• Title/Summary/Keyword: RF-SET

Search Result 203, Processing Time 0.021 seconds

Simulation Method for Radio-Frequency Single-Electron Transistor (RF-SET) Operation (고주파 단일전자 트랜지스터 (RF-SET) 동작의 시뮬레이션 방법)

  • Yu Yun Seop;Park Hyun-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.5 s.335
    • /
    • pp.9-14
    • /
    • 2005
  • Simulation method for a pure radio-frequency (rf) mode of reflection-type and a pure rf mode of transmission-type radio-frequency single-electron transistor (RF-SET) operation is introduced. In this method, the solutions of differential equations based on Kirchhoff's law are obtained self-consistently at frequency-domain. Also, the steady-sate single-electron transistor (SET) current model and the time-dependent SET current model are used in this method. The reflected wave of a typical reflection-type RF-SET and the transmitted wave of a typical transmission-type RF-SET are calculated, and the accuracy of our developed method including the steady-state SET current model is verified with the method introduced by reference 2. At high frequency over GHz, results of our developed method including the time-dependent SET current model are considerably different from that including the steady-state SET current model. At high frequency over GHz, an exact time-dependent SET current model is needed to analyze RF-SET operation.

DESCRIPTION ON THE CONSTITUTION OF RF TEST SET FOR SOC 13M ANTENNA

  • Park, Durk-Jong;Yang, Hyung-Mo;Ahn, Sang-Il
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.208-211
    • /
    • 2006
  • The contents of RF test set which can be used for checking the function and performance of 13m antenna installed in KARI site are described in this paper. For the purpose of considering RF test set as the transceiver in COMS, it is designed to retransmit the LRIT and HRIT in L-Band after receiving them in S-Band from 13m antenna. Additionally, this set has a function to turnaround raging tone used for the measurement of distance between satellite and 13m antenna. The required all equipments of RF test set are summarized with configuration. Measurements of several equipments which have already been delivered are described in this paper. The assembled RF test set will be used for the verification of 13m antenna

  • PDF

Predicting the CPT-based pile set-up parameters using HHO-RF and PSO-RF hybrid models

  • Yun Dawei;Zheng Bing;Gu Bingbing;Gao Xibo;Behnaz Razzaghzadeh
    • Structural Engineering and Mechanics
    • /
    • v.86 no.5
    • /
    • pp.673-686
    • /
    • 2023
  • Determining the properties of pile from cone penetration test (CPT) is costly, and need several in-situ tests. At the present study, two novel hybrid learning models, namely PSO-RF and HHO-RF, which are an amalgamation of random forest (RF) with particle swarm optimization (PSO) and Harris hawks optimization (HHO) were developed and applied to predict the pile set-up parameter "A" from CPT for the design aim of the projects. To forecast the "A," CPT data along were collected from different sites in Louisiana, where the selected variables as input were plasticity index (PI), undrained shear strength (Su), and over consolidation ratio (OCR). Results show that both PSO-RF and HHO-RF models have acceptable performance in predicting the set-up parameter "A," with R2 larger than 0.9094, representing the admissible correlation between observed and predicted values. HHO-RF has better proficiency than the PSO-RF model, with R2 and RMSE equal to 0.9328 and 0.0292 for the training phase and 0.9729 and 0.024 for testing data, respectively. Moreover, PI and OBJ indices are considered, in which the HHO-RF model has lower results which leads to outperforming this hybrid algorithm with respect to PSO-RF for predicting the pile set-up parameter "A," consequently being specified as the proposed model. Therefore, the results demonstrate the ability of the HHO algorithm in determining the optimal value of RF hyperparameters than PSO.

The Status of the High Enthalpy Plasma Test Facility in Chonbuk National University (전북대 고온플라즈마 설비 구축현황)

  • Choi, Seong-Man;Shin, Eui-Sup;Suh, Young-Sug;Seo, Jun-Ho;Hong, Bong-Geun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.417-420
    • /
    • 2010
  • The high enthalpy plasma research center in Chonbuk national university is under construction with the support of the ministry of the education, science and technology as a fundamental research project The project periods are five year and started at July, 1, 2009. The total project budget is about 39,300 million Won. Four types of plasma equipment will be installed in this research center during the project periods. The equipments are 1 set of 0.4 MW class enhanced Huels type plasma equipment, 1 set of 2.4MW class enhanced Huels type plasma equipment, 1 set of 60Kw RF plasma equipment and 1s set of 200 kW RF plasma equipment.

  • PDF

Development Status of High Enthalpy Plasma Equipment (전북대 고온플라즈마 설비 구축 및 응용연구 소개)

  • Choi, Chea-Hong;Lee, Mi-Yun;Kim, Min-Ho;Hong, Bong-Guen;Seo, Jun-Ho
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.694-696
    • /
    • 2011
  • The high enthalpy plasma research center in Chonbuk national university is under construction for four types of plasma equipments. The equipments are 1set of 0.4 MW class enhanced Huels type plasma equipment, 1 set of 2.4 MW class enhanced Huels type plasma quipment, 1 set of 60 kW RF plasma equipment and 1 set of 200 kW RF plasma equipment. 60kW RF plasma system is R&D and pilot scale production equipment of nano powder synthesis and plasma spray coating. 200kW RF plasma system is mass production equipment with high power capacity of nano powder synthesis. 0.4MW plasma system can be applied to the ground test facility for material testing under re-entry conditions for space vehicles.

