• Title/Summary/Keyword: RF Calibration

Search Result 59, Processing Time 0.032 seconds

Development of 3-Dimensional Sensor Nodes using Electro-magnetic Waves for Underwater Localization (수중 위치 추정을 위한 3차원 전자기파 센서 노드 개발)

  • Kwak, Kyung Min;Kim, Jinhyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.2
    • /
    • pp.107-112
    • /
    • 2013
  • In this paper, we discuss a 3-dimensional localization sensor node using EM waves (Electromagnetic waves) with RSSI (Received Signal Strength Indicator). Generally EM waves cannot be used in underwater environment, because the signal is highly attenuated by the water medium according to the distance. Although the signal quickly reduces in underwater, the reducing tendency is very clear and uniform. Hence EM waves have possibility as underwater distance sensors. The authors have verified the possibility by theory and several experiments, and developed calibration methods in case of linear and planer environment. For 3-dimensional localization in underwater, it must be known antenna's radiation pattern property in electric plane(called E-plane). In this paper, we proceed experiments to verify attenuation tendency with z axis movement, PLF (Polarization Loss Factor) and ILF (Inclination Loss Factor) with its theoretical approach.

Development of a V-Band Millimeter-Wave Source Module

  • Kwon, Jae-Yong;Lee, Dong-Joon;Bakti, Aditia Nur;Angin, Windi Kurnia Perangin
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.4
    • /
    • pp.225-228
    • /
    • 2016
  • KRISS-V, a V-band millimeter-wave source module for a primary RF power standard and calibration system developed by the Korea Research Institute of Standards and Science is here presented. The output power of KRISS-V is several times higher than that of commercial amplifier/multiplier chains and is highly stable (the standard deviations of output power are less than 0.01% in the worst case). The spectral purity of KRISS-V is high enough to consider it a single-tone signal generator. We also added programmable attenuation capability to KRISS-V for remote power control. Moreover, the in-house source module is cost-effective and adaptable to various measurement schemes. The structure of the model as well as detailed component information are introduced so that it can be reproduced.

CCD Pixel Correction Table Generation for MSC

  • Kim Young Sun;Kong Jong-Pil;Heo Haeng-Pal;Park Jong-Euk;Paik Hong-Yul
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.471-474
    • /
    • 2004
  • Not all CCD pixels generate uniform value for the uniform radiance due to the different process of manufacture and each pixel characteristics. And the image data compression is essential in the real time image transmission because of the high line rate and the limited RF bandwidth. This pixel's nonuniformity and the loss compression make CCD pixel correction necessary in on-orbit condition. In the MSC system, the NUC unit, which is a part of MSC PMU, is charge of the correction for CCD each pixel. The correction is performed with the gain and the offset table for the each pixel and the each TDI mode. These correction tables are generated and programmed in the PMU Flash memory through the various image data tests at the ground test. Besides, they can be uploaded from ground station after onorbit calibration. This paper describes the principle of the table generation and the test way of the non-uniformity after NUC

  • PDF

Development of low power GPS receiver

  • Kim, Il-Kyu;Lee, Jae-Ho;Seo, Hung-Serk;Park, Chan-Sik;Lee, Sang-Jeong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.114.6-114
    • /
    • 2001
  • According to expansion of wireless communication system and mobile device, interest has been growing in personal navigation system integrated with wireless system. In portable consumer electronics, such as cellular phones, GPS and PDA, one of major design factors is the power consumption. Solutions of reducing the power dissipation are low voltage, low system clock power management and so on. This paper develops a GPS receiver based on the advanced power management algorithm that achieves very low average power consumption. Both RF and DSP chips are powered down and reactivated only when the position fixing is required. In order to run, the developed includes the RTC calibration function and the fast reacquisition function using XMC (eXtended Multiple Correlator) ...

  • PDF

Implementation and Verification of Linear Phase filter with Variable Cutoff Frequency for PCM/FM transmission (PCM/FM 전송을 위한 가변 컷오프 주파수 특성의 선형위상 필터 구현 및 검증)

  • Lee Sang-Rae;Ra Sung-Woong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.7C
    • /
    • pp.713-724
    • /
    • 2006
  • The purpose of this study is to design, implement and verify the pre-modulation filter with the variable -3dB cutoff frequency and linear phase response for bandlimiting the allocation of radio frequency bandwidth for PCM/FM transmission. For the design of this required filter, the digital FIR filter, DAC system and tuneable 2nd order LPF have been constructed and simulated according to the attenuation characteristic requirement of the amplitude frequency response by each stage. From these results, we have implemented the filter and verified the analog conversion hardware part which is composed of DAC system and tuneable 2nd order LPF for the interpolation of the discrete sequences. Especially this paper proposes and carries out the verification processes using the tone generator and the calibration procedures for more precise frequency response of the filter.

