• 제목/요약/키워드: RMS current

검색결과 344건 처리시간 0.023초

Wavelet 변환을 이용한 배전 계통의 고 저항 사고 검출 알고리즘 (A High Impedance Fault Detection Algorithm Using Wavelet Transform)

  • 남순열;강용철;김성수;손진만;박종근;정성일;김광호;김일동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.975-978
    • /
    • 1997
  • This Paper presents a high impedance fault (HIF) detection algorithm of distribution systems using wavelet transform. Two HIFs on dry soil and sandy soil were simulated on various load conditions in 22.9 kV distribution systems using EMTP, and the current wavelets were decomposed by wavelet transform. The current root mean square(rms) change, the index change rate and the relative amplitude change were used as the multi-criteria for a HIF detection. The index change rate and the relative amplitude were made using the wavelet coefficients.

  • PDF

ANFIS를 이용한 송전선로의 고장판별 기법에 관한 연구 (A Study on the Technique of Fault Classification in Transmission Lines Using a Combined Adaptive Network-Based Fuzzy Inference System)

  • 여상민;김철환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권9호
    • /
    • pp.417-423
    • /
    • 2001
  • This paper proposes a technique for fault detection and classification for both LIF(Low Impedance Fault)s and HIF(High Impedance Fault)s using Adaptive Network-based Fuzzy Inference System(ANFIS). The inputs into ANFIS are current signals only based on Root-Mean-Square(RMS) values of 3-phase currents and zero sequence current. The performance of the proposed technique is tested on a typical 154 kV Korean transmission line system under various fault conditions. Test results show that the ANFIS can detect and classily faults including (LIFs and HIFs) accurately within half a cycle.

  • PDF

Structural and Electrical Properties of ZrO2 Films Coated onto PET for High-Energy-Density Capacitors

  • Park, Sangshik
    • Applied Science and Convergence Technology
    • /
    • 제23권2호
    • /
    • pp.90-96
    • /
    • 2014
  • Flexible $ZrO_2$ films as dielectric materials for high-energy-density capacitors were deposited on polyethylene terephthalate (PET) substrates by RF magnetron sputtering. The growth behavior, microstructure and electrical properties of the flexible $ZrO_2$ films were dependent on the sputtering pressure and gas ratio. Although $ZrO_2$ films were deposited at room temperature, all films showed a tetragonal crystalline structure regardless of the sputtering variables. The surface of the film became a surface with large white particles upon an increase in the $O_2/Ar$ gas ratio. The RMS roughness and crystallite size of the $ZrO_2$ films increased with an increase in the sputtering pressure. The electrical properties of the $ZrO_2$ films were affected by the microstructure and roughness. The $ZrO_2$ films exhibited a dielectric constant of 21~38 at 1 kHz and a leakage current density of $10^{-6}{\sim}10^{-5}A/cm^2$ at 300 kV/cm.

Electrical Parameter Tests of Synchronous Reluctance Motor

  • Khang, Huynh Van;Hwang, Seon-Hwan;Kim, Jang-Mok;Ahn, Jin-Woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.211-213
    • /
    • 2007
  • The electrical parameters are used to calculate gains in the current regulator as well as to determine the reference currents of speed controller in various control strategies of Synchronous Reluctance Motors (SynRMs). Many methods of measuring or estimating the electrical parameters of SynRM have been proposed by other authors. But almost papers only measure or estimate in the limited conditions without fully considering the effects of inverter, connecting wire and magnetic saturation. The parameter results are usually different from the real system parameters. The drive performance, therefore, can not be good if using inaccurate parameters. In this paper, several methods used to measure the electrical parameters are introduced. The first method is LCR meter. And then, a method determining inductances by measuring AC current and voltage from AC power supply is presented. A new method with high reliability is proposed to measure the electrical parameters of SynRM. The experiment results verify the effectiveness of the new proposed method.

  • PDF

Microprocessor를 이용한 AC Current, AC Voltage의 계측 알고리즘에 관한 연구 (On the study of measurement algorithm using Microprocessor for AC Current and AC Voltage)

  • 서용원;연준상;양오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 D
    • /
    • pp.2106-2108
    • /
    • 2003
  • 단상 또는 3상의 AC 전원의 전류나 전압 또는 전력을 계측하기 위해 Analog Signal들을 Digital Signal로 변환하여 특정 Algorithm의 연산을 수행하여 결과를 얻는 과정을 Microprocessor를 이용하여 처리하는 방법은 산업현장이나 연구개발에서 흔히 사용하는 방법이다. 본 논문에서는 Microprocessor를 이용하여 보편화된 3가지의 계측 Algorithm인 DFT, True RMS, Summation Algorithm을 사용하여 동일 System에 3상 AC의 전류 부하를 일정 범위에서 가변 하여 인가시키면서 계측 값을 사용하여 Algorithm의 계측 결과의 오차율과 연산에 소요되는 시간과 외부 잡음인 Surge, Impulse, 정전기, 방파, 고조파에 대한 System의 처리 효율을 연구 하였다.

