• Title/Summary/Keyword: RF characteristics test

Search Result 105, Processing Time 0.026 seconds

Design and Parametric Study on Discone Antenna for Broadband RF Test Chamber

  • Oh, Soon-Soo;Kim, In-Ryeol;Choi, Dong-Geun;Park, Wook-Ki
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.6
    • /
    • pp.534-538
    • /
    • 2016
  • This paper discusses the characteristics and effects of dielectric inner-supports on discone antenna for broadband RF test chamber, and the verification has been performed by simulation. Several design parameters such as the thickness of the gap support, the position of the side support, and the thickness of the side support has been analyzed. The thickness of the gap support affected the reflection coefficient. An effect of the offset of the side support from the center was slight below 3 GHz and significant above 3 GHz. The thickness of the side support did not affect the reflection coefficient or the gain much. The performance of the fabricated discone antenna was in good agreement with the simulated results. This investigation of a dielectric support effects could be used to design a commercial discone antenna for broadband RF test chamber, focusing on electrical performance and mechanical stability.

Review on Performance Requirements, Design and Implementation of RF Transceiver for Mobile Communications

  • Lee, Il-Kyoo;Ryu, Seong-Ryeol;Oh, Seung-Hyeub;Hong, Heon-Jin
    • Information and Communications Magazine
    • /
    • v.24 no.3
    • /
    • pp.76-86
    • /
    • 2007
  • This paper describes the RF performance issues of UE RF Transceiver for W-CDMA system based on 3GPP specifications. the parameters of transmitter and receiver are derived from the viewpoint of RF performance. In order for UE to achieve high performance, the transceiver performance requirements such as ACIR, EVM, Peak Code Domain Error, spectrum emission mask, frequency error stability and TX power control dynamic range for transmitter and reference sensitivity level, blocking characteristics, noise figure, ACS, linearity, AGC dynamic range for receiver are considered. On the basis of the required parameters, the UE RF transceiver is designed and then implemented. The evaluation of RF performance is accomplished through practical test scenarios.

RF Transceiver Implementation to Evaluate the Requirements of 3G W-CDMA User Equipment (3G W-CDMA UE 요구사항 평가를 위한 RF 트랜시버 구현)

  • Il-Kyoo Lee;Seung-Hyeub Oh
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.2
    • /
    • pp.148-156
    • /
    • 2003
  • This paper describes the RF performance issues of UE for W-CDMA system based on 3 GPP specifications. The parameters of transmitter and receiver are derived from the viewpoint of RF performance. In order for UE to achieve high performance, the transceiver performance requirements such as ACLR, EVM, Peak Code Domain Error, spectrum emission mask, frequency error stability and TX power control dynamic range for transmitter and reference sensitivity level, blocking characteristics, noise figure, ACS, AGC dynamic range for receiver are considered. On the basis of the required parameters, the UE RF transceiver is implemented and then the evaluation of RF performance is accomplished through practical test scenarios.

Implementation of the RFID Multi Protocol Test System (RFID 멀티프로토콜 검사 시스템 구현)

  • Jeong, Jong-Hyeog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3399-3404
    • /
    • 2009
  • RFID system, which tries to identify a information of the tag using the wireless transmission, has been used to recognize long distance. However, each RFID system uses different way for individual needs. So, it is might not be compatible with the each system using a little different way. Also there is a trouble to freely use the protocols between the one tag and the other reader. So we tested a various RFID tags and readers to use the designed system with several protocols. Therefore, this paper shows that we designed and realized of the testing system for RF characteristics test as well as protocol analysis.

