• Title/Summary/Keyword: RISE

Search Result 10,881, Processing Time 0.036 seconds

Analysis of Factors Increasing Construction Cost for the Curtain-wall Accompanied by the Installation of a Guide Rail for High-rise Building Maintenance (초고층 외벽 유지관리용 Guide Rail 설치에 따른 커튼월 공사비 증가요인 분석)

  • Kim, Chang-Han;Han, Jae-Goo;Kim, Kyoon-Tai
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05b
    • /
    • pp.97-98
    • /
    • 2011
  • The number of high-rise buildings has increased year after year, with there currently being 5 projects in progress to construct buildings higher than 100 stories in Seoul alone. The construction cost for such high-rise buildings is significantly higher than the cost for a conventional low-rise building, while maintenance costs are expected to be two to three times higher. To reduce the maintenance cost of a high-rise building, there is the need for a guide rail to be used for maintenance, which is why there is the need for research on the guide rail system. For this reason, as preliminary research to develop a guide rail, this study aims to derive the factors increasing construction cost by taking the installation of a guide rail into account. This is expected to lay the groundwork for the design and construction of guide rails for high-rise building maintenance.

  • PDF

Comparison on Terror Risk of Large Space Structures and High-rise Buildings in Korea (국내 대공간 건축물과 고층 건축물의 테러위험도 비교)

  • Song, Jin-Young;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.1
    • /
    • pp.105-113
    • /
    • 2016
  • Since the 1980s, the number of large space buildings in Korea has consistently been increasing due to large scale international competitions such as the Olympics and the World Cup, demands for environmental improvement, and development of structural systems. Due to these reasons, this paper conducted a comparative analysis on terrorism risk factors of large space structure and skyscrapers in Korea. The results suggest that the total risk level of high-rise and large space structure was "medium level risk" and that the terrorism risk level for large space structure was as high as that for high-rise buildings. As it relates to the risk levels depending on scenarios, terrorism risks to large space structure were higher than high-rise buildings in the "internal explosion" and "internal intrusion" categories. And the results of analyzing explosion-related scenarios except for CBR suggest that terrorism risks to large space structure were highest when it comes to Internal-Explosive followed by Internal-Intrusion and Explosive-Zone I; and the results showed a regular pattern. On the other hand, in the case of high-rise buildings, terrorism risks were highest in Internal-Explosive followed by Explosive-Zone I and Explosive-Zone II; and the results showed an irregular pattern.

A Basic Study on the Evacuation Safety Performance of High-rise Apartment Building (고층 공동주택의 피난성능에 관한 기초적 연구)

  • 이용재
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.75-83
    • /
    • 2001
  • It has been recognized that the evacuation planning is very important for effective evacuation of occupants on fire event. However the present evacuation planning and regulation for fire safety usually tend to meet the minimum requirements based on the existing laws and regulations. The ultimate goal of the evacuation planning is evacuate occupants rapidly from building fires to the safe areas. In this study, First, analyzed occupants load density and occupants characteristics in high-rise apartment buildings, Second, A evacuation safety performance of high-rise apartment buildings was analyzed with various typical floor plans. The purpose of this study is to figure out the evacuation characteristics in high-rise apartment buildings and improve countermeasure through comparative study on the Evacuation regulation and floor plans for High-rise Apartment buildings.

  • PDF

A Study on Problems of High-rise Building Fires in Korea and the Basic Directions for Fire Safety of High-rise Building Design (우리나라 고층건축화재의 문제점과 그 대책의 기본방향에 관한 연구)

  • 이강훈
    • Fire Science and Engineering
    • /
    • v.4 no.2
    • /
    • pp.15-26
    • /
    • 1990
  • Building become higher. larger and more complex than ever before, showing abrupt changes in building structures. forms and mechanical systems. Likewise hazads of fire and the scale of fire losses become more and more greater. Therefore. considerations for fire safety take up great portion of the building design process. In this study, problems of high-rise building fires and basic directions for fire safety of high-rise building design were studied through the statistical analysis of 138 fire cases. The results of this study are summarized as follows : ·Most of the fires in high-rise building occur on the low floors and the fire frequencies are very low on the upper floors. Fire casualties are liable to be more on the upper floors than on tile floor of fire origin. ·The important causes of evacuation failures were analyzed as being late in escape and lack of stairwell enclosures. ·The main cause of vertical fire spread is lack of stairwell enclosures. However, the fire spreads mainly through the enterior windows in apartment houses. The combustible materials in buildings act on as the major factors of horizontal fire spread and the improper fire doors play role of another the critical causes. ·The basic directions for fire safety of high-rise building design put much stress firstly on the compartmentation of the buildings effectively performing the provision of safe escape routes and the safe refuse places in buildings.