The Fundamental Studies of the New Glow Discharge/Inductively Coupled Plasma Interface: Part Ⅰ. Preliminary Studies (새로운 글로우 방전/유도결합 플라스마 장치(GD/ICP Interface)에 대한 기초 연구: Part Ⅰ. 기초 연구)

  • Lee, Gae Ho;Kil, Hyo Shik;Kim, Hyung Seung;Gary M. Hieftje
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.2
    • /
    • pp.182-192
    • /
    • 1999
  • The new GD/ICP-AES quick change over system has been developed and characterized. Within less than 15 minutes, ICP-AES could be switched to GD-AES and vise a versa. As a result, both solid and liquid samples could be analyzed in a very short period of time by the ICP/GD-AES quick change over system developed in our laboratory. The influences of the experimental variables, such as flow rate of coolant gas, flow rate of auxiliary gas, flow rate of sample carrier gas, sampling depth, orifice size of sampling cone, and rf (radio frequency) power on emission intensity have been presented. The detection limits of Cd(I) 228.8 nm, Mn (II) 257.61 nm, and Fe(II) 259.95 nm were found to be 3.86, 1.49, and 5.79 ppb, respectively. And linealities of the calibration curves were measured to be unity.

  • PDF

Determination of Ginseng Saponins by Reversed-Phase High Performance Liquid Chromatography (역상 고속 액체크로마토그래피를 이용한 인삼 사포닌의 분석)

  • Jeong, Seung-Il;Kim, Choen-Suk;Lee, No-Woon;Choi, Kang-Ju;Lee, Yong-Gu;Kim, Il-Kwang
    • Analytical Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.436-439
    • /
    • 1998
  • Ginseng saponins were analysed using reversed-phase high performance liquid chromatography with several columns. The optimum conditions were as following : reverse phase column; Novapak $C_{18}$ ODS column ($3.9mm{\times}150mm$, $5{\mu}m$), acetonitrile/water binary mobile phase gradient controller system, solvent flow rate; 1.5 mL/min, and UV (203 nm) detector. The complete separation of ginsenoside $Rb_1$, $Rb_2$, Rc, Rd, Re, Rf and $Rg_1$ was achieved within 50 min. The regression coefficients of the calibration curves for seven ginsenosides were 0.98~0.99.

  • PDF

New In-Orbit Pixel Correction Method

  • Kim Youngsun;Kong Jong-Pil;Heo Haeng-Pal;Park Jong-Euk;Chang Young-Jun
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.604-607
    • /
    • 2005
  • All CCD pixels do not react uniformly even if the light of same radiance enters into the camera. This comes from the different camera optical characteristics, the read-out characteristics, the pixel own characteristics and so on. Usually, the image data of satellite camera can be corrected by the various image-processing methods in the ground. However, sometimes, the in-orbit correction is needed to get the higher quality image. Especially high frequency pixel correction in the middle of in-orbit mission is needed because the in-orbit data compression with the high frequency loss is essential to transmit many data in real time due to the limited RF bandwidth. In this case, this high frequency correction can prevent have to have any unnecessary high frequency loss. This in-orbit correction can be done by the specific correction table, which consists of the gain and the offset correction value for each pixel. So, it is very important to get more accurate correction table for good correction results. This paper shows the new algorithm to get accurate pixel correction table. This algorithm shall be verified theoretically and also verified with the various simulation and the test results.

  • PDF

Continuous Blood Pressure Monitoring using Pulse Wave Transit Time

  • Jeong, Gu-Young;Yu, Kee-Ho;Kim, Nam-Gyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.834-837
    • /
    • 2005
  • In this paper, we describe the method of non-invasive blood pressure measurement using pulse wave transit time(PWTT). PWTT is a new parameter involved with a vascular that can indicate the change of BP. PWTT is measured by continuous monitoring of ECG and pulse wave. No additional sensors or modules are required. In many cases, the change of PWTT correlates with the change of BP. We measure pulse wave using the photo plethysmograph(PPG) sensor in an earlobe and we measure ECG using the ECG monitoring device our made in the chest. The measurement device for detecting pulse wave consists of infrared LED for transmitted light illumination, pin photodiode as light detector, amplifier and filter. We composed 0.5Hz high pass, 60Hz notch and 10Hz low pass filter. ECG measurement device consists of multiplexer, amplifier, filter, micro-controller and RF module. After amplification and filtering, ECG signal and pulse wave is fed through micro-controller. We performed the initial work towards the development of ambulatory BP monitoring system using PWTT. An earlobe is suitable place to measure PPG signal without the restraint in daily work. From the results, we can know that the dependence of PWTT on BP is almost linear and it is possible to monitoring an individual BP continuously after the individual calibration.

  • PDF

Radar Backscattering Measurements of Paddy Rice Field using L, C, and X-band Polarimetric Scatterometer

  • Kim, Yi-Hyun;Hong, Suk-Young;Park, Ji-Sung;Lee, Eun-Sun;Lee, Hoon-Yol
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.633-636
    • /
    • 2007
  • The objective of this study is to measure backscattering coefficients of paddy rice using L, C, X-bands scatterometer system during a rice growth period. The measurement was conducted at an experimental field located in National Institute of Agricultural Science and Technology (NIAST), Suwon, Korea. The rice cultivar was a kind of Japonica type, called Chuchung. The scatterometer system consists of dual-polarimetric square horn antennas, HP8720D vector network analyzer (20MHz ${\sim}$ 20GHz), RF cables, and a personal computer that controls frequency, polarization and data storage. The scatterometer system is calibrated using a calibration kit (3.5mm, 85052D). The backscattering coefficients were calculated by applying radar equation for the measured at incidence angles between $20^{\circ}$ and $60^{\circ}$ for four polarization (HR, VV, HV, VH), respectively, and compared with rice growth data such as plant height, stem number, biomass, dry weight and LAI that were collected at time of each scatterometer measurement simultaneously.

  • PDF