• Title/Summary/Keyword: RQR 선질

Search Result 3, Processing Time 0.02 seconds

Evaluation of Energy Dependency for Air Kerma Area Product by RQR Beam Quality and Indirect Calibration (RQR 선질에 따른 공기커마 면적선량계의 에너지 의존성 평가와 간접 교정)

  • Kim, Jung-Su;Kim, Sung-Hwan;Kim, Mi-Jeong;Lee, Seung-Youl;Lee, Tae-Hee;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.769-776
    • /
    • 2018
  • According IEC 60601-1 ed3.1 and IEC 60601-2-45 regulation, diagnostic X-ray equipment should be display to measured and calculated air kerma area product. On the clinical X ray equipment, air kerma area product dosimeter would like to have an evidence for dosimeter accuracy and energy dependency. This study was performed to indirect calibration and energy dependency test for attached type air kerma area product (KAP) dosimeter by RQR standards beam quality. On the RQR5 beam quality, attached KAP dosimeter error showed -7.5%, respectably. On the RQR9 beam quality, attached KAP dosimeter error showed -10.4%, respectably. All RQR beam quality, average absolute error was $8.30%{\pm}2.85%$, respectably. On this study, attached KAP dosimeter was satisfied to IEC 60580 and AAPM TG 190. This calibration method of KAP dosimeter will help to performance maintain for clinical KAP dosimeter.

Dose and Image Quality Analysis According to The Type of Composite Additional Filter (복합 부가필터 종류에 따른 선량 및 화질 분석)

  • Myoung, Noh-Beom;Im, So-Yeon;Yoo, Se-Jong;Kim, Seong-Ho;Jeon, Min-Cheol
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.10
    • /
    • pp.147-154
    • /
    • 2020
  • In this study, four types of composite added filtration (aluminum, nickel, copper, and zinc) were combined for each thickness to evaluate dose reduction and optimal images due to X-ray attenuation. To evaluate dose and image quality. X-ray generators, Dose Area Product(DAP) and ICY programs with RQR9 standard quality were used. In the image quality evaluation element (PSNR, RMSE, SSIM), only images with PSNR value of 30 dB or more were analyzed. As a result, the best combination in dose evaluation was 3 mmAl + 0.6 mmNi (0.16µGy㎡), and the best filter in image quality evaluation was 0.9 mmAl (PSNR 34.24dB, RMSE 79.52, SSIM 0.24). In this study, the dose aspect and the image quality aspect are mentioned, So it is considered that further studies on patient's exposure dose and optimal image will be needed in the future.

Analysis of the minimum exposure position according to the additional filtration plate (부가여과판에 따른 최소한의 피폭 위치에 대한 분석)

  • Tae-Ri, Kim;Min-Ji, Kang;Sang-Hee, La;Yun-Jeong, Shin;Tae-Gyeom, Hong;Min-Cheol, Jeon
    • Journal of Advanced Technology Convergence
    • /
    • v.1 no.2
    • /
    • pp.11-17
    • /
    • 2022
  • The purpose is to find out where medical workers can receive the minimum radiation does in clinical. In order to sett RQR standard quality of radiation, put a Al 1.5mm filter(row and column: 10 cm × 10 cm) on X-ray tube. Al 0.9 mm, Cu 0.3 mm, Ni 0.3 mm used as a filter. The Acrylic phantom were set to 13.1 cm, 18.5 cm, 21.1 cm. by the object thickness was different. As a results, when we use Al 0.9 mm, 1853 nSv was the highest numeral. It is a point of anode low 50 cm, when we use 13.1 cm Acrylic phantom. When we use Cu 0.3 mm, 173 nSv was the lowest numeral. It is a point of anode low 150 cm, when we use 13.1 cm Acrylic Phantom. In this study, it was confirmed that the spatial scattering dose decreased as the distance from the X-ray tube increased. It is considered that more studies on the exposure of scattered doses are needed in the future.