• Title/Summary/Keyword: RF test

Search Result 695, Processing Time 0.025 seconds

The Effect of Forward Walking and Backward Walking on Quadriceps Muscles with Treadmill Inclination: Surface Electromyographic Analysis (경사진 트레드밀에서 전방 걷기와 후방걷기 동안 넙다리네갈래근 활동성 비교: 표면 근전도 분석)

  • Han, Sang-Wan
    • Physical Therapy Korea
    • /
    • v.12 no.1
    • /
    • pp.63-70
    • /
    • 2005
  • To compare the effects of forward walking and backward walking on surface electromyographic analysis of quadriceps muscles at treadmill grades of 0%, 5% and 10%, subjects were randomized to eleven athletics (5 females, 6 males), with a mean age of 17.8 years, and a SD of 4.66 years. The values of the surface electromyographic (SEMG) activity of the rectus femoris (RF), vastus lateralis (VL) and vastus medialis oblique (VMO) were measured during forward walking and backward walking on a treadmill at grades of 0, 5 and 10%. The subjects walked for approximately 10 seconds at 4.0 km/h. The data were analyzed by repeated measuring of the two-way ANOVA and analyzed by a paired t-test between forward walking and backward walking. The SEMG activity levels of the RF, VL and VMO were the highest when both the forward walking and backward walking increased incrementally for treadmill grades of 0% to 10%, but the VMO/VL ratio had no significant changes. The SEMG activity levels of the RF, VL and VMO were significantly different between directions. However, SEMG activity levels of the RF, VL, VMO and VMO/VL ratio did not show significant difference among the treadmill grades. No statistically significant interactions were detected between the direction of walking and treadmill grade. Backward walking on the treadmill at 4 km/h and grades of 0%, 5%, 10% elicited a greater SEMG activity on the quadriceps muscles than did forward walking under the same conditions. The results suggest that the quadriceps may be effectively activated by performance at treadmill grades of 10%. This investigation confirms that backward walking up an incline may place additional muscular demands on individuals.

  • PDF

A Comparison of Lower Limb Muscle Activity Affecting Sit-to-Stand Movement of Stroke Patients (뇌졸중 환자의 앉은 자세에서 일어서기 동작 수행에 영향을 주는 다리 근 활성 비교)

  • Park, In-Seok;Ju, Sung-Kwang
    • PNF and Movement
    • /
    • v.16 no.1
    • /
    • pp.59-66
    • /
    • 2018
  • Purpose: This study aimed (1) to identify asymmetry observed in electromyography (EMG) activity patterns of lower limb muscles between affected and unaffected sides of stroke patients during sit to stand (STS) movement and (2) to identify the muscles of the paretic lower limb that affected STS performance in stroke patients. Methods: This study consisted of 27 patients (15 males and 12 females) with poststroke hemiparesis. The activation of the rectus femoris (RF), tibialis anterior (TA), and gastrocnemius (GCM) of the affected side and unaffected side during STS movement were recorded using surface EMG. In addition, EMG lower limb muscle activation patterns were measured in the all section, pre-thigh off (pre-TO), and post-thigh off (post-TO) section. All measurements were obtained during five repetitions of the STS (FTSTS) movement. An independent t-test was performed to compare the affected side and unaffected side of the lower limb during the STS movement. A stepwise linear regression analysis was conducted to identify the muscles that affected STS performance. Results: Activation of both the RF and TA significantly affected the lower limb during the STS movement (p<0.05). Two muscles showed a difference on the post-TO section. The results of the stepwise multiple regression analysis showed that the RF and TA muscles of the affected lower limb were affected in FTSTS. Conclusion: These results provide a basis for reinforcement training, focusing on the RF and TA muscles of the affected side of stroke patients to improve asymmetric movement and performance in STS movement.

The Effects of Foot Position on Electromyographic Activity of Knee Extensors in Standing (기립자세에서 발위치가 무릎 폄근의 등척성수축 근전도 활성도에 미치는 영향)

  • Kim, Seng-Jung;Kwon, Oh-Yun;Cho, Sang-Hyun;Hwang, Ji-Hye
    • Physical Therapy Korea
    • /
    • v.8 no.2
    • /
    • pp.1-16
    • /
    • 2001
  • This study was designed to identify the effects of foot position on electromyographic (EMG) activity of the quadriceps femoris during maximum voluntary contraction (MVC) in standing. Twenty young adults who had not experienced any knee injuries were recruited. Their Q-angles were within a normal range. They were asked to stand in five different foot positions ($40^{\circ}$ externally rotated, $30^{\circ}$ internally rotated, neutral, $20^{\circ}$ plantarflexed, and $10^{\circ}$ dorsiflexed foot position). The EMG activities of the vastus lateralis (VL), rectus femoris (RF), and vastus medialis oblique (VMO) were recorded in standing by surface electrodes and normalized by MVC EMG values derived from manual muscle test. The normalized EMG activity levels (%MVC EMG) of muscles in the five foot positions were compared using repeated measures ANOVA. The EMG activity levels of the VL, RF, and VMO were the highest when foot was externally rotated. The EMG activity levels of the VL and RF were significantly different among the foot positions (p<.05). However, EMG activity levels of the VL, RF, VMO, and VMO/VL ratio did not show significant differences in each foot position (p> .05). The results suggest that the quadriceps femoris may be effectively activated by performing MVC at an externally rotated foot position. Therefore, the externally rotated foot position can be considered as an effective foot position for quadriceps femoris strengthening exercise. Further studies are needed to identify whether there are differences in the effects of foot position on muscle strength after MVC exercise of quadriceps femoris in standing.

