• Title/Summary/Keyword: ROM reduction

Search Result 89, Processing Time 0.029 seconds

Comparison of the Effect in ROM Increase and Pain Reduction on Stretching During Ultrasound Treatment in Patients With Frozen Shoulder (동결견 환자의 초음파치료 시 신장여부에 따른 관절가동범위 회복과 통증감소 효과 비교)

  • Yang, Hoe-Song
    • Physical Therapy Korea
    • /
    • v.10 no.1
    • /
    • pp.129-137
    • /
    • 2003
  • A single subject experimental design (alternating treatment design) was used to compare the effects of only ultrasound and ultrasound combined with stretching of the joint capsule on the ROM increase and pain reduction in patients with frozen shoulder. Two subjects were included in each group. In the only ultrasound treatment sessions, ultrasound was applied at the pain point of the shoulder joint in supine position. In the ultrasound combined with stretching treatment sessions, ultrasound was applied at the pain point of the shoulder joint positioned in external rotation and abduction in sitting position. Only ultrasound treatment and ultrasound combined with stretching treatment were alternately performed on each patient. Pain and disability was measured by shoulder pain and disability index (SPADI), and range of motion (ROM) was measured by scratch test. The results of this study showed that ultrasound combined with stretching treatment were more effective than only ultrasound treatment in ROM increase and pain reduction. However, disability score was not significantly different.

  • PDF

Identifications and Reduction Methods of Aerodynamic Noise Sources in High Speed Rotating Optical Disk Drive (고속으로 회전하는 광디스크 드라이브의 공력 소음원 규명 및 소음저감방법)

  • Kim, Yong-Seok;Lee, Duck-Joo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.6 s.123
    • /
    • pp.477-483
    • /
    • 2007
  • Major noise source in high speed rotating optical disk drives (CD and DVD-ROM) arises due to the high-speed airflow produced from the upper and lower surfaces on the rotating disk. The present paper deals with the experimental approach how to identify the noise source based on the fundamental principles of aeroacoustics and to propose a reduction method of the noise source. The CD-ROM device is composed of disk, window tray, motors at the bottom place and electronic circuit plate also located below the window plate. The window is cut in the tray to read the disk information using the optical device located below the tray and moving linearly from the center of the disk through the end of the disk. All components are possible noise generators. Experimental studies were carried out in the anechoic room with various design modifications, such as tray geometry, window size and hole location on tray, to identify the major aerodynamic noise source and significant reductions of the aerodynamic noise were obtained.

A Low Power Charge Recycling ROM Architecture (저 전력 전하 재활용 롬 구조)

  • Yang, Byeong-Do;Kim, Lee-Seop
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.11
    • /
    • pp.821-827
    • /
    • 2001
  • A new low power charge-recycling ROM architecture is proposed. The charge-recycling ROM uses charge-recycling method in bit lines of ROM to save the power consumption. About 90% of the total power used in the ROM is consumed in bit lines. With the proposed method, power consumption in ROM bit lines can be reduced asymptotically to zero if the number of bit lines is infinite and the sense amplifiers detect infinitely small voltage difference. However, the real sense amplifiers cannot sense very small voltage difference. Therefore, reduction of power consumption is limited. The simulation results show that the charge-recycling ROM only consumes 13% ~ 78% of the conventional low power contact programming mask ROM.

  • PDF

Effects of Wearing a Microcurrent Wrist Guard on Pain Scale, Range of Motion, and Muscle Strength in Elderly Women with Carpal Tunnel Syndrome (미세전류 손목 보호대 착용이 손목터널증후군 노인 여성의 통증 척도, 관절가동범위 및 근력에 미치는 영향)

  • Hyesun Park;Jinhee Park;Jooyong Kim
    • Journal of Fashion Business
    • /
    • v.27 no.5
    • /
    • pp.1-12
    • /
    • 2023
  • The purpose of this study was to investigate impact of wearing low-level current wrist guards on pain scale, range of motion (ROM), and muscle strength in elderly women with Carpal Tunnel Syndrome (CTS). Subjects were 12 elderly women aged between 65 and 85 years who were diagnosed with CTS symptoms. Measurements included grip strength and wrist ROM. Wrist ROM was assessed through flexion and dorsiflexion. Wrist guards were worn. After two weeks, pain level was assessed using the Visual Analogue Scale (VAS). Results showed a significant reduction in VAS score in the MES group after stimulation, whereas there was no difference in the control group. However, there was no significant difference in ROM between the MES group and the control group. Grip strength increased in the MES group after two weeks (p ≤ 0.001). In conclusion, clinical trials suggest that MES wrist guards might be provided as an adjunctive treatment method for CTS patients. This study provides foundational data for the design and use of auxiliary devices such as gloves in the field of MES research for pain reduction, ROM improvement, and muscle strength enhancement resulting from CTS.

