• Title/Summary/Keyword: RS-422 Communication

Search Result 39, Processing Time 0.024 seconds

Design and Evaluation of a Control Stick for Weapon Systems Using RS-422 Communication and an Embedded Processor (RS-422 통신과 임베디드 프로세서를 이용한 무장 조종간의 설계 및 평가)

  • Young-Jun Lee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.19 no.4
    • /
    • pp.647-654
    • /
    • 2024
  • In military weapon systems, control sticks for weapon operation are essential. This paper presents the design and performance evaluation of a control stick for weapon systems using RS-422 communication and an embedded processor. This control stick is ergonomically designed, considering the hand dimensions of Korean pilots and mission convenience. The circuitry and software based on RS-422 communication were designed using an embedded processor. A prototype of the control stick was manufactured and subjected to a series of tests, including basic performance tests and various environmental tests such as altitude, high temperature, low temperature, temperature shock, humidity, rain, vibration shock, and acceleration, all of which met the required standards.

The implementation of home network using the RS422 Multi-drop mode serial communication (RS422 Multi-drop mode 시리얼 통신을 이용한 홈 네트워크 구현)

  • Byun Pil-sang;Kim Myeung-hwan;Kim Deok-jin;Park Se-hyun;Park Yeoun-sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.7
    • /
    • pp.1445-1451
    • /
    • 2005
  • Home-Network is an integrated network of the PC and all electric home appliances in the home so that they can communicate with each other. In the 21th century, here are various technology for Home Network environment such as HomePNA, IEEE 1394, Ethernet Lan and Bluetooth. For Home Network construction, generally, the standard series interface 'RS232' is used to make communication possible between electric home appliances. However Home network using RS232 has a problem. That is, All machines have to be connected to each other with RS232 using Point-to-Point mode. In this case, the system becomes complicated because we have to use circuits as much as there are machines and increased expenses. To improve this problem, In this thesis, designed home network using RS422 Multi-drop mode serial communication and controled it with embedded linux system. And connected RS422 with motors and sensors using PIC to make the home network virtual environment.

The implementation of home network using the RS422 Multi-drop mode serial communication (RS422 Multi-drop mode 시리얼 통신을 이용한 홈 네트워크 구현)

  • Byun, Pil-Sang;Kim, Myeung-Hwan;Kim, Deok-Jin;Park, Se-Hyun;Park, Yeoun-Sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.512-516
    • /
    • 2005
  • Home-Network is an integrated network of the PC and all electric home appliances in the home so that they can communicate with each other. In the 21th century, here are various technology for home Network environment such as HomePNA, IEEE1394, Ethernet Lan and Bluetooth. For Home Network construction, generally, the standard series interface 'RS232' is used to make communication possible between electric home appliances. However Home network using RS232 has a problem. That is, All machines have to be connected to each other with RS232 using Point-to-Point mode. In this case, the system becomes complicated because we have to use circuits as much as there are machines and increased expenses. To improve this problem, In this thesis, designed home network using RS422 Multi-drop mode serial communication and controled it with embedded linux system. And connected RS422 with motors and sensors using PIC to make the home network virtual environment.

  • PDF

Research of Real Time Monitoring System Development Using TCP/IP & RS-422 Communication (TCP/IP & RS-422 통신을 이용한 실시간 모니터링 시스템개발에 관한 연구)

  • 이주열;문경록;김재문
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.165-168
    • /
    • 2002
  • This paper has been studied about the real time monitoring system development using TCP/IP ethernet and RS-422 serial communication link in general communication methods that rocket fire control agents could be monitoring about real time Rocket fire event procedures and be managing total rocket fire courses. Also, this paper has been studied the HMI(Human Machine Interface) control program and algorithm that guarantee confidential control for the Fire Display System.

  • PDF

Multiple UART Communications Using CAN Bus (CAN 버스를 이용한 다중 UART 통신)

  • Kang, Tae-Wook;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.24 no.4
    • /
    • pp.1184-1187
    • /
    • 2020
  • This paper proposes an in-vehicle network controller fully exploiting the advantages of UART (Universal Asynchronous Receiver/Transmitter) and CAN (Controller Area Network). UART is used in 1-to-1 communication and it exploits parity bit for data integrity check. The proposed in-vehicle network controller converts UART into CAN, which enables multiple communications along with 1-to-1 communication. Also, the proposed in-vehicle network controller exploits CRC (cyclic redundancy check) for data integrity check, which increases communication reliability. CAN is controlled by microprocessor, but the proposed in-vehicle network controller can be controlled by any devices compliant with RS-232, RS-422, and RS-485.

