• 제목/요약/키워드: RHS-column

검색결과 16건 처리시간 0.02초

각형강관 기둥을 가진 철골모멘트 접합부의 변형능력 (Deformation Capacity of Steel Moment Connections with RHS Column)

  • 김영주;오상훈;유홍식
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.249-258
    • /
    • 2006
  • In this paper, deformation capacity of steel moment connections with RHS column was investigated. Initially, non-linear finite element analysis of five bate steel beam models was conducted. The models were designed to have different detail at their beam-to-column connection, so that the flexural moment capacity was different respectively. Analysis results showed 4hat the moment transfer efficiency of the analytical model with RHS-column was poor when comparing to model with WF(Wide flnage)-column due to out-of-plane deformation of the RHS-column flange. The presence of scallop and thin plate of RHS column was also a reason of the decrease of moment transfer efficiency, which would result in a potential fracture of tile steel beam-to-column connections. Further test on beam-to-column connections with RHS column revealed that the moment transfer efficiency of a beam web decreased due to the out-of-plane deformation of column flange, which led to premature failure of the connection.

  • PDF

Characterization of the main component of equal width welded I-beam-to-RHS-column connections

  • Lopez-Colina, Carlos;Serrano, Miguel A.;Lozano, Miguel;Gayarre, Fernando L.;Suarez, Jesus M.;Wilkinson, Tim
    • Steel and Composite Structures
    • /
    • 제32권3호
    • /
    • pp.337-346
    • /
    • 2019
  • The present paper tries to contribute fill the gap of application of the component method to tubular connections. For this purpose, one typical joint configuration in which just one component can be considered as active has been studied. These joints were selected as symmetrically loaded welded connections in which the beam width was the same as the column width. This focused the study on the component 'side walls of rectangular hollow sections (RHS) in tension/compression'. It should be one of the main components to be considered in welded unstiffened joints between I beams and RHS columns. Many experimental tests on double-sided I-beam-to-RHS-column joint with a width ratio 1 have been carried out by the authors and a finite element (FE) model was validated with their results. Then, some different analytical approaches for the component stiffness and strength have been assessed. Finally, the stiffness proposals have been compared with some FE simulations on I-beam-to-RHS-column joints. This work finally proposes the most adequate equations that were found for the stiffness and strength characterization of the component 'side walls of RHS in tension/compression' to be applied in a further unified global proposal for the application of the component method to RHS.

Experimental study on partially-reinforced steel RHS compression members

  • Pinarbasi, Seval
    • Structural Engineering and Mechanics
    • /
    • 제63권3호
    • /
    • pp.385-400
    • /
    • 2017
  • This paper presents an experimental study on the behavior of axially-loaded steel RHS (rectangular hollow section) compression members that are partially reinforced along their lengths with welded steel plates. 28 slender column tests were carried out to investigate the effects of the slenderness ratio of the unreinforced member and the ratio of the reinforced length of the member to its entire length. In addition to the slender column tests, 14 stub-column tests were conducted to determine the basic mechanical properties of the test specimens under uniform compression. Test results show that both the compressive strength and stiffness of an RHS member can be increased significantly compared to its unreinforced counterpart even when only the central quarter of the member is reinforced. Based on the limited test data, it can be concluded that partial reinforcement is, in general, more effective in members with larger slenderness ratios. A simple design expression is also proposed to predict the compressive strength of RHS columns partially reinforced along their length with welded steel plates by modifying the provisions of AISC 360-10 to account for the partial reinforcement.

Effects of RHS face deformation on the rigidity of beam-column connection

  • Hadianfard, M.A.;Rahnema, H.
    • Steel and Composite Structures
    • /
    • 제10권6호
    • /
    • pp.489-500
    • /
    • 2010
  • The rigid connections of I-beams to Rectangular Hollow Sections (RHS) in steel structures usually behave as semi-rigid connection. This behavior is directly related to the column face deformation. The deformation in the wall of RHS column in the connection zone causes a relative rotation between beam end and column axis, which consequently reduces the rigidity of beam-column connection. In the present paper, the percentages of connection rigidity reduction for serviceability conditions are evaluated by using the finite element analysis. Such percentages for RHS columns without internal stiffeners are considerable, and can be calculated from presented graphs.