  • PDF

Linear Tapered Slot Rectifying Antenna for Portable UHF-Band RFID System (휴대용 UHF대역 RFID 시스템을 위한 선형 테이퍼드 슬롯 정류 안테나)

  • Pyo, Seongmin
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.368-371
    • /
    • 2020
  • In this paper, we propose a linear tapered slot rectifying antenna for a portable UHF-band RFID system. Since the proposed rectifying antenna does not use a dielectric substrate, the planar antenna is implemented with a thin metal thickness. The rectifier circuit converts input RF power into output DC voltage using a voltage doubler circuit based on two anti-parallel schottky diodes. The rectifying antenna is integrated by the voltage doubler circuit into a linear tapered slot antenna. For conjugate impedance matching of the rectifying circuit and the linear tapered slot antenna, the source-pull method was utilized by adjusting the angle of the tapered slot and the length of the antenna feed line. The proposed antenna prototype has been verified with the electrical and radiation characteristics through RF-DC conversion and far-field radiation test in open space measurement environment. Finally, the proposed antenna is realized to 0.23-wavelength (75 mm) and 0.18-wavelength (60 mm) at 915 MHz center frequency.

Wideband Signal Generator Implementation for Earth Observation Satellite (지구관측위성 광대역 신호 발생기 구현)

  • Kim, Joong-Pyo;Ryu, Sang-Burm;Lim, Won-Gyu;Lee, Sang-Kon
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.2
    • /
    • pp.88-93
    • /
    • 2013
  • The wideband chirp signal generator to enhance the resolution of synthetic aperture radar of obtaining the earth observation image is needed. This paper deals with designing, manufacturing and testing the wideband digital chirp signal generator having high resolution for LEO earth observation satellite. The wideband digital chirp signal generator is implemented with the memory-map based structure which is mostly applied in the satellite, and consists of the digital module to generate the digital chirp signal and the RF module to perform the quadrature modulation. The I/Q signals stored in the memory of the digital module are D/A converted and delivered to be quadrature modulated with the reference signal of 1275 MHz in the RF module. Furthermore, the test bench and GUI to validate the signal generator function are also developed. It is found that the requirement of 144 MHz bandwidth for the digital chirp signal generator is well met. Finally it is noteworthy that the distortion occurred in the chirp signal generator was compensated by the pre-distortion compensation.

Metal Oxide Multi-Layer Color Glass by Radio Frequency Magnetron Sputtering for Building Integrated Photovoltaic System (RF Magnetron 스퍼터링 공정을 이용한 BIPV용 산화 금속 다중층 컬러 유리 구현 기술 연구)

  • Gasonoo, Akpeko;Ahn, Hyeon-Sik;Kim, Min-Hoi;Lee, Jae-Hyun;Choi, Yoon-seuk
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.1056-1061
    • /
    • 2018
  • In this study, we propose the structure of color glass for BIPV (Building Integrated Photovoltaic System) and develop process technology to realize it. It was verified through computer simulation based on wave optics that two different kinds of metal oxide thin films with different refractive indices could be integrated to realize different colors with good transmittance. To fabricate the structure, we used RF Magnetron deposition method to achieve the target thickness uniformly. The optical analysis of the samples was carried our by comparing with the results of computer simulations and it was found that this technique can be stably implemented on lab scale. The stability test over weeks was confirmed at room temperature. This method is expected to be very useful in BIPV buildings.

Predicting the mortality of pneumonia patients visiting the emergency department through machine learning (기계학습모델을 통한 응급실 폐렴환자의 사망예측 모델과 기존 예측 모델의 비교)

  • Bae, Yeol;Moon, Hyung Ki;Kim, Soo Hyun
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.5
    • /
    • pp.455-464
    • /
    • 2018
  • Objective: Machine learning is not yet widely used in the medical field. Therefore, this study was conducted to compare the performance of preexisting severity prediction models and machine learning based models (random forest [RF], gradient boosting [GB]) for mortality prediction in pneumonia patients. Methods: We retrospectively collected data from patients who visited the emergency department of a tertiary training hospital in Seoul, Korea from January to March of 2015. The Pneumonia Severity Index (PSI) and Sequential Organ Failure Assessment (SOFA) scores were calculated for both groups and the area under the curve (AUC) for mortality prediction was computed. For the RF and GB models, data were divided into a test set and a validation set by the random split method. The training set was learned in RF and GB models and the AUC was obtained from the validation set. The mean AUC was compared with the other two AUCs. Results: Of the 536 investigated patients, 395 were enrolled and 41 of them died. The AUC values of PSI and SOFA scores were 0.799 (0.737-0.862) and 0.865 (0.811-0.918), respectively. The mean AUC values obtained by the RF and GB models were 0.928 (0.899-0.957) and 0.919 (0.886-0.952), respectively. There were significant differences between preexisting severity prediction models and machine learning based models (P<0.001). Conclusion: Classification through machine learning may help predict the mortality of pneumonia patients visiting the emergency department.

