• Title/Summary/Keyword: ROM data

Search Result 377, Processing Time 0.027 seconds

Design of a Simple PCM Encoder Architecture Based on Programmable ROM (프로그래머블 ROM 기반의 심플 PCM 엔코더 설계)

  • Kim, Geon-Hee;Jin, Mi-Hyun;Kim, Bok-Ki
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.2
    • /
    • pp.186-193
    • /
    • 2019
  • This paper presents and implements a simple programmable PCM encoder structure uisng the commutation method. In the telemetry system, information is required to assign each data to the channel in order to generate a frame format the data acpuired from the sensor. In this case, when the number of state information is large or the data type is various, there is a necessity to input a large amount of information to each channel. However, the more the number of channels and data, the more probability the error will occur. Therefore, in this paper, the channel information is created using the program. And PCM encoder was implemented to store channel information in ROM. The proposed PCM encoder architecture reduces the likelihood of errors. And it can improve the development speed. The validity of proposed structure is proved by simulation.

Investigation on the nonintrusive multi-fidelity reduced-order modeling for PWR rod bundles

  • Kang, Huilun;Tian, Zhaofei;Chen, Guangliang;Li, Lei;Chu, Tianhui
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1825-1834
    • /
    • 2022
  • Performing high-fidelity computational fluid dynamics (HF-CFD) to predict the flow and heat transfer state of the coolant in the reactor core is expensive, especially in scenarios that require extensive parameter search, such as uncertainty analysis and design optimization. This work investigated the performance of utilizing a multi-fidelity reduced-order model (MF-ROM) in PWR rod bundles simulation. Firstly, basis vectors and basis vector coefficients of high-fidelity and low-fidelity CFD results are extracted separately by the proper orthogonal decomposition (POD) approach. Secondly, a surrogate model is trained to map the relationship between the extracted coefficients from different fidelity results. In the prediction stage, the coefficients of the low-fidelity data under the new operating conditions are extracted by using the obtained POD basis vectors. Then, the trained surrogate model uses the low-fidelity coefficients to regress the high-fidelity coefficients. The predicted high-fidelity data is reconstructed from the product of extracted basis vectors and the regression coefficients. The effectiveness of the MF-ROM is evaluated on a flow and heat transfer problem in PWR fuel rod bundles. Two data-driven algorithms, the Kriging and artificial neural network (ANN), are trained as surrogate models for the MF-ROM to reconstruct the complex flow and heat transfer field downstream of the mixing vanes. The results show good agreements between the data reconstructed with the trained MF-ROM and the high-fidelity CFD simulation result, while the former only requires to taken the computational burden of low-fidelity simulation. The results also show that the performance of the ANN model is slightly better than the Kriging model when using a high number of POD basis vectors for regression. Moreover, the result presented in this paper demonstrates the suitability of the proposed MF-ROM for high-fidelity fixed value initialization to accelerate complex simulation.

Effects of a Taping Method on Pain and ROM of the Knee Joint in the Elderly (테이핑 요법이 노인의 무릎 통증과 관절가동범위에 미치는 영향)

  • Park Yeong-Sook;Kim Hyun-Jung
    • Journal of Korean Academy of Nursing
    • /
    • v.35 no.2
    • /
    • pp.372-381
    • /
    • 2005
  • Purpose: This study was to investigate the effects of a taping method on pain and ROM of the knee joint in the elderly. Method: The subjects were seniors registered in a senior welfare center in D city. An experimental group of 30 persons and acontrol group of 33 persons were chosen and according to the proper conditions and a knee pain score was marked from 1-5 on a Numerical Pain Rating Scale. For the experimental group, the taping method was conducted three times a week for four weeks (twelve times in all) but the control group did not receive taping.. The measuring instrument of knee pain was a numerical pain rating scale from 0 to 10 and the ROM score was the average value of three measured values with a goniometer. The data was analyzed with SPSS WIN 10.0 using an $x^2-test$, t-test, repeated measures ANOVA, and time contrast. Result: Knee joint pain was significantly decreased in the experimental group over that of the control group (p=.001). In addition, knee joint ROM of the experimental group was significantly improved over that of the control group (p=.001). Conclusion: It was proven that the taping method was effective for pain relief and increasing ROM of the knee joint in the elderly.