Rotation capacity of composite beam connected to RHS column, experimental test results

  • Eslami, Mohammadreza;Namba, Hisashi
    • Steel and Composite Structures
    • /
    • 제22권1호
    • /
    • pp.141-159
    • /
    • 2016
  • Commonly in steel frames, steel beam and concrete slab are connected together by shear keys to work as a unit member which is called composite beam. When a composite beam is subjected to positive bending, flexural strength and stiffness of the beam can be increased due to "composite action". At the same time despite these advantages, composite action increases the strain at the beam bottom flange and it might affect beam plastic rotation capacity. This paper presents results of study on the rotation capacity of composite beam connected to Rectangular Hollow Section (RHS) column in the steel moment resisting frame buildings. Due to out-of-plane deformation of column flange, moment transfer efficiency of web connection is reduced and this results in reduction of beam plastic rotation capacity. In order to investigate the effects of width-to-thickness ratio (B/t) of RHS column on the rotation capacity of composite beam, cyclic loading tests were conducted on three full scale beam-to-column subassemblies. Detailed study on the different steel beam damages and concrete slab damages are presented. Experimental data showed the importance of this parameter of RHS column on the seismic behavior of composite beams. It is found that occurrence of severe concrete bearing crush at the face of RHS column of specimen with smaller width-to-thickness ratio resulted in considerable reduction on the rate of strain increase in the bottom flange. This behavior resulted in considerable improvement of rotation capacity of this specimen compared with composite and even bare steel beam connected to the RHS column with larger width-to-thickness ratio.

RHS기둥-보 접합부의 모멘트전달효율 평가 (Evaluation of Moment Transfer Efficiency of a Beam Web at RHS Column-to-Beam Connections)

  • 김영주;오상훈
    • 한국지진공학회논문집
    • /
    • 제10권4호
    • /
    • pp.67-76
    • /
    • 2006
  • 본 논문에서는 철골 각형강관단면(RHS) 기둥-보 접합부에서 웨브의 모멘트 전달효율을 평가하였다. 먼저, 5개의 철골보접합부에 대한 비선형 유한요소해석을 수행하였다. 이들은 접합부 상세가 다르게 설계되었고, 따라서 휨저항 성능이 각기 다르다. 해석결과 RHS 기둥을 가진 모델은 기둥 플랜지의 면외변형 때문에 WF(Wide Flange) 기둥을 가진 모델에 비해 모멘트 전달효율이 저하함을 보였다. 스캘럽(WAH)과 얇은 강관기둥 두께도 모멘트 전달효율의 저하를 가져오는 원인으로서, 결과적으로 보-기둥 접합부의 파단을 초래할 가능성이 크다. 해석과 이전의 실험결과를 기초로 하면, 응력집중은 모멘트 전달효율과 반비례하고, 접합부의 변형능력은 모멘트 전달효율의 저하에 따라 감소하는 것을 알 수 있다. 더 나아가서 바닥슬래브가 있는 합성보 접합부에 대한 유한요소해석결과는 중립축이 상부플랜지 방향으로 상승함으로써 모멘트 전달효율이 저하했고, 이러한 영향은 접합부의 조기 취성파단을 초래하는 것을 보였다.

Stiffness model for "column face in bending" component in tensile zone of bolted joints to SHS/RHS column

  • Ye, Dongchen;Ke, Ke;Chen, Yiyi
    • Steel and Composite Structures
    • /
    • 제38권6호
    • /
    • pp.637-656
    • /
    • 2021
  • The component-based method is widely used to analyze the initial stiffness of joint in steel structures. In this study, an analytical component model for determining the column face stiffness of square or rectangular hollow section (SHS/RHS) subjected to tension was established, focusing on endplate connections. Equations for calculating the stiffness of the SHS/RHS column face in bending were derived through regression analysis using numerical results obtained from a finite element model database. Because the presence of bolt holes decreased the bending stiffness of the column face, this effect was calculated using a novel plate-spring-based model through numerical analysis. The developed component model was first applied to predict the bending stiffness of the SHS column face determined through tests. Furthermore, this model was incorporated into the component-based method with other effective components, e.g., bolts under tension, to determine the tensile stiffness of the T-stub connections, which connects the SHS column, and the initial rotational stiffness of the joints. A comparison between the model predictions, test data, and numerical results confirms that the proposed model shows satisfactory accuracy in evaluating the bending stiffness of SHS column faces.

