• Title/Summary/Keyword: RSD

Search Result 533, Processing Time 0.025 seconds

Analysis of Mono-, Di- and Tri-glycerides by high-performance liquid chromatography (HPLC) with evaporative light scattering detection (ELSD) (HPLC/ELSD에 의한 Mono-, Di- 및 Tri-glycerides류 분석)

  • Lee, Man-Ho;Park, Heai-Ku;Kim, In-Whan
    • Analytical Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.189-193
    • /
    • 2006
  • Chromatographic separation of glycerol monostearate, glycerol distearate and glycerol tristearate (GMS, GDS, and GTS) has been performed by normal phase HPLC method utilizing a Zorbax silica ($250{\times}4.6mm$, $5{\mu}m$) column and hexane-hexane, IPA and ethyl acetate mixtures as the eluent within 20 min. The observed reproducibility was less than 5% RSD, Suggesting that ELSD was an effective tool for detection of the glycerol stearates of low volatility without chromophore. The detection limits were in the concentration range of 0.3~2 mg/L, and the calibration curves (the log-log plots) were linear in the range of 4~1000 mg/L (with the slopes of 1.06~1.32). The application of the analytical procedure without pretreatment demonstrated that the proposed chromatographic method would be practical for a routine analysis of commercial products.

Determination of selenium in milk powder by octopole reaction cell ICP-MS (Octopole Reaction Cell이 장착된 ICP-MS에 의한 분유 중 셀레늄의 정량)

  • Cho, Sung-Eel;Kim, Mi-Ju;Kim, Yong-Ha;Min, Young-Keun;Kim, Young-Sang
    • Analytical Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.203-210
    • /
    • 2006
  • The determination of trace selenium in milk powder has been studied by octopole reaction cell(ORC)-ICP-MS. The interferences by polyatomic ions and other concomitant molecular species could be removed remarkably by using $H_2$ as reaction gas in ORC. Compared to the normal mode (no cell gas), the $H_2$ cell gas mode improved the accuracy and precision. The quantitative result was average 102.7% and it was slightly higher than certified standard value of milk powder and the RSD was 7.6%.

Determination of osmium using sulfurous acid as reductant by ICP-AES (Sulfurous acid 환원제를 이용한 ICP-AES에 의한 Osmium의 정량 분석)

  • Park, Han-Seok;Kim, Kang-Jin
    • Analytical Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.251-254
    • /
    • 2007
  • In this study, a convenient, fast and accurate inductively coupled plasma atomic emission spectrometry (ICP-AES) method has been optimized for the determination of osmium in aqueous solutions. The method makes use of the reaction of sulfurous acid with osmium to quantitative conversion of volatile Os(VIII) to non-volatile Os(IV) in the pH range 2-10. The response was found to be stabilized immediately after sulfurous acid reacted with osmium. The precision was calculated to be 0.5-4.5 % (RSD) under various ICP-AES conditions. The detection limit was 2.5-57.7 ng/g based on $3{\sigma}$ of the blank response (n=3) using a concentric flow nebulization.

Validation of the Analytical Procedure for Quantitative Determination of Four Trace Metals (As, Cd, Pb, and Hg) in Fish Lipids Using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS)

  • Kasun S. Jayakody;Ranjith K. B. Edirisinghe;Suchithra A. Senevirathne;Lalith Senarathna
    • Mass Spectrometry Letters
    • /
    • v.15 no.3
    • /
    • pp.149-157
    • /
    • 2024
  • The objective of the present study was to validate the analytical procedure for the quantitative determination of four trace metals (As, Cd, Pb, and Hg) in extracted fish lipids using Inductively Coupled Plasma-Mass Spectrometry, ICP-MS. The extracted lipids using Bligh and Dyer method were digested by means of microwave-assisted acid digestion and introduced into an optimized ICP-MS instrument. The validation of the analytical method was carried out in accordance with the international standards and guidelines outlined in the European Pharmacopeia (2022), which included specificity, selectivity, linearity, limit of detection, limit of quantification, precision, and accuracy. The linearity ranges of the calibration curves were R2 > 0.999, while the relative standard deviation (%RSD) for precision was within 5%. All targeted trace metals have shown mean recoveries between 88.0%-114.9%. The obtained LOD and LOQ values for this analytical protocol indicated the ability to detect and quantify of As, Cd, Pb, and Hg at trace levels. The overall validation confirms the described analytical method was appropriate for routine analyses of As, Cd, Pb, and Hg in fish lipids.

