• Title/Summary/Keyword: RS-232c communication

Search Result 104, Processing Time 0.037 seconds

Implementation of a Communication Algorithm between Actuator Controller and Manufacturing System (제조 시스템과 제어기 사이의 통신알고리즘 구현에 관한 연구)

  • Jeong, Hwa-Young;Hong, Bong-Hwa;Kim, Eun-Won
    • 전자공학회논문지 IE
    • /
    • v.46 no.2
    • /
    • pp.46-52
    • /
    • 2009
  • The manufacturing system was used to communicate between controller and GUI system by RS232C. The controller is deal with processing the equipments such as cylinders, motors, sensors, and so on. The Gill system received the signal from actuator controller by direct communication ways, RS232C, and presented the data to user to analyze the all of status for manufacturing system. In this point, it is important that communication use the RS232C. The way is helpful to be able to reduce cost, have simple structure, and easily maintain the stable communication status. Otherwise, the way has some problem to loss signal or data under the high speed communication. So it needs to complement the communication process to without loss data. In this research, we made the communication algorithm and implement the process to reduce losing data when it send or receive the signal using RS232C between controller and manufacturing system.

Monitoring system design&Implementation using wireless solution (무선 통신을 사용한 모니터링 시스템의 설계 및 구현)

  • Jeon Yoon-Ho;Woo Jong-Hyun;Kim Young-Ryun;Kim Hee-Dong
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.39-42
    • /
    • 2002
  • RS-232C는 정보기기들을 연결하는 직렬통신 표준으로, 간단한 구조로 인해, 복잡한 요구 조건이 없는 상용 기기들의 제어 및 감시용으로 사용되고 있다. 최근 무선동신기술이 발전함에 따라, 저가격의 무선통신 기술을 활용하여 무선 RS-232C에 대한 요구가 늘어나고 있다. 무선 RS-232C로 기존 유선의 RS-232C를 대체함으로서, 기존 시스템의 변경없이 편리한 접속기능을 대체한 수 있을 것이다. 본 논문에서는 유선 RS-232C를 대체하는 무선 RS-232C 모듈을 채용하여, 전력제어에 사용하는 배전자동화 장치의 관리를 간편하게 하는 시스템의 구현에 대해서 다루고 있다. 배전 자동화시스템은 일종의 SCADA시스템의 일부로서, 통신 프로토콜로서 산업용 DNP3.0을 사용하고 있다. 무선 RS-232C 링크의 신뢰성을 확보하기 위하여, 무선 구간에 DNP3.0을 채택하였으며, 무선 통신방식으로는 무선 RF, 블루투스(Bluetooth), 무선랜(wireless LAN)등 3가지 방식을 채용하여, 설계, 구현내용을 기술하였다.

  • PDF

Implementation of two wire RS232C Serial Communication Interface using CSMA protocol (충돌검지 다중접속 프로토콜에 의한 2선식 RS232C 직렬통신 인터페이스 구현)

  • 한경호;최천원
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.3
    • /
    • pp.11-17
    • /
    • 2003
  • In this paper, we implemented 2-wire (data gnd) RS232C serial communication interface by applying the Collision Sensing Multiple Access(CSMA) Protocol. The transmitting and receiving wires of RS232C pert are connected together by the interface circuit forming data wire without hardware modification On two-wired common channel connection simultaneous transmission Don mere than two hosts causes data collision. The collision is detected by loop-back test of transmission data comparing with the fed back data to detect the data distortion. Various models are adopted to reduce the probability of retransmitted data collision and experiments show the performance of each cases. Due to allowing multiple hosts to be accessed through the common communication channel with minimum circuit addition the result of this paper can be easily applied for conventional RS232C instruments and machines to connect to the single data communication line.

A study of multi protocol communication on single serial interface (Serial 전송라인에서 Multi-Protocol 통신의 구현 연구)

  • Lee, Jae-Cheol;Ko, Dae-Sik
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.5
    • /
    • pp.464-469
    • /
    • 2008
  • The RS-232C (Unbalanced serial) and RS-485 (balanced serial) are standard in serial communication. RS-485 uses a differential electrical signal, as opposed to unbalanced signals referenced to ground with the RS-232. Differential transmission, which uses two lines each for transmit and receive signal results in greater noise immunity and longer distances as compared to the RS-232C. The greater noise immunity and distance are big advantages in industrial environments. In general, one protocol on one serial interface is very normal application. In this study, we implemented multi protocols on one serial RS-485 interface and examine the performance and result with hanging multi equipments.

  • PDF

Design and Implementation of the JAVA Serial Communication Program to Control the Industrial Digital Indicator (산업용 디지털 지시계 제어를 위한 자바 시리얼 통신 프로그램의 설계와 구현)

  • Kim, Tai-Suk;Kim, Jong-Soo;Lee, Jung-Hwa
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.6
    • /
    • pp.794-801
    • /
    • 2011
  • Main machinery in the factory have various digital indicator to display its operating data for the manager. It is useful to control these datum at the remote office for factory automation in order to increase machine productivity. It is easy to use Ethernet infrastructure for remote communication. But most of all machinery in domestic factories still support RS232c or RS485 serial communication way. In this case to control machinery datum on the ethernet base, it is need to change RS232C or RS485 data to ethernet base. In this paper, in order to develop a remote progress management system through the wireless Internet, we show a design method to make easy maintenance by developing the system with both the JAVA language and RxTx Package for RS232c serial communication. For the system implementation, we added the digital indicator connect with a thermo couple to a machine which provide the real time status data of temperature. To connect machines management server program, we set up a convertor to change the RS485 data to the RS232c and also another convertor to change the RS232c data to wireless ethernet.