  • PDF

Optimal intensity measures for probabilistic seismic demand models of RC high-rise buildings

  • Pejovic, Jelena R.;Serdar, Nina N.;Pejovic, Radenko R.
    • Earthquakes and Structures
    • /
    • v.13 no.3
    • /
    • pp.221-230
    • /
    • 2017
  • One of the important phases of probabilistic performance-based methodology is establishing appropriate probabilistic seismic demand models (PSDMs). These demand models relate ground motion intensity measures (IMs) to demand measures (DMs). The objective of this paper is selection of the optimal IMs in probabilistic seismic demand analysis (PSDA) of the RC high-rise buildings. In selection process features such as: efficiency, practically, proficiency and sufficiency are considered. RC high-rise buildings with core wall structural system are selected as a case study building class with the three characteristic heights: 20-storey, 30-storey and 40-storey. In order to determine the most optimal IMs, 720 nonlinear time-history analyses are conducted for 60 ground motion records with a wide range of magnitudes and distances to source, and for various soil types, thus taking into account uncertainties during ground motion selection. The non-linear 3D models of the case study buildings are constructed. A detailed regression analysis and statistical processing of results are performed and appropriate PSDMs for the RC high-rise building are derived. Analyzing a large number of results it are adopted conclusions on the optimality of individual ground motion IMs for the RC high-rise building.

A Study on the Bubble Behavior in the Vertical-upward Gas Injection (수직상향 기체주입시 기포거동에 관한 연구)

  • Seo, Dong-Pyo;Oh, Yool-Kwon
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.712-716
    • /
    • 2003
  • In the present study, the gas injection system based on air-water model was designed to investigate the behavior characteristics of bubbles injected into a ladle. The parameters such as gas volume fraction and bubble rise velocity were exprementally measured in a gas-liquid flow region. To measure gas volume fraction, an electo-conductivity probe was used and bubble rise velocity was obtained by a high speed CCD camera. Gas volume fraction was symmetric to the axis of nozzle secured on the bottom of a ladle. The bubble rise velocity was calculated for two different experimental conditions. That is, gas flow conditions were following two case: 1) Q = $0.63{\times}10^{-4}$ $m^{3}/s$, 2) $1.26{\times}10^{-4}$ $m^{3}/s$. As a gas injected into the liquid ladle, the liquid-phase region is circulated by bubbles' behavior. The bubble rise velocity was influenced of the circulation flow of liquid phase. As a result, the bubble rise velocity was appeared higher middle region of ladle than near the nozzle.

  • PDF

The Analysis CO2 Emission and Economic Efficiency of High-rise Apartment Houses (초고층 공동주택의 CO2 배출량과 경제성 분석에 관한 연구)

  • Roh, Seung-Jun;Tae, Sung-Ho;Kim, Tae-Hyoung;Keum, Won-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.47-48
    • /
    • 2012
  • In this study, the CO2 emission and economic efficiency of high-rise apartment houses were evaluated, and were analyzed as a way to establish database on the evaluation of environment-friendliness of high-rise buildings. To that end, standard of buildings to be evaluated were proposed through analysis of the designing guideline for high-rise apartment houses proposed by Seoul city, and CO2 emission of the subject buildings were evaluated based on the characteristics of materials admitted into each building and the amounts of energy consumed during lifecycle period. In addition, the initial costs in construction stage and annual costs in operation stage were set as analysis parameters, and along with calculation of direct cost by the consumption of construction materials and energy, the costs of CO2 emission were evaluated and analyzed. As a result, the CO2 emission and economic efficiencies of high-rise apartment houses by construction stage and operation stage could be analyzed quantitatively.