The Immediate Effects of Active Ankle ROM exercise on Passive Straight Leg Raising (족관절의 능동 관절가동범위 운동이 수동 하지직거상에 미치는 즉각적 영향)

  • Sim, Hyun-Po;Yoon, Hong-Il;Lee, Jun-Yong
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.16 no.2
    • /
    • pp.40-47
    • /
    • 2010
  • Purpose : To exam the effects of active ankle range of motion(ROM) exercise on sciatic nerve movement and provide the evidence that use it to patients with hypomobile sciatic nerve as a nerve mobilization technique. Methods : The subjects consist of 32 asymptomatic healthy adults(male; 15, female; 17) who have limited passive straight leg raising(PSLR) ranges below 70 degrees. First, examiner measures PSLR angles at three times. Then, subject was instructed perform the active ankle ROM exercise(dorsiflexion and plantarflextion) at limited angle. After each subject completed the active ankle ROM exercise, return the starting position and examiner measures the PSLR angles at three times again. Results : First, PSLR range was no significant differences between dominant and non-dominant leg(p >.05). Second, active ankle ROM exercise significantly increased PSLR range by mean of degrees(p <.05). Third, there was no learning effects among the measurement trials(p >.05). Conclusion : These data show that active ankle ROM exercise can mobilize the sciatic nerve. Therefore, it can be applied to patients with hypomobile sciatic nerve(sliding dysfunction) as a neural mobilization technique.

  • PDF

The Effects of a CD-ROM Educational Program for Sexual Violence Prevention on Sexual Knowledge of Middle School Students (성희롱.성폭력 예방교육 CD-ROM이 중학생의 성폭력예방 지식에 미치는 효과)

  • Yom, Young-Hee;Lee, Kyu-Eun
    • Women's Health Nursing
    • /
    • v.9 no.4
    • /
    • pp.499-508
    • /
    • 2003
  • Purpose: This study analyzed the effects of a CD- ROM educational program for the prevention of sexual violence in relation to the sexual knowledge of middle school students. Method: A one group, pre-test-post-test design was used. The subjects of this study were 171 middle school students in Kangwon Province, Korea. The questionnaire included 34 items relating to overall sexual knowledge, and included questions on sexual violence. The collected data were analyzed using the mean, standard deviation and paired- t tests. Result: There were significant differences in the sexual knowledge by demographic characteristics between the pre- and post- tests. Of the 34 items, 20 showed significant differences in the sexual knowledge between the pre- and post- tests. Conclus ion: The overall level of sexual knowledge of the students increased after taking the CD- ROM educational program. Further testing will be required to determine the effects of the CD- ROM using a control group and random sampling.

  • PDF

An Individual Information Management Method on a Distributed Geographic Information System

  • Yutaka-Ohsawa;Kim, Kyongwol
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1998.06b
    • /
    • pp.105-110
    • /
    • 1998
  • This paper proposes a method to manage individual information on large scale distributed geographic information systems. On such system, ordinary users usually cannot alter the contents of the server. The method proposed in this paper makes possible to alter the contents or add individual data onto such kinds of non-write-permitted data onto set. We call the method as GDSF, ‘geographic differential script file’. In this method, a client user makes a GDSF which contains the private information to be added onto the served data. Then, the client keeps the file on a local disk. After this, when the user uses the data, he applies the differential data sequence onto the down loaded data to restore the information. The GDSF is a collection of picture commands which tell pictures insertions, deletions, and modification operations. The GDSF also can contain the modification. The GDSF also can contain the modification of the attribute information of geographic entities. The method also applicable to modify data on a ROM device, for example CD-ROM or DVD-ROM. This paper describes the method and experimental results.

  • PDF

The Influence of Contract-Relax Technique of PNF and Taping treatment on Pain and Range of Motion of osteoarthritis of Knee (PNF의 수축-이완 기법과 테이핑 치료가 퇴행성 슬관절염의 통증과 관절가동범위에 미치는 영향)

  • Kim, Sang-Su;Seo, Hae-Jin
    • PNF and Movement
    • /
    • v.7 no.2
    • /
    • pp.27-35
    • /
    • 2009
  • Purpose : The purpose of this study was to compare the influence of Contract-Relax Technique of PNF(Proprioceptive Neuromuscular Facilitation) and taping treatment on the ROM(Range of Motion), pain and gait speed of osteoarthrits of knee. Methods : In this study K hall for the aged were selected. Twenty-six subjects with osteoarthrits participated in the experiment. The subjects were partitioned into two groups are 13person PNF group and 13person taping group. All subjects randomly assigned to the PNF treatment group and taping treatment group. Both group received treatment for 3times a week during 4 weeks. (PNF group received treatment for twenty times at once). Algometer and VAS(Visual Analogue Scale) were used to measure pain, the ROM was meaured using goniometer and gait speed was measured using a stopwatch (30m-test). All measurements of each subject were measured at pre-treatment and post-treatment. The data were analyzed with SPSS WIN 11.5 using t-test. Results : The PNF group had a significantly increase of knee extension ROM and significantly decrease of pain after treatment 4 weeks(P<0.05). The taping group had a significantly increase of knee extension ROM and gait speed and significantly decrease of pain after treatment 4 weeks(P<0.05). Conclusion : These data suggests that PNF is beneficial to increase knee extension ROM and to decrease pain. Taping is beneficial to increase knee extension ROM and gait speed and to decrease of pain.

