• Title/Summary/Keyword: RO Membrane

Search Result 329, Processing Time 0.026 seconds

Treatment and Reuse of Acrylic Wastewater using Membrane Separation System

  • Lee, Kwanghyun
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05a
    • /
    • pp.117-120
    • /
    • 2004
  • The separation characteristics were investigated with the variations of pressure and temperature using ultrafiltration and reverse osmosis membrane module sets composed of different membrane types and materials. TDS, T-N and COD removal efficiencies were not affected and low with the change of temperature and pressure in case of using UF modules contained in module set 1, 2, 3. TDS, T-N and COD removal efficiencies were very high in RO modules. The final water quality of acrylic wastewater was satisfied within the discharge limit value of plant wastewater. It was known that membrane module sets could be used for the reuse of wastewater.

  • PDF

Mechanism of Platelet Activation Induced by Cyclic Peptide, Ro09-0198 (Cyclic Peptide, Ro09-0198의 혈소판활성화에 대한 작용기전)

  • 정세영
    • YAKHAK HOEJI
    • /
    • v.35 no.1
    • /
    • pp.11-14
    • /
    • 1991
  • Ro09-0198, a cyclic peptide isolated from culture filtrates of Streptoverticillium griseove-rticillatum, induced platelet aggregation and serotonin release simultaneously. LDH release was not observed. Addition of peptide to rat platelet, loaded with $Ca^{2+}$ chelator quin-2, caused immediate rise in cytosolic free $Ca^{2+}$. Liposomal membrane containing phosphatidylethanolamine was damaged by peptide and released $^{45}Ca$ dose dependently.

  • PDF

Evaluation on Chemical Cleaning Efficiency of Organic-fouled SWRO Membrane in Seawater Desalination Process (해수담수화 공정에서 역삼투막의 유기 막오염에 대한 SWRO 막의 화학세정 효율 평가)

  • Park, Jun-Young;Hong, Sung-Ho;Kim, Ji-Hoon;Jeong, Woo-Won;Nam, Jong-Woo;Kim, Young-Hoon;Jeon, Min-Jung;Kim, Hyung-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.177-184
    • /
    • 2011
  • Membrane fouling is an unavoidable phenomenon in operation of seawater reverse osmosis (SWRO) and major obstacle for economic and efficient operation. When fouling occurs on the membrane surface, the permeate flux is decreased, on the contrary, the trans-membrane pressure (TMP) is increased, therefore operation and maintaining costs and potential damage of membranes are able to the pivotal risks of the process. Chemical cleaning process is essential to prevent interruptions for effective RO membrane filtration process. This study focused on proper chemical cleaning condition for polyamide RO membranes of 4 companies. Several chemical agents were applied for chemical cleaning under numbers of operating conditions. Additionally, a monitoring tool of FEEM as autopsy analysis method is adapted for the prediction of organic bio-fouling.

Separation of Zinc Ion from Metal Plating Wastewaters by Reverse Osmosis Membrane (Membrane을 이용한 도금폐수 중 아연이온의 분리에 관한 연구)

  • 장자순;이효숙;정헌생;이원권
    • Membrane Journal
    • /
    • v.4 no.2
    • /
    • pp.106-112
    • /
    • 1994
  • The ultrafiltration(UF) and reverse osmosis(RO) tests for a model metal plating wastewater prepared with zinc sulfate, showed the zinc ion rejection coefficient of over 99% and the permeate flux of $1.49 {\times} 10^{-3}cm/sec$ at pH = 8.3. The effect of cyanide on the zinc removal was investigated. When the amount of cyanide addition was same the zinc content, the zinc was removed over 99% and the cyanide was excluded about 93%. The addition of the surfactants such a LAS-Na and EDTA-Na was found to reduce the permeate flux down to $0.76 {\times} 10^{-3}cm/sec$ at the RO membrane.

  • PDF

Removal Characteristics of Organic Matters in Pretreatment and Reverse Osmosis Membrane Processes for Seawater Desalination (해수담수화 전처리 및 역삼투막여과 공정의 유기물 제거특성)

  • Kim, Dong-Kwan;Choi, June-Seok;Lee, Chang-Kyu;Kim, Jinho;Choi, Jeong-Hak;Lee, Wontae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.7
    • /
    • pp.492-497
    • /
    • 2014
  • This study investigated removal characteristics of organic matters in pretreatment and reverse osmosis (RO) membrane processes for seawater desalination. Also, the influence of the changes in characteristics of organic matters on the membrane fouling was assessed. The pretreatment processes included dual media filtration (DMF), pressurized membrane filtration (MF), and submerged membrane filtration (SMF). Turbidity, UV absorption at 254 nm, dissolved organic carbon, size exclusion chromatography (SEC), fluorescence excitation emission matrix (FEEM), and transparent exopolymer particles (TEP) in raw and processed waters were analyzed. Ions and minerals were not removed by any pretreatment process tested, but were removed over 99% through the RO membrane process. Hydrophobic organics, which can play major role in organic membrane fouling, were relatively readily removed compared with hydrophilic ones. Membrane based pretreatment such as MF and SMF exhibited better removals of organics than conventional DMF. As the levels of organics in pretreated water decreased, the silt density index (SDI) decreased. MF treated water exhibited the lowest SDI value; this is possibly due to the lowest TEP ($0.1-0.4{\mu}m$) concentrations.