Clinical Characteristics of Psychiatric Patients with Military Issues Using MMPI-2-RF (군복무 적합성 평가를 위해 정신건강의학과에 내원한 환자군의 MMPI-2-RF 프로파일)

  • Sung, Gyhye;Park, Ji-Hyun;Kim, Keun-Hyang;Lee, Sang-Hyuk;Park, Eun-Hee;Choi, Ji Young
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.25 no.1
    • /
    • pp.33-45
    • /
    • 2017
  • Objectives : The purpose of this study was to examine psychological characteristics of patients who visited psychiatric clinic for medical certificate for military service using MMPI-2-RF. We compared target group with general psychiatric patients with same age range. Methods : A total of 165 male patients for medical certificate and 154 general psychiatric patients were collected from the Department of Psychiatry of three university hospitals. There were significant differences of age and educational level between two groups. We used independent t-test, ANCOVA, ${\chi}^2$ test to examine differences between two groups. Results : Medical certificate group scored higher on the validity scales, the Higher-Order(H-O) scales, the Restructured Clinical(RC) Scales, the Specific Problems(SP) Scales, and the Personality Psychopathology Five (PSY-5) Scales. Especially, EID, RC7, HLP, SFD, SAV, SHY, DSF, and INTR-r showed significant differences between two groups on all three statistical tests. Conclusions : The present study showed that psychiatric patients who received psychological evaluation for military service have significantly higher emotional distress, helplessness, lower self-confidence, and lower quality of interpersonal relationships. And the difference of validity scales between two groups could be related with psychological burden of compulsory military service in the study sample which causes elevation on scales of infrequent responses. MMPI-2-RF would be helpful instrument to assess these emotional and psychological characteristics.

Performance Analysis of UE RF Transmitting for WCDMA System (WCDMA 시스템에서 단말기 RF 송신 성능 분석)

  • LEE Il-kyoo;Jung Young-joon;HAN Sang-Chul;OH Seung-hyeub
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.293-296
    • /
    • 2003
  • This paper evaluates the RF transmitting parameters of User Equipment(UE) for W-CDMA system based on 3GPP specifications. The parameters of transmitter are derived from the aspect of RF. In order to keep UE in high performance, the transmitter requirements such as ACLR, EVM, Peak Code Domain Error, spectrum emission mask are considered. The UE transceiver is implemented on the basis of performance requirements and then tested for the analysis of RF transmitter characteristics through test scenarios.

  • PDF

RF Receiver design for Satellite Digital Audio Reception (Antenna)

  • Kim, Jang-Wook;Jeon, Joo-Seong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.7
    • /
    • pp.71-78
    • /
    • 2019
  • This paper describes a design for a RF receiver to receive satellite digital audio service. The RF receiver designed in this study is a planar structure that is easy to install on the rooftop of a car and is compact in size. In addition, it can be applied to certain commercial models because it has low noise and high gain characteristics. The impedance bandwidth of antenna is 17.8%(415MHz), and the axial ratio is below 3dB as good properties for the bandwidth of 40MHz which is a satellite digital audio service band. Also, it had a broad radiation beamwidth of $95.41^{\circ}$ in H-plane and $117.45^{\circ}$ in E-plane. From the results of the field test of satellite digital audio service reception for the RF receiver, it demonstrated good C/N rate(10.2dB).

Adhesion Enhancement of Thin Film Metals on Polyimide Substrates by Bias Sputtering

  • Kim S. Y.;Jo S. S.;Kang J. S.;Kim Y. H.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.3 s.36
    • /
    • pp.207-212
    • /
    • 2005
  • Al, Ti, Ta, and Cr thin films were deposited on a polyimide substrate using DC magnetron sputter to study the adhesion characteristics of metal films on polyimide substrates, while RF bias of 0 - 400 W was applied to the substrate during DC sputtering. The adhesion strength was evaluated using a 90-degree peel test. The peel tests showed that the adhesion strength was enhanced by applying the RF bias to the substrate in all specimens. Scanning electron microscopy and Auger depth profile of the fractured surfaces indicate that the polyimide underwent cohesive failure during peeling and heavy deformation was also observed in the metal films peeled from the polyimide substrate when the RF bias applied during the deposition. Cross-sectional transmission electron microscopy revealed that the metal/polyimide interface was not clear and complicated. This complicated interface, likely formed due to the RF bias applied to the substrate, was attributed to the adhesion enhancement observed during the bias sputtering.

