• Title/Summary/Keyword: RISE program

Search Result 489, Processing Time 0.024 seconds

Anti-fuse program circuits for configuration of the programmable logic device

  • Kim, Phil-Jung;Gu, Dae-Sung;Jung, Rae-Sung;Park, Hyun-Yong;Kim, Jong-Bin
    • Proceedings of the IEEK Conference
    • /
    • 2002.07b
    • /
    • pp.778-781
    • /
    • 2002
  • In this paper, we designed the anti-fuse program circuit, and there are an anti-fuse program/sense/latch circuit, a negative voltage generator, power-up circuit and etc. in this circuit. An output voltage of a negative voltage generator is about -4,51V. We detected certainly it regardless of simulation result power rise time or temperature change to detect the anti-fuse program state of an anti-fuse program/sense/latch circuit and were able to know what performed a steady action. And as a result of having done a simulation while will change a resistance value voluntarily in order to check an anti-fuse resistance characteristic of this circuit oneself, it recognized as a programmed anti-fuse until 23k$\Omega$, and we were able to know that this circuit was a lot of margin than general anti-fuse resistance 500$\Omega$. Therefore, the anti-fuse program circuit of this study showed that was able to apply for configuration of the programmable logic device.

  • PDF

A Study on the Remodeling Design Direction of the Community Center for Neighborhood Regeneration (근린재생을 위한 동 주민센터의 리모델링 계획방향 연구)

  • Yoo, Hae-Yeon;Song, Jun-Yeop
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.9
    • /
    • pp.43-54
    • /
    • 2018
  • Recently, residents' community center is trying to combine with various program and facilities as the residents self-government program's development. This is due to the reduction of administrative tasks, the computerization of programs, the importance of community participation activities, the activation of community, and the increase of welfare projects. Therefore, previous studies on program complexity have been actively carried out. Nevertheless, spaces and programs studies of considering regional characteristics are lacking. Therefore, the community centers' program and spaces need to change. Therefore, this study propose an improvement direction through analyzing the situation of the residents' community center. For this study, the precedent research and institutional limitations are examined. In addition, this study selected and analyzed the 15 local community center. Thirdly, interviews were conducted with users and officials of the 5 residents' community centers on major changes. Finally, This study suggests direction of program improvement and architectural design direction. As a result of this study, integrated management measures with overlapping agencies should be sought. Surplus space will have to be rearranged into a new program through prior examination. Above all, the proposed remodeling guidelines require user requirements to be reflected and designed with the residents.

The Effect of a Forest Healing Program on Cognitive Function, Depression, Anxiety, and Cortisol Levels in Elderly People

  • Soyeon, Kim;Jungkee, Choi
    • Journal of Forest and Environmental Science
    • /
    • v.38 no.4
    • /
    • pp.290-301
    • /
    • 2022
  • Increasing life expectancy leads to a rise in the prevalence of aging-related mental diseases and a concomitant increase in the financial and societal pressures related to their prevention and management. This issue is attracting increasing attention from researchers. Therefore, this study aimed to determine whether a healing program in a forest environment is effective for improving cognitive function, depression, anxiety, and stress in elderly people. A nonequivalent control group pretest-posttest design was used. The experimental group consisted of 18 males and females aged 60 to 80 years who participated in a forest healing program for seven days, while the comparison group comprised 10 people with similar demographics. For the process of data analysis, this study performed a cross-analysis to determine the homogeneity of the data and carried out the Wilcoxon signed-rank test, a nonparametric statistical test, to verify the significance of each group. Participation in the forest healing program led to a significant improve-ment in cognitive function (p=0.030). The levels of depression decreased, but this result was not statistically significant. The levels of anxiety decreased significantly (p=0.004). The mean cortisol score, a measurement of stress, decreased, but it was not statistically significant. These findings confirmed the effectiveness of this program for improving certain mental conditions of elderly people, and affirmed that the use of long-term forest healing programs can be expected to alleviate national pressures created by aging societies.

A Study on the Structural Behavior in Mass Concrete Box Rahmen due to Hydration Heat (수화열에 의한 매스콘크리트 박스 라멘 구조물의 구조거동 연구)

  • 조병완;김영진;허민희
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.349-352
    • /
    • 1999
  • Concrete cracks due to hydration heat are a serious problem, particularly in mass concrete structures such as box rahmen, dam or footing of pier, etc.. As a result of the temperature rise and restriction condition of foundation, the thermal stress which may induce the cracks can occur. In this, study, ABAQUS program package was used to calculate the temperature distributions generated by hydration heat and the thermal stress in box rahmen structure which have thickness of 1.7~2.2m, and applied for various equations of adiabatic temperature rise such as korean code, japanese code, convection coefficient and low heat cement code.