Design and Implementation of Direct Digital Frequency Synthesizer Using Reduced ROM Size Algorithm (ROM 축소 알고리즘을 이용한 직접 디지털 주파수 합성기의 설계 및 구현)

  • Kim, Jong-Hyeon;Do, Jae-Cheol;Song, Yeong-Seok;Park, Jong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.946-949
    • /
    • 2003
  • In this paper, a DDFS(Direct Digital Frequency Synthesis)chip has been designed focusing on the reduction of ROM size and implemented using FPGA. When calculating the sine value for the input phase value, we used the Taylor series expansion approximation method to reduce the number of addresses of ROM. We also used the piecewise straight line approximation method, ie, the stored value int the ROM is the difference of the sine value and the straight line approximation. Using this method, we could reduce four bits for each ROM data.

  • PDF

The Efficient Design Method Of ROM Accessed Address In Due Sequence (순차 주소 접근 ROM의 효율적인 설계 방법)

  • Kim, Yong-Eun;Kim, Kang-Jik;Cho, Seong-Ik;Chung, Jin-Gyun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.8
    • /
    • pp.18-21
    • /
    • 2009
  • In the digital system, ROM has a large power-consumption and a speed-bottleneck. According to gradual growth of system speed, ROM is demanded to have low-power consumption and high-speed operation design. The ROM adapted in FFT or FIR filter needs method of sequential accessed addressing. We proposed a reduction method for the number of storage cells in this paper. The number of storage cells which is connected with bi-line is reduced by the proposed method so that the capacitance value of bit-time is reduced. In this case, delay time, and power consumption are reduced. Design result of ROM in this paper using the proposed method could reduce up to 86.3% of storage cell '1' compare with conventional method.

Controlled active exercise after open reduction and internal fixation of hand fractures

  • Jun, Dongkeun;Bae, Jaehyun;Shin, Donghyeok;Choi, Hyungon;Kim, Jeenam;Lee, Myungchul
    • Archives of Plastic Surgery
    • /
    • v.48 no.1
    • /
    • pp.98-106
    • /
    • 2021
  • Background Hand fractures can be treated using various operative or nonoperative methods. When an operative technique utilizing fixation is performed, early postoperative mobilization has been advocated. We implemented a protocol involving controlled active exercise in the early postoperative period and analyzed the outcomes. Methods Patients who were diagnosed with proximal phalangeal or metacarpal fractures of the second to fifth digits were included (n=37). Minimally invasive open reduction and internal fixation procedures were performed. At 3 weeks postoperatively, controlled active exercise was initiated, with stress applied against the direction of axial loading. The exercise involved pain-free active traction in three positions (supination, neutral, and pronation) between 3 and 5 weeks postoperatively. Postoperative radiographs and range of motion (ROM) in the interphalangeal and metacarpophalangeal joints were analyzed. Results Significant improvements in ROM were found between 6 and 12 weeks for both proximal phalangeal and metacarpal fractures (P<0.05). At 12 weeks, 26 patients achieved a total ROM of more than 230° in the affected finger. Postoperative radiographic images demonstrated union of the affected proximal phalangeal and metacarpal bones at a 20-week postoperative follow-up. Conclusions Minimally invasive open reduction and internal fixation minimized periosteal and peritendinous dissection in hand fractures. Controlled active exercise utilizing pain-free active traction in three different positions resulted in early functional exercise with an acceptable ROM.