Development of Remote Monitoring System for groundwater purifier apparatus for community wells (마을 공동 우물용 지하수 정수 장치의 원격 모니터링 시스템 개발)

  • Kim, Dong-Jin;park, Sang-heup;Lee, Hong-Sup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.224-231
    • /
    • 2019
  • Recently, the pollution of groundwater has become serious. In particular, the contamination of groundwater near livestock farms is becoming increasingly severe and it is difficult to drink with drinking water. In this paper, a groundwater purifier apparatus that can be installed in a community well was designed. The designed groundwater purifier apparatus enables a RO membrane filter and UV sterilization to remove pollutants, such as heavy metals, bacteria, and organic compounds. In addition, electrical conductivity, pressure, and flow sensors were added for remote monitoring. Remote monitoring of the system can determine the level of fouling and contamination of RO membrane filters through pressure and flow sensor data, and can record changes in the contamination and condition of groundwater through the electrical conductivity of the feed water. The designed groundwater purifier apparatus was installed at a farmhouse and remote monitoring. The result after 15 days of operating a groundwater purifier apparatus and analyzing the monitoring data revealed an average permeate water flow rate of 2.67L/min and an average water pressure of 7.09kgf/㎠, indicating that the RO Membrane filtered without fouling and clogging. The average electrical conductivity was 796.6 S/㎠ of the feed water and 55.6 S/㎠ of permeate water, which is similar to that of general tap water. Through this, it was confirmed that no pollutant occurred in the surroundings. Therefore, the designed groundwater purifier apparatus can confirm the replacement time of the RO membrane filter in advance through remote monitoring, and check the pollution state of the groundwater.

Comparisons of Reverse Osmosis and Pervaporation Membrane Processes I. Theoretical Interpretations

  • Rhim, Ji-Won;Lee, Kew-Ho;Huang, Y.M.
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1991.10a
    • /
    • pp.47-48
    • /
    • 1991
  • The pressure in RO leads to a concentration difference across the membrane, while the concentration difference in PVAP across the membrane is achieved by applying a vacuum to the downstream compartment. Therefore, it could be possible to compare this two processes using the solution-diffusion mechanism.

  • PDF

Evaluation of Water Quality Change by Membrane Damage to Pretreatment Process on SDI in Wastewater Reuse (하수재이용에서 전처리 막 손상에 의한 수질변화가 SDI에 미치는 영향평가)

  • Lee, Min Soo;Seo, Dongjoo;Lee, Yong-Soo;Chung, Kun Yong
    • Membrane Journal
    • /
    • v.32 no.4
    • /
    • pp.253-263
    • /
    • 2022
  • This study suggests a guideline for designing unit process of wastewater reuse in terms of a maintenance of the process based on critical parameters to draw a high quality performance of RO unit. Defining the parameters was done by applying membrane integrity test (MIT) in pretreatment process utilizing lab-scale MF. SDI is utilized for judging whether permeate is suitable to RO unit. However, result said TOC concentration matching with particle count analysis is better for judging the permeate condition. When membrane test pressure (Ptest) was measured to derive log removal value in PDT, virgin state of membrane fiber was used to measure dynamic contact angle utilizing surface tension of the membrane fiber. Actually, foulant affects to the state of membrane surface, and it decreases the Ptest value along with time elapsed. Consequently, LRVDIT is also affected by Ptest value. Thus, sensitivity of direct integrity test descends with result of Ptest value change, so Ptest value should be considered not the virgin state of the membrane but its current state. Overall, this study focuses on defining design parameters suitable to MF pretreatment for RO process in wastewater reuse by assessing its impact. Therefore, utilities can acknowledge that the membrane surface condition must be considered when users conduct the direct integrity test so that Ptest and other relative parameter used to calculate LRVDIT are adequately measured.

Pretreatment of Acrylic Wastewater and Application of UF/RO Processes (Acrylic폐수의 전처리 및 UF/RO공저의 적용)

  • 이광현
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2001.05a
    • /
    • pp.135-138
    • /
    • 2001
  • Acrylic wastewater flux was discussed using modules of ultrafiltration hollow fiber and reverse osmosis spiral wound. The optimum backflushing times of membranes were decided and the degree of fouling was discussed with operating time. Permeate flux was decreased rapidly at 12hrs. Separation processes with ultrafiltration and reverse osmosis membranes were not suitable to remove COD and TDS. The improvement of pretreatment processes was needed.

  • PDF

RO분리막 공정에서 온도와 압력이 유량에 미치는 효과

  • 박영규;오세현;오호영;장일헌;송석룡
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1994.10a
    • /
    • pp.77-79
    • /
    • 1994
  • 폐수와 하수처리에서 양질의 재생수를 얻기위하여 고분자막을 이용한 폐수재활용에서 나타나는 공정상 문제점을 고찰하였다. 본 연구에서 사용한 폐수는 처탑공장의 폐수로서 RO막을 이용한 폐수의 재이용공정개발을 목표로하고 있으며, pilot실험을 토대로 폐수의 적용성 검토가 행하여졌다. 사용된 막의 종류는 중공사막형의 막으로서 막내의 층류 흐름의 응용은 투석막, 기체분리, 중금속의 추출등 상당한 관심속에 있다. 여기서 중공사막과 같은 관(Cynlindrical)형의 막 구조에서 물질과 에너지 이동현상은 막분리공정을 이해하는 중요한 물리적고찰로서 막투과도를 높힐수 있을 뿐만 아니라 운전온도에 의해 중공사막 RO막내의 유량변화에 주요한 변수가 될 수 있다.

  • PDF