Development of Analytical Method for Detection of Fungicide Validamycin A Residues in Agricultural Products Using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 살균제 Validamycin A의 시험법 개발)

  • Park, Ji-Su;Do, Jung-Ah;Lee, Han Sol;Park, Shin-min;Cho, Sung Min;Shin, Hye-Sun;Jang, Dong Eun;Cho, Myong-Shik;Jung, Yong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.1
    • /
    • pp.22-29
    • /
    • 2019
  • Validamycin A is an aminoglycoside fungicide produced by Streptomyces hygroscopicus that inhibits trehalase. The purpose of this study was to develop a method for detecting validamycin A in agricultural samples to establish MRL values for use in Korea. The validamycin A residues in samples were extracted using methanol/water (50/50, v/v) and purified with a hydrophilic-lipophilic balance (HLB) cartridges. The analyte was quantified and confirmed by liquid chromatograph-tandem mass spectrometer (LC-MS/MS) in positive ion mode using multiple reaction monitoring (MRM). Matrix-matched calibration curves were linear over the calibration ranges (0.005~0.5 ng) into a blank extract with $R^2$ > 0.99. The limits of detection and quantification were 0.005 and 0.01 mg/kg, respectively. For validation validamycin A, recovery studies were carried out three different concentration levels (LOQ, $LOQ{\times}10$, $LOQ{\times}50$, n = 5) with five replicates at each level. The average recovery range was from 72.5~118.3%, with relative standard deviation (RSD) less than 10.3%. All values were consistent with the criteria ranges requested in the Codex guidelines (CAC/GL 40-1993, 2003) and the NIFDS (National Institute of Food and Drug Safety) guideline (2016). Therefore, the proposed analytical method is accurate, effective and sensitive for validamycin A determination in agricultural commodities.

Use of High Molecular Alkylamines in the Simultaneous Determination of Copper and Cobalt by Spectrophotometry (구리와 코발트의 분광광도법에 의한 정량에 있어서 고분자량 알킬아민의 이용)

  • Chon Han Kim;Chan Ho Jee;Ki Tae Sung;Chang Ung Joung
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.208-214
    • /
    • 1989
  • A method for the simultaneous determination of copper and cobalt by spectrophotometry has been described. The procedure involves the co-extraction of Cu(Ⅱ) and Co(Ⅱ) from 0.3M HCl into methyl isobutyl ketone as the ion-pairs formed between their thiocyanate complexes and high molecular alkylamines such as Amberlite LA1, Alamine 336, and Aliquat 336. The extract shows the color development to have the maximum absorbances at two different wavelengths i.e., 480 nm for copper and 625 nm for cobalt. Since the spectra of the ion-pairs overlap each other, two simultaneous equations are used to obtain the concentrations from absorbances. Even small amount of Fe(Ⅲ) and Ni(Ⅱ) interferes with the determination of copper. The results of the analysis of samples are in good agreement with the results determined by separate methods within RSD 5.9%.

  • PDF

Europium-Enoxacin Complex as Fluorescence Probe for the Determination of Folic Acid in Pharmaceutical and Biological Samples

  • Alam, Al-Mahmnur;Kamruzzaman, Mohammad;Lee, Sang-Hak;Kim, Young-Ho;Min, Kyung
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.9
    • /
    • pp.3055-3060
    • /
    • 2012
  • A simple, rapid and sensitive spectrofluorometric method was developed for the determination of folic acid (FA), based on its quenching effect on the fluorescence intensity of enoxacin (ENX)-europium ($Eu^{3+}$) complex as a fluorescent probe. Fluorometric interaction between ENX-$Eu^{3+}$ complex and FA was studied using UV-visible and fluorescence spectroscopy. The quenched fluorescence intensity at an emission wavelength of 614 nm was proportional to the concentration of FA. Optimum conditions for the determination of FA were investigated. Under optimal conditions, the reduced fluorescence intensity at 614 nm was responded linearly with the concentration of FA. The linearity was maintained in the range of $1.25{\times}10^{-9}$ to $1.50{\times}10^{-7}$ M (R = 0.9986) with the limit of detection ($3S_b/m$) (where $S_b$ is the standard deviation of blank and m is the slop of linear calibration curve) of $6.94{\times}10^{-10}$ M. The relative standard deviation (RSD) for 9 repeated measurements of $1.0{\times}10^{-9}$ M FA was 1.42%. This method was simple, cost effective, and relatively free of interference from coexisting substances. Successful determinations of FA in pharmaceutical formulation and biological samples with the developed method were demonstrated.

