• Title/Summary/Keyword: ROOFTOP

Search Result 283, Processing Time 0.024 seconds

The Experimental Study of Radiant Cooling Test System under Different Covers (복사냉각 시스템에서 커버의 영향)

  • Byun, Ki-Hong;Smith, Theodore F.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.11
    • /
    • pp.797-802
    • /
    • 2007
  • The effects of window cover on the performance of the plate type radiant cooling test system are studied. The cover materials tested are 2mm, 1mm, 0.7mm glass, Cokin 007 filter, and PVC film. The measurements are performed during the September nights of 2005 at the rooftop of the building in Seoul. The equivalent height of the building is about a building with twelve floors. The radiant cooling performance of the black painted and aluminum film coated plate are compared under no cover condition. Also the results are compared when the system has cover over the plate. In general, the covers reduce the radiant cooling temperature differences during the nighttime. Among these covers, the PVC film cover shows the best performance. In some cases, the plate with PVC film cover shows lower temperatures than the system without cover.

A Quick MPPT Strategy of Rooftop Photovoltaic Generation System for the Electric Vehicle (전기자동차를 위한 루프형 태양광 발전 시스템의 속응 최대 전력점 추종기법)

  • Kang, Kyoungpil;Cho, Younghoon;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.325-326
    • /
    • 2014
  • This paper is research about the Maximum Power Point Tracking following algorism of solar power system attached small electric car. In this paper, we investigate P&O MPPT and Incremental Conduction MPPT among existing MPPT following algorism. And by changing them, the better algorism is proposed being able to follow Maximum Power Point rapidly as amount of solar radiation changes applied to the Solar Energy Generation System.

  • PDF

Nocturnal Radiant Cooling during the Winter by the Plate Viewing the Sky (겨울 야간 하늘에 노출된 평판에 의한 복사냉각 실험)

  • Byun, Ki-Hong
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.5
    • /
    • pp.49-55
    • /
    • 2008
  • The radiant cooling(RC) effects are studied during the winter night. The plate was viewing the nighttime sky. The data were collected at the rooftop of the Engineering building at the Dongguk University in Seoul, Korea. As observed during the summer night, the plate temperature was lower than ambient temperature under the RC favorable conditions. The parameters under study are the wind velocity, cloud index, and visibility for given system size and surface condition. The results follow the same tendency with these parameters as observed from the previous study for the summer night. As long as the wind velocity is less than around 2 m/s, the radiant cooling was observed with the system under study. In some cases, the radiant cooling temperature differences (RCTD) are higher than those for the summer night. The larger the RCTD as the wind velocity decreases and as the sky becomes clear.

Nocturnal Radiant Cooling Experiment by a Plate Viewing the Sky (야간 하늘에 노출된 평판의 복사냉각 실험)

  • Byun Ki-Hong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.6
    • /
    • pp.605-610
    • /
    • 2005
  • The purpose of this experiment is to study the radiant cooling effects by a plate directly viewing the nighttime sky. The measurements are performed on a rooftop of the Engineering building at the Dongguk University in Seoul during the month of August in 2004. The radiant cooling effects are compared using three different types of plate sufaces, namely, galvanized iron, black painted, and aluminum film coated galvanized iron plate. Among these plates, the black Painted surface showed the lowest temperature that is lower than the ambient temperature. The maximum radiant cooling temperature difference, which is ambient temperature minus plate temperature, observed is about 5 K.

RF Receiver design for Satellite Digital Audio Reception (Antenna)

  • Kim, Jang-Wook;Jeon, Joo-Seong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.7
    • /
    • pp.71-78
    • /
    • 2019
  • This paper describes a design for a RF receiver to receive satellite digital audio service. The RF receiver designed in this study is a planar structure that is easy to install on the rooftop of a car and is compact in size. In addition, it can be applied to certain commercial models because it has low noise and high gain characteristics. The impedance bandwidth of antenna is 17.8%(415MHz), and the axial ratio is below 3dB as good properties for the bandwidth of 40MHz which is a satellite digital audio service band. Also, it had a broad radiation beamwidth of $95.41^{\circ}$ in H-plane and $117.45^{\circ}$ in E-plane. From the results of the field test of satellite digital audio service reception for the RF receiver, it demonstrated good C/N rate(10.2dB).

