RT and 78 K. With Nb being immiscible in bulk Ag, 3D islands formation begins at early stage and no particular ordered structure is found. After annealing to 520K, most of islands are disappeared from terrace. There exist 2 possibilities. : (1) Diffusion of Nb into the 2nd or 3rd layer of Ag substrate or (2) agglomeration of Nb on Ag at higher temperature. A model will be given to explain the evidence. In addition, we investigated the change of STM image according to bias voltage depending on island size. Possible physical mechanism responsible for such behavior together with interaction between Nb islands and reactive gases will be also discussed.

  • PDF

Circ_UBE2D2 Attenuates the Progression of Septic Acute Kidney Injury in Rats by Targeting miR-370-3p/NR4A3 Axis

  • Huang, Yanghui;Zheng, Guangyu
    • Journal of Microbiology and Biotechnology
    • /
    • v.32 no.6
    • /
    • pp.740-748
    • /
    • 2022
  • As circ_UBE2D2 has been confirmed to have targeted binding sites with multiple miRNAs involved in septic acute kidney injury (SAKI), efforts in this study are directed to unveiling the specific role and relevant mechanism of circ_UBE2D2 in SAKI. HK-2 cells were treated with lipopolysaccharide (LPS) to construct SAKI model in vitro. After sh-circ_UBE2D2 was transfected into cells, the transfection efficiency was detected by qRT-PCR, cell viability and apoptosis were determined by MTT assay and flow cytometry, and expressions of Bcl-2, Bax and Cleaved-caspase 3 were quantified by western blot. Target genes associated with circ_UBE2D2 were predicted using bioinformatics analysis. After the establishment of SAKI rat model, HE staining and TUNEL staining were exploited to observe the effect of circ_UBE2D2 on tissue damage and cell apoptosis. The expression of circ_UBE2D2 was overtly elevated in LPS-induced HK-2 cells. Sh-circ_UBE2D2 can offset the inhibition of cell viability and the promotion of cell apoptosis induced by LPS. Circ_UBE2D2 and miR-370-3p as well as miR-370-3p and NR4A3 have targeted binding sites. MiR-370-3p inhibitor reversed the promoting effect of circ_UB2D2 silencing on viability of LPS-treated cells, but shNR4A3 neutralized the above inhibitory effect of miR-370-3p inhibitor. MiR-370-3p inhibitor weakened the down-regulation of NR4A3, Bax and Cleaved caspase-3 and the up-regulation of Bcl-2 induced by circ_UB2D2 silencing, but these trends were reversed by shNR4A3. In addition, sh-circ_UBE2D2 could alleviate the damage of rat kidney tissue. Circ_UBE2D2 mitigates the progression of SAKI in rats by targeting miR-370-3p/NR4A3 axis.

Effect of Deer Antler Extract on Muscle Differentiation and 5-Aminoimidazole-4-Carboxamide Ribonucleoside (AICAR)-Induced Muscle Atrophy in C2C12 Cells

  • Jo, Kyungae;Jang, Woo Young;Yun, Beom Sik;Kim, Jin Soo;Lee, Hyun-Sun;Chang, Yeok Boo;Suh, Hyung Joo
    • Food Science of Animal Resources
    • /
    • v.41 no.4
    • /
    • pp.623-635
    • /
    • 2021
  • The effect of deer antler extract on muscle differentiation and muscle atrophy were evaluated to minimize muscle loss following aging. Various deer antler extracts (HWE, hot water extract of deer antler; FE, HWE of fermented deer antler; ET, enzyme-assisted extract of deer antler; UE, extract prepared by ultrasonication of deer antler) were evaluated for their effect on muscle differentiation and inhibition of 5-aminoimidazole-4-carboxamide ribonucleoside (AICAR)-induced muscle atrophy in C2C12 cells. Morphological changes according to the effect of antler extracts on muscle differentiation were confirmed by Jenner-Giemsa staining. In addition, the expression levels of genes related to muscle differentiation and atrophy were confirmed through qRT-PCR. In the presence of antler extracts, the length and thickness of myotubes and myogenin differentiation 1 (MyoD1) and myogenic factor 5 (Myf5) gene expression were increased compared to those in the control group (CON). Gene expression of AMP-activated protein kinase (AMPK), MyoD1, and myogenin, along with the muscle atrophy factors muscle RING finger-1 (MuRF-1) and forkhead box O3a (FoxO3a) upon addition of deer antler extracts to muscle-atrophied C2C12 cells was determined by qRT-PCR after treatment with AICAR. The expression of MuRF-1 and FoxO3a decreased in the groups treated with antler extracts compared to that in the group treated with AICAR alone. In addition, gene expression of MyoD1 and myogenin in the muscle atrophy cell model was significantly increased compared that into the CON. Therefore, our findings indicate that antler extract can increase the expression of MyoD1, Myf5 and myogenin, inhibit muscle atrophy, and promote muscle differentiation.