  • PDF

Contents Analysis on the Dwellers' Medical Reports in High-Rise Mixed-Use Apartment (주상복합아파트 거주자의 질병자료에 관한 내용 분석)

  • Choi, Byung-Sook;Kang, In-Ho
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.187-192
    • /
    • 2008
  • This purpose of this study is to figure out the inter-relationship between the residence stories in high-rise mixed-use apartments and their residents' disease patterns throughout the dweller's medical reports in high-rise mixed-use apartments. Research basic data are obtained from medical fee request of National Health Insurance Corportion. Data are limited a housing complex to 'A' high-rise mixed-use apartment and a medical treatment time to 3 years(2004-2006). Analysis data of total 346,286 medical records, 43,159 disease records, and 8,999 persons are collected. By analyzing those data, findings are as follows: 1) Women is more medical treatments than men, 40-50 age group is more treated, and the residents of 6-25 stories are more received medical treatments. Diseases of the respiratory system and diseases of the eye and adnexa are relatively treated higher than other diseases. 2) The diseases of the respiratory system, the eye and adnexa, the skin and subcutaneous tissue, the ear and mastoid process), and the asthma have not relation to the high-storied residence through the data of disease records and personal records. But the analysis on the data of children, 7 ages and less, is showed a significant relation. And to conclude, there is no relationship between the residence of high-stories in that apartment and dwellers' disease patterns, but there is a little probable to the relationship in the pre-school child.

  • PDF

Life-cycle Environmental Impact Assessment of High-rise Apartments

  • Kim, Samuel;Kim, Se-Hwan;Lee, Sung
    • Architectural research
    • /
    • v.3 no.1
    • /
    • pp.29-36
    • /
    • 2001
  • Concern about global environment has been increasing in recent years. Efforts to minimize the environmental impact to the globe as well as human beings have increased, especially in the late twentieth century. The study researches one of the solutions for the environmentally friendly building construction, which can contribute to sustaining the world environment. Assessment and proposals are made for high-rise apartments, one of the most popular construction types nowadays in Korea. Since the volume of high-rise apartment construction is so great, a small improvement in each building will make a great contribution. Assessments are made over the life-span of apartment buildings. A tool named EIAHA (Environmental Impact Assessment for High-rise Apartment) has been made through references from western examples, mainly in the UK. The components of EIAHA include passive design strategies, building materials, energy consumption during building operation and management/maintenance. Although the issues are on a global scale, solutions are sought on regional scale. Korean high-rise apartments are assessed with the tool and suggestions for sustainable development are made mainly for improvement of embodied energy of building materials and the life of buildings.

  • PDF

Pedestrian Distribution in High-Rise Commercial Complexes: An Analysis of Integrating Spatial and Functional Factors

  • Xu, Leiqing;Xia, Zhengwei
    • International Journal of High-Rise Buildings
    • /
    • v.5 no.2
    • /
    • pp.95-103
    • /
    • 2016
  • One of the key problems in the design of high-rise commercial complex is how to guide reasonable pedestrian distribution in commercial space. In this study, pedestrian distribution in three high-rise commercial complexes in Shanghai and Hong Kong was studied using spatial configuration analysis software Space Syntax and quantification of physical elements in commercial spaces, such as functional attractiveness, entrances, escalators, level variations and passage width. Additionally, in an attempt to integrate functions with spatial integration and spatial depth, two combination variables, the spatial coefficient of function (IF) and spatial depth coefficient of function (F/D), were proposed. The results of the correlation analysis and multiple regression analyses reflected the following: (1) Regarding the influence on pedestrian distribution, there was a synergistic and complementary relationship between function and space; (2) The comprehensive flow distribution analytic model could successfully interpret flow distribution in high-rise commercial complexes and its R Square ranged up to about 70% in the three cases; (3) The spatial coefficient of function (IF) and spatial depth coefficient (F/D) could effectively integrate functions and spatial configuration, which could help close the gap between over-emphasis on function in commercial research and the lack of consideration of function in space-syntax analysis.