  • PDF

Effects of Artificial Leg Length Discrepancies on the Dynamic Joint Angles of the Hip, Knee, and Ankle During Gait

  • Kim, Yong-Wook;Jo, Seung-Yeon;Byeon, Yeoung-In;Kwon, Ji-Ho;Im, Seok-Hee;Cheon, Su-Hyeon;Kim, Eun-Joo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.14 no.1
    • /
    • pp.53-61
    • /
    • 2019
  • PURPOSE: This study examined the dynamic range of motion (ROM) of the hip, knee, and ankle joint when wearing different shoe sole lifts, as well as the limb asymmetry of the range according to the leg length discrepancy (LLD) during normal speed walking. METHODS: The participants were 40 healthy adults. A motion analysis system was used to collect kinematic ROM data. The participants had 40 markers attached to their lower extremities and were asked to walk on a 6 m walkway, under three different shoe lift conditions (without an insole, 1 cm insole, and 2 cm insole). Visual3D professional software was used to coordinate kinematic ROM data. RESULTS: Most of the ROM variables of the short limbs were similar under each insole lift condition (p>.05). In contrast, when wearing a shoe with a 2 cm insole lift, the long limbs showed significant increases in flexion and extension of the knee joint as well as; plantarflexion, dorsiflexion, pronation, eversion, and inversion of the ankle joint (p<.05). Of the shoes with the insole lifts, significant differences in all ROM variables were observed between the left and right knees, except for the knee internal rotation (p<.05). CONCLUSION: As the insole lift was increased, more ROM differences were observed between the left and right limbs, and the asymmetry of the bilateral lower limbs increased. Therefore, appropriate interventions for LLD are needed because an artificial mild LLD of less than 2.0 cm could lead to a range of musculoskeletal problems of the lower extremities, such as knee and ankle osteoarthritis.

Effects of a Balance Taping on Pain and ROM of the Knee Joint in the Elderly with Lower Limbs Arthritis (밸런스테이핑이 하지 관절염 노인의 하지통증과 무릎관절가동범위에 미치는 효과)

  • Park, Ka-Yoon;Park, Kyung-Sook
    • Korean Journal of Adult Nursing
    • /
    • v.22 no.3
    • /
    • pp.312-321
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the effects of balance taping on pain and Range of Motion (ROM). ROM of the knee joint in the elderly with lower limbs arthritis. Methods: This study was a nonequivalent pretest-posttest design, quasi-experimental study. An experimental group of 35 elderly and a control group of 35 elderly were assigned. Subjects responses to the Visual analogue Scale (VAS) and range of motion scores as measured by a joint goniometer. Data were analyzed by, t-test and repeated measures ANOVA. Results: In the experimental treatment group, the pain score was significantly decreased from 6.46 to 2.09 after balance taping (p<.001). In addition, knee joint ROM of the experimental group was significantly increased from 114.80 to 121.92 after balance taping (p=.003, p<.001, p<.001). Conclusion: This is a very important study as it is an excellent treatment that nurses can utilize and these data support the efficacy of the method.

Modeling of Digital Servo System for Optical Pickup Tuner (광 픽업 조정기를 위한 디지털 서보 시스템의 모델링)

  • 곽한섭;백광렬
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.1
    • /
    • pp.47-53
    • /
    • 1999
  • CD-ROM(Compact Disk-Read Only Memory) is very attractive storage media because it has much storage space but is small size and portable. Optical pickup, one of the most important parts for reading data on a CD-ROM, is not produced tuned up. For the use of goods, we must tune up the optical pickup by adjusting the screw for adjustment. First, we developed analog servo system for optical pickup tuners. For eliminating some problems in analog servo system, this paper designed the modeling of digital servo system for optical pickup tuner. Though the characteristics of optical pickup are changed, the digital servo system for optical pickup tuner can easily apply to all pickup, and can reduce the measurement error among the optical pickup tuners. For the purpose of confirming the designed digital servo system, we produced data that specify the disk vibration and the disk eccentricity, and simulated servo system with MATLAB.

  • PDF