New Model of In-situ Xenograft Lymphangiogenesis by a Human Colonic Adenocarcinoma Cell Line in Nude Mice

  • Sun, Jian-Jun;Jing, Wei;Ni, Yan-Yan;Yuan, Xiao-Jian;Zhou, Hai-Hua;Fan, Yue-Zu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.6
    • /
    • pp.2823-2828
    • /
    • 2012
  • Objective: To explore a new model of in-situ xenograft lymphangiogenesis of human colonic adenocarcinomas in nude mice. Method: On the basis of establishing subcutaneous xenograft lymphangiogenesis model of human colonic adenocarcinoms, in-situ xenografts were established through the in situ growth of the HT-29 human colonic adenocarcinoma cell line in nude mice. The numbers of lymphangiogenic microvessels, the expression of lymphatic endothelial cell markers lymphatic vessel endothelial hyaloronic acid receptor-1 (LYVE-1), D2-40 and the lymphatic endothelial growth factors vascular endothelial growth factor-C (VEGF-C), -D (VEGF-D) and receptor-3 (VEGFR-3) were compared by immunohistochemical staining, Western bolt and quantitative RT-PCR in xenograft in-situ models. Results: Some microlymphatics with thin walls, large and irregular or collapsed cavities and increased LMVD, with strong positive of LYVE-1, D2-40 in immunohistochemistry, were observed, identical with the morphological characteristics of lymphatic vessels and capillaries. Expression of LYVE-1 and D2-40 proteins and mRNAs were significantly higher in xenograpfts in-situ than in the negative control group(both P<0.01). Moreover, the expression of VEGF-C, VEGF-D and VEGFR-3 proteins and mRNAs were significantly higher in xenografts in-situ (both P<0.01), in conformity with the signal regulation of the VEGF-C,-D/VEGFR-3 axis of tumor lymphangiogenesis. Conclusions: In-situ xenografts of a human colonic adenocarcinoma cell line demonstrate tumor lymphangiogenesis. This novel in-situ animal model should be useful for further studying mechanisms of lymph node metastasis, drug intervention and anti-metastasis therapy in colorectal cancer.

Effects of the Complexity of 3D Modeling on the Acoustic Simulations and Auralized Sounds (3D 모델의 구체성이 건축음향 시뮬레이션 및 가청화시재에 미치는 영향)

  • Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.1
    • /
    • pp.22-32
    • /
    • 2011
  • The present study examined the effects of the complexity of the 3D models on the results of acoustic simulation which is the predominant tool of the acoustical design of buildings. Also, the effects of the 3D model on the auralized sounds were investigated. In order to carry out the study, four 3D models with different levels of complexity were introduced for a real auditorium which have different numbers of surfaces in the persuit of the guidance of odeon room acoustic software. The set-up of models was also based on the level of transition order of the program. And the acoustic experiments were performed measuring room acoustic parameters including SPL, RT, C80, D50. Acoustic computer simulations were performed using four different models. Then, the results of the computer modeling were compared with the measured acoustical parameters. In addition, sound sources were recorded in the field and auralized sounds were made in convolution with the impulse source made from acoustic modeling. Then, subjective tests were undertaken using auralized sounds. As the results, it was found that the result of the acoustic simulation were closer to the real room acoustic properties when 3D model was more particularly made. For the subjective test, the listening materials were acknowledged as similar with the real sound source when more complex 3D model was used. Then, it could be concluded that the complexity of the 3D model affects the results of the acoustic modeling as well as subjective tests.