교체 가능한 강재 헌치 시스템으로 보강한 철근 콘크리트 보-기둥 구조물의 내진성능에 관한 실험적 연구 (An Experimental Study on Seismic Performance of Reinforced Concrete Beam-Column Retrofitted with Replaceable Steel Haunch System)

  • 김윤성;김민숙;이영학
    • 한국공간구조학회논문집
    • /
    • 제24권1호
    • /
    • pp.81-88
    • /
    • 2024
  • The purpose of this study is to experimentally analyze the seismic performance of beam-column specimens with vertical irregular, which were reinforced with RHS (Replaceable steel haunch system). a steel haunch system. To evaluate the seismic performance of the RHS, three specimens were manufactured and subjected to cycle loading tests. Retrofitted specimens have different beam-upper column stiffness ratio as a variable. The stiffness ratio of beam-upper column were considered to be 1.2 and 0.84. As a result of the test, the specimen reinforced with RHS showed improved maximum load and effective stiffness, and energy dissipation capacity compared to the non-retrofitted specimen with same beam-upper column stiffness ratio. The specimen with 0.84 beam-upper column stiffness ratio showed improved performance than the specimen with 12.

철골모멘트접합부의 내진보강에 관한 해석적 연구 (Analytical Study for Seismic Retrofit of SMRFs Connections)

  • 오상훈;김영주
    • 한국강구조학회 논문집
    • /
    • 제20권3호
    • /
    • pp.445-454
    • /
    • 2008
  • 철골모멘트접합부에 관한 이전의 연구에 의하면 RHS 기둥과 기존의 스캘럽을 가진 접합부실험체의 변형능력은 매우 열등했고, 보단부의 응력집중은 보에서 기둥으로 전달되는 모멘트의 전달효율에 영향을 받는다는 사실을 실험이나 해석적으로 밝혔다. 본 연구는 보강된 RBS 접합부와 용접수평스티프너를 사용한 효고현남부지진 이전에 지어진 모멘트 접합부를 내진보강하는데 주안점을 두었다. 이러한 내진보강은 시공성과 경제성을 고려하여 보의 하부플랜지에만 실시하였다. 접합부의 내진보강방법을 발견하고 이를 향상시키기 위해서 비선형유한요소해석을 통해서 다양한 변수를 바탕으로 한 파라메타 연구를 실시하였다.

RHS 기둥-H형강보 접합부의 내진보강 설계 (Seismic Retrofit Design of RHS Column-to-H Beam Connections)

  • 김영주;오상훈
    • 한국강구조학회 논문집
    • /
    • 제20권4호
    • /
    • pp.529-537
    • /
    • 2008
  • 본 논문의 목적은 슬래브가 있는 RHS 기둥-H 형강보 접합부의 내진보강설계방법을 제안하는 것이다. 모멘트접합부의 내진보강에 관한 이전 연구를 참조하면, 보강된 RBS(SR) 또는 연장된 수평스티프너(LH)를 가진 접합부는 응력/변형도 집중의 저감에 매우 효과적인 것으로 밝혀졌다. 따라서 두개의 내진보강방법, 즉, 보강된 RBS(SR)과 연장된 수평스티프너(LH)를 사용한 새로운 설계절차를 제시하였다: 게다가 본 논문에는 접합부의 내진보강방법을 향상시키기 위한 다양한 상세 및 방법 등이 기술되었다. 끝으로 설계방법의 검증을 위해서 파일럿테스트를 실시하였다.