Analysis of fires case through on-field survey of residential and commercial building in Ulsan (울산 주상복합건물 현장조사를 통한 화재사례 분석)

  • Cho, Hwi-Je;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.84-85
    • /
    • 2021
  • The fire that broke out in a residential and commercial complex in Ulsan in October 2020 was large, but no deaths occurred. For this reason, there was a difference from the previous cases, so it was analyzed through field survey. The fire was expanded to the entire building by aluminum composite panels constructed by external heat method and SMC panels in evacuation safety zones, and fire was expanded to nearby mart due to wind on the day of the fire, and there were many evacuation spaces such as 15th, 28th, and rooftop heliports.

  • PDF

Feasibility of Green Network in a Highly-dense Urbanized Area by Introducing Urban Gardens (도시정원 도입을 위한 고밀 시가화지역 내 녹지 네트워크 구축 가능성 평가)

  • Choi, Heejoon;Lee, Junga;Sohn, Heejung;Cho, Donggil;Song, Youngkeun
    • Korean Journal of Environment and Ecology
    • /
    • v.31 no.2
    • /
    • pp.252-265
    • /
    • 2017
  • This study aims to analyze the landscape ecological characteristics of green spaces within built up area of high density and evaluate the potential applicability of green patches, thereby introducing urban garden for generating green networks in residence areas. To this end, Yeoksam-Dong was selected as the site area since it is classified as both green initiative zone and alienated area of park service in Seoul. First, the current condition of green spaces in Yeoksam-Dong was identified by five categories: Street trees, private garden, public pocket garden, rooftop garden, and park. Then, the landscape index analysis through FRAGSTATS and connectivity assessment via multi-buffer zone analysis were carried out for analyzing the green networks and evaluating the potential value of green space. The results showed that the degree to which green areas in the site were distributed is arranged in the order of street tree, private garden, public pocket garden, park, and rooftop garden. In case of the street trees whose total core area (TCA, $1,618m^2$) is as high as the park's ($1,128m^2$). Private garden has potential for green network in built up area of high density by gardening since the shape of the patches are irregular (ED = 78.1m/ha) and the average distance among the patches is close (ENN=33.9m). Public pocket garden has also potential for gardening according to the result that it was found to be distributed evenly (LPI=5.7%, SHEI=0.9) with exposing external disturbance ($TCA=66m^2$). For the green network, 84% of all the study site is covered by small green network in 50m butter range of connected green area. The effect of green network was expected through gardening in public pocket garden (27%) and street tree (26%). Accordingly, it is encouraged to actively utilize street tree, private gardens, and rooftop gardens and to establish the urban gardens like local-based community gardens in public pocket garden where a variety of activities can be carried out near residential areas. By doing so, green networks can effectively be established in built up area with high density. The results of this study can contribute positively to fostering the creation of various types of urban gardens.

Planting Methods and Selecting the Landscape Woody Plants for the Expanding Urban Greenary Area - Focused on the Rooftops and Artificial Ground of Underground Parking Lots - (도시녹지면적 확보를 위한 조경수목선정 및 식재지 조성방안 연구 - 건축물 옥상, 지하주차장 상부를 중심으로 -)

  • 황경희;이경재
    • Korean Journal of Environment and Ecology
    • /
    • v.11 no.1
    • /
    • pp.46-60
    • /
    • 1997
  • The purposes of this research are to select the appropriate kinds of landscape woody plants for afforestation artificial ground and to find out the way of developing planting-tree area of artificial ground through test planting and case study. The summary of the research is as follows; As a result of observing the state of trees' growth, trees on artificial grounds grow as well as, or even better than those on natural grounds. The kinds of trees which represent better growth states on artificial soil of rooftop test area are Thuja occidentalis, Prunus armericana var. ausu, Acer palmatum, Viburnum sargentii for. sterile, Buxus microphylla var. koreana, etc. In addition, soils than on natural soils. As a result of investigating the tree's growth state according to soil beds of artificial soils, shrubs don't represent distinct differences. They show that shrubs can be planted on 30cm soil bed. The rest of trees no differences according to the variation of soil beds, and they are in normal condition or have slight damage. This means that though arbor planting area of artificial ground is made 45~60cm, it is possible for trees to grow on it. In consequence of analyzing the cases on areas of landscaping artificial grounds, as the appropriate kinds of trees for afforestation artificial ground, Diospyros kaki, Hibiscus syriacus, Syringa dilatata, Magnolia kobus, Acer ginnala and cornus alba are selected in Capital region, and Nandina domestica, Taxus cuspidata, Ilex crenata, Viburnum awabuki, Aucuba japonica and Euonymus japonica are selected in southern region. In addition, Juniperus chinensis, Zelkova serrata, Juniperus chinensis var. kaizuka, etc. are selected regardless of regional character. In accordance with the state of soil it shows great difference, namely, fertilization once or more a year and irrigation for drought is advantageous to tree's growth. This research represents that it is necessary that standards related to landscaping artificial grounds are subdivided. In addition to it, the plan for revising related to regulation is drawn up.

