• Title/Summary/Keyword: RIO

Search Result 391, Processing Time 0.03 seconds

The use of auxiliary devices during irrigation to increase the cleaning ability of a chelating agent

  • Prado, Marina Carvalho;Leal, Fernanda;Simao, Renata Antoun;Gusman, Heloisa;do Prado, Maira
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.2
    • /
    • pp.105-110
    • /
    • 2017
  • Objectives: This study investigated the cleaning ability of ultrasonically activated irrigation (UAI) and a novel activation system with reciprocating motion (EC, EasyClean, Easy Equipamentos $Odontol\acute{o}gicos$) when used with a relatively new chelating agent (QMix, Dentsply). In addition, the effect of QMix solution when used for a shorter (1 minute) and a longer application time (3 minutes) was investigated. Materials and Methods: Fifty permanent human teeth were prepared with K3 rotary system and 6% sodium hypochlorite. Samples were randomly assigned to five groups (n = 10) according to the final irrigation protocol: G1, negative control (distilled water); G2, positive control (QMix 1 minute); G3, QMix 1 minute/UAI; G4, QMix 1 minute/EC; G5, QMix 3 minutes. Subsequently the teeth were prepared and three photomicrographs were obtained in each root third of root walls, by scanning electron microscopy. Two blinded and pre-calibrated examiners evaluated the images using a four-category scoring system. Data were statistically analyzed using Kruskal-Wallis and Dunn tests (p < 0.05). Results: There were differences among groups (p < 0.05). UAI showed better cleaning ability than EC (p < 0.05). There were improvements when QMix was used with auxiliary devices in comparison with conventional irrigation (p < 0.05). Conventional irrigation for 3 minutes presented significantly better results than its use for 1 minute (p < 0.05). Conclusions: QMix should be used for 1 minute when it is used with UAI, since this final irrigation protocol showed the best performance and also allowed clinical optimization of this procedure.

Influence of autoclave sterilization procedures on the cyclic fatigue resistance of heat-treated nickel-titanium instruments: a systematic review

  • Silva, Emmanuel Joao Nogueira Leal;Zanon, Mayara;Hecksher, Fernanda;Belladonna, Felipe Goncalves;de Vasconcelos, Rafaela Andrade;da Silva Fidalgo, Tatiana Kelly
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.2
    • /
    • pp.25.1-25.12
    • /
    • 2020
  • Objectives: This systematic review evaluated the influence of autoclave sterilization procedures on the cyclic fatigue resistance of heat-treated nickel-titanium (NiTi) instruments. Materials and Methods: A systematic search without restrictions was conducted in the following electronic databases: PubMed, Scopus, Web of Science, ScienceDirect, Cochrane, and Open Grey. The hand search was also performed in the main endodontic journals. The eligible studies were submitted to the methodological assessment and data extraction. Results: From 203 abstracts, a total of 10 articles matched the eligible criteria. After reading the full articles, 2 were excluded because of the absence of the heat-treated instruments in the experimental design and 3 due to the lack of a control group using heat-treated instruments without autoclave sterilization. From the 5 included studies, 1 presented a low risk of bias, 3 presented moderate and 1 high risk. It was observed heterogeneous findings in the included studies, with autoclave sterilization cycles increasing, decreasing or not affecting the cyclic fatigue life of heat-treated NiTi instruments. However, the retrieved studies evaluating the cyclic fatigue resistance of endodontic instruments presented different protocols and assessing outcomes, this variability makes the findings less comparable within and also between groups and preclude the establishment of an unbiased scientific evidence base. Conclusions: Considering the little scientific evidence and considerable risk of bias, it is still possible to conclude that autoclave sterilization procedures appear to influence the cyclic fatigue resistance of heat-treated NiTi instruments.