Immediate Effects of Active Stretching Versus Passive Mobilization of the Upper Cervical Spine on Patients with Neck Pain and ROM

  • Kim, Sang-Hak;Choi, Jin-Ho;Lee, Kwan-Woo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.11 no.4
    • /
    • pp.27-32
    • /
    • 2016
  • PURPOSE: This study compared the immediate effect of a passive mobilization of upper cervical spine (Kaltenborn's joint mobilization) and an active upper cervical stretching (Olaf's Auto-stretching) on patients with neck pain and ROM. METHODS: Twenty-three subjects were randomized selected in the passive group (Kaltenborn's joint mobilization) included twelve subjects and the active group (Olaf's Auto-stretching) included eleven subjects. VAS (Visual Analogue Scale) was measured before and after neck rotation performance. DUALER IQ PRO (JTECH Medical, U.S.A.) was used to measure the neck ROM. Mean value of double measurement was used before performance and after performance. SPSS version 18 was used to compare values independent t-test and paired t-test were used to compare pain and ROM. RESULTS: There are significant difference in the pain and the ROM in both of two group (p<.05). But there are no significant difference pain and ROM between two groups. CONCLUSION: Both of the passive mobilization of upper cervical spine and the active upper cervical stretching are effected on symptom improvement of patients with neck pain reduction and ROM increasing. Especially active upper cervical stretching is more economical, because it has similar effects with the passive mobilization, help to maintain the treatment effect of therapist by themselves and can help to save medical expenses of patients.

A Study of Acoustic Noise Analysis and Reduction Method for Driving CD-ROM (CD-ROM 구동 시 발생소음 분석 및 저감 방안에 관한 연구)

  • 이재승;차성운
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.904-907
    • /
    • 2002
  • Optical disk drive device is improved in rotating speed for faster data reading. In the case of CD-ROM, rotating speed is over 10000 rpm in the practical use. As a result of high rotating speed, unexpected effects as like increasing disk fluctuation and acoustic noise are raised by the air friction on the rotating disk and the eccentricity of rotating parts. The overall acoustic noise of running CD-ROM could be classified into two different characterized noise. The first is the structural-borne noise which is generated from vibrating solid body. By the reason, the signal of structural borne noise has very similar to the signal of surface vibrating one. It has dense noise energy at specific frequency region. The other is the air-borne noise which is generated from turbulence or vortex caused by friction between disk and air. The signal of air-borne noise has no dominant peak point at acoustic pressure-frequency domain. The noise energy is widely distributed while comparatively high and large frequency region. The structural-borne noise could be reduced by reducing vibration of structure and in addition it's target reducing frequency is narrow. However the air-borne noise reduction is effectively needed of enclosing method for the noise source located near the disk surface because it is difficult to define target frequency point. In this study, the acoustic noise at driving CD-ROM is classified by the sides of it's character and tried to reduce the overall acoustic noise.

  • PDF

The Comparison of Effect of Sports Massage, Kaltenborn-Evjenth Orthopedic Manipulative Therapy and Electrical Therapy, General Exercise Therapy in ROM Increase and Pain Reduction in Patients with Frozen Shoulder (동결견 환자의 관절가동범위 회복과 통증 감소에 있어서 스포츠 마사지 및 Kaltenborn-Evjenth정형도수치료와 전기치료 및 일반 운동치료의 효과 비교)

  • Nam, Hyoung-Chun;Woo, Kwang-Seog
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.2
    • /
    • pp.73-85
    • /
    • 2003
  • The purpose of the present study was to the investigate the effect of sports massage, kaltenborn-evjenth orthopedic manipulative therapy and electrical therapy, general exercise on the limitation of range of motion(ROM) and on the pain(VAS) in patients with frozen shoulder. Fiftheen frozen shoulder patients between 50 and 60 years of age(females) were selected and were divided equally by random distribution into A group(sports massage, kaltenborn-evjenth orthopedic manipulative therapy, N=7)and B(electrical therapy, general exercise therapy, N=7) group. The results obtained were as follows : 1) The range of motion between two groups are significantly different in the treatment times, the ROM of A group increase in after-treatment(2 week 4 week) in comparison with ROM in before-treatment, it is significant increase. And it is significant difference in B group. 2) The pain level between two groups are not significantly different in the treatment times, the pain level of A group decrease in after-treatment(2 week, 4 week) in comparison with before-treatment, it is significant decrease. And it is significant difference in B group. Although the pain level of the A group decrease in after 2 week treatment in comparison with before-treatment but it is not significant decrease. Although the pain level of the B group decrease in after 4 week treatment in comparison with after 2 week treatment, but it is not significant decrease. 3) The A group is more effective in increasing the ROM and decreasing the pain level than B group during treatment times. The results showed that both A group method and B group method are effective ROM increase and pain reduce, but A group method is superior to B group method in ROM increase and pain reduce.

  • PDF