  • PDF

Utilizing the GOA-RF hybrid model, predicting the CPT-based pile set-up parameters

  • Zhao, Zhilong;Chen, Simin;Zhang, Dengke;Peng, Bin;Li, Xuyang;Zheng, Qian
    • Geomechanics and Engineering
    • /
    • v.31 no.1
    • /
    • pp.113-127
    • /
    • 2022
  • The undrained shear strength of soil is considered one of the engineering parameters of utmost significance in geotechnical design methods. In-situ experiments like cone penetration tests (CPT) have been used in the last several years to estimate the undrained shear strength depending on the characteristics of the soil. Nevertheless, the majority of these techniques rely on correlation presumptions, which may lead to uneven accuracy. This research's general aim is to extend a new united soft computing model, which is a combination of random forest (RF) with grasshopper optimization algorithm (GOA) to the pile set-up parameters' better approximation from CPT, based on two different types of data as inputs. Data type 1 contains pile parameters, and data type 2 consists of soil properties. The contribution of this article is that hybrid GOA - RF for the first time, was suggested to forecast the pile set-up parameter from CPT. In order to do this, CPT data and related bore log data were gathered from 70 various locations across Louisiana. With an R2 greater than 0.9098, which denotes the permissible relationship between measured and anticipated values, the results demonstrated that both models perform well in forecasting the set-up parameter. It is comprehensible that, in the training and testing step, the model with data type 2 has finer capability than the model using data type 1, with R2 and RMSE are 0.9272 and 0.0305 for the training step and 0.9182 and 0.0415 for the testing step. All in all, the models' results depict that the A parameter could be forecasted with adequate precision from the CPT data with the usage of hybrid GOA - RF models. However, the RF model with soil features as input parameters results in a finer commentary of pile set-up parameters.

Site Plan of High-enthalpy Plasma Research Center in Chonbuk National University (전북대학교 고온플라즈마응용연구센터 Site Plan)

  • Kim, Min-Ho;Choi, Seong-Man;Seo, Jun-Ho;Choi, Chea-Hong;Hong, Bong-Guen
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.764-767
    • /
    • 2010
  • The high enthalpy plasma research center in Chonbuk national university is under construction for MW class plasma wind tunnel. Four types of plasma equipment will be installed in the research center. The equipments are 1set of 0.4 MW class enhanced Huels type plasma equipment, 1 set of 2.4 MW class enhanced Huels type plasma equipment, 1 set of 60 kW RF plasma equipment and 1 set of 200 kW RF plasma equipment. And electrical, water and gas utilities to assistant plasma equipments are under construction. The research center consists of experiment building, research building, power supply building, air supply building, cooling tower foundation.

  • PDF

Design of Radio Frequency Test Set for TC&R RF Subsystem Verification of LEO and GEO Satellites (저궤도 및 정지궤도위성의 TC&R RF 서브시스템 검증을 위한 RF 시험 장비 설계)

  • Cho, Seung-Won;Lee, Sang-Jeong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.8
    • /
    • pp.674-682
    • /
    • 2014
  • Radio Frequency Test Set (RFTS) is essential to verify Telemetry, Command & Ranging (TC&R) RF subsystem of both Low Earth Orbit (LEO) and Geostationary Earth Orbit (GEO) satellite during Assembly Integration & Test (AI&T). The existing RFTS was specialized for each project and needed to be modified for each new satellite. The new design enables RFTS to be used in various projects. The hardware and software was designed considering this and therefore it could be directly used in other projects within a similar test period without modification or inconvenience. It will be also easily controlled, modified, and managed through the extension in modularization according to each function and the use of COTS (commercial on-the-self) and this will improve system reliability. A more reliable RF test measurement is also provided in this new RFTS by using an accurate reference clock signal.

Design and Evaluation of Higher Level Modulation in Beam Space MIMO Communication System (빔 공간 MIMO 통신시스템에서 고레벨 변조 설계와 평가)

  • Kim, Bong-Jun;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.5
    • /
    • pp.220-228
    • /
    • 2014
  • ESPAR(Electronically Steerable Parasitic Array Radiator) antenna is the technique for overcoming the problems of space limitation and energy efficiency due to the multiple RF-chain. Conventional MIMO system with multiple antenna requires a large number of RF-chain for transmitting the multiple data because it transmits the data in proportion to the number of antenna. Beamspace MIMO system using the ESPAR antenna which has single RF-chain was proposed for solving the problems caused by using the multiple antenna and RF-chain. In this paper, therefore we propose 2x2 beamspace MIMO system using the 16, 64-QAM modulation and evaluate the performance of this system to reveal that it is possible that beamspace MIMO system can use not only PSK modulation but also QAM modulation. We confirm that QAM symbol can be generated by adjusting reactance of parasitic elements and making reactance set and also we confirm that performance of beamspace MIMO system is similar to the conventional MIMO system by transmitting the QAM symbol made by reactance set through the simulation.

Conceptual design of electrical, water and gas utilities for MW class plasma wind tunnel in CBNU (전북대학교 MW급 플라즈마 풍동용 공통지원설비 개념설계)

  • Choi, Chea-Hong;Seo, Jun-Ho;Hong, Bong-Guen;Choi, Seong-Man
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.784-785
    • /
    • 2010
  • The high enthalpy plasma research center in Chonbuk national university is under construction for MW class plasma wind tunnel. Four types of plasma equipment will be installed in the research center. The equipments are 1set of 0.4 MW class enhanced Huels type plasma equipment, 1 set of 2.4 MW class enhanced Huels type plasma quipment, 1 set of 60 kW RF plasma equipment and 1 set of 200 kW RF plasma equipment. And electrical, water and gas utilities to assistant plasma equipments are under construction.

  • PDF