Statistical bias indicators for the long-term displacement of steel-concrete composite beams

  • Moreno, Julian A.;Tamayo, Jorge L.P.;Morsch, Inacio B.;Miranda, Marcela P.;Reginato, Lucas H.
    • Computers and Concrete
    • /
    • v.24 no.4
    • /
    • pp.379-397
    • /
    • 2019
  • Steel-concrete composite beams are widely employed in constructions and their performance at the serviceability stage is of concern among practitioners and design regulations. In this context, an accurate evaluation of long-term deflections via various rheological concrete models is needed. In this work, the performance and predict capability of some concrete creep and shrinkage models ACI, CEB, B3, FIB and GL2000 are ascertained, and compared by using statistical bias indicators. Ten steel-concrete composite beams with existing experimental and numerical results are then modeled for this purpose. The proposed modeling technique uses the finite element method, where the concrete slab and steel beam are modeled with shell finite elements. Concrete is considered as an aging viscoelastic material and cracking is treated with the common smeared approach. The results show that when the experimental ultimate shrinkage strain is used for calibration, all studied rheological models predict nearly similar deflections, which agree with the experimental data. In contrast, significance differences are encountered for some models, when none calibration is made prior to. A value between twenty and thirty times the cracking strain is recommended for the ultimate tensile strain in the tension stiffening model. Also, increasing the relative humidity and decreasing the ambient temperature can lead to a substantial reduction of slab cracking for beams under negative flexure. Finally, there is not a unique rheological model that clearly excels in all scenarios.

Inclusion of bioclimatic variables in genetic evaluations of dairy cattle

  • Negri, Renata;Aguilar, Ignacio;Feltes, Giovani Luis;Machado, Juliana Dementshuk;Neto, Jose Braccini;Costa-Maia, Fabiana Martins;Cobuci, Jaime Araujo
    • Animal Bioscience
    • /
    • v.34 no.2
    • /
    • pp.163-171
    • /
    • 2021
  • Objective: Considering the importance of dairy farming and the negative effects of heat stress, more tolerant genotypes need to be identified. The objective of this study was to investigate the effect of heat stress via temperature-humidity index (THI) and diurnal temperature variation (DTV) in the genetic evaluations for daily milk yield of Holstein dairy cattle, using random regression models. Methods: The data comprised 94,549 test-day records of 11,294 first parity Holstein cows from Brazil, collected from 1997 to 2013, and bioclimatic data (THI and DTV) from 18 weather stations. Least square linear regression models were used to determine the THI and DTV thresholds for milk yield losses caused by heat stress. In addition to the standard model (SM, without bioclimatic variables), THI and DTV were combined in various ways and tested for different days, totaling 41 models. Results: The THI and DTV thresholds for milk yield losses was THI = 74 (-0.106 kg/d/THI) and DTV = 13 (-0.045 kg/d/DTV). The model that included THI and DTV as fixed effects, considering the two-day average, presented better fit (-2logL, Akaike information criterion, and Bayesian information criterion). The estimated breeding values (EBVs) and the reliabilities of the EBVs improved when using this model. Conclusion: Sires are re-ranking when heat stress indicators are included in the model. Genetic evaluation using the mean of two days of THI and DTV as fixed effect, improved EBVs and EBVs reliability.

A novel radioactive particle tracking algorithm based on deep rectifier neural network

  • Dam, Roos Sophia de Freitas;dos Santos, Marcelo Carvalho;do Desterro, Filipe Santana Moreira;Salgado, William Luna;Schirru, Roberto;Salgado, Cesar Marques
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2334-2340
    • /
    • 2021
  • Radioactive particle tracking (RPT) is a minimally invasive nuclear technique that tracks a radioactive particle inside a volume of interest by means of a mathematical location algorithm. During the past decades, many algorithms have been developed including ones based on artificial intelligence techniques. In this study, RPT technique is applied in a simulated test section that employs a simplified mixer filled with concrete, six scintillator detectors and a137Cs radioactive particle emitting gamma rays of 662 keV. The test section was developed using MCNPX code, which is a mathematical code based on Monte Carlo simulation, and 3516 different radioactive particle positions (x,y,z) were simulated. Novelty of this paper is the use of a location algorithm based on a deep learning model, more specifically a 6-layers deep rectifier neural network (DRNN), in which hyperparameters were defined using a Bayesian optimization method. DRNN is a type of deep feedforward neural network that substitutes the usual sigmoid based activation functions, traditionally used in vanilla Multilayer Perceptron Networks, for rectified activation functions. Results show the great accuracy of the DRNN in a RPT tracking system. Root mean squared error for x, y and coordinates of the radioactive particle is, respectively, 0.03064, 0.02523 and 0.07653.