The Efficient Method for Video Data Streaming via NMEA-0183 (NMEA-0183 기반 영상데이터의 효율적인 스트리밍 기법)

  • Kim, Byoung-Kug
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.10
    • /
    • pp.1300-1305
    • /
    • 2020
  • Due to the simplicity of communication structure using RS-232 and RS-422, the majority ships have still adapted on these communication interfaces and have constructed their own communication network in the ship. NMEA-0183 is the one of standards for BNWAS(Bridge Navigational Watch Alarm System) and currently being used in many countries. BNWAS utilises diverse sensor devices, GPS, AIS and so on for monitoring the status of ships and their deployments and environmental information(temperature, humidity, wind speed/direction, water temperature/current etc…). This paper proposes the use of any image sensors in NMEA-0183 environment and verifies possibility with certain video qualities through the experiment results. Furthermore the paper gathers videos and monitors the change of their qualities depending on the number of NMEA messages on RS-232 communication link. Finally we make conclusion that our proposal is sufficiently appropriate for ship monitoring system in the NMEA-0183.

Implementation of Ship Area Network NMEA protocol Bridge Based on Power Line Communication (전력선통신 기반의 선박용 M모A 프로토콜 브릿지 구현)

  • Kim, Gwan-Hyung;Kang, Sung-In;Jeon, Jae-Hwan;Kwon, Oh-Hyun;Oh, Am-Suk;Cho, Hyun-Cheol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.11
    • /
    • pp.2419-2422
    • /
    • 2010
  • The current marine internal communication systems are usually composed of NMEA0183, NMEA2000, and MiTS protocols which are located on the physical layer based on RS-422, RS-485, CAN, and EtherNet. However, general vessel communication method have a weak point that must establish the extra private line. But, the power line communication has advantage over general vessel communication method as it uses AC220V/DC24V without changing line. Therefore, we will propose a new bridge based on the DC-PLC(power Line communication) technique which support the NMEA0183 protocol inside vessel network systems.

Implementation of Ship Area Network NMEA protocol Bridge Based on Power Line Communication (전력선통신 기반의 선박용 NMEA 프로토콜 브릿지 구현)

  • Kim, Gwan-Hyung;Kang, Sung-In;Jeon, Jae-Hwan;Kwon, Oh-Hyun;Oh, Am-Suk;Cho, Hyun-Cheol
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.577-578
    • /
    • 2010
  • The current marine communication networks are usually composed of NMEA0183, NMEA2000, and MiTS protocols which are located on the physical layer based on RS-422, RS-485, CAN, and EtherNet. This paper proposes a new bridge based on the DC power line communication technique supported from the NMEA0183 to design inside marine systems.

  • PDF

Development of UFC/DC Data Communication method for XKO-1 using RS-422 Bus (RS422 버스를 이용한 저속통제기 UFC/DC 데이터 통신 기법 개발)

  • 양승열;김영택
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.123-131
    • /
    • 2002
  • ASC(Avionics System Computer) was developed to control weapon delivery and navigation sensors, and to perform man-machine interface with pilots for XKO-1 aircraft. The data communications between ASC and UFC(Up Front Controller), DC(Data Concentrator) were implemented by RS422 serial data bus. Also, SCIL(Standard Computer Interface Library) was designed to facilitate control and management of the computer hardware resources and is embedded in the ASC. These structures have a merit of noise immunity and a reduction of wire harness for signal lines, and enable OFP(Operational Flight Program) programmers to use the SCIL easily without knowing hardware details. Manufactured system was on installed on XKO-1, and peformed for BIT(Built In Test) and interface test with UFC and DC. The test results show that it meets the system requirements.

The Development of an Automatic Aquaculture System -1. Using a model tank- (양어장 자동화 시스템의 개발 -1. 모형 수조를 중심으로-)

  • KANG Ho-Won;LEE Seong-Ho;KIM Je-Yoon;JEONG Seok-Kwon;KIM Sang-Bong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.3
    • /
    • pp.294-300
    • /
    • 1995
  • In aquaculture industrial field, an automatic management and control system is needed to cope with the difficulties such as expensive wage, ripe age of management worker and risk according to the unexpected change of environmental conditions in the aquarium. This paper introduces an automatic aquarium monitoring and control system. The system is developed using PC single board computer. A PC can be connected to multi-single hoard computers, and the communication between PC and single board computers is based on RS-422/485 interfacing method. The physical data of pH, DO, temperature and water level etc. are real-timely treated in the single board computer though individual transducers, transfered to the main monitoring PC through RS-422/485 communication, and those data are graphically shown on the PC monitor. Furthermore, the environmental circumstance can be monitored through the image processing system, and the emergency system can be operated under the condition of environmental incident such as electric power stoppage, DO deficiency, pump shut down and low level water etc.

  • PDF