  • PDF

Assessment of Roof-rainwater Utilization System and Drought Resistance of Ground Cover Plants (지피식물을 이용한 우수저장형 옥상녹화 시스템 및 식물 내건성 평가)

  • Kang, Tai-Ho;Zhao, Hong-Xia
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.5
    • /
    • pp.1-8
    • /
    • 2013
  • In order to evaluate 2 extensive green roof systems(Sedum Box Roof System and Roof-rainwater Utilization System) for urban greening and select ground-cover plants, which can adapt well to the drought tolerance in an extensive green roof system on 12 species. This study was carried out in order to suggest an experimental base in assessment of the Green Roof-rainwater Utilization System and selecting the drought resistance of plants. Adopting the natural drought method, this paper studies the drought resistance of 12 kinds of ground cover plants. The drought-resistance of ground cover plants subjected to dry processing time were evaluated using relative water content on leaves, relative electric conductivity and chlorophyll content in 12 kinds of plants, and the relation between soil water content under drought stress. Drought resistance of the plants were subject to rooftop drought resistance treatments. The result showed that with the increase of stress time, the relative water content and chlorophyll content on leaves were in a downward trend while the relative electric conductivity was in an upward trend. Among the 12 species of ground cover plants, excluding Pulsatilla koreana, Ainsliaea acerifolia was selected for rooftop plants because they showed resistance to drought strongly and took adaptive ability. These results showed that drought tolerance of plants in Roof-rainwater Utilization System were stronger than the Sedum Box Roof System. Therefore, the Roof-rainwater Utilization System is good for plants. It helps them adapt well to the drought tolerance in rooftops and can be used for urban greening.

Exposure Assessment of Solvents and Toluene Diisocyanates among Polyurethane Waterproofing Workers in the Construction industry (건설현장 우레탄 방수작업자의 휘발성 유기화합물 및 톨루엔 디이소시아네이트 노출평가)

  • Park, Hyunhee;Hwang, Eunsong;Ro, Jiwon;Jang, Kwangmyung;Park, Seunghyun;Yoon, Chungsik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.2
    • /
    • pp.134-152
    • /
    • 2020
  • Objectives: The objective of this study was to evaluate volatile organic compounds (VOCs) and toluene diisocyanates (TDIs) exposure among polyurethane waterproofing workers in the construction industry. Methods: Task-based personal air samplings were carried out at seven construction sites using organic vapor monitor for VOCs (n=88) and glass fiber filters coated with 1-(2-pyridyl)piperazine(1-2PP) for TDIs (n=81). The concentration of VOCs and TDIs were shown for four different work types(mixing paint, primer roller painting, urethane resin spread painting, painter assistant) at five different worksites (rooftop, ground parking lot, piloti, bathroom, and swimming pool). The two TDI sampling methods (filter vs impinger) were evaluated in parallel to compare the concentrations. Results: The geometric mean(GM) concentration of VOCs Exposure Index (EI) was highest for primer roller painting (1.4), followed in order by, urethane resin spread painting (0.85), mixing paint (0.53), and painter assistant (0.35) by work types. The GM of VOCs EI was highest for bathroom (1.4) followed in order by, swimming pool (0.85), piloti (0.89), ground parking lot (0.82) and rooftop (0.57) by worksites. The GM of 2,4-/2,6-TDI concentration was 0.052 ppb and 0.432 ppb each. There was no statistical difference in TDIs concentrations among worksites. The concentration of 2,6-TDI was ten times higher than that of 2,4-TDI. The concentration of 2,6-TDI by impinger method was 5.7 times higher than that by filter method. Conclusions: In this study, we found 38.6% of the VOCs samples exceeded the occupational exposure limits and 19.8% of the 2,6-TDI samples exceeded 1 ppb among polyurethane waterproofing workers. The most important determinants that increase the concentration of VOCs and TDIs was indoor environment and primer painting work.