Conventional and digital impressions for complete-arch implant-supported fixed prostheses: time, implant quantity effect and patient satisfaction

  • Pereira, Ana Larisse Carneiro;Medeiros, Vitoria Ramos;Campos, Maria de Fatima Trindade Pinto;Medeiros, Annie Karoline Bezerra de;Yilmaz, Burak;Carreiro, Adriana da Fonte Porto
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.4
    • /
    • pp.212-222
    • /
    • 2022
  • PURPOSE. To evaluate and compare the effect of impression type (conventional vs digital) and the number of implants on the time from the impressions to the generation of working casts of mandibular implant-supported fixed completearch frameworks, as well as on patient satisfaction. MATERIALS AND METHODS. 17 participants, 3 or 4 implants, received 2 types of digital impression methods (DI) and conventional (CI). In DI, two techniques were performed: scanning with the scan bodies (SC) and scanning with a device attached to the scan bodies (SD) (BR 10 2019 026265 6). In CI, the making of a solid index (SI) and open-tray impression (OT) were used. The outcomes were used to evaluate the time and the participant satisfaction with conventional and digital impressions. The time was evaluated through the timing of the time obtained in the workflow in the conventional and digital impression. The effect of the number of implants on time was also assessed. Satisfaction was assessed through a questionnaire based on seven. The Wilcoxon test used to identify the statistical difference between the groups in terms of time. The Mann-Whitney test was used to analyze the relationship between the time and the number of implants. Fisher's test was used to assess the patient satisfaction (P<.05). RESULTS. The time with DI was shorter than with CI (DI, $\tilde{x}=02:58$; CI, $\tilde{x}=31:48$) (P<.0001). The arches rehabilitated with 3 implants required shorter digital impression time (3: $\tilde{x}=05:36$; 4: $\tilde{x}=09:16$) (P<.0001). Regarding satisfaction, the DI was more comfortable and pain-free than the CI (P<.005). CONCLUSION. Digital impressions required shorter chair time and had higher patient acceptance than conventional impressions.

Dentinal tubule penetration of sodium hypochlorite in root canals with and without mechanical preparation and different irrigant activation methods

  • Renata Aqel de Oliveira;Theodoro Weissheimer;Gabriel Barcelos So ;Ricardo Abreu da Rosa ;Matheus Albino Souza;Rodrigo Goncalves Ribeiro ;Marcus Vinicius Reis So
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.1
    • /
    • pp.1.1-1.11
    • /
    • 2023
  • Objectives: This study evaluated the dentinal penetration depth of 2.5% sodium hypochlorite (NaOCl) in root canals with and without preparation and different irrigant activation protocols. Materials and Methods: Sixty-three bovine mandibular incisors were randomly allocated to 6 groups (n = 10): G1, preparation + conventional needle irrigation (CNI); G2, preparation + passive ultrasonic irrigation (PUI); G3, preparation + Odous Clean (OC); G4, no preparation + CNI; G5, no preparation + PUI; G6, no preparation + OC; and CG (negative control; n = 3). Samples were filled with crystal violet for 72 hours. Irrigant activation was performed. Samples were sectioned perpendicularly along the long axis, 3 mm and 7 mm from the apex. Images of the root thirds of each block were captured with a stereomicroscope and analyzed with an image analysis software. One-way analysis of variance, followed by the Tukey post hoc test, and the Student's t-test were used for data analysis, with a significance level of 5%. Results: The NaOCl penetration depth was similar when preparation was performed, regardless of the method of irrigation activation (p > 0.05). In the groups without preparation, G6 showed greater NaOCl penetration depth (p < 0.05). The groups without preparation had a greater NaOCl penetration depth than those with preparation (p = 0.0019). Conclusions: The NaOCl penetration depth was similar in groups with root canal preparation. Without root canal preparation, OC allowed deeper NaOCl penetration. The groups without preparation had greater NaOCl penetration than those undergoing root canal preparation.