  • PDF

유사아크부하의 직렬아크신호 분석 및 검출 알고리즘에 관한 연구 (A Study of Detection Algorithms and Analysis Series Arc of Quasi-arc Load)

  • 임종웅;주재연;강경필;방선배;최규하
    • 조명전기설비학회논문지
    • /
    • 제28권7호
    • /
    • pp.81-90
    • /
    • 2014
  • This paper proposes new arc algorithm to detect series quasi-arc. This algorithm analyzes odd and even harmonics until 9th using discrete fourier transform (DFT) and detect series arc comparing RMS values of load current. Resistors, lights, dimmer and vacuum cleaner which can be distinguished linearity load and quasi arc load are adopted to perform experiments. This algorithm is confirmed to emulate arc detecting with measuring current data.

An Efficiency-Optimized Modulation Strategy for Dual-Active-Bridge DC-DC Converters Using Dual-Pulse-Width-Modulation in the Low Power Region

  • Byen, Byeng-Joo;Ban, Chung-Hwan;Lim, Young-Bae;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • 제17권6호
    • /
    • pp.1413-1421
    • /
    • 2017
  • In order to control the output voltage in a dual active bridge converter, this paper establishes a theoretical inductor current equation for a dual-pulse-width-modulation scheme that ensures low switching loss. It also proposes a modulation strategy that minimizes conduction loss. When compared to the conventional single-pulse-width-modulation strategy, the proposed approach can reduce the inductor current RMS and improve efficiency in the low power region, as verified through simulation and experimental results.

Electrochemical Frequency Modulation: Solution Resistance and Double Layer Capacitance Considerations

  • Lalvani, Shashi;Ullah, Sifat;Kerr, Lei
    • Corrosion Science and Technology
    • /
    • 제20권5호
    • /
    • pp.231-241
    • /
    • 2021
  • The objective of this study was to evaluate total current under steady-state conditions for a material undergoing corrosion using the electrochemical frequency modulation (EFM) technique, taking into account the presence of solution resistance and double layer capacitance. The analysis involving linearization of the Tafel curve allowed for the estimation of corrosion parameters. Results showed that the output signal was dependent on fundamental frequencies and their multiples. In addition, the output signal almost manifested itself at frequencies that were sums of fundamental frequencies of the applied sinusoidal signal. The harmonics calculated showed a significant shift from the principal frequency of input signals. The investigation involved the influence of corrosion current and anode-to-cathode Tafel slope ratio on faradaic and non-faradaic currents (including the average and RMS). The model presented showed both qualitative and quantitative improvements over the previously developed EFM technique that ignored the influence of solution resistance and the double layer capacitance while assuming the applied DC potential corresponded to the corrosion potential of the corroding material.

넓은 입력전압 범위에서 높은 효율을 가지는 위상천이 풀브릿지 컨버터 (A High Efficiency Phase-Shifted Full-Bridge Converter with Wide Input Voltage Range)

  • 한정규;최승현;문건우
    • 전력전자학회논문지
    • /
    • 제24권1호
    • /
    • pp.66-69
    • /
    • 2019
  • This study proposes a high-efficiency phase-shifted full-bridge (PSFB) converter with a wide input voltage range. The conventional PSFB converter is a useful topology in high-power applications. This converter not only achieves the zero-voltage switching of the primary switches, but also has small RMS current in the primary side. However, because the conventional PSFB converter has large freewheeling current in the primary side when it is designed considering the hold-up time of the converter, such a converter has high conduction loss at the primary switches. To solve this problem, a new PSFB converter is proposed in this study. The experiment is implemented with an input voltage ranging from a 320 V-400 V and an output power specification of 715 W.

자속구속형 초전도 전류제한기의 용량증대를 위한 동작특성 (Operating Characteristics of Capacity Increase in a Flux-Lock Type Superconducting Fault Current Limiter)

  • 남긍현;최효상;박형민;조용선;이나영;한태희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.200-202
    • /
    • 2006
  • We investigated the operating characteristics of a flux-lock type superconducting fault current limiters according to the number of the serial connection each the superconducting element at the additive polarity winding of a transformer. This SFCL consists of two coils wound in parallel on the same iron core, and the secondary coil is connected to the elements in series. Operating characteristics can be controlled by adjusting the inductances and the winding directions of the coils. It turns ratio between the primary and the secondary coils is 63:21. The analysis of voltage, current, and resistance in serial connection each element was performed to increase the applied voltage of flux-lock type SFCL. When the applied voltage was 200/$\sqrt{3}[V_{rms}]$ with three elements connected in seres, the peak value of the line current increased up to 26,24[A]. On the other hands, resistive SFCL increased up to 36.35[A], under the same conditions. This enabled the flux-lock type SFCL to be easy to increase the capacity of power system.

  • PDF