Interface Conversion to Extend Communication Cable of Ultrasonic Sensor (초음파 센서 통신선 연장을 위한 인터페이스 변환)

  • Seo, Dae-Il;Kwon, Byung-Hyuk;Kim, Sang-Jin
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.3
    • /
    • pp.467-472
    • /
    • 2022
  • The 3D ultrasonic anemometer transmits measured data by connecting PC and RS232C interface. Depending on the observation location, it is often necessary to extend the cable connecting the PC and the sensor. When installing on the test bed of the Air Meteorological Agency, the original AWM2919 cable was required to be extended because the distance between the PC container and the equipment installation site was more than 30 m. The cable was extended through a process such as extending the AWM2919 cable, converting the interface with the PC from RS232C to RS485, and testing the RS485 communication. After the equipment was installed with an extended cable, data were remotely collected and analyzed to confirm successful cable extension.

Implementation of RS232C Serial Communication by CSMA protocol (충돌검지 다중접속(CSMA) 프로토콜에 의한 RS232C 직렬통신의 구현)

  • Kwak, Hee-Soo;Han, Kyong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2473-2475
    • /
    • 1998
  • In this paper, we implemented RS232C serial communication by the 2 wires(Data,GND), and multiple access, by the applying Collision Sensing Multiple Access(CSMA) Protocol. Multiple access is implemented by assigning a unique ID to each controller. The multiple access control operation starts by sending a command packet from a host to another host and the command packet is composed of ID bytes of source and target host computer, data bytes and the check sum, byte. In host computer, after sending command packet, the collision from loop back data. If collision is detected, it means a command packet was collided with another command packet for another host. The packet communication of the controller enables the multiple acces of the controller through the common serial data link. The application of this serial communication through CSMA protocol and the usage of two wires, have an effect on saving the wires and convenient of layout work.

  • PDF

Implementation of RS232C and TCP/IP Connection Device Using ARM Processor (ARM프로세서를 이용한 RS232C와 TCP/IP 접속장치의 구현)

  • Lee, Young-Jun;Han, Kyong-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.635-638
    • /
    • 2002
  • In this paper, the connection device of RS232C and TCP/IP implementation using ARM processor and LINUX is proposed. Data interaction flash memory the multiple serial ports are transferred to ARM processor and the data are processed and formed into data packet for transfer via internet protocol. Packet flash memory Internet is decoded to extract the serial port data. The serial ports supports RS232C asynchronous protocol communication and control program is developed in GNU-C and installed in the on-board memory for packet conversion and control. The research result can be applied to terminal server, printer server and multiple serial ports equipments.

  • PDF

Performance of Serial Communication Protocols through Conducting Threads (전도성사를 매체로 한 직렬 통신 프로토콜 성능)

  • Kim, Na-Young;Kim, Hwan;Kim, Juk-Young;Kwon, Young-Mi
    • Journal of Internet Computing and Services
    • /
    • v.12 no.5
    • /
    • pp.21-28
    • /
    • 2011
  • Recently medical and entertainment applications using conducting textile are suggested, but the data of conducting threads are not characterized, classified and verified. Only the data sheet published by manufacturing companies is available. Thus we need to verify the performances of the threading threads in communication. And we need a guideline if the existing communication protocols can be used for the conducting threads communication or the new specific communication protocols have to be developed for the communication. This paper classifies the characteristics of conducting threads made by domestic and overseas companies. Based on the criteria we classified conducting threads into three classes: class A, class B and class C. Further we carried out experiments to verify the adaptability of existing simple serial communication protocols such as RS232. Six different conducting threads are used in experiments and the length of each thread was 0.5m, 1m, 2m and 3m. The data transmission rate and error rate are collected and analyzed. RS485 is very prone to error due to static electricity from human and environment. So it may not be appropriate as long-distance communication protocol up to 12km which is possible in theory. RS232 shows stable and error-less data transmission ability even though every conducting thread didn’t show transmission capability over RS232. USB protocol shows high data rate transmission but the distance cannot be exceeded over 2m. Additionally, USB requires stable power supply. But if the power is supplied through conducting thread, its function is not.

The Implementation research of CAN linked safety sensor hardware (CAN 연계형 안전진단센서 하드웨어 설계에 관한 연구)

  • Jeong, Soon-Ho;Kim, Seoung-Kwon;Cha, Jae-Sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.5
    • /
    • pp.209-213
    • /
    • 2010
  • This paper is a study of Car safety network system using sensed data from varied sensors. This hardware will work with various sensors and communication protocols. There are many sensors. Then, I selected 3 sensors for test, which were sonic sensor for distance checking, tilt sensor for rollover and impact sensor for car accident and theft. Also, there are many interfaces for sensor. Therefore I designed hardware to support various sensor interfaces. For instance ADC(Analog to Digital converter), I2C, RS232, RS485, CAN. In this case, sonic sensor have I2C interface, tilt sensor have RS485 interface and Impact sensor have analog interface. In this research, I can gather sensing data from 3 sensors (mentioned above), and sending control signal to other processor with RS232, RS485, CAN communication. So, we can use easily this hardware for many cases of systems, which need sensors.