Ten years of minimally invasive access cavities in Endodontics: a bibliometric analysis of the 25 most-cited studies

  • Emmanuel Joao Nogueira Leal Silva ;Karem Paula Pinto ;Natasha C. Ajuz ;Luciana Moura Sassone
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.3
    • /
    • pp.42.1-42.15
    • /
    • 2021
  • Objectives: This study aimed to analyze the main features of the 25 most-cited articles in minimally invasive access cavities. Materials and Methods: An electronic search was conducted on the Clarivate Analytics' Web of Science 'All Databases' to identify the most-cited articles related to this topic. Citation counts were cross-matched with data from Elsevier's Scopus and Google Scholar. Information about authors, contributing institutions and countries, year and journal of publication, study design and topic, access cavity, and keywords were analyzed. Results: The top 25 most-cited articles received a total of 572 (Web of Science), 1,160 (Google Scholar) and 631 (Scopus) citations. It was observed a positive significant association between the number of citations and age of publication (r = 0.6907, p < 0.0001); however, there was no significant association regarding citation density and age of publication (r = -0.2631, p = 0.2038). The Journal of Endodontics made the highest contribution (n = 15, 60%). The United States had the largest number of publications (n = 7) followed by Brazil (n = 4), with the most contributions from the University of Tennessee and Grande Rio University (n = 3), respectively. The highest number of most-cited articles were ex vivo studies (n = 16), and 'fracture resistance' was the major topic studied (n = 10). Conclusions: This study revealed a growing interest for researchers in the field of minimally invasive access cavities. Future trends are focused on the expansion of collaborative networks and the conduction of laboratory studies on under-investigated parameters.

Impact of dental imaging on pregnant women and recommendations for fetal radiation safety: A systematic review

  • Thiago Oliveira Gamba;Fernanda Visioli;Deise Renata Bringmann;Pantelis Varvaki Rados;Heraldo Luis Dias da Silveira;Isadora Luana Flores
    • Imaging Science in Dentistry
    • /
    • v.54 no.1
    • /
    • pp.1-11
    • /
    • 2024
  • Purpose: This study was conducted to investigate the safety of dental imaging in pregnant women with respect to fetal health. Materials and Methods: Searches were conducted of the PubMed, Scopus, and Web of Science databases in May 2023. The inclusion criteria encompassed cross-sectional and longitudinal studies that focused on the analysis of diagnostic dental imaging in pregnant women, as well as studies utilizing phantoms to simulate imaging examinations. The exclusion criteria consisted of reviews, letters to the editor, book chapters, and abstracts from scientific conferences and seminars. Results: A total of 3,913 articles were identified. Based on a review of the titles and abstracts, 3,892 articles were excluded, leaving 21 articles remaining for full-text review. Of these, 18 were excluded, and 4 additional articles were included as cross-references. Ultimately, 7 articles underwent quantitative-qualitative analysis. Three retrospective studies were focused on pregnant women who underwent dental imaging procedures. The remaining 4 studies utilized female phantoms to simulate imaging examinations and represent the radiation doses absorbed by the uterus or thyroid. Conclusion: Few dental radiology studies have been conducted to determine the safe radiation threshold for pregnant women. Additionally, the reviewed articles did not provide numbers of dental examinations, by type, corresponding to this dose. Dental imaging examinations of pregnant women should not be restricted if clinically indicated. Ultimately, practitioners must be able to justify the examination and should adhere to the "as low as diagnostically acceptable, being indication-oriented and patient-specific" (ALADAIP) principle of radioprotection.

Theoretical Investigation of the Triphosphate Forms of Azidothymidine and Thymidine

  • Arissawa, Marcia;Felcman, Judith;Herrera, Juan Omar Machucca
    • BMB Reports
    • /
    • v.36 no.3
    • /
    • pp.243-250
    • /
    • 2003
  • In this paper we investigate (using AM1 semi-empirical as well as HF methods at the STO-3G, 3-21G, 6-31G, 6-$31G^*$ and 6-31+$G^{**}$ level) the conformations, geometrical parameters, Mulliken charges, and solvation effects of the triphosphate form of AZT (AZTTP), as well as the thymidine nucleotide (dTTP) structure. Our calculated geometrical parameters and Mulliken charges, with and without solvation effects, are correlated with recent experimental results.