Development and Validation of Primary Method for the Determination of Glucose in Human Serum by Isotope Dilution Liquid Chromatography Tandem Mass Spectrometry and Comparison with Field Methods

  • Lee, Hwa Shim;Lee, Jong Man;Park, Sang Ryoul;Lee, Je Hoon;Kim, Yong Goo
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1698-1702
    • /
    • 2013
  • Glucose is a common medical analyte measuring in human serum or blood samples. The development of a primary method is necessary for the establishment of traceability in measurements. We have developed an isotope dilution liquid chromatography tandem mass spectrometry as a primary method for the measurement of glucose in human serum. Glucose and glucose-$^{13}C_6$ in sample were ionized in ESI negative mode and monitored at mass transfers of m/z 179/89 and 185/92 in MRM, respectively. Glucose was separated on $NH_2P$-50 2D column, and the mobile phase was 20 mM $NH_4OAc$ in 30% acetonitrile/70% water. Verification of this method was performed by the comparison with NIST SRMs. Our results agreed well with the SRM values. We have developed two levels of glucose serum certified reference material using this method and distributed them to the clinical laboratories in Korea as samples for proficiency testings. The expended uncertainty was about 1.2% on 95% confidence level. In proficiency testings, the results obtained from the clinical laboratories showed about 3.6% and 3.9% RSD to the certified values. Primary method can provide the traceability to the field laboratories through proficiency testings or certified reference materials.

Analysis of Haloacetic Acids in Drinking Water by Direct Derivatization and Headspace-SPME Technique with GC-MS (Handspace Solid Phase Microextraction 방법에 의한 HAAs 분석에 관한 연구)

  • Cho, Deok-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.638-648
    • /
    • 2004
  • In many drinking water treatment plants, chlorination process is one of the main techniques used for the disinfection of water. This disinfecting treatment leads to the formation of haloacetic acid (HAAs). In this study, headspace solid-phase microextraction (HS-SPME) was studied as a possible alternative to liquid-liquid extraction for the analysis of HAAs in drinking water. The method involves direct derivatization of the acids to their methyl esters without methyl tert-butyl ether (MTBE) extraction, followed by HS-SPME with a $2cm-50/30{\mu}m$ divinylbenzene/carboxen/polydimethylsiloxane fiber. The effects of experimental parameters such as selection of SPME fiber, the volume of sulphuric acid and methanol, derivatization temperature and time, the addition of salts, extraction temperature and time, and desorption time on the analysis were investigated. Analytical parameters such as linearity, repeatability and limit of detection were also evaluated. The $2cm-50/30{\mu}m$-divinylbenzene/carboxen/polydimethylsiloxane fiber, sulphuric acid of 1ml, methanol of 3ml, derivatization temperature of $50^{\circ}C$ derivatization time of 2hrs, sodium chloride salt of 10g, extraction time of 30 minutes, extraction temperature of $20^{\circ}C$ and desorption time of 1 minute at $260^{\circ}C$ were selected as the optimal experimental conditions for the analysis of HAAs. The linearities ($r^2$), relative standard deviations (%RSD) and limits of detection (LOD) for HAAs were 0.9978~0.9991, 1.1~9.8% and $0.05{\sim}0.2{\mu}g/l$, respectively.

Quantitative determination of 3-chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone (MX) in chlorinated drinking water using sample enrichment followed by liquid-liquid extraction and GC-MS (시료 농축 후 액-액-추출과 GC-MS를 이용한 염소 소독 음용수중 3-chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone(MX)의정량 분석)

  • Kim, Hekap;Song, Byeong yeol
    • Analytical Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.29-34
    • /
    • 2016
  • This study explores the means by which MX can be effectively extracted from chlorinated water 3-Chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone (MX), a potent mutagen commonly found in chlorinated drinking water at concentrations of up to a few hundred ng/L, was quantitatively determined using sample enrichment followed by liquid-liquid extraction (LLE), derivatization to methylated form, and analysis with GC-MS. A 4-L water sample was enriched to a concentration of 0.4 L using a vacuum rotary evaporator at 30 ℃. MX in the water was extracted using ethyl acetate (100 mL × 2) as a solvent and MX in the extract was methylated with 10 % H2SO4 in methanol. MX was recovered at a rate of 73.8 %, which was higher than that (38.1 %) for the resin adsorption method. The limit of quantification and repeatability (as relative standard deviation) were estimated to be 10 ng/L and 2.2 %, respectively. This result suggested that LLE can be used for the determination of MX in chlorinated water as an alternative to more time-consuming resin adsorption method.