Development of a distributed high-speed data acquisition and monitoring system based on a special data packet format for HUST RF negative ion source

  • Li, Dong;Yin, Ling;Wang, Sai;Zuo, Chen;Chen, Dezhi
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3587-3594
    • /
    • 2022
  • A distributed high-speed data acquisition and monitoring system for the RF negative ion source at Huazhong University of Science and Technology (HUST) is developed, which consists of data acquisition, data forwarding and data processing. Firstly, the data acquisition modules sample physical signals at high speed and upload the sampling data with corresponding absolute-time labels over UDP, which builds the time correlation among different signals. And a special data packet format is proposed for the data upload, which is convenient for packing or parsing a fixed-length packet, especially when the span of the time labels in a packet crosses an absolute second. The data forwarding modules then receive the UDP messages and distribute their data packets to the real-time display module and the data storage modules by PUB/SUB-pattern message queue of ZeroMQ. As for the data storage, a scheme combining the file server and MySQL database is adopted to increase the storage rate and facilitate the data query. The test results show that the loss rate of the data packets is within the range of 0-5% and the storage rate is higher than 20 Mbps, both acceptable for the HUST RF negative ion source.

Comparison of Feature Selection Methods Applied on Risk Prediction for Hypertension (고혈압 위험 예측에 적용된 특징 선택 방법의 비교)

  • Khongorzul, Dashdondov;Kim, Mi-Hye
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.11 no.3
    • /
    • pp.107-114
    • /
    • 2022
  • In this paper, we have enhanced the risk prediction of hypertension using the feature selection method in the Korean National Health and Nutrition Examination Survey (KNHANES) database of the Korea Centers for Disease Control and Prevention. The study identified various risk factors correlated with chronic hypertension. The paper is divided into three parts. Initially, the data preprocessing step of removes missing values, and performed z-transformation. The following is the feature selection (FS) step that used a factor analysis (FA) based on the feature selection method in the dataset, and feature importance (FI) and multicollinearity analysis (MC) were compared based on FS. Finally, in the predictive analysis stage, it was applied to detect and predict the risk of hypertension. In this study, we compare the accuracy, f-score, area under the ROC curve (AUC), and mean standard error (MSE) for each model of classification. As a result of the test, the proposed MC-FA-RF model achieved the highest accuracy of 80.12%, MSE of 0.106, f-score of 83.49%, and AUC of 85.96%, respectively. These results demonstrate that the proposed MC-FA-RF method for hypertension risk predictions is outperformed other methods.

Creation of regression analysis for estimation of carbon fiber reinforced polymer-steel bond strength

  • Xiaomei Sun;Xiaolei Dong;Weiling Teng;Lili Wang;Ebrahim Hassankhani
    • Steel and Composite Structures
    • /
    • v.51 no.5
    • /
    • pp.509-527
    • /
    • 2024
  • Bonding carbon fiber-reinforced polymer (CFRP) laminates have been extensively employed in the restoration of steel constructions. In addition to the mechanical properties of the CFRP, the bond strength (PU) between the CFRP and steel is often important in the eventual strengthened performance. Nonetheless, the bond behavior of the CFRP-steel (CS) interface is exceedingly complicated, with multiple failure causes, giving the PU challenging to forecast, and the CFRP-enhanced steel structure is unsteady. In just this case, appropriate methods were established by hybridized Random Forests (RF) and support vector regression (SVR) approaches on assembled CS single-shear experiment data to foresee the PU of CS, in which a recently established optimization algorithm named Aquila optimizer (AO) was used to tune the RF and SVR hyperparameters. In summary, the practical novelty of the article lies in its development of a reliable and efficient method for predicting bond strength at the CS interface, which has significant implications for structural rehabilitation, design optimization, risk mitigation, cost savings, and decision support in engineering practice. Moreover, the Fourier Amplitude Sensitivity Test was performed to depict each parameter's impact on the target. The order of parameter importance was tc> Lc > EA > tA > Ec > bc > fc > fA from largest to smallest by 0.9345 > 0.8562 > 0.79354 > 0.7289 > 0.6531 > 0.5718 > 0.4307 > 0.3657. In three training, testing, and all data phases, the superiority of AO - RF with respect to AO - SVR and MARS was obvious. In the training stage, the values of R2 and VAF were slightly similar with a tiny superiority of AO - RF compared to AO - SVR with R2 equal to 0.9977 and VAF equal to 99.772, but large differences with results of MARS.