  • PDF

A Study for Frequency Characteristics of Solenoid-Type RF Chip Inductors (크기에 따른 솔레노이드 형태 RF 칩 인덕터의 주파수 특성 연구)

  • Kim, Jae-Wook
    • Journal of IKEEE
    • /
    • v.11 no.4
    • /
    • pp.145-151
    • /
    • 2007
  • In this work, small-size, high-performance solenoid-type RF chip inductors utilizing a low-loss ${Al_2}{O_3}$ core material were investigated. The size of the chip inductors fabricated in this work were $0.86{\times}0.46{\times}0.45m^3$, $1.5{\times}1.0{\times}0.7m^3$, $2.1{\times}1.5{\times}1.0m^3$, and $2.4{\times}2.0{\times}1.4m^3$ and copper (Cu) wire with $27{\sim}40{\mu}m$ diameter was used as the coils. High frequency characteristics of the inductance, quality factor, and impedance of developed inductors were measured using an RF Impedance/Material Analyzer (HP4291B with HP16193A test fixture). It was observed that the developed inductors with the number of turns of 7 have the inductance of 13 to 100nH and exhibit the self-resonant frequency (SRF) of 6.4 to 1.1GHz. The SRF of inductors decreases with increasing the inductance and the inductors have the quality factor of 50 to 80 in the frequency range of 300MHz to 1.3GHz. In this study, small-size solenoid-type RF chip inductors with high inductance and high quality factor were fabricated successfully.

  • PDF

Fluorescent characteristics of baits and bait cages for swimming crab Portunus trituberculatus pots (꽃게 통발용 미끼 및 미끼통의 형광 특성)

  • Chang, Ho-Young;Koo, Jae-Geun;Lee, Keun-Woo;Cho, Bong-Kon;Jeong, Byung-Gon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.44 no.3
    • /
    • pp.174-183
    • /
    • 2008
  • In order to develop the substitutive materials for natural baits of swimming crab pots, the fluorescent characteristics of the baits were analyzed, and the preference of fluorescent dyes were investigated by the mean entrapped catch number to the pots through the water tank experiments and fishing experiments. On the investigation of fluorescent characteristics by the 5 kinds of baits, mackerel, krill, manila clam, pig's fat and chicken's head which were used in substitutive baits for test in the UV long wave(365nm) area, it showed clear blue fluorescence in the skin of mackerel, shell of krill, manila clam and bill of chicken's head, and green fluorescence in the mackerel s muscle and internals, and yellow fluorescence in the pig's fat and chicken's head. On the investigation of fluorescent characteristics by the bait cages in the UV short wave(254nm) and long wave(365nm) area, it showed each green, red and blue fluorescence in the cylinderical or hexahedral red plastic bait cages which were painted each green, red and blue fluorescence dyes, but it showed yellowish green flourescence in the cylinderical or hexahedral red plastic bait cage which was painted yellow fluorescent dye. On the preference investigation of the fluorescent dyes of swimming crabs by the 5 kinds of the bait cages which were put the mackerel in the non-fluorescent red plastic cage($RF_N$), red, yellow, green and blue fluorescent plastic cages(RF, YF, GF, BF) each, nonfluorescent red plastic cage($RF_N$) was entrapped mean 2.0(6.7%), but blue fluorescent plastic cage(BF) was mean 5.0(16.7%) and it was more 2.5 times comparing to $RF_N$, and red fluorescent cage(RF) was same level and green fluorescent cage(GF) was 50% of catch number comparing to $RF_N$, and yellow fluorescent cage(YF) was entrapped nothing(F 46.324, P < 0.05). On the investigation of the entrapped catch number to the pots which were put the mackerel in the blue fluorescent hexahedral plastic cage(HP) and blue fluorescent silicon mackerel model cage(SM), HP was mean 3.4(11.3%) and it was a little more comparing to SM which was entrapped mean 3.2(10.7%)(t 0.775, P > 0.05). Fishing experiments on the preference investigation of swimming crabs by the pots which were put in the non-fluorescent red plastic cage($RF_N$) and blue fluorescent plastic cage(BF) were conducted 3 times. Mean catching number and weight of $RF_N$ were 71.7 ind.(18.3%) and 16.9kg(64.3%), and those of BF were 93.0 ind.(23.1%) and 19.8kg(64.5%), respectively.