  • PDF

Structural Analysis and Towing Test for Predicting Drag Coefficients of a Very High-rise Steel Artificial Reef (초고층 강제어초의 유체력 산출을 위한 예인시험 및 구조해석)

  • Hyun-Kyoung Shin;Ho-Gyun Park
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.38 no.2
    • /
    • pp.44-52
    • /
    • 2001
  • A modeling program was developed in Part I which represents the 3-D geometry, produces bill of material, automatically draws drawings and produces input data for structural analysis of Very High-rise Steel Artificial Reefs(VEHSAR). Model tests were carried out to measure drag forces acted on VEHSAR in the Ocean Engineering Wide Tank, the University of Ulsan and structural analyses were made to simulate structural behaviors of VEHSAR. The integrated package system is suggested to design VEHSAR with different geometries.

  • PDF

Themal Stress Analysis of the Heat of Hydration Considering Pipe-Cooling (파이프 쿨링을 고려한 수화열 해석기법에 관한연구)

  • 긴진근;김국한;최계식;양주경;최고일
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.04a
    • /
    • pp.274-279
    • /
    • 1995
  • The heat of hyderation of cement causes the internal temperature rise and volume change at early age, paticular in massive concrete structures. As the results of the temperature rise and extenal restraint conditions, the themal stress may induce cracks in concrete. Therefore various techenuques of the themal stress control of the mass concrete has been widely used. One of these techniques is pipe-cooling which is considered in this study. The objective of this paper is to develop finite element program which is capable of simulating the temperature history and the thermal stress considering pipe-cooling, creep and the modified elastic modulus dud to maturity effect.

  • PDF

Parametric Study for Reduction of Heat of Hydration in Mass Concrete (매스콘크리트 구조물의 수화열 저감을 위한 매개변수 연구)

  • 심종성;문도영;최광민
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.29-34
    • /
    • 2002
  • The heat of hydration of cement causes the internal temperature rise at early age, paticular in massive concrete structures. As the results of the temperature rise and restraint condition, the thermal stress may induce cracks in concrete. The prediction of the thermal stress is important in design and construction stages in order to control the cracks in mass concrete. It is poor economy to analysis for prediction of the thermal stress on each design or construction. In this study, the hydration heat and thermal stress analysis is performed by ABAQUS program, as a results of thermal analysis, the formula of size-placing depth relationship is proposed.

  • PDF

Telescopic columns as a new base isolation system for vibration control of high-rise buildings

  • Hosseini, Mahmood;Farsangi, Ehsan Noroozinejad
    • Earthquakes and Structures
    • /
    • v.3 no.6
    • /
    • pp.853-867
    • /
    • 2012
  • In this paper, a new type of passive energy dissipating system similar to added damping and stiffness (ADAS) and triangular added damping and stiffness (TADAS) is proposed and implemented in the analytical model of a building with hybrid structural system in the structure's base which we call it; Telescopic column. The behavior and performance of a high rise R.C. structure equipped with this system is investigated and compared with conventional base isolation systems such as rubber isolator bearings and friction pendulum bearings. For this purpose a series of ground acceleration records of the San Fernando, Long Beach and Imperial Valley earthquakes are used as the disturbing ground motions in a series of numerical simulations. The nonlinear numerical modeling which includes both material and geometric nonlinearities were carried out by using SAP2000 program. Results show suitable behavior of structures equipped with telescopic columns in controlling the upper stories drifts and accelerations.

Transient Voltage Analysis of Low-Voltage Source Circuit inn Thermal Power Plant due to Grounding Potential Rise by Lightening (낙뢰침입에 의한 대지전위상승이 발전소 저압전원회로에 미치는 과전압 해석)

  • Yang, Byeong-Mo;Jeong, Jae-Kee;Min, Byeong-Wook;Lee, Jong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1644-1646
    • /
    • 1998
  • High-Smokestacks have been the symbol of the thermal power plant. Those cause the thermal power plant to be damaged by lightening for reaching several hundreds meter. In this paper, we investigated the accident of low-voltage source circuit due to grounding potential rise by lightening via high-smokestack in practically driving power plant, described examination into the cause and the impulse analysis. We analysed the transient voltage by EMTP(ElectroMagnetic Transient Program) via modeling the grounding system of power plant. This theoretical results coincided with practical accidental state. Therefore, it was verified that we could apply the grounding system of power plant and substation with the distribution-circuit analysis(EMTP).

  • PDF

Electrostatic Discharge Analysis of n-MOSFET (n-MOSFET 정전기 방전 분석)

  • 차영호;권태하;최혁환
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.8
    • /
    • pp.587-595
    • /
    • 1998
  • Transient thermal analysis simulations are carried out using a modeling program to understand the human body model HBM ESD. The devices were simulated a one-dimensional device subjected to ESD stress by solving Poison's equation, the continuity equation, and heat flow equation. A ramp rise with peak ESD voltage during rise time is applied to the device under test and then discharged exponentially through the device. LDD and NMOS structures were studied to evaluate ESD performance, snap back voltages, device heating. Junction heating results in the necessity for increased electron concentration in the space charge region to carry the current by the ESD HBM circuit. The doping profile adihacent to junction determines the amount of charge density and magnitude of the electric field, potential drop, and device heating. Shallow slopes of LDD tend to collect the negative charge and higher